Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
J Med Syst ; 48(1): 28, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38441786

RESUMO

BACKGROUND: The Virtual Reality Headset (VRH) is a device aiming at improving patient's comfort by reducing pain and anxiety during medical interventions. Its interest during cardiac implantable electronic devices (CIED) implant procedures has not been studied. METHODS: We randomized consecutive patients admitted for pacemaker or Implantable Cardioverter Defibrillator (ICD) at our center to either standard analgesia care (STD-Group), or to VRH (VRH-Group). Patients in the STD-Group received intra-venous paracetamol (1 g) 60 min before the procedure, and local anesthesia was performed with lidocaine. For patients of the VRH-Group, VRH was used on top of standard care. We monitored patients' pain and anxiety using numeric rating scales (from 0 to 10) at the time of sub-cutaneous pocket creation, and during deep axillary vein puncture. Patient comfort during the procedure was assessed using a detailed questionnaire. Morphine consumption was also assessed. RESULTS: We randomized 61 patients to STD-Group (n = 31) or VRH-Group (n = 30). Pain and anxiety were lower in the VRH-Group during deep venous puncture (3.0 ± 2.0 vs. 4.8 ± 2.2, p = 0.002 and 2.4 ± 2.2 vs. 4.1 ± 2.4, p = 0.006) but not during pocket creation (p = 0.58 and p = 0.5). Morphine consumption was lower in the VRH-Group (1.6 ± 0.7 vs. 2.1 ± 1.1 mg; p = 0.041). Patients' overall comfort during procedure was similar in both groups. CONCLUSION: VRH use improved pain and anxiety control during deep venous puncture compared to standard analgesia care, and allowed morphine consumption reduction. However, pain and anxiety were similar at the time of sub-cutaneous pocket creation.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Ansiedade/prevenção & controle , Dor , Derivados da Morfina
2.
Front Cardiovasc Med ; 10: 1145894, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37663412

RESUMO

Background: Persistent Atrial Fibrillation (PersAF) electrogram-based ablation is complex, and appropriate identification of atrial substrate is critical. Little is known regarding the value of the Average Complex Interval (ACI) feature for PersAF ablation. Objective: Using the evolution of AF complexity by sequentially computing AF dominant frequency (DF) along the ablation procedure, we sought to evaluate the value of ACI for discriminating active drivers (AD) from bystander zones (BZ), for predicting AF termination during ablation, and for predicting AF recurrence during follow-up. Methods: We included PersAF patients undergoing radiofrequency catheter ablation by pulmonary vein isolation and ablation of atrial substrate identified by Spatiotemporal Dispersion or Complex Fractionated Atrial Electrograms (>70% of recording). Operators were blinded to ACI measurement which was sought for each documented atrial substrate area. AF DF was measured by Independent Component Analysis on 1-minute 12-lead ECGs at baseline and after ablation of each atrial zone. AD were differentiated from BZ either by a significant decrease in DF (>10%), or by AF termination. Arrhythmia recurrence was monitored during follow-up. Results: We analyzed 159 atrial areas (129 treated by radiofrequency during AF) in 29 patients. ACI was shorter in AD than BZ (76.4 ± 13.6 vs. 86.6 ± 20.3 ms; p = 0.0055), and mean ACI of all substrate zones was shorter in patients for whom radiofrequency failed to terminate AF [71.3 (67.5-77.8) vs. 82.4 (74.4-98.5) ms; p = 0.0126]. ACI predicted AD [AUC 0.728 (0.629-0.826)]. An ACI < 70 ms was specific for predicting AD (Sp 0.831, Se 0.526), whereas areas with an ACI > 100 ms had almost no chances of being active in AF maintenance. AF recurrence was associated with more ACI zones with identical shortest value [3.5 (3-4) vs. 1 (0-1) zones; p = 0.021]. In multivariate analysis, ACI < 70 ms predicted AD [OR = 4.02 (1.49-10.84), p = 0.006] and mean ACI > 75 ms predicted AF termination [OR = 9.94 (1.14-86.7), p = 0.038]. Conclusion: ACI helps in identifying AF drivers, and is correlated with AF termination and AF recurrence during follow-up. It can help in establishing an ablation plan, by prioritizing ablation from the shortest to the longest ACI zone.

4.
J Clin Med ; 12(14)2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37510813

RESUMO

BACKGROUND: CLOSE-guided pulmonary vein isolation (PVI) is based on contiguous and optimized (Ablation Index-guided) radiofrequency lesions. The efficacy of CLOSE-guided PVI in persistent atrial fibrillation (AF) treatment has been poorly evaluated. METHODS: In two centers, 50 patients eligible for persistent AF ablation underwent CLOSE-guided PVI (Ablation Index ≥ 450 at the anterior wall, ≥300 at posterior wall, intertag distance ≤ 6 mm). If PVI failed to restore sinus rhythm (SR), electrical cardioversion (ECV) was performed. Atrial substrate modification (ASM) was performed only if PVI and ECV failed to restore SR. Recurrence was defined as any recorded episode of AF, atrial tachycardia (AT) or atrial flutter (AFL) > 30 s on Holter electrocardiographs at 3, 6 and 12 months. RESULTS: From the 50 patients (64 ± 10 years, 14% long-standing persistent AF), SR was restored by ECV in 34 patients (68%) 56 ± 38 days prior to ablation. On the day of ablation, 42 patients (84%) were on class I-III anti-arrhythmic drug therapy (ADT) and the rhythm was AF in 23/50 patients. PVI was achieved in all patients; after PVI, ECV was required in 21 patients and ASM in 1 patient. The mean procedure time, radiofrequency time and fluoroscopy time were 141 ± 33 min, 23 ± 7 min and 7 ± 6 min, respectively. At 12 months, single-procedure freedom from AF/AT/AFL was 80%, with 19 patients (38%) receiving class I-III ADT. CONCLUSIONS: In a population of patients with persistent AF monitored with intermittent cardiac rhythm recordings, CLOSE-guided PVI resulted in high single-procedure arrhythmia-free survival at 1 year. Future large-scale studies involving continuous cardiac monitoring are necessary.

5.
J Cardiovasc Electrophysiol ; 34(7): 1577-1581, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37293820

RESUMO

INTRODUCTION: We describe an unusual case of atrial tachycardia (AT) emanating from the left atrial appendage body (LAA), successfully treated by chemical ablation. METHODS: A 66-year-old patient with cardiac amyloidosis and history of persistent atrial fibrillation ablation presented poorly tolerated AT with 1:1 atrioventricular nodal conduction at 135/min, despite amiodarone therapy. Three-dimensional mapping suggested a reentrant AT from the anterior aspect of the left LAA. RESULTS: The tachycardia could not be terminated with radiofrequency ablation. The LAA vein was then selectively catheterized and infused with Ethanol, resulting in immediate termination of tachycardia, without LAA isolation. No recurrence occurred at 12 months. CONCLUSION: Atrial tachycardias emanating from the LAA that are resistant to radiofrequency ablation may respond to chemical ablation of the LAA vein.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Humanos , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Taquicardia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
6.
Ann Noninvasive Electrocardiol ; 28(4): e13057, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37002650

RESUMO

Common atrium (CA), also called three-chambered heart, is one of the rare congenital anomalies, defined by a complete absence of the atrial septum, eventually associated with malformation of the atrioventricular (AV) valves. We report the case of a 57-year-old woman with CA complicated with Eisenmenger syndrome and inferior vena cava interruption, who suffered from symptomatic persistent atrial fibrillation (AF). She underwent an initial successful pulmonary vein isolation procedure. A repeat procedure for perivalvular atrial flutter was complicated with inadvertent complete AV block, due to unusual AV node location in this challenging anatomy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas , Defeitos dos Septos Cardíacos , Feminino , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Veia Cava Inferior/anormalidades , Resultado do Tratamento , Eletrocardiografia , Cardiopatias Congênitas/cirurgia , Nó Atrioventricular , Ablação por Cateter/métodos
7.
J Clin Med ; 12(3)2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36769716

RESUMO

BACKGROUND: Female gender, degree of QT prolongation, and genetic susceptibility are known risk factors for developing torsades de pointes (TdP) during high-grade atrioventricular block (HG-AVB). Our objective was to analyze the prevalence and clinical characteristics of patients presenting with TdP and AVB (TdP [+]) in comparison with non-TdP patients with AVB (TdP [-]). METHODS: All the ECGs from patients prospectively admitted for AVB (2 to 1, HG, and complete) at the University Hospital of Nice were analyzed. Automated corrected QT (QTc), manual measurements of QT and JT intervals, and Tpeak-to-end were performed at the time of the most severe bradycardia. RESULTS: From September 2020 to November 2021, 100 patients were admitted for HG-AVB. Among them, 17 patients with TdP were identified (8 men; 81 ± 10 years). No differences could be identified concerning automated QTc, manual QTc (Bazett correction), baseline QRS width, or mean left ventricular ejection fraction between the two groups. Potassium serum level on admission and mean number of QT-prolonging drugs per patient were not significantly different between the two groups, respectively: 4.34 ± 0.5 mmol/L in TdP [+] versus 4.52 ± 0.6 mmol/L (p = 0.33); and 0.6 ± 0.7 in TdP [+] versus 0.3 ± 0.5 (p = 0.15). In contrast, manual QTcFR (Fridericia correction), JT (Fridericia correction), Tpeak-to-end, and Tpe/QT ratio were significantly increased in the TdP [+] group, respectively: 486 ± 70 ms versus 456 ± 53 ms (p = 0.04); 433 ± 98 ms versus 381 ± 80 ms (p = 0.02); 153 ± 57 ms versus 110 ± 40 ms (p < 0.001); and 0.27 ± 0.08 versus 0.22 ± 0.06 (p < 0.001). CONCLUSIONS: The incidence of TdP complicating acquired AVB was 17%. Longer QTcFR, JT, and Tpeak-to-end were significantly increased in the case of TdP but also in the presence of permanent AVB during the hospitalization.

8.
Circ Arrhythm Electrophysiol ; 16(3): e011354, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802906

RESUMO

BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do Tratamento
10.
Heart Rhythm ; 20(2): 252-260, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36309156

RESUMO

BACKGROUND: In repaired tetralogy of Fallot (TOF), little is known about characteristics of patients with rapid ventricular tachycardia (VT). Also, whether patients with a first episode of nonrapid VT may subsequently develop rapid VT or ventricular fibrillation (VF) has not been addressed. OBJECTIVES: The objectives of this study were to compare patients with rapid VT/VF with those with nonrapid VT and to assess the evolution of VT cycle lengths (VTCLs) overtime. METHODS: Data were analyzed from a nationwide registry including all patients with TOF and implantable cardioverter-defibrillator (ICD) since 2000. Patients with ≥1 VT episode with VTCL ≤250 ms (240 beats/min) formed the rapid VT/VF group. RESULTS: Of 144 patients (mean age 42.0 ± 12.7 years; 104 [72%] men), 61 (42%) had at least 1 VT/VF episode, including 28 patients with rapid VT/VF (46%), during a median follow-up of 6.3 years (interquartile range 2.2-10.3 years). Compared with patients in the nonrapid VT group, those in the rapid VT/VF group were significantly younger at ICD implantation (35.2 ± 12.6 years vs 41.5 ± 11.2 years; P = .04), had more frequently a history of cardiac arrest (8 [29%] vs 2 [6%]; P = .02), less frequently a history of atrial arrhythmia (11 [42%] vs 22 [69%]; P = .004), and higher right ventricular ejection fraction (43.3% ± 10.3% vs 36.6% ± 11.2%; P = .04). The median VTCL of VT/VF episodes was 325 ms (interquartile range 235-429 ms). None of the patients with a first documented nonrapid VT episode had rapid VT/VF during follow-up. CONCLUSION: Patients with TOF and rapid VT/VF had distinct clinical characteristics. The relatively low variation of VTCL over time suggests a room for catheter ablation without a backup ICD in selected patients with well-tolerated VT.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Tetralogia de Fallot , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Feminino , Volume Sistólico , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Seguimentos , Função Ventricular Direita , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular
11.
Eur Heart J Cardiovasc Imaging ; 23(11): 1562-1572, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36265185

RESUMO

AIMS: Outcomes in pulmonary hypertension (PH) are related to right ventricular (RV) function and remodelling. We hypothesized that changes in RV function and especially area strain (AS) could provide incremental prognostic information compared to the use of baseline data only. We therefore aimed to assess RV function changes between baseline and 6-month follow-up and evaluate their prognostic value for PH patients using 3D echocardiography. METHODS AND RESULTS: Ninety-five PH patients underwent a prospective longitudinal study including ESC/ERS guidelines prognostic assessment and 3D RV echocardiographic imaging at baseline and 6-month follow-up. Semi-automatic software tracked the RV along the cycle, and its output was post-processed to extract 3D deformation patterns. Over a median follow-up of 24.8 (22.1-25.7) months, 21 patients died from PH or were transplanted. Improvements in RV global AS were associated with stable or improving clinical condition as well as survival free from transplant (P < 0.001). The 3D deformation patterns confirmed that the most significant regional changes occurred within the septum. RV global AS change over 6-month by +3.5% identifies patients with a 3.7-fold increased risk of death or transplant. On multivariate COX analysis, changes in WHO class, BNP, and RV global AS were independent predictors of outcomes. Besides, the combination of these three parameters was of special interest to identify high-risk patients [HR 11.5 (1.55-86.06)]. CONCLUSION: Changes in RV function and especially changes in 3D RV AS are of prognostic importance. Our study underlines that assessing such changes from baseline to follow-up is of additional prognostic value for PH patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/ct2/show/NCT02799979.


Assuntos
Hipertensão Pulmonar , Disfunção Ventricular Direita , Humanos , Ecocardiografia , Seguimentos , Hipertensão Pulmonar/diagnóstico por imagem , Estudos Longitudinais , Prognóstico , Estudos Prospectivos
12.
JACC Clin Electrophysiol ; 8(10): 1304-1314, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36266008

RESUMO

BACKGROUND: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far. OBJECTIVES: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs). METHODS: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years) were enrolled from 40 centers, including 49 women (29.7%). Among the 9,692 patients with TOF recorded in the national database, the proportion of women with ICDs was estimated to be 1.1% (95% CI: 0.8%-1.5%) vs 2.2% (95% CI: 1.8%-2.6%) in men (P < 0.001). The clinical profiles of patients at implantation, including the number of risk factors for ventricular arrhythmias, were similar between women and men. During a median follow-up period of 6.8 years (IQR: 2.5-11.4 years), 78 patients (47.3%) received at least 1 appropriate ICD therapy, without significant difference in annual incidences between women (12.1%) and men (9.9%) (HR: 1.22; 95% CI: 0.76-1.97; P = 0.40). The risk for overall ICD-related complications was similar in women and men (HR: 1.33; 95% CI: 0.81-2.19; P = 0.30), with 24 women (49.0%) experiencing at least 1 complication. CONCLUSIONS: Our findings suggest that women with TOF at high risk for sudden cardiac death have similar benefit/risk balance from ICD therapy compared with men. Whether ICD therapy is equally offered to at-risk women vs men warrants further evaluation in TOF as well as in other congenital heart disease populations. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Tetralogia de Fallot , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Tetralogia de Fallot/complicações , Estudos de Coortes , Caracteres Sexuais , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Cardiopatias Congênitas/complicações
13.
J Clin Med ; 11(15)2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35956135

RESUMO

Background. Fibrillatory Wave Amplitude (FWA) has been described as a non-invasive marker of atrial fibrillation (AF) complexity, and it predicts catheter ablation outcome. However, the actual determinants of FWA remain incompletely understood. Objective. To assess the respective implications of anatomical atrial substrate and AF spectral characteristics for FWA. Methods. Persistent AF patients undergoing radiofrequency catheter ablation were included. FWA was measured on 1-min ECG by TQ concatenation in Lead I, V1, V2, and V5 at baseline and immediately before AF termination. FWA evolution during ablation was compared to that of AF dominant frequency (DF) measured by Independent Component Analysis on 12-lead ECG. FWA was compared to the extent of endocardial low-voltage areas (LVA I < 10%; II 10-20%; III 20-30%; IV > 30%), to the surface of healthy left atrial tissue, and to P-wave amplitude in sinus rhythm. The predictive value of FWA for AF recurrence during follow-up was assessed. Results. We included 29 patients. FWA remained stable along ablation procedure with comparable values at baseline and before AF termination (Lead I p = 0.54; V1 p = 0.858; V2 p = 0.215; V5 p = 0.14), whereas DF significantly decreased (5.67 ± 0.68 vs. 4.95 ± 0.58 Hz, p < 0.001). FWA was higher in LVA-I than in LVA-II, -III, and -IV in Lead I and V5 (p = 0.02 and p = 0.01). FWA in V5 was strongly correlated with the surface of healthy left atrial tissue (R = 0.786; p < 0.001). FWA showed moderate to strong correlation to P-wave amplitude in all leads. Finally, FWA did not predict AF recurrence after a follow-up of 23.3 ± 9.8 months. Conclusions. These findings suggest that FWA is unrelated to AF complexity but is mainly determined by the amount of viable atrial myocytes. Therefore, FWA should only be referred as a marker of atrial tissue pathology.

14.
J Clin Med ; 11(2)2022 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-35054143

RESUMO

BACKGROUND: In patients with complete atrioventricular block (AVB), the prevalence and clinical characteristics of patients with pause-dependent AVB (PD-AVB) is not known. Our objective was to assess the prevalence of PD-AVB in a population of patients with complete (or high-grade) AVB. METHODS: Twelve-lead electrocardiogram (ECG) and/or telemonitoring from patients admitted (from September 2020 to November 2021) for complete (or high-degree) AVB were prospectively collected at the University Hospital of Nice. The ECG tracings were analyzed by an electrophysiologist to determine the underlying mechanism of PD-AVB. RESULTS: 100 patients were admitted for complete (or high-grade) AVB (men 55%; 82 ± 12 years). Arterial hypertension was present in 68% of the patients. Baseline QRS width was 117 ± 32 ms, and mean left ventricular ejection fraction was 56 ± 7%. Fourteen patients (14%) with PD-AVB were identified, and presented similar clinical characteristics in comparison with patients without PD-AVB, except for syncope (which was present in 86% versus 51% in the non-PD-AVB patients, p = 0.01). PD-AVB sequence was induced by: Premature atrial contraction (8/14), premature ventricular contraction (5/14), His extrasystole (1/14), conduction block in a branch (1/14), and atrial tachycardia termination (1/14). All patients with PD-AVB received a dual-chamber pacemaker during hospitalization. CONCLUSION: The prevalence of PD-AVB was 14%, and may be underestimated. PD-AVB episodes were more likely associated with syncope in comparison with patients without PD-AVB.

15.
Acta Cardiol ; 77(6): 524-531, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34412553

RESUMO

BACKGROUND: Radiofrequency (RF) ablation of slow pathway (SP) is usually performed in sinus rhythm while monitoring the occurrence of a slow junctional rhythm (JR). JR although sensitive, is not specific for elimination of SP conduction. Our objective was to prospectively evaluate feasibility and safety of SP elimination using fast atrial rate pacing (FAP) during RF delivery. METHODS: Consecutive patients admitted for atrioventricular nodal re-rentrant tachycardia (AVNRT) ablation were included. The rate of proximal coronary sinus (CS) pacing was set to a value constantly yielding antegrade SP conduction, while carefully monitoring the AH interval. RF delivery (at the lower part of Koch's triangle) was considered successful if the AH shortened ≥ 14 ms or if transition from Wenckebach (WK) periods to a 1:1 conduction occurred. RESULTS: 24 patients were included (54 ± 20 y). Typical AVNRT was induced in all (cycle length 349 ± 83 ms). RF delivery during CS pacing (335 ± 73 ms) led to AH shortening by 51 ± 25 ms in 13 patients. In 10 patients, a transition from 3:2 or 4:3 WK periods to 1:1 conduction occurred during the successful pulse. In one patient, atrial fibrillation was systematically induced during FAP, requiring conventional ablation. Non-inducibility, and SP conduction disappearance was obtained in all patients. No patient developed AV block. After a follow-up of 12 ± 3 months, no recurrences were observed. CONCLUSION: SP ablation using FAP during RF delivery allows direct visualisation of its disappearance. In our cohort of patients, this technique was feasible without safety compromise.


Assuntos
Bloqueio Atrioventricular , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fascículo Atrioventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia
16.
J Interv Card Electrophysiol ; 63(1): 29-37, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33506319

RESUMO

PURPOSE: Diagnosis of atrial tachycardia (AT) with 3D mapping system remains challenging due to fibrosis or previous ablation. This study aims to evaluate a new electroanatomical mapping annotation setting using a window of interest adjusted at the end of the P wave (WOIp wave) to identify the AT mechanism more accurately. METHODS: Twenty patients with successful ablation of left AT using navigation system CARTO3 were evaluated. Two maps for each patient were generated offline using either conventional settings of WOI (WOIconv.) or WOIp wave. Three investigators from two centres analysed the maps blindly. RESULTS: Mechanisms of AT were macroreentrant in 14/20 patients (70%) and focal in 6/20 (30%). WOIp wave resulted in a significant increase in the percentage of correct identification of the mechanism based on mapping alone (93.3 ± 13.7% vs 58.3 ± 33.9%; p = 0.0003) compared with WOIconv.. Diagnoses based on mapping were arrived at faster (27.8 ± 16.4 s vs 38.97 ± 13.64 s, respectively; p = 0.0231) and with a greater confidence in the diagnosis (confidence index 2.57 ± 0.45 vs 2.12 ± 0.45, respectively; p = 0.0024). With perimitral re-entry specifically "early meets late" was closer to the anatomical region of the mitral isthmus (15.9 ± 20.9 mm vs 48.77 ± 23.23 mm, respectively; p = 0.0028). CONCLUSIONS: This study found that electroanatomical mapping acquisition with a window of interest set at the end of the P wave improves the ability to diagnose the arrhythmia mechanism based on the initial map. It is particularly beneficial in identifying area of interest for ablation in perimitral AT.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Átrios do Coração/cirurgia , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia
17.
Ann Cardiol Angeiol (Paris) ; 71(3): 176-180, 2022 Jun.
Artigo em Francês | MEDLINE | ID: mdl-34955165

RESUMO

A 20-year-old patient is admitted to the emergency room for chest pain occurring in the context of recurrent left complete pneumothorax. Ultrasensitive troponinemia is elevated to 20 times normal. Myocardial distress is attributed to pneumothorax following the negativity of cardiological examinations (EKG, TTE, cardiac MRI). The pneumothorax is drained with a favorable evolution. This is the first reported case of pneumothorax associated with a significant elevation of troponin without ECG change, TakoTsubo syndrome, or myocardial inflammation. Several mechanisms are considered: rotation of the myocardium around its axis, increase in pulmonary vascular resistance with overload of right ventricular pressure, disturbance of coronary blood flow on significant mediastinal compression with decrease in systolo-diastolic myocardial perfusion.


Assuntos
Pneumotórax , Cardiomiopatia de Takotsubo , Adulto , Dor no Peito/etiologia , Serviço Hospitalar de Emergência , Humanos , Pneumotórax/diagnóstico , Troponina , Adulto Jovem
18.
BMJ Open ; 11(9): e050910, 2021 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-34588255

RESUMO

OBJECTIVES: Severity of a first pulmonary embolism (PE) is sometimes proposed as a criterion for prolonging anticoagulant treatment. However, little evidence supports this idea. We attempted to determine the connection between severity of first PE and the risk of recurrence. PARTICIPANTS: Patients admitted with PE between 2012 and 2018 and for whom anticoagulant treatment had been discontinued were followed. PEs were classified according to the severity into the following two groups: those with associated cardiac involvement (increased cardiac biomarker(s) and/or echocardiographic right ventricular dysfunction) and those with no cardiac involvement which were classified as non-severe. Recurrence-free survivals were estimated using the Kaplan-Meier method and compared using the log-rank test. RESULTS: 417 patients with PEs (186 with cardiac involvement) were followed for at least 1 year after discontinuation of treatment with a mean follow-up of: 3.5±1.9 years. 72 patients (17.3%) experienced venous thromboembolism recurrence: 24 (5.8%), 44 (12 %) and 72 (28.3 %) respectively, at 1, 2 and 5 years. In 63 patients (88%), recurrence was a PE. Mean time to onset of recurrence was 24.9±19.9 months. At 5 years, the recurrence rate is higher when the first PE was associated with cardiac involvement p=0.043. In contrast, in patients with provoked PE, the recurrence rate is higher when the first PE event was associated with cardiac involvement: p=0.032. Multivariate analysis demonstrates that PE severity is an independent factor of recurrence (HR 1.634 (1.015-2.632), p=0.043). CONCLUSION: We report for the first time a possible link between a higher recurrence rate and the severity of the first PE. This result which must be confirmed in a dedicated prospective trial could become an important criterion for the duration of anticoagulant therapy after a PE. TRIAL REGISTRATION NUMBER: NCT04980924.


Assuntos
Embolia Pulmonar , Tromboembolia Venosa , Anticoagulantes/uso terapêutico , Humanos , Estudos Prospectivos , Embolia Pulmonar/tratamento farmacológico , Embolia Pulmonar/epidemiologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Tromboembolia Venosa/tratamento farmacológico , Tromboembolia Venosa/epidemiologia
19.
J Clin Med ; 10(11)2021 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-34204104

RESUMO

BACKGROUND: Whether unidirectional conduction block (UB) can be observed after creation of a radiofrequency (RF) line is still debated. Previous studies reported a prevalence of 9 to 33% of UB, but the assessment was performed using a point-by-point recording across the line. Ultra-high-density (UHD) system may bring some new insights on the exact prevalence of UB. PURPOSE: A prospective study was conducted to assess the prevalence of UB and bidirectional block (BB) using UHD system after RF line creation. METHODS: Patients referred for atrial RF ablation procedure were included in this multicenter prospective study. UHD maps were performed by pacing both sides of the created line. RESULTS: A total of 80 maps were created in 40 patients (67 ± 12 years, 70% male) by pacing (mean cycle length 600 ± 57 ms) from both sides of the cavotricuspid isthmus line. After a 47 ± 17 min waiting time after the last RF application, UHD maps (mean number of 4842 ± 5010 electrograms, acquired during 6 ± 5 min) showed that BB was unambiguously confirmed on all of them. UB was not observed in any map. After a mean follow-up of 12 ± 4 months, 6 (14%) patients experienced an arrhythmia recurrence. CONCLUSION: After creation of an RF line, no case of UB was observed using UHD mapping, suggesting that the presence of a conduction block along a RF line is always associated with a block in the opposite direction.

20.
J Interv Card Electrophysiol ; 60(2): 213-219, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32219588

RESUMO

BACKGROUND: The fluoroscopic individualized LAO (i-LAO) projection has demonstrated high accuracy for identifying right ventricular (RV) lead positioning, likely by approximating a view along the septal or RV long axes. However, RV and septal anatomical axes have not been studied, and their relation with i-LAO is unknown. We sought to determine RV, septal, and left ventricular (LV) long-axis orientations by CT scan and to compare them to the i-LAO angle, to confirm the anatomical relevance of i-LAO. METHODS: We prospectively included patients (pts) for whom i-LAO angle was determined during pacemaker or defibrillator implant. Then, RV, septal, and LV long-axis orientations were determined by CT scan by a physician blinded to i-LAO data. The horizontal components of the cardiac axes were compared with those of the i-LAO angle. RESULTS: We included 26 pts. Median values were 57.5° for i-LAO angle (range 47.5-70), 64.5° for RV axis (range 48-90), 51.5° for septal axis (range 39-74), and 37° for LV axis (range 25-67). i-LAO angle best correlated with septal axis (r = 0.91 and ρc = 0.71). Up to an angle of 70° (maximal measurable i-LAO value; 23/26 pts), the i-LAO angle was comprised between the septal and the RV axes (21/23 pts, 91.3%), or within 2° of this interval (2/23 pts, 8.7%). CONCLUSIONS: RV and septal anatomical axes present major interindividual variations, prompting the use of individualized fluoroscopy criteria for lead implantation. i-LAO angle demonstrated to be almost constantly between the septal and RV long axes, thus confirming its anatomical relevance for RV lead implantation.


Assuntos
Ventrículos do Coração , Marca-Passo Artificial , Arritmias Cardíacas , Fluoroscopia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...