Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38550657

RESUMO

Introduction: The clinical implementation of deep inspiratory breath-hold (DIBH) radiotherapy to reduce cardiac exposure in patients with left-sided breast cancer is challenging with helical tomotherapy(HT) and has received little attention. We describe our novel approach to DIBH irradiation in HT using a specially designed frame and manual gating, and compare cardiac substructure doses with the free-breathing (FB) technique. Material and methods: The workflow incorporates staggered junctions and a frame that provides tactile feedback to the patient and monitoring for manual cut-off. The treatment parameters and clinical outcome of 20 patients with left-sided breast cancer who have undergone DIBH radiotherapy as a part of an ongoing prospective registry are reported. All patients underwent CT scans in Free Breathing (FB) and DIBH using the in-house Respiframe, which incorporates a tactile feedback-based system with an indicator pencil. Plans compared target coverage, cardiac doses, synchronizing treatment with breath-hold and avoiding junction repetition. MVCT scans are used for patient alignment. Results: The mean dose (Dmean) to the heart was reduced by an average of 34 % in DIBH-HT compared to FB-HT plans (3.8 Gy vs 5.7 Gy). Similarly, 32 % and 67.8 % dose reduction were noted in the maximum dose (D0.02 cc) of the left anterior descending artery, mean 12.3 Gy vs 18.1 Gy, and mean left ventricle V5Gy 13.2 % vs 41.1 %, respectively. The mean treatment duration was 451.5 sec with a median 8 breath-holds; 3 % junction locations between successive breath-holds were replicated. No locoregional or distant recurrences were observed in the 9-month median follow-up. Conclusion: Our workflow for DIBH with Helical-Tomotherapy addresses patient safety, treatment precision and challenges specific to this treatment unit. The workflow prevents junction issues by varying daily breath-hold durations and avoiding junction locations, providing a practical solution for left-sided breast cancer treatment with HT.

2.
World Neurosurg ; 185: e407-e414, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38360208

RESUMO

OBJECTIVE: We report our early clinical experience with image-guided, pencil beam scanning proton beam therapy (PBS-PBT) for residual and recurrent craniopharyngioma. METHODS: Between September 2019 and January 2023, 19 consecutive patients with residual or recurrent craniopharyngioma, suitable for radiotherapy and treated with image-guided PBS-PBT were analyzed. We documented detailed dosimetric data, acute toxicities, early outcomes, and imaging response on follow-up magnetic resonance imaging scans. RESULTS: A total of 19 patients (11 males and 8 females) with residual or recurrent craniopharyngioma were treated during the study period. The median age of the cohort was 14 years (range, 3-33 years). The histology of most lesions was the adamantinomatous subtype (95%). The most common clinical presentation (before PBT) and most common endocrine deficit was visual disturbance (79%) and hypocortisolism (74%), respectively. Of the 19 patients, 13 had recurrent craniopharyngioma, and 5 had undergone radiotherapy previously. Five patients (26%) had undergone surgery ≥3 times before proton therapy. The median dose delivered was 54 GyE. The most common acute toxicity was grade 1 alopecia (63%). No patient experienced grade ≥3 acute toxicity. With a median follow-up of 18 months (range, 3-40 months), 12 patients showed shrinkage of the residual tumor and/or cyst, and 4 showed a dramatic cyst reduction at 3-9 months of follow-up. Two patients experienced a reduction in both solid and cystic components, with the remaining experiencing a reduction in the cystic component only. The remaining 8 patients had stable disease on magnetic resonance imaging, with 100% disease control and overall survival. Visual function remained stable after treatment. CONCLUSIONS: Our preliminary experience with modern PBS-PBT and image guidance for craniopharyngioma is encouraging. Proton therapy in our cohort was well tolerated, resulting in limited toxicity and promising early outcomes.


Assuntos
Craniofaringioma , Neoplasias Hipofisárias , Terapia com Prótons , Humanos , Craniofaringioma/radioterapia , Craniofaringioma/diagnóstico por imagem , Feminino , Masculino , Terapia com Prótons/métodos , Adulto , Neoplasias Hipofisárias/radioterapia , Neoplasias Hipofisárias/diagnóstico por imagem , Neoplasias Hipofisárias/cirurgia , Adolescente , Criança , Adulto Jovem , Índia , Pré-Escolar , Recidiva Local de Neoplasia/radioterapia , Radioterapia Guiada por Imagem/métodos , Resultado do Tratamento , Imageamento por Ressonância Magnética
3.
Radiat Oncol J ; 41(2): 69-80, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37403349

RESUMO

PURPOSE: Indians have a higher incidence of cardiovascular diseases, often at a younger age, than other ethnic groups. This higher baseline risk requires consideration when assessing additional cardiac morbidity of breast cancer treatment. Superior cardiac sparing is a critical dosimetric advantage of proton therapy in breast cancer radiotherapy. We report here the heart and cardiac-substructure doses and early toxicities in breast cancer patients treated post-operatively with proton therapy in India's first proton therapy center. MATERIALS AND METHODS: We treated twenty breast cancer patients with intensity-modulated proton therapy (IMPT) from October 2019 to September 2022, eleven after breast conservation, nine following mastectomy, and appropriate systemic therapy, when indicated. The most prescribed dose was 40 GyE to the whole breast/chest wall and 48 GyE by simultaneous integrated boost to the tumor bed and 37.5 GyE to appropriate nodal volumes, delivered in 15 fractions. RESULTS: Adequate coverage was achieved for clinical target volume (breast/chest wall), i.e., CTV40, and regional nodes, with 99% of the targets receiving 95% of the prescribed dose (V95% > 99%). The mean heart dose was 0.78 GyE and 0.87 GyE for all and left breast cancer patients, respectively. The mean left anterior descending artery (LAD) dose, LAD D0.02cc, and left ventricle dose were 2.76, 6.46, and 0.2 GyE, respectively. Mean ipsilateral lung dose, V20Gy, V5Gy, and contralateral breast dose (Dmean) were 6.87 GyE, 14.6%, 36.4%, and 0.38 GyE, respectively. CONCLUSION: The dose to heart and cardiac substructures is lower with IMPT than published photon therapy data. Despite the limited access to proton therapy at present, given the higher cardiovascular risk and coronary artery disease prevalence in India, the cardiac sparing achieved using this technique merits consideration for wider adoption in breast cancer treatment.

4.
Radiat Oncol ; 18(1): 11, 2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36639667

RESUMO

Radiation dermatitis is a major concern in intensity modulated proton therapy (IMPT) for head and neck cancer (HNC) despite its demonstrated superiority over contemporary photon radiotherapy. In this study, dose surface histogram data extracted from forty-four patients of HNC treated with IMPT was used to predict the normal tissue complication probability (NTCP) of skin. Grades of NTCP-skin were clustered using the K-means clustering unsupervised machine learning (ML) algorithm. A new skin-sparing IMPT (IMPT-SS) planning strategy was developed with three major changes and prospectively implemented in twenty HNC patients. Across skin surfaces exposed from 10 (S10) to 70 (S70) GyRBE, the skin's NTCP demonstrated the strongest associations with S50 and S40 GyRBE (0.95 and 0.94). The increase in the NTCP of skin per unit GyRBE is 0.568 for skin exposed to 50 GyRBE as compared to 0.418 for 40 GyRBE. Three distinct clusters were formed, with 41% of patients in G1, 32% in G2, and 27% in G3. The average (± SD) generalised equivalent uniform dose for G1, G2, and G3 clusters was 26.54 ± 6.75, 38.73 ± 1.80, and 45.67 ± 2.20 GyRBE. The corresponding NTCP (%) were 4.97 ± 5.12, 48.12 ± 12.72 and 87.28 ± 7.73 respectively. In comparison to IMPT, new IMPT-SS plans significantly (P < 0.01) reduced SX GyRBE, gEUD, and associated NTCP-skin while maintaining identical dose volume indices for target and other organs at risk. The mean NTCP-skin value for IMPT-SS was 34% lower than that of IMPT. The dose to skin in patients treated prospectively for HNC was reduced by including gEUD for an acceptable radiation dermatitis determined from the local patient population using an unsupervised MLA in the spot map optimization of a new IMPT planning technique. However, the clinical finding of acute skin toxicity must also be related to the observed reduction in skin dose.


Assuntos
Neoplasias de Cabeça e Pescoço , Terapia com Prótons , Radiodermite , Radioterapia de Intensidade Modulada , Humanos , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/etiologia , Órgãos em Risco/efeitos da radiação , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Radiodermite/etiologia , Radiodermite/prevenção & controle , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Aprendizado de Máquina não Supervisionado
5.
JCO Glob Oncol ; 6: 1736-1745, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33180633

RESUMO

PURPOSE: Proton beam therapy (PBT) has been a preferred modality in pediatric malignancies requiring radiotherapy. We report our preliminary experience of treating consecutive patients younger than 25 years with image-guided pencil beam scanning PBT from the first and only center on the Indian subcontinent. METHODS: Patients were selected for PBT on the basis of a multidisciplinary tumor board decision. Patient demographic data, as well as tumor and treatment-related characteristics of the cohort, were captured. Patient and treatment-related factors and their association with acute toxicities were analyzed using univariable and multivariable analyses. RESULTS: Forty-seven patients (27 with CNS and 20 with non-CNS tumors) with a median age of 9 years (range, 2-25 years) were evaluated. Most common diagnoses were ependymoma, rhabdomyosarcoma, and glioma. Seventy-seven percent of patients traveled more than 500 km, and 70% of them lived in metropolitan cities. Forty-nine percent of patients had recurrent disease at presentation, and 15% had received a previous course of radiation. The median dose delivered was 54.8 cobalt gray equivalents (range, 40.0-70.4 cobalt gray equivalents) to a median clinical target volume of 175 mL (range, 18.7-3,083.0 mL), with 34% of patients requiring concurrent chemotherapy (CCT). Acute grade 2 and grade 3 dermatitis, mucositis, and hematologic toxicity was noted in 45% and 2%, 34% and 0%, and 38% and 30% of patients, respectively. Grade 2 fatigue was noted in 26% of patients. On multivariable analysis, for CNS tumors, both CCT and craniospinal irradiation were independently associated with ≥ 2 grade hematologic toxicity, whereas among non-CNS tumors, a clinical target volume > 150 mL was associated with ≥ 2 grade fatigue, head and neck irradiation was associated with ≥ 2 grade mucositis, and CCT was associated with grade ≥ 2 hematologic toxicity. CONCLUSION: This study demonstrates safe implementation of a PBT program for children and young adults on the Indian subcontinent. Image-guided pencil beam scanning PBT in judiciously selected patients is feasible and can be delivered with acceptable acute toxicities.


Assuntos
Radiação Cranioespinal , Ependimoma , Terapia com Prótons , Rabdomiossarcoma , Adolescente , Adulto , Criança , Pré-Escolar , Humanos , Índia , Terapia com Prótons/efeitos adversos , Adulto Jovem
7.
J Cancer Res Ther ; 15(3): 533-538, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31169216

RESUMO

INTRODUCTION AND OBJECTIVE: Anatomic and volumetric changes occur in head-and-neck cancer during fractionated radiotherapy (RT), and the actual dose received by patient is considerably different from the original plan. The purpose of this study is to evaluate volumetric and dosimetric changes occurring during radiation therapy. PATIENTS AND METHODS: Ten patients of locally advanced head-and-neck cancer, 6 oropharynx, 3 larynx, and 1 hypopharynx underwent computed tomography (CT) simulation before treatment and after 4 weeks during RT treatment. Original plan (OPLAN) was generated based on initial CT scan for the entire course of treatment. The initial plan is implemented on the second planning CT scan, and the dose distribution is recalculated. Beam configuration of OPLAN was applied onto the second CT scan and then hybrid plan (HPLAN30) was generated. RPLAN30 is the intensity-modulated RT replan generated on the second CT scan for the remaining 30 Gy. Dose and volume parameters between OPLAN30 (based on the first CT scan for the remaining 30 Gy), HPLAN30, and RPLAN30 were compared. RESULTS: The volume reduction of planning target volume (PTV), ipsilateral and contralateral parotid after 4 weeks of RT, was statistically significant (P < 0.05). D2% and V > 107% of PTV were higher in HPLAN than that of RPLAN (P < 0.05). Hybrid plans showed increase in delivered dose to spinal cord. Mid treatment replanning reduced doses to spinal cord (Dmax and D1%), which is statistically significant (P < 0.05). Mean doses to ipsilateral and contralateral parotid of RPLAN (21.4 Gy and 16.74 Gy, respectively) were reduced when compared to that of HPLAN (22.99 Gy and 22 Gy, respectively). CONCLUSION: Interim CT scanning and replanning (adaptive) improves target volume coverage and normal tissue sparing.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia de Intensidade Modulada , Idoso , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Órgãos em Risco , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
J Cancer Res Ther ; 13(1): 131-136, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28508846

RESUMO

PURPOSE: To achieve the best possible therapeutic ratio using high-precision techniques (image-guided radiation therapy/volumetric modulated arc therapy [IGRT/VMAT]) of external beam radiation therapy in cases of carcinoma cervix using kilovoltage cone-beam computed tomography (kV-CBCT). MATERIALS AND METHODS: One hundred and five patients of gynecological malignancies who were treated with IGRT (IGRT/VMAT) were included in the study. CBCT was done once a week for intensity-modulated radiation therapy and daily in IGRT/VMAT. These images were registered with the planning CT scan images and translational errors were applied and recorded. In all, 2078 CBCT images were studied. The margins of planning target volume were calculated from the variations in the setup. RESULTS: The setup variation was 5.8, 10.3, and 5.6 mm in anteroposterior, superoinferior, and mediolateral direction. This allowed adequate dose delivery to the clinical target volume and the sparing of organ at risks. CONCLUSION: Daily kV-CBCT is a satisfactory method of accurate patient positioning in treating gynecological cancers with high-precision techniques. This resulted in avoiding geographic miss.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radioterapia de Intensidade Modulada/métodos , Neoplasias do Colo do Útero/radioterapia , Neoplasias Uterinas/radioterapia , Fracionamento da Dose de Radiação , Feminino , Humanos , Posicionamento do Paciente , Pelve/diagnóstico por imagem , Pelve/patologia , Pelve/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...