Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
Clin Exp Allergy ; 45(1): 154-63, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25200568

RESUMO

BACKGROUND: Infancy is a developmental stage with heightened susceptibility to environmental influences on the risk of chronic childhood disease. Few birth cohort studies have detailed measures of fungal diversity data in infants' bedrooms, limiting the potential to measure long-term associations of these complex exposures with development of asthma or allergy. OBJECTIVE: We evaluated the relation of home fungal levels in infancy to repeated measures of wheeze and development of asthma and rhinitis by age 13, and sensitization by age 12 years. METHODS: In the Epidemiology of Home Allergens and Asthma prospective birth cohort study, we recruited 408 children with family history of allergic disease or asthma. When children were aged 2-3 months, we measured culturable fungi in bedroom air and dust, and in outdoor air. Main outcomes included ascertainment of symptoms/disease onset by questionnaire from birth through age 13. We estimated hazard ratios and, for wheeze and sensitization, odds ratios for an interquartile increase in log-transformed fungal concentrations, adjusting for other outcome predictors and potential confounders. RESULTS: Elevated levels of yeasts in bedroom floor dust were associated with reduced: i) wheeze at any age; ii) fungal sensitization; and iii) asthma development by age 13 (hazard ratio (HR) = 0.86; 95% confidence interval (CI), [0.75 to 0.98]). Outdoor airborne Cladosporium and dustborne Aspergillus predicted increased rhinitis. Risk of fungal sensitization by age 12, in response to environmental Alternaria and Aspergillus, was elevated in children with a maternal history of fungal sensitization. CONCLUSIONS AND CLINICAL RELEVANCE: Despite the irritant and allergenic properties of fungi, early-life elevated dust yeast exposures or their components may be protective against allergy and asthma in children at risk for these outcomes. Ascertainment of fungal components associated with immunoprotective effects may have therapeutic relevance for asthma.


Assuntos
Poluição do Ar em Ambientes Fechados , Asma , Fungos , Asma/epidemiologia , Asma/etiologia , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos
2.
Allergy ; 68(11): 1410-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24118031

RESUMO

BACKGROUND: While fungal exposures are assumed to provoke wheeze through irritant or allergenic mechanisms, little is known about the differential effects of indoor and outdoor fungi on early-life wheeze. METHODS: In a Boston prospective birth cohort of 499 at-risk infants, culturable fungi in bedroom air and dust and outdoor air were measured at the age of 2-3 months. Wheeze was determined using bimonthly telephone questionnaires. Odds ratios were estimated for an interquartile increase in fungal natural log-transformed concentrations, adjusting for predictors of wheeze and potential confounders. RESULTS: Increased odds of 'any wheeze' (≥1 vs 0 episodes) by age one were positively associated with indoor dust Alternaria [odds ratio (OR) = 1.83; 95% confidence interval (CI), 1.07-3.14], Penicillium [OR = 1.18; (0.98-1.43)], and Cladosporium [OR = 1.47; (1.16-1.85)]; indoor air Penicillium [OR = 1.26; (0.92-1.74)]; and outdoor air Cladosporium [OR = 1.68; (1.04-2.72)]. In contrast, indoor dust yeasts were protective [OR = 0.78; (0.66-0.93)]. 'Frequent wheeze' (≥2 vs <2 episodes) by age one was borderline associated with dust yeasts [OR = 0.86; (0.70-1.04)] and indoor air yeasts [OR = 1.53; (0.93-2.53)]. Alternaria concentration was associated with any wheeze for children with maternal mold sensitization [OR = 9.16; (1.37-61.22)], but not for those without maternal mold sensitization [OR = 1.32; (0.79-2.20)]. CONCLUSIONS: While wheeze rates were higher with exposures to fungal taxa considered to be irritant or allergenic in sensitive subjects, yeasts in the home had a strong protective association with wheeze in infancy. Molecular microbiologic studies may elucidate specific components of innate microbiologic stimulants that lead to contrasting effects on wheeze development.


Assuntos
Poluição do Ar em Ambientes Fechados/efeitos adversos , Antígenos de Fungos/imunologia , Poeira/imunologia , Sons Respiratórios/imunologia , Alternaria/imunologia , Animais , Antígenos de Fungos/administração & dosagem , Aspergillus/imunologia , Blattellidae/imunologia , Cladosporium/imunologia , Feminino , Humanos , Lactente , Penicillium/imunologia , Valor Preditivo dos Testes , Estudos Prospectivos , Hipersensibilidade Respiratória/diagnóstico , Hipersensibilidade Respiratória/imunologia , Hipersensibilidade Respiratória/microbiologia , Sons Respiratórios/diagnóstico , Medição de Risco
3.
Indoor Air ; 18(4): 335-45, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18717984

RESUMO

UNLABELLED: In order to develop baseline data about United States office buildings, the United States Environmental Protection Agency conducted the Building Assessment Survey Evaluation (BASE) study, a systematic survey of 100 randomly selected United States office buildings, in the 1990s. This paper analyzes the self-reported work-related symptoms and job and workplace characteristics of 4326 respondents and compares results to the National Institute for Occupational Safety and Health's (NIOSH) study of 80 'complaint' buildings. Four distinct groups of symptoms, representing 'tiredness', 'mucosal irritation', 'neuropsychological', and 'lower respiratory' conditions emerged from factor analysis of work-related symptoms. The symptom grouping is identical for both surveys. Although the prevalence of each symptom is significantly higher in the NIOSH than in the BASE sample, there is overlap of the symptom distributions. In the BASE survey, 45% of the work force reported at least one work-related health symptom; 20% reported at least three symptoms. These findings imply that it is counterproductive to dichotomize buildings into healthy vs. unhealthy; instead the prevalence of health problems related to buildings span a continuum. PRACTICAL IMPLICATIONS: These results indicate that most office buildings have occupants who report building-related symptoms. This paper provides practical guidance for the comparison of building prevalences to the BASE normative data. Work-related symptom distributions and symptom groups can improve investigators' ability to identify IEQ problems.


Assuntos
Exposição Ocupacional/efeitos adversos , Síndrome do Edifício Doente/complicações , Adulto , Coleta de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/análise , Estados Unidos , United States Environmental Protection Agency
4.
Indoor Air ; 14(6): 434-8, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15500637

RESUMO

UNLABELLED: The purpose of this study was to evaluate the effects of furniture polish (FP) on the release of cat allergen (Fel d 1)-laden dust from wood surfaces and decay of Fel d 1 in dust over time. About 2 g of sieved (150 microm screen) allergen-laden dust was introduced as an aerosol into an experimental chamber by a Pitt-3 generator and allowed to settle onto two finished wood surfaces pre-treated with either distilled water (DW) or FP. After 24 h, each surface was vacuumed into separate plastic cassettes loaded with 37 mm diameter, 0.4 microm pore, polycarbonate filters. The recovered dust was weighed, extracted in phosphate-buffered saline, and assayed for Fel d 1 content using a two-site monoclonal antibody ELISA. After vacuuming, the remaining dust on the wood surfaces was wiped up with a water-moistened swab. The dusts were extracted from the swabs and assayed by ELISA for Fel d 1. More Fel d 1 was recovered by vacuuming from DW-pre-treated surfaces than from FP pre-treated surfaces (100% vs. 69 +/- 66%). On the contrary, more residual Fel d 1 (>99.9%) on the vacuumed surfaces was recovered from FP than from DW pre-treated surfaces by wet swabs. The concentration of Fel d 1 in dust did not change significantly at room temperature over 80 days. In conclusion, FP on wood surfaces makes dust stick to the surface, which likely reduces the release of allergen-laden dust from the wood surface. PRACTICAL IMPLICATIONS: Re-aerosolization of cat allergen-laden dusts from wood surfaces (e.g. wood floor or furniture) significantly increases the concentration of airborne cat allergens. Our study indicates that exposure to airborne cat allergens might be reduced by surface treatment with commercially available FP because cat allergen-laden dusts stuck more tightly to the wood surface treated with FP.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Poeira/análise , Glicoproteínas/análise , Madeira , Animais , Gatos , Exposição Ambiental/análise , Monitoramento Ambiental/métodos , Humanos
5.
Allergy ; 58(1): 13-20, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12580801

RESUMO

BACKGROUND: Exposure to fungi is often assessed by culturing floor dust or air samples. Our objective was to evaluate the relationships between dustborne and airborne fungi and to identify factors that modify these relationships. METHODS: From November 1994 to September 1996 sequential duplicate 45-l air samples were collected in bedrooms of 496 homes in the Boston area, using a Burkard culture plate sampler. After air sampling, bedroom floors were sampled with a vacuum cleaner that was modified to collect dust in a cellulose extraction thimble. Dust was sieved, and the fine dust was dilution-plated onto DG-18 media. RESULTS: Concentrations of total culturable fungi per gram of bedroom-floor dust were correlated weakly, but significantly, with those of indoor air (r = 0.13, P < 0.05). Concentrations of some individual taxa in the dust and indoor air were also weakly associated. Adjusting for the concentrations of fungi in outdoor air, dustborne fungal concentrations were positively associated with those in indoor air for the taxa Cladosporium and Penicillium, but not for total fungi. The indoor air fungal levels were often predicted by different covariates to those predicting fungal levels in dust. The type of housing (house or apartment) and the presence of carpeting were often predictive factors for dust fungi. In contrast, outdoor fungal levels were often predictive of the indoor air fungal levels. CONCLUSIONS: Because our data do not indicate a strong overall relationship between culturable fungi in dust and indoor air, the results from these two methods (dust and air sampling) likely represent different types of potential fungal exposures to residents. It may be essential to collect both air and dust samples, as well as information on housing characteristics, as indicators for fungal exposure.


Assuntos
Poluentes Atmosféricos/análise , Poluentes Atmosféricos/classificação , Poluição do Ar em Ambientes Fechados/análise , Poeira/análise , Fungos/classificação , Animais , Boston , Estudos de Coortes , Cães , Pisos e Cobertura de Pisos/classificação , Seguimentos , Humanos , Umidade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Estações do Ano , Estatística como Assunto
6.
Risk Anal ; 21(4): 657-73, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11726019

RESUMO

Environmental control measures (ventilation, high-efficiency particulate air filtration, and upper room ultraviolet germicidal irradiation [UVGI]) are recommended to effectively control tuberculosis (TB) transmission from unsuspected TB patients in high-risk settings, but the effectiveness of their use is not often clear. This study presents a simulation model for a hypothetical hospital waiting room, in which the number of susceptible immunocompetent people in the waiting room follows a Poisson distribution (M = 5) in either low (annual number of TB patients = 5) or high TB risk settings (annual number of TB patients = 50), and used the model to evaluate the reduction of TB transmission risk by upper room UVGI. An exponential dose-response model was used for TB transmission and a two-zone model was used for evaluating the effect of upper room UVGI. Upper room UVGI reduced TB risk by 1.6-fold at 3 microW/cm2 UV irradiance in the upper room in the low TB risk setting and by 4.1-fold at 15 microW/cm2 UV irradiance in the upper room in the high TB risk setting. Use of upper room UVGI also reduced the mean annual new infection rate from 2.2 to 1.3 infections per year at 3 microW/cm2 and to 0.6 infections per year at 15 microW/cm2 in our hypothetical high-risk settings. The effect of upper room UVGI was sensitive to both vertical air velocity (air mixing) and UV irradiance level. Results from partitioning variability indicate that most variability of TB transmission risk came from waiting time in our hypothetical hospital.


Assuntos
Transmissão de Doença Infecciosa/prevenção & controle , Ambiente Controlado , Ambiente de Instituições de Saúde , Modelos Teóricos , Tuberculose/epidemiologia , Raios Ultravioleta , Simulação por Computador , Análise Custo-Benefício , Humanos , Incidência , Risco
7.
Environ Health Perspect ; 109(8): 815-9, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11564617

RESUMO

House dust mite allergen exposure is a postulated risk factor for allergic sensitization, asthma development, and asthma morbidity; however, practical and effective methods to mitigate these allergens from low-income, urban home environments remain elusive. The purpose of this study was to assess the feasibility and effectiveness of physical interventions to mitigate house dust mite allergens in this setting. Homes with high levels of house dust mite allergen (Der f 1 + Der p 1 > or = 10 microg/g dust by enzyme-linked immunosorbent assay) in the bed, bedroom carpet, and/or upholstered furniture were enrolled in the study. Carpets and upholstered furniture were subjected to a single treatment of either dry steam cleaning plus vacuuming (carpet only) or intensive vacuuming alone. Bed interventions consisted of complete encasement of the mattress, box spring, and pillows plus either weekly professional or in-home laundering of nonencased bedding. Dust samples were collected at baseline and again at 3 days (carpet and upholstery only) and 2, 4, and 8 weeks posttreatment. We compared pretreatment mean allergen concentrations and loads to posttreatment values and performed between-group analyses after adjusting for differences in the pretreatment means. Both dry steam cleaning plus vacuuming and vacuuming alone resulted in a significant reduction in carpet house dust mite allergen concentration and load (p < 0.05). Levels approached pretreatment values by 4 weeks posttreatment in the intensive vacuuming group, whereas steam cleaning plus vacuuming effected a decrease that persisted for up to 8 weeks. Significant decreases in bed house dust mite allergen concentration and load were obtained in response to encasement and either professional or in-home laundering (p < 0.001). Between-group analysis revealed significantly less postintervention house dust mite allergen load in professionally laundered compared to home-laundered beds (p < 0.05). Intensive vacuuming and dry steam cleaning both caused a significant reduction in allergen concentration and load in upholstered furniture samples (p < 0.005). Based on these data, we conclude that physical interventions offer practical, effective means of reducing house dust mite allergen levels in low-income, urban home environments.


Assuntos
Alérgenos/análise , Poeira/análise , Exposição Ambiental/prevenção & controle , Habitação , Hipersensibilidade/prevenção & controle , Ácaros/imunologia , Animais , Roupas de Cama, Mesa e Banho , Poeira/efeitos adversos , Pisos e Cobertura de Pisos , Zeladoria/métodos , Humanos , Decoração de Interiores e Mobiliário , Lavanderia/métodos , Pobreza , População Urbana , Washington
8.
Environ Health Perspect ; 109(8): 859-64, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11564624

RESUMO

We identified home characteristics associated with the level of airborne endotoxin in 111 Boston-area homes enrolled in a cohort study of home exposures and childhood asthma, and we developed a predictive model to estimate airborne endotoxin. We measured endotoxin in family-room air and in dust from the baby's bed, family room, bedroom, and kitchen floor. Level of airborne endotoxin was weakly correlated (r < 0.3) with level of endotoxin in each of the four types of dust samples and was significantly correlated with endotoxin in family-room dust (p < 0.05). Endotoxin in family-room dust accounted for < 6% of the variability of airborne endotoxin. In a multivariate model, certain home characteristics were positively (p < 0.05) associated with airborne endotoxin. These included current presence of dog (difference in level, dog vs. no dog = 72%, partial R(2 )= 12.8%), past presence of dog (partial R(2) = 5.5%), and endotoxin level in family-room dust (partial R(2) = 5.3%). Use of a dehumidifier (partial R(2) = 6.4%) was negatively associated (p = 0.02; difference = -31%) with airborne endotoxin. Other home characteristics were identified as important determinants of increased airborne endotoxin in this model, but individual coefficients were not statistically significant (alpha = 0.05): total amount of fine dust collected in the home (partial R(2 )= 3.8%), concrete floor in family room (3.7%), water damage (3.6%), and use of cool-mist humidifier in past year (2.7%). This multivariate model explained 42% of the variability of airborne endotoxin levels, a substantial improvement over that with dust endotoxin alone. Airborne endotoxin in Boston-area homes appears to be determined by the presence of dogs, moisture sources, and increased amounts of settled dust.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Alérgenos/análise , Endotoxinas/análise , Monitoramento Ambiental/métodos , Habitação , Modelos Estatísticos , Alérgenos/efeitos adversos , Animais , Animais Domésticos , Asma/epidemiologia , Asma/microbiologia , Gatos , Cães , Poeira/análise , Endotoxinas/efeitos adversos , Monitoramento Epidemiológico , Humanos , Umidade , Hipersensibilidade/epidemiologia , Hipersensibilidade/microbiologia , Lactente , Estudos Longitudinais , Massachusetts/epidemiologia , Camundongos , Análise Multivariada , Valor Preditivo dos Testes , Análise de Regressão , Estações do Ano , Poluição por Fumaça de Tabaco
9.
Am J Respir Crit Care Med ; 163(2): 322-8, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11179100

RESUMO

We examined endotoxin exposure and wheezing episodes during the first year of life in a birth cohort of 499 infants with one or both parents having a history of asthma or allergy. We measured endotoxin in settled dust from the baby's bed, bedroom floor, family room, and kitchen floor within the first 3 mo after birth. The primary outcomes were any wheeze (versus no wheeze), and repeated wheeze (versus one or no report of wheeze). We found a significant univariate association of elevated endotoxin (> or = 100 EU/ mg) in family room dust with increased risk of any wheeze (Relative Risk = 1.29, 95% CI = 1.03-1.62). The association was not confounded by cockroach allergen, lower respiratory illness (croup, bronchitis, bronchiolitis, and pneumonia), smoking during pregnancy, lower birth weight, maternal asthma, presence of dog, and race/ethnicity in a multivariate model; the multivariate relative risk (RR = 1.33) was marginally significant (95% CI: 1.00-1.76, p < 0.05). In a multivariate model, controlling for the above covariates, elevated endotoxin in family room dust was significantly associated with increased risk (RR = 1.56, 95% CI = 1.03-2.38) of repeated wheeze. These results suggest that home endotoxin exposure may independently increase risk of any wheeze and repeated wheeze during the first year of life for children with a familial predisposition to asthma or allergy.


Assuntos
Poeira/efeitos adversos , Endotoxinas/efeitos adversos , Sons Respiratórios/etiologia , Alérgenos/efeitos adversos , Asma/genética , Estudos de Coortes , Feminino , Predisposição Genética para Doença , Humanos , Lactente , Recém-Nascido , Masculino , Gravidez , Fatores de Risco
10.
J Allergy Clin Immunol ; 107(1): 41-7, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11149989

RESUMO

BACKGROUND: Indoor inhaled allergens have been repeatedly demonstrated to worsen asthma in sensitized individuals, but their role in incident asthma is more controversial. OBJECTIVE: We investigated the relationship between exposure to allergens (dust mite, cat, and cockroach) measured in the home and incident doctor-diagnosed asthma and recurrent wheezing in children born to parents with asthma, allergies, or both. METHODS: From an ongoing longitudinal family and birth cohort study, we identified 222 siblings (median age, 2.87 years) of the index children. Allergen levels in the home were measured from dust samples obtained at the beginning of the study. Incident doctor-diagnosed asthma and recurrent wheezing were determined from questionnaires administered at 14 months and 22 months after the initial questionnaire. RESULTS: Thirteen (5.9%) children were reported to have incident asthma, twenty (9.0%) children had recurrent asthmatic wheezing, and 18 (8.1%) had recurrent wheezing without asthma. Compared with children living in homes with Bla g 1 or 2 levels of less than 0.05 U/g, children exposed to Bla g 1 or 2 levels of 0.05 to less than 2 U/g had a relative risk for incident asthma of 8.27 (95% confidence interval, 1.04-66.04), whereas children exposed to Bla g 1 or 2 levels of 2 U/g or greater had a relative risk for incident asthma of 35.87 (95% confidence interval, 4.49-286.62). Cockroach allergen exposure was likewise a significant predictor for recurrent asthmatic wheezing. Neither dust mite nor cat allergen levels were significantly associated with either outcome. These findings remained after control for several covariates. CONCLUSION: Exposure to cockroach allergen early in life may contribute to the development of asthma in susceptible children.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Alérgenos/análise , Asma/diagnóstico , Sons Respiratórios/diagnóstico , Análise de Variância , Animais , Antígenos de Plantas , Pré-Escolar , Baratas/imunologia , Feminino , Humanos , Lactente , Masculino
11.
Ann Allergy Asthma Immunol ; 87(6 Suppl 3): 52-6, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11770685

RESUMO

OBJECTIVES: This discussion is focused on the many roles of fungi in human health, and also to put the mycotoxin literature into perspective. DATA SOURCES: Data are derived from the literature referenced in PubMed from the National Library of Medicine, earlier references in the authors' reprint collection, and ongoing research. Studies for review were either selected from the peer-reviewed literature or from standard texts that are well recognized in the field. RESULTS: The review yielded many studies of the role of fungi in allergic disease, but none that systematically documented such a role for mycotoxins or fungal volatiles. Many case studies were found, but none of these unequivocally document a cause/effect relationship between mycotoxin exposure by inhalation and human disease in residential, school, or office settings. CONCLUSIONS: The review led to the conclusion that that the primary result from fungal exposure is allergic disease, and that the evidence for inhalation disease resulting from mycotoxin exposure in residential and office settings is extremely weak.


Assuntos
Alérgenos/efeitos adversos , Fungos/imunologia , Fungos/metabolismo , Hipersensibilidade/etiologia , Micotoxinas/efeitos adversos , Administração por Inalação , Alérgenos/imunologia , Humanos , Micotoxinas/imunologia , Esporos Fúngicos/imunologia
12.
Environ Health Perspect ; 108(11): 1023-8, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11102291

RESUMO

To characterize the seasonal variability of endotoxin levels, we measured endotoxin in dust from the bed, bedroom floor, and kitchen floor in 20 homes, and in air from the bedroom in 15 of the homes. All homes were located in the greater Boston, Massachusetts, area and were sampled each month from April 1995 to June 1996. Outdoor air was collected at two locations. We found greater within-home than between-home variance for bedroom floor, kitchen floor, and airborne endotoxin. However, the reverse was true for bed dust endotoxin. Thus, studies using single measurements of dust endotoxin are most likely to reliably distinguish between homes if bed dust is sampled. Dust endotoxin levels were not significantly associated with airborne endotoxin. Airborne endotoxin was significantly (p = 0. 04) and positively associated with absolute humidity in a mixed-effect model adjusting for a random home effect and fixed effect of sampling month and home characteristics. This finding implies that indoor humidity may be an important factor controlling endotoxin exposure. We found a significant (p < 0.05) seasonal effect in kitchen floor dust (spring > fall) and bedroom airborne endotoxin (spring > winter), but not in the other indoor samples. We found significant seasonal pattern in outdoor airborne endotoxin (summer > winter).


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Poeira/análise , Endotoxinas/análise , Análise de Variância , Boston , Clima , Exposição Ambiental , Saúde Ambiental , Habitação , Humanos , Umidade , Estações do Ano
13.
Tuber Lung Dis ; 80(4-5): 217-28, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11052911

RESUMO

SETTING: A study of Serratia marcescens and BCG aerosols. OBJECTIVE: To evaluate the effect of relative humidity (RH) on (1) the particle size and (2) sensitivity of 254nm germicidal ultraviolet (UV) irradiation. METHODS: We built a RH controlled experimental chamber into which bacteria were aerosolized, exposed to varying amounts of UV irradiance over measured time periods, and quantitatively evaluated for viability. Aerosolized Serratia marcescens and bacille Calmette-Guérin (BCG) were subject to UV doses ranging from 57-829 microW. sec/cm(2), and sampled with a six-stage Andersen culture plate impactor at RHs ranging from 25-95%. RESULTS: Percent survival for both organisms was inversely related to UV dose. Serratia marcescens was more susceptible to UV than BCG under all conditions. More than 95% of the bacterial aerosol particles were 1.1-4.7 microm in aerodynamic diameter, and particles sizes increased from low (25-36%) to high (85-95%) RH. The count median diameter ranged from 1.9-2.6 microm for Serratia marcescens and from 2.2-2.7 microm for BCG as RH increased. For both Serratia marcescens and BCG, resistance to UV increased as RH increased. The UV resistance of both Serratia marcescens and BCG aerosols dramatically increased at RH higher than 85%. CONCLUSIONS: Our results indicate that differences in UV dose, kinds of microorganisms, airborne particle size and RH affect UV susceptibility.


Assuntos
Umidade , Mycobacterium bovis/efeitos da radiação , Serratia marcescens/efeitos da radiação , Raios Ultravioleta , Aerossóis , Animais , Relação Dose-Resposta à Radiação , Tamanho da Partícula , Tolerância a Radiação
14.
Environ Health Perspect ; 108 Suppl 4: 653-9, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10931783

RESUMO

Outdoor allergens are an important part of the exposures that lead to allergic disease. Understanding the role of outdoor allergens requires a knowledge of the nature of outdoor allergen-bearing particles, the distributions of their source, and the nature of the aerosols (particle types, sizes, dynamics of concentrations). Primary sources for outdoor allergens include vascular plants (pollen, fern spores, soy dust), and fungi (spores, hyphae). Nonvascular plants, algae, and arthropods contribute small numbers of allergen-bearing particles. Particles are released from sources into the air by wind, rain, mechanical disturbance, or active discharge mechanisms. Once airborne, they follow the physical laws that apply to all airborne particles. Although some outdoor allergens penetrate indoor spaces, exposure occurs mostly outdoors. Even short-term peak outdoor exposures can be important in eliciting acute symptoms. Monitoring of airborne biological particles is usually by particle impaction and microscopic examination. Centrally located monitoring stations give regional-scale measurements for aeroallergen levels. Evidence for the role of outdoor allergens in allergic rhinitis is strong and is rapidly increasing for a role in asthma. Pollen and fungal spore exposures have both been implicated in acute exacerbations of asthma, and sensitivity to some fungal spores predicts the existence of asthma. Synergism and/or antagonism probably occurs with other outdoor air particles and gases. Control involves avoidance of exposure (staying indoors, preventing entry of outdoor aerosols) as well as immunotherapy, which is effective for pollen but of limited effect for spores. Outdoor allergens have been the subject of only limited studies with respect to the epidemiology of asthma. Much remains to be studied with respect to prevalence patterns, exposure and disease relationships, and control.


Assuntos
Poluentes Atmosféricos/efeitos adversos , Alérgenos/efeitos adversos , Asma/etiologia , Exposição por Inalação/efeitos adversos , Humanos , Modelos Teóricos , Pólen , Esporos Fúngicos
15.
Appl Environ Microbiol ; 66(7): 2817-21, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10877773

RESUMO

The fungus Stachybotrys chartarum has been implicated in cases of nonspecific indoor air quality complaints in adults and in cases of pulmonary hemorrhaging in infants. The effects that have been described have been attributed to mycotoxins. Previous dose-effect studies focused on exposure to a single mycotoxin in a solvent, a strategy which is unlikely to accurately characterize the effects of inhaled spores. In this study we examined the role of mycotoxins in the pulmonary effects caused by S. chartarum spores and the dose dependency of these effects. S. chartarum spores were extracted in methanol to reduce the mycotoxin content of the spores. Then either untreated (toxin-containing) or methanol-extracted S. chartarum spores were intratracheally instilled into male 10-week-old Charles River-Dawley rats. After 24 h, the lungs were lavaged, and the bronchoalveolar lavage fluid was analyzed to determine differences in lactic dehydrogenase, albumin, hemoglobin, myeloperoxidase, and leukocyte differential counts. Weight change was also monitored. Our data show that methanol extraction dramatically reduced the toxicity of S. chartarum spores. No statistically significant effects were observed in the bronchoalveolar lavage fluids of the animals that were treated with methanol-extracted spores at any dose. Conversely, dose-dependent effects of the toxin-containing spores were observed when we examined the lactic dehydrogenase, albumin, and hemoglobin concentrations, the polymorphonuclear leukocyte counts, and weight loss. Our findings show that a single, intense exposure to toxin-containing S. chartarum spores results in pulmonary inflammation and injury in a dose-dependent manner. Importantly, the effects are related to methanol-soluble toxins in the spores.


Assuntos
Pneumopatias Fúngicas/patologia , Pulmão/patologia , Micotoxinas/toxicidade , Stachybotrys/patogenicidade , Animais , Líquido da Lavagem Broncoalveolar/citologia , Inflamação , Pulmão/microbiologia , Pneumopatias Fúngicas/microbiologia , Masculino , Metanol/química , Micotoxinas/química , Ratos , Esporos Fúngicos/química , Esporos Fúngicos/patogenicidade , Esporos Fúngicos/fisiologia , Stachybotrys/metabolismo
16.
Appl Occup Environ Hyg ; 15(6): 492-502, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10853290

RESUMO

Although metalworking fluids have been widely used throughout industry for decades, occupational exposures to metalworking fluid aerosols and their constituents have not been well characterized. This article describes an exposure assessment for a study of metalworking fluid aerosols and acute respiratory effects. This exposure assessment was unique in its inclusion of multiple exposure measures relevant to a complex environment, and extensive personal sampling for bacteria and endotoxin. The specific objectives were to: (1) obtain indices of personal exposure to metalworking fluid aerosols in an automotive transmission plant, either directly (by sampling) or indirectly (by estimation), and (2) identify and adjust for sources of error in exposure/dose measures, where possible. No prior studies have characterized personal exposures to metalworking fluid aerosols so extensively. Exposure data were obtained during a pilot phase and three principal rounds of data collection over a 15-month period in conjunction with spirometric testing. Subjects worked in one of two machining departments, Case and Valve Body, or in a comparison department, Final Assembly. The primary exposure measures for this study were thoracic fraction particulate, thoracic fraction bacteria (viable plus non-viable), and total endotoxin. Mean personal air concentrations of thoracic particulate across all study rounds were 0.13 mg/m3 in Final Assembly, 0.32 mg/m3 in Valve Body, and 0.56 mg/m3 in Case. Average personal exposures to thoracic fraction bacteria were 0.38 bacteria/cc in Final Assembly, 0.87 bacteria/cc in Valve Body, and 2.66 bacteria/cc in Case. Average personal endotoxin measurements, collected in Round 3 of the study, were 16.4 endotoxin units (EU)/m3 in Assembly, 34.7 EU/m3 in Valve Body, and 234 EU/m3 in Case. Sump fluid contained on the order of 10(8) bacteria/ml, and 10(4)-10(5) EU/ml. Air concentrations of thoracic particulate, thoracic bacteria, and total endotoxin were highly correlated in metalworking operations. Thus, reducing airborne particulate levels should also reduce ambient bacteria and endotoxin, which are suspect agents of respiratory impairment. The elevated endotoxin levels in Final Assembly were unexpected, and suggest an independent source of endotoxin contamination in this department.


Assuntos
Monitoramento Ambiental/métodos , Substâncias Perigosas/análise , Metalurgia , Doenças Profissionais/prevenção & controle , Exposição Ocupacional/análise , Infecções Respiratórias/prevenção & controle , Doença Aguda , Aerossóis/efeitos adversos , Aerossóis/análise , Microbiologia do Ar , Análise de Variância , Espaços Confinados , Endotoxinas/análise , Estudos de Avaliação como Assunto , Feminino , Substâncias Perigosas/efeitos adversos , Humanos , Modelos Lineares , Masculino , Doenças Profissionais/etiologia , Exposição Ocupacional/efeitos adversos , Tamanho da Partícula , Infecções Respiratórias/etiologia , Fatores de Risco , Estudos de Amostragem
17.
J Allergy Clin Immunol ; 105(5): 933-42, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10808174

RESUMO

BACKGROUND: Allergic asthma is a common childhood disease. Although T-lymphocyte activation plays a critical role in allergic asthma, the environmental factors promoting lymphocyte activation in children are not well defined. OBJECTIVE: In a cohort of children at risk for asthma (n = 114), we determined whether the levels of cockroach (Bla g 1 or 2), house dust mite (Der f 1), and cat allergen (Fel d 1) in the home during infancy was associated with subsequent allergen-specific lymphocyte proliferation in later life. METHODS: Dust samples from multiple sites in the home were collected at 3 months of age and were measured for allergen levels. Serial questionnaires were applied. At a median age of 2 years, PBMCs were isolated and lymphocyte proliferation to the home allergens and PHA was determined. RESULTS: Increased lymphocyte proliferative responses to Bla g 2 were associated with higher home levels of Bla g 1 or 2 (P for trend with kitchen Bla g levels =.011), in analyses adjusting for cold in the past week. Proliferative responses to Der f 1 were higher in homes with family room levels of Der f 1 > or =10 microg/g dust than in homes with Der f 1 <2 microg/g, but differences were not significant in analyses adjusting for cold (P =. 15). Repeated wheeze in the first 2 years of life was associated with increased allergen-specific and PHA proliferative responses. CONCLUSION: Early-life cockroach allergen exposure at 3 months of age predicts allergen-specific lymphocyte proliferative responses at a median of 2 years of age.


Assuntos
Asma/epidemiologia , Poluição do Ar em Ambientes Fechados/análise , Alérgenos/análise , Antígenos de Dermatophagoides , Ácido Aspártico Endopeptidases/imunologia , Criança , Pré-Escolar , Estudos de Coortes , Glicoproteínas/imunologia , Humanos , Lactente , Estudos Longitudinais , Ativação Linfocitária , Análise Multivariada , Sons Respiratórios/imunologia , Fatores de Risco
18.
Environ Health Perspect ; 108(4): 301-7, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10753087

RESUMO

In the United States, childhood asthma morbidity and prevalence rates are the highest in less affluent urban minority communities. More than 80% of childhood asthmatics are allergic to one or more inhalant allergens. We evaluated whether socioeconomic status was associated with a differential in the levels and types of indoor home allergens. Dust samples for an ELISA allergen assay were collected from the homes of 499 families as part of a metropolitan Boston, Massachusetts, longitudinal birth cohort study of home allergens and asthma in children with a parental history of asthma or allergy. The proportion of homes with maximum home allergen levels in the highest category was 42% for dust mite allergen (> or = 10 microg/g Der p 1 or Der f 1), 13% for cockroach allergen (> or = 2 U/g Bla g 1 or Bla g 2), 26% for cat allergen (> or = 8 microg/g Fel d 1), and 20% for dog allergen (> or = 10 microg/g Can f 1). Homes in the high-poverty area (> 20% of the population below the poverty level) were more likely to have high cockroach allergen levels than homes in the low-poverty area [51 vs. 3%; OR, 33; 95% confidence interval (CI), 12-90], but less likely to have high levels of dust mite allergen (16 vs. 53%; OR, 0.2; CI, 0.1-0.4). Lower family income, less maternal education, and race/ethnicity (black or Hispanic vs. white) were also associated with a lower risk of high dust mite levels and a greater risk of high cockroach allergen levels. Within a single U.S. metropolitan area we found marked between-community differences in the types of allergens present in the home, but not necessarily in the overall burden of allergen exposure.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Alérgenos/análise , Habitação/economia , Pobreza , Adulto , Poluição do Ar em Ambientes Fechados/economia , Animais , Asma/etiologia , Boston , Gatos , Criança , Pré-Escolar , Baratas , Cães , Poeira , Feminino , Humanos , Renda , Masculino , Ácaros , Fatores de Risco , Classe Social
19.
Mycopathologia ; 149(1): 27-34, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11227851

RESUMO

Stachybotrys chartarum is a fungal species that can produce mycotoxins, specifically trichothecenes. Exposures in the indoor environment have reportedly induced neurogenic symptoms in adults and hemosiderosis in infants. However, little evidence has linked measured exposures to any fungal agent with any health outcome. We present here a study that focuses on quantitatively assessing the health risks from fungal toxin exposure. Male, 10 week old Charles River-Dawley rats were intratracheally instilled with approximately 9.6 million Stachybotrys chartarum spores in a saline suspension. The lungs were lavaged 0 h (i.e., immediately post-instillation), 6, 24 or 72 h after instillation. Biochemical indicators (albumin, myeloperoxidase, lactic dehydrogenase, hemoglobin) and leukocyte differentials in the bronchoalveolar lavage fluid and weight change were measured. We have demonstrated that a single, acute pulmonary exposure to a large quantity of Stachybotrys chartarum spores by intratracheal instillation causes severe injury detectable by bronchoalveolar lavage. The primary effect appears to be cytotoxicity and inflammation with hemorrhage. There is a measurable effect as early as 6 h after instillation, which may be attributable to mycotoxins in the fungal spores. The time course of responses supports early release of some toxins, with the most severe effects occurring between 6 and 24 h following exposure. By 72 h, recovery has begun, although macrophage concentrations remained elevated.


Assuntos
Líquido da Lavagem Broncoalveolar/citologia , Contagem de Leucócitos , Pulmão/microbiologia , Micotoxinas/toxicidade , Stachybotrys/patogenicidade , Albuminas/análise , Animais , Peso Corporal , Líquido da Lavagem Broncoalveolar/química , Hemoglobinas/análise , L-Lactato Desidrogenase/metabolismo , Macrófagos Alveolares , Masculino , Peroxidase/metabolismo , Ratos , Esporos Fúngicos , Fatores de Tempo , Traqueia
20.
Curr Microbiol ; 40(1): 10-6, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10568797

RESUMO

The increasing concern with bioaerosols in large office buildings prompted this prospective study of airborne fungal concentrations in a newly constructed building on the Gulf coast. We collected volumetric culture plate air samples on 14 occasions over the 18-month period immediately following building occupancy. On each sampling occasion, we collected duplicate samples from three sites on three floors of this six-story building, and an outdoor sample. Fungal concentrations indoors were consistently below those outdoors, and no sample clearly indicated fungal contamination in the building, although visible growth appeared in the ventilation system during the course of the study. We conclude that modern mechanically ventilated buildings prevent the intrusion of most of the outdoor fungal aerosol, and that even relatively extensive air sampling protocols may not sufficiently document the microbial status of buildings.


Assuntos
Microbiologia do Ar , Poluição do Ar em Ambientes Fechados , Fungos/isolamento & purificação , Ar Condicionado , Contagem de Colônia Microbiana , Fungos/classificação , Ventilação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...