1.
N Engl J Med ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38767244

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

3.
Heart Rhythm ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

4.
JACC Clin Electrophysiol ; 9(10): 2132-2145, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37676200

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an accepted alternative to transvenous (TV) ICD to provide defibrillation therapy to treat life-threatening ventricular tachyarrhythmias in high-risk patients. S-ICD outcomes by age group have not been reported. OBJECTIVES: In this study, the authors sought to report S-ICD outcomes in different age groups in a multicenter S-ICD post-approval study (PAS) involving the largest cohort of patients ever reported. METHODS: Patients were prospectively enrolled in the S-ICD PAS and stratified based on age: young, aged 15-34 years; adult, aged 35-69 years; and elderly, aged ≥70 years. Patient characteristics and clinical outcomes through 3 years of follow up after implantation were compared. RESULTS: The S-ICD PAS enrolled 1,637 patients. Elderly patients were more likely to receive an S-ICD as a replacement of a TV-ICD (15.1% elderly vs 12.3% adult vs 7.4% young). Secondary prevention indication decreased with age (32.7% young vs 22.2% adult vs 20.5% elderly). Mortality rate was significantly higher in the elderly group (24.0% elderly vs 13.0% adult vs 7.4% young; P < 0.0001), whereas the complication rate did not differ significantly (12.3% young vs 11.3% adult vs 8.1% elderly). Rates of appropriate shock (12.7% young vs 13.0% adult vs 13.8% elderly) and inappropriate shock (7.8% young vs 9.1% adult vs 8.8% elderly) rates did not differ between groups (P = 0.96 and P = 0.98, respectively). CONCLUSIONS: Implant complications and appropriate and inappropriate shock rates were similar among age groups. S-ICD for secondary prevention was more common in the young group. Replacing a TV-ICD for an S-ICD increases with age. (S-ICD System Post-Approval Study; NCT01736618).


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Adulto , Idoso , Humanos , Adolescente , Adulto Jovem , Desfibriladores Implantáveis/efeitos adversos , Seguimentos , Resultado do Tratamento , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiologia
5.
Circ Arrhythm Electrophysiol ; 16(8): 421-432, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37582163

RESUMO

BACKGROUND: This study assessed safety and feasibility of a novel extravascular implantable cardioverter defibrillator (ICD) lead when inserted anteriorly through a rib space and connected to various commercially available ICD pulse generators (PGs) placed in either a left mid-axillary or left pectoral pocket. Currently available or investigational, extravascular-ICDs include a subcutaneous or subxiphoid lead connected to customized extravascular-ICD PGs. METHODS: This novel extravascular-ICD (AtaCor Medical Inc, San Clemente, CA) employs a unique intercostal implant technique and is designed to function with commercial DF-4 ICD PGs. In this nonrandomized, single-center, acute study, 36 de novo or replacement ICD (transvenous ICD) patients enrolled to receive a concomitant extravascular-ICD lead inserted through an intercostal space along the left parasternal margin. extravascular-ICD leads were connected to DF-4 compatible ICD PGs positioned in either a left mid-axillary or pectoral pocket for acute sensing and defibrillation testing. Defibrillation testing started at 30 Joules (J) and stepped up or down in 5 to 10 joule increments depending on the success and limitations of the generator used. RESULTS: Successful acute defibrillation using ≤35 J was noted in 100% of left mid-axillary PG subjects (n=27, mean 16.3±8.6 J) and 83% of left pectoral PG subjects (n=6, mean 21.0±8.4 J). Furthermore, 24 of 27 (89%) of patients tested with a left, mid-axillary intermuscular PG had successful VF conversion with defibrillation energies at least 10 J below the maximum delivered output of the device. All evaluable episodes (n=93) were automatically sensed, detected, and shocked. No serious device-related intraoperative adverse events were observed. CONCLUSIONS: This first-in-human study documented the safe and reliable placement of a novel extravascular ICD lead with effective sensing and defibrillation of induced ventricular fibrillation using commercial DF-4 ICD PGs.


Assuntos
Desfibriladores Implantáveis , Humanos , Fibrilação Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
6.
Heart Rhythm O2 ; 4(7): 448-456, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520021

RESUMO

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years. Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.

7.
J Am Coll Cardiol ; 82(5): 383-397, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37495274

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to avoid complications related to transvenous implantable cardioverter-defibrillator (TV-ICD) leads. Device safety and efficacy were demonstrated previously with atypical clinical patients or limited follow-up. OBJECTIVES: The S-ICD PAS (Subcutaneous Implantable Cardioverter-Defibrillator System Post Approval Study) is a real-world, multicenter, registry of U.S. centers that was designed to assess long-term S-ICD safety and efficacy in a diverse group of patients and implantation centers. METHODS: Patients were enrolled in 86 U.S. centers with standard S-ICD indications and were observed for up to 5 years. Efficacy endpoints were first and final shock efficacy. Safety endpoints were complications directly related to the S-ICD system or implantation procedure. Endpoints were assessed using prespecified performance goals. RESULTS: A total of 1,643 patients were prospectively enrolled, with a median follow-up of 4.2 years. All prespecified safety and efficacy endpoint goals were met. Shock efficacy rates for discrete episodes of ventricular tachycardia or ventricular fibrillation were 98.4%, and they did not differ significantly across follow-up years (P = 0.68). S-ICD-related and electrode-related complication-free rates were 93.4% and 99.3%, respectively. Only 1.6% of patients had their devices replaced by a TV-ICD for a pacing need. Cumulative all-cause mortality was 21.7%. CONCLUSIONS: In the largest prospective study of the S-ICD to date, all study endpoints were met, despite a cohort with more comorbidities than in most previous trials. Complication rates were low and shock efficacy was high. These results demonstrate the 5-year S-ICD safety and efficacy for a large, diverse cohort of S-ICD recipients. (Subcutaneous Implantable Cardioverter-Defibrillator [S-ICD] System Post Approval Study [PAS]; NCT01736618).


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Resultado do Tratamento , Estudos Prospectivos , Arritmias Cardíacas/terapia , Taquicardia Ventricular/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle
8.
Heart Rhythm ; 19(12): 1993-2001, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35944889

RESUMO

BACKGROUND: Early subcutaneous implantable cardioverter-defibrillator (S-ICD) studies included atypical cohorts of patients who were younger with fewer comorbidities. Recent S-ICD studies included patient populations with more comorbidities. OBJECTIVES: The goals of this study were to determine the incidence and predictors of S-ICD-related infection over a 3-year follow-up period and to use these results to develop an infection risk score. METHODS: The S-ICD Post Approval Study is a US prospective registry of 1637 patients. Baseline demographic characteristics and outcomes with 3-year postimplantation follow-up were compared between patients with and without device-related infection. A risk score was derived from multivariable proportional hazards analysis of 22 variables. RESULTS: Infection was observed in 55 patients (3.3%), with 69% of infections occurring within 90 days and a vast majority (92.7%) within 1 year of implantation. Late infections more likely involved device erosion; no infections occurred after year 2. The annual mortality rate postinfection was 0.6%/y. No lead extraction complications or bacteremia related to infection were observed. An infection risk score was created with diabetes, age, prior transvenous ICD implant, and ejection fraction as predictors. Patients with a risk score of ≥3 had an 8.8 hazard ratio (95% confidence interval 2.8-16.3) of infection compared with a 0 risk score. CONCLUSION: Infection rates in the S-ICD Post Approval Study were similar to other S-ICD populations and not associated with systemic blood-borne infections. Late infection (>1 year) is uncommon and associated with system erosion. A high-risk infection cohort can be identified that may facilitate preventive measures.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Implantação de Prótese/métodos , Sistema de Registros , Estudos de Coortes
9.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36030464

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Resultado do Tratamento , Desfibriladores Implantáveis/efeitos adversos
10.
Heart Rhythm ; 19(5): 837-846, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35066181

RESUMO

BACKGROUND: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) and leadless pacemakers (LPs) are intended to diminish transvenous lead-related complications. However, S-ICDs do not deliver antibradycardia pacing or antitachycardia pacing, and currently, there is no commercially available coordinated leadless option for patients with defibrillator and (expected) pacing needs. OBJECTIVE: We evaluated the performance, safety, and potential replacement strategies of a novel modular cardiac rhythm management (mCRM) system, a wirelessly communicating antitachycardia pacing-enabled LP and S-ICD in a preclinical model. METHODS: LP implantation was attempted in 68 canine subjects, and in 38 an S-ICD was implanted as well. Animals were evaluated serially up to 18 months. At all evaluations, communication thresholds (CTs) between the devices, LP electrical parameters, and system-related complications were assessed. Different replacement strategies were tested. RESULTS: The LP was successfully implanted in 67 of 68 (98.5%) and the concomitant S-ICD in 38 of 38 (100%). mCRM communication was successful in 1022 of 1024 evaluations (99.8%). The mean CT was 2.2 ± 0.7 V at implantation and stable afterward (18 months: 1.8 ± 0.7 V). In multivariable analysis, larger LP-to-S-ICD angle and dorsal posture were associated with higher CTs. At implantation, the mean pacing capture threshold, impedance, and R-wave amplitude were 0.3 ± 0.1 V, 898.4 ± 198.9 Ω, and 26.4 ± 8.2 mV. The mean pacing capture threshold remained stable and impedance and R-wave amplitudes were within acceptable ranges throughout (0.7 ± 0.4 V, 619.1 ± 90.6 Ω, and 20.1 ± 8.4 mV at 18 months). Different replacement strategies seem feasible. CONCLUSION: This first mCRM system demonstrated excellent performance up to 18 months in a preclinical model.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Animais , Estimulação Cardíaca Artificial , Cães , Humanos , Resultado do Tratamento
11.
Circulation ; 145(5): 321-329, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779221

RESUMO

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 32(3): 792-801, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33492734

RESUMO

BACKGROUND: Traditionally, implantation of the subcutaneous implantable cardioverter defibrillator (S-ICD) requires incisions near the lateral chest wall, the xyphoid, and the superior sternal region (three-incision technique [3IT]). A two-incision technique (2IT) avoids the superior incision and has been shown to be a viable alternative in small studies with limited follow-up. OBJECTIVES: To report on the long-term safety and efficacy of the 2IT compared to the 3IT procedure in a large patient cohort. METHODS: Patients enrolled in the S-ICD post approval study (PAS) were stratified by procedural technique (2IT vs. 3IT). Baseline demographics, comorbidities and procedural outcomes were collected. Complications and S-ICD effectiveness in treating ventricular arrhythmias through an average 3-year follow-up period were compared. RESULTS: Of 1637 patients enrolled in the S-ICD PAS, 854 pts (52.2%) were implanted using the 2IT and 782 were implanted using the 3IT (47.8%). The 2IT became more prevalent over time, increasing from 40% to 69% of implants (Q1-Q4). Mean procedure time was shorter with 2IT (69.0 vs. 86.3 min, p < .0001). No other differences in outcomes were observed between the two groups, including rates of infection, electrode migration, inappropriate shocks and first shock efficacy for treating ventricular arrhythmias. CONCLUSION: In this large cohort of patients implanted with an S-ICD and followed for 3 years the 2IT was as safe and effective as the 3IT while significantly reducing procedure time.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Estudos de Coortes , Comorbidade , Humanos , Implantação de Prótese/efeitos adversos , Resultado do Tratamento
13.
Circulation ; 143(1): 7-17, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33073614

RESUMO

BACKGROUND: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. METHODS: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. RESULTS: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. CONCLUSIONS: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02433379.


Assuntos
Arritmias Cardíacas/prevenção & controle , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/normas , Prevenção Primária/métodos , Volume Sistólico/fisiologia , Adulto , Idoso , Arritmias Cardíacas/fisiopatologia , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Desfibriladores/normas , Desfibriladores/tendências , Desfibriladores Implantáveis/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
14.
JACC Clin Electrophysiol ; 6(12): 1537-1550, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33213814

RESUMO

OBJECTIVES: This study evaluated spontaneous arrhythmias and clinical outcomes in the S-ICD System PAS (Subcutaneous Implantable Cardioverter-Defibrillator Post Approval Study) cohort. BACKGROUND: The U.S. S-ICD PAS trial patient population more closely resembles transvenous ICD cohorts than earlier studies, which included many patients with little structural heart disease and few comorbidities. Early outcomes and low peri-operative complication rates were demonstrated in the S-ICD PAS cohort, but there are no data detailing spontaneous arrhythmias and clinical outcomes. METHODS: The S-ICD PAS prospective registry included 1,637 de novo patients from 86 U.S. centers. Descriptive statistics, Kaplan-Meier time to event, and multivariate logistic regression were performed using data out to 365 days. RESULTS: Patients (68.5% men; mean ejection fraction of 32.0%; 42.9% ischemic; 13.4% on dialysis) underwent implantation for primary (76.6%) or secondary prevention indication. The complication-free rate was 92.5%. The appropriate shock (AS) rate was 5.3%. A total of 395 ventricular tachycardia (VT) or fibrillation (VF) episodes were appropriately sensed, with 131 (33.2%) self-terminating. First and final shock efficacy (up to 5 shocks) for the 127 discrete AS episodes were 91.3% and 100.0%, respectively. Discrete AS episodes included 67 monomorphic VT (MVT) and 60 polymorphic VT (PVT)/VF, with first shock efficacy of 95.2% and 86.7%, respectively. There were 19 storm events in 18 subjects, with 84.2% conversion success. Storm episodes were more likely PVT/VF (98 of 137). CONCLUSIONS: In the first year after implantation, a predominantly primary prevention population with low ejection fraction demonstrated a high complication-free rate and spontaneous event shock efficacy for MVT and PVT/VF arrhythmias at rapid ventricular rates. (Subcutaneous Implantable Cardioverter-Defibrillator System Post Approval Study [S-ICD PAS; NCT01736618).


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas/epidemiologia , Estudos de Coortes , Desfibriladores Implantáveis/efeitos adversos , Feminino , Humanos , Masculino , Prevenção Primária , Taquicardia Ventricular/epidemiologia , Resultado do Tratamento
15.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-32757521

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Idoso , Cardiomiopatias/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Feminino , Seguimentos , Cardiopatias/terapia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
16.
Heart Rhythm ; 17(9): 1566-1574, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32376304

RESUMO

BACKGROUND: Patients with chronic renal disease on hemodialysis (HD) have limited vascular access and are at high risk of bacteremia. The subcutaneous implantable cardioverter-defibrillator (S-ICD) avoids vascular access, so it may be advantageous in this patient population. OBJECTIVE: The purpose of this study was to report outcomes of patients with end-stage renal disease enrolled in the multicenter S-ICD post-approval study (PAS). METHODS: S-ICD PAS patients were stratified on the basis of the presence (group 1) or absence (group 2) of HD at the time of implantation. Baseline demographic and clinical characteristics were collected. Perioperative and intermediate-term outcomes 365 days postimplantation were compared between the 2 groups. RESULTS: There were 220 patients on HD (13.4%) at the time of implantation out of 1637 patients enrolled in the S-ICD PAS. Patients on HD (group 1) were older (57.4 ± 13.2 years vs 52.5 ± 15.2 years; P < .0001), more likely to be of African descent (48.6% vs 25.1%; P < .0001), and had lower ejection fraction (28.6% ± 11.3% vs 32.6% ± 14.9%; P < .0001) as compared with patients not on HD (group 2). Group 1 had more comorbidities and mortality was higher (17.4% vs 3.7%) than did group 2. The rate of complications calculated using the Kaplan-Meier estimate did not differ between the 2 groups (overall P = .9169), with a 1-year rate of 7.9% and 7.7% for groups 1 and 2, respectively. The rate of appropriate shocks was significantly higher in group 1 (Kaplan-Meier analysis, P = .0003), as was inappropriate shocks (P = .0137). CONCLUSION: S-ICD is associated with similar adverse event rates but a higher risk of inappropriate and appropriate therapy in dialysis patients than in nondialysis patients.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Falência Renal Crônica/terapia , Diálise Renal , Medição de Risco/métodos , Arritmias Cardíacas/epidemiologia , Comorbidade , Feminino , Seguimentos , Humanos , Falência Renal Crônica/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
17.
Circ Arrhythm Electrophysiol ; 12(7): e007182, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31266354

RESUMO

BACKGROUND: A completely extracardiac pacing system provides the potential for clinical advantages over existing device alternatives that require intravascular, endocardial, or epicardial contact. Preliminary studies evaluating the feasibility of cardiac pacing with a lead in the anterior mediastinum, outside the pericardium and circulatory system have been completed. These studies examined (1) the anatomic access route, (2) the usability of a delivery tool to facilitate lead placement, and (3) the pacing performance of the extracardiac lead. METHODS: Feasibility evaluations included (1) a retrospective computed tomography analysis to characterize anatomic variations related to lead access, (2) accessing the anterior mediastinum in cadavers and human subjects using a custom delivery tool, and (3) acute clinical pacing performance. RESULTS: Major findings: (1) A total of 166 (95%) out of 174 patients had a viable lead access path through the fourth, fifth, or sixth intercostal space. (2) Access to the targeted implant location using a delivery tool was successful in all 5 cadavers and 3 humans without use of fluoroscopy and with an average lead delivery time of 121±52 s. No damage to the lung, pericardium, heart, or internal thoracic vessels occurred. (3) Pacing performance was tested in 6 human subjects showing a threshold voltage of 4.7 V (2.7-6.7), threshold pulse width of 1.8 ms (1.0-2.5), and an impedance of 1205 Ω (894-1786). R-wave amplitudes measured 9.6 mV (5.6-12.0). CONCLUSIONS: Results support the feasibility for this completely extracardiac pacing method in a heterogeneous patient population, using a minimally invasive, parasternal, delivery approach and with adequate sensing and thresholds suited for temporary pacing.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Mediastino , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Cadáver , Dissecação , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Mediastino/diagnóstico por imagem , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
18.
Am Heart J ; 214: 167-174, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31220775

RESUMO

In transvenous implantable cardioverter-defibrillator (TV-ICD) implants, routine defibrillation testing (DFT) does not improve shock efficacy or reduce arrhythmic death but patients are exposed to the risk of complications related to DFT. The conversion rate of DFT in subcutaneous ICD (S-ICD) is high and first shock efficacy is similar to TV-ICD efficacy rates. STUDY DESIGN: The PRAETORIAN-DFT trial is an investigator-initiated, randomized, controlled, multicenter, prospective two-arm trial designed to demonstrate non-inferiority of omitting DFT in patients undergoing S-ICD implantation in which the S-ICD system components are optimally positioned. Positioning of the S-ICD will be assessed with the PRAETORIAN score. The PRAETORIAN score is developed to systematically evaluate implant position of the S-ICD system components which determine the defibrillation threshold on post-operative chest X-ray. A total of 965 patients, scheduled to undergo a de novo S-ICD implantation without contra-indications for either DFT strategy, will be randomized to either standard of care S-ICD implantation with DFT, or S-ICD implantation without DFT but with evaluation of the implant position using the PRAETORIAN score. The study is powered to claim non-inferiority of S-ICD implantation without DFT in de novo S-ICD patients in respect to the primary endpoint of first shock efficacy in spontaneous arrhythmia episodes. Patients with a high PRAETORIAN score (≥90) in the interventional arm of this study will undergo DFT according to the same DFT protocol as in the control arm. CONCLUSION: The PRAETORIAN-DFT trial is a randomized trial that aims to gain scientific evidence to safely omit a routine DFT after S-ICD implantation in patients with correct device positioning.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Segurança de Equipamentos , Morte Súbita Cardíaca/prevenção & controle , Humanos , Monitorização Fisiológica , Seleção de Pacientes , Estudos Prospectivos
19.
Heart Rhythm ; 16(11): 1636-1644, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31082539

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has shown favorable outcomes in large registries with broad inclusion criteria. The cohorts reported had less heart disease and fewer comorbidities than standard ICD populations. OBJECTIVE: The purpose of this study is to characterize acute performance for primary prevention patients with a left ventricular ejection fraction (LVEF) ≤35% (primary prevention ≤35%). METHODS: Primary prevention ≤35% patients with no prior documented sustained ventricular tachycardia (VT), pacing indication, end-stage heart failure, or advanced renal failure were prospectively enrolled. Analyses included descriptive statistics, Kaplan-Meier time to event, and multivariable linear and logistic regression. RESULTS: In 1112 of 1116 patients, an S-ICD was successfully implanted (99.6%). Predictors for longer procedure time included 3-incision technique, higher body mass index (BMI), performing defibrillation testing (DFT), imaging, younger age, black race, and European vs North American centers. Patients undergoing DFT (82%) were successfully converted (99.2%; 93.5% converting at ≤65 J). Higher BMI was predictive of failing DFT at ≤65 J. The rate of 30-day freedom from complications was 95.8%. Most complications involved postoperative healing (45%) or interventions after DFT or impedance check (19%). CONCLUSION: The procedural outcome data of UNTOUCHED reinforce that S-ICD therapy has low perioperative complication rates and high conversion efficacy of induced ventricular fibrillation, even in a higher-risk cohort with low LVEF and more comorbidities than previous S-ICD studies. Higher BMI warrants more careful attention to implant technique.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias , Estudos Prospectivos , Volume Sistólico
20.
Circ Arrhythm Electrophysiol ; 12(4): e006665, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30917689

RESUMO

BACKGROUND: The ability to predict defibrillation efficacy at the time of subcutaneous implantable cardioverter-defibrillator implantation without the need to induce ventricular fibrillation might eliminate the need for defibrillation testing. The purpose of this study was to determine the association of high-voltage impedance and system implant position on ventricular fibrillation conversion success with a submaximal 65-J shock. METHODS: In the subcutaneous implantable cardioverter-defibrillator IDE study (Investigational Device Exemption), a successful conversion test required 2 consecutive ventricular fibrillation conversions at 65 J in either shock vector. Chest radiographs were obtained after implantation. Patients with imaging and impedance data were included. Suboptimal device position was defined as an inferior electrode or pulse generator or electrode coil depth >3 mm anterior to the sternum. Absence of suboptimal positional parameters was defined as appropriate position. Conversion success rate was calculated among all 65-J tests. RESULTS: Of 314 patients who underwent subcutaneous implantable cardioverter-defibrillator implantation, 282 patients were included in this analysis. There were 637 inductions to test defibrillation at 65 J. Sixty-two conversion failures (9.7%) occurred in 42 (14.9%) patients. Lower body mass index and lower shock impedance were associated with higher conversion success rate, whereas white race was associated with lower conversion success rate. Suboptimal position was more common in obese patients. Inferior electrode and greater distance between the lead and sternum were associated with a higher impedance. When appropriate system position was achieved, conversion failure was not associated with high body mass index. CONCLUSIONS: Subcutaneous implantable cardioverter-defibrillator shock efficacy is associated with system position and high-voltage system impedance. A high impedance is associated with inferiorly placed pulse generator and electrode system, inadequate coil depth, and a lower rate of defibrillator success. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01064076.


Assuntos
Desfibriladores Implantáveis , Fibrilação Ventricular/prevenção & controle , Adulto , Idoso , Índice de Massa Corporal , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Torácica , Fibrilação Ventricular/fisiopatologia