Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 306
Filtrar
2.
Heart Rhythm ; 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38246567

RESUMO

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.

3.
J Consum Policy (Dordr) ; 46(2): 137-153, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36815974

RESUMO

This online intervention study examined whether system- and action-related information alone, together with goal setting, or together with goal setting and feedback helps people change their video streaming activities in a pro-environmental way. The participants (N = 92) documented their video streaming activities for one week prior to the intervention (week 1), three weeks after the onset of the intervention (weeks 2-4), and in a follow-up period two weeks later (week 7). A reduction of greenhouse gas emissions associated with video streaming was observed over the course of the intervention, together with reduced streaming durations and lowered resolution settings across all groups. There were no differences between the groups. It appears that as regards video streaming, information combined with self-monitoring has considerable potential to change individual behaviour and its associated ecological impact.

6.
Circ Arrhythm Electrophysiol ; 15(6): e010975, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35617267

RESUMO

BACKGROUND: Following left atrial appendage (LAA) electrical isolation, the decision on whether to continue oral anticoagulation after successful atrial fibrillation ablation is based on the study of its mechanical function on transesophageal echocardiography (TEE). In this cohort, LAA contraction is absent and the incorrect interpretation of emptying flow velocities can lead to unwanted clinical sequelae. METHODS: One hundred and sixty consecutive TEE exams performed to evaluate the LAA mechanical function following its electrical isolation were reviewed by an experienced operator blinded to the original diagnosis of LAA dysfunction. The rate of diagnostic discrepancy in the assessment LAA dysfunction and its clinical implications were evaluated. RESULTS: Diagnostic discrepancy with misclassification of the LAA mechanical function occurred 36% (58/160) of TEE exams. In most cases (57/58), such discrepancy was observed in the setting of an incorrect original diagnosis of a normal LAA mechanical function despite absent/reduced or inconsistent LAA contraction. This main source of this wrong diagnosis was the wrong interpretation of passive LAA flows (34/57; 60%), followed by failure to identify dissociated firing (15/57; 26%). In rare cases (8/57; 14%), velocities of surrounding structures were interpreted as LAA flow due to misplacement of the pulsed-wave Doppler sample volume. Following LAA isolation, the proportion of patients who experienced a cerebrovascular event while off oral anticoagulation due to the misclassification of their LAA mechanical function was 70% (7/10 [95% CI, 40%-89%]). CONCLUSIONS: Underdiagnosis of LAA mechanical dysfunction is common in TEEs performed following LAA electrical isolation, and it is associated with an increased risk of cerebrovascular events owing to oral anticoagulation discontinuation despite absent/reduced LAA contraction. Careful review of the TEE exam by an operator with specific expertise in LAA imaging and familiar with the functional implications of LAA isolation is necessary before interrupting oral anticoagulation in this cohort.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Anticoagulantes/uso terapêutico , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ecocardiografia Transesofagiana/métodos , Humanos
7.
Card Electrophysiol Clin ; 14(1): 1-9, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35221076

RESUMO

COVID-19 mainly affects the respiratory system but has been correlated with cardiovascular manifestations such as myocarditis, heart failure, acute coronary syndromes, and arrhythmias. Cardiac arrhythmias are the second most frequent complication affecting about 30% of patients. Several mechanisms may lead to an increased risk of cardiac arrhythmias during COVID-19 infection, ranging from direct myocardial damage to extracardiac involvement. The aim of this review is to describe the role of COVID-19 in the pathogenesis of cardiac arrhythmias and provide a comprehensive guidance for their monitoring and management.


Assuntos
Fibrilação Atrial , Flutter Atrial , COVID-19 , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/cirurgia , COVID-19/complicações , Ablação por Cateter/efeitos adversos , Humanos , Prevalência , SARS-CoV-2
8.
Heart Rhythm ; 18(8S): S318, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34736718

RESUMO

This article has been retracted: please see Elsevier Policy on Article Withdrawal (https://www.elsevier.com/about/our-business/policies/article-withdrawal). This article has been retracted at the request of the authors. The authors inadvertently specified some ablation settings in the methods section that should not have been reported because they can be potentially linked to a specific pulsed field ablation technology that is currently under investigation for FDA approval. The Authors apologize for the inconvenience caused by this oversight, http://dx.doi.org/.

9.
Heart Rhythm ; 18(8S): S5-S6, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34736719

RESUMO

This article has been retracted: please see Elsevier Policy on Article Withdrawal (https://www.elsevier.com/about/our-business/policies/article-withdrawal). This article has been retracted at the request of the authors. The authors inadvertently specified some ablation settings in the methods section that should not have been reported because they can be potentially linked to a specific pulsed field ablation technology that is currently under investigation for FDA approval. The Authors apologize for the inconvenience caused by this oversight, http://dx.doi.org/.

10.
JACC Cardiovasc Interv ; 14(21): 2353-2364, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34656496

RESUMO

OBJECTIVES: This study evaluated the long-term efficacy of a standard antithrombotic strategy versus half-dose direct oral anticoagulation (DOAC) after Watchman implantation. BACKGROUND: No consensus currently exists on the selection of the most effective antithrombotic strategy to prevent device-related thrombosis (DRT) in patients undergoing endocardial left atrial appendage closure. METHODS: After successful left atrial appendage closure, consecutive patients were prescribed a standard antithrombotic strategy (SAT) or long-term half-dose DOAC (hdDOAC). The primary composite endpoint was DRT and thromboembolic (TE) and bleeding events. RESULTS: Overall, 555 patients (mean age 75 ± 8 years, 63% male; median CHA2DS2-VASc [congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score 4 [interquartile range (IQR): 3-6]; median HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] score 3 [IQR: 2-4]) were included. Patients were categorized into 2 groups (SAT: n = 357 vs hdDOAC: n = 198). Baseline clinical characteristics were similar between groups. The median follow-up duration was 13 months (IQR: 12-15 months). DRT occurred in 12 (2.1%) patients, all in the SAT group (3.4% vs 0.0%; log-rank P = 0.009). The risk of nonprocedural major bleeding was significantly more favorable in the hdDOAC group (0.5% vs. 3.9%; log-rank P = 0.018). The rate of the primary composite endpoint of DRT and TE and major bleeding events was 9.5% in SAT patients and 1.0% in hdDOAC patients (HR: 9.8; 95% CI: 2.3-40.7; P = 0.002). CONCLUSIONS: After successful Watchman implantation, long-term half-dose DOAC significantly reduced the risk of the composite endpoint of DRT and TE and major bleeding events compared with a standard, antiplatelet-based, antithrombotic therapy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Feminino , Fibrinolíticos/efeitos adversos , Humanos , Masculino , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 32(11): 2915-2922, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34554634

RESUMO

BACKGROUND: Intracardiac electrogram data remain one of the primary diagnostic inputs guiding complex ablation procedures. However, the technology to collect, process, and display intracardiac signals has known shortcomings and has not advanced in several decades. OBJECTIVE: The purpose of this study was to evaluate a new signal processing platform, the PURE EP™ system (PURE), in a multi-center, prospective study. METHODS: Intracardiac signal data of clinical interest were collected from 51 patients undergoing ablation procedures with PURE, the signal recording system, and the 3D mapping system at the same time stamps. The samples were randomized and subjected to blinded, controlled evaluation by three independent electrophysiologists to determine the overall quality and clinical utility of PURE signals when compared to conventional sources. Each reviewer assessed the same (92) signal sample sets and responded to (235) questions using a 10-point rating scale. If two or more reviewers rated the PURE signal higher than the control, it was deemed superior. RESULTS: A total of 93% of question responses showed consensus amongst the blinded reviewers. Based on the ratings for each pair of signals, a cumulative total of 164 PURE signals out of 218 (75.2%) were statistically rated as Superior for this data set (p < .001). Only 14 PURE signals out of 218 were rated as Inferior (6.4%). CONCLUSION: The PURE intracardiac signals were statistically rated as superior when compared to conventional systems.


Assuntos
Eletrofisiologia Cardíaca , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Coração , Humanos , Estudos Prospectivos , Processamento de Sinais Assistido por Computador
13.
J Cardiovasc Electrophysiol ; 32(10): 2781-2784, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34411376

RESUMO

INTRODUCTION: Watchman FLX has been recently approved for left atrial appendage occlusion (LAAO) in the US. Intracardiac echocardiography (ICE) - which is already commonly used to guide trans-septal access - can serve as an alternative to TEE, simplifying the procedure and reducing associated costs. Herein, we report our experience with ICE-guided LAAO with Watchman FLX. METHODS AND RESULTS: This cohort study included the first 190 consecutive patients who underwent LAAO with Watchman FLX in our center. LAAO was successful in all patients without significant peri-procedural, device-related complications in either group. Compared to TEE, we observed a significant reduction in procedural times when using ICE. In addition, there was a potentially clinically relevant reduction in fluoroscopy dose, mainly secondary to fewer cine acquisition runs. At follow-up, no cases of device embolism were noted, whereas the rate of device-related thrombosis and peri-device leaks were comparable between groups. CONCLUSION: ICE-guided LAAO with Watchman FLX is safe and feasible, with a significant reduction in procedural time and potential reduction in fluoroscopy dose when compared to TEE.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Estudos de Coortes , Ecocardiografia Transesofagiana , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção
14.
JACC Clin Electrophysiol ; 7(12): 1573-1584, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34330671

RESUMO

OBJECTIVES: The aim of this study was to evaluate the efficacy of radiofrequency (RF) energy applications targeting the atrial side of a significant residual leak in patients with acute and chronic evidence of incomplete percutaneous left atrial appendage (LAA) occlusion. BACKGROUND: RF applications have been proved to prevent recanalization of intracranial aneurysms after coil embolization, thereby favoring complete sealing. From a mechanistic standpoint, in vitro and in vivo experiments have demonstrated that RF promotes collagen deposition and tissue retraction. METHODS: Forty-three patients (mean age 75 ± 7 years mean CHA2DS2-VASc score 4.6 ± 1.4, mean HAS-BLED score 4.0 ± 1.1) with residual leaks ≥4 mm after Watchman implantation were enrolled. Procedural success was defined as complete LAA occlusion or presence of a mild or minimal (1- to 2-mm) peridevice leak on follow-up transesophageal echocardiography (TEE), which was performed approximately 45 days after the procedure. RESULTS: RF-based leak closure was performed acutely after Watchman implantation in 19 patients (44.2%) or scheduled after evidence of significant leaks on follow-up TEE in 24 others (55.8%). The median leak size was 5 mm (range: 4-7 mm). On average, 18 ± 7 RF applications per patient (mean maximum contact force 16 ± 3 g, mean power 44 ± 2 W, mean RF time 5.1 ± 2.5 minutes) were performed targeting the atrial edge of the leak. Post-RF median leak size was 0 mm (range: 0-1 mm). A very low rate (2.3% [n = 1]) of major periprocedural complications was observed. Follow-up TEE revealed complete LAA sealing in 23 patients (53.5%) and negligible residual leaks in 15 (34.9%). CONCLUSIONS: RF applications targeting the atrial edge of a significant peri-Watchman leak may promote LAA sealing via tissue remodeling, without increasing complications. (RF Applications for Residual LAA Leaks [REACT]; NCT04726943).


Assuntos
Apêndice Atrial , Fibrilação Atrial , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Humanos , Estudos Prospectivos , Resultado do Tratamento
15.
JACC Clin Electrophysiol ; 7(12): 1533-1543, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34217665

RESUMO

OBJECTIVES: This study sought to report the incidence of device-related thrombosis (DRT) and thromboembolic (TE) events when an alternative to clopidogrel is prescribed in loss-of-function (LOF) allele carriers of the cytochrome P450 2C19 (CYP2C19) gene. BACKGROUND: LOF polymorphisms of the CYP2C19 gene are associated with reduced hepatic bioactivation of clopidogrel. METHODS: A total of 1,002 Watchman patients were included. Six hundred forty-five patients underwent CYP2C19 genetic testing; among patients with clopidogrel resistance, clopidogrel was replaced by either prasugrel (pilot cohort) or half dose direct oral anticoagulant ([DOAC]/Group 1), both in combination with aspirin. We compared the incidence of DRT/TE events among genotyped patients and a control group which received standard dual antiplatelet therapy (DAPT) (Group 2; n = 357). All reported events occurred during a timeframe between 45- and 180-day follow-up transesophageal echocardiograms, when the 2 different antithrombotic strategies (genotype-guided vs standard DAPT) were adopted. RESULTS: In the pilot cohort (n = 244), bleeding events occurred in 10.2% of patients who received aspirin plus prasugrel, leading to early discontinuation of the prasugrel-based protocol. DOAC Group 1 patients (n = 401), 25.7% were reduced metabolizers, and clopidogrel was replaced by half dose direct oral anticoagulant. DRT was documented in 1 (0.2%) patient of Group 1 and 7 (1.96%) patients of Group 2 (log-rank P = 0.021). The composite endpoint of DRT/TE events was significantly lower among patients receiving a genotype-guided antithrombotic strategy (0.75% vs 3.10%; log-rank P = 0.017). CONCLUSIONS: In Watchman patients, a genotype-based antithrombotic strategy with aspirin plus half dose DOAC in reduced clopidogrel metabolizers was superior to standard DAPT with respect to DRT/TE events.


Assuntos
Fibrinolíticos , Trombose , Clopidogrel/efeitos adversos , Genótipo , Humanos , Incidência , Trombose/tratamento farmacológico , Trombose/epidemiologia , Trombose/genética
17.
J Am Heart Assoc ; 10(11): e020563, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33998277

RESUMO

Background We evaluated long-term outcome of isolation of pulmonary veins, left atrial posterior wall, and superior vena cava, including time to recurrence and prevalent triggering foci at repeat ablation in patients with paroxysmal atrial fibrillation with or without cardiovascular comorbidities. Methods and Results A total of 1633 consecutive patients with paroxysmal atrial fibrillation that were arrhythmia-free for 2 years following the index ablation were classified into: group 1 (without comorbidities); n=692 and group 2 (with comorbidities); n=941. We excluded patients with documented ablation of areas other than pulmonary veins, the left atrial posterior wall, and the superior vena cava at the index procedure. At 10 years after an average of 1.2 procedures, 215 (31%) and 480 (51%) patients had recurrence with median time to recurrence being 7.4 (interquartile interval [IQI] 4.3-8.5) and 5.6 (IQI 3.8-8.3) years in group 1 and 2, respectively. A total of 201 (93.5%) and 456 (95%) patients from group 1 and 2 underwent redo ablation; 147/201 and 414/456 received left atrial appendage and coronary sinus isolation and 54/201 and 42/456 had left atrial lines and flutter ablation. At 2 years after the redo, 134 (91.1%) and 391 (94.4%) patients from group 1 and 2 receiving left atrial appendage/coronary sinus isolation remained arrhythmia-free whereas sinus rhythm was maintained in 4 (7.4%) and 3 (7.1%) patients in respective groups undergoing empirical lines and flutter ablation (P<0.001). Conclusions Very late recurrence of atrial fibrillation after successful isolation of pulmonary veins, regardless of the comorbidity profile, was majorly driven by non-pulmonary vein triggers and ablation of these foci resulted in high success rate. However, presence of comorbidities was associated with significantly earlier recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Átrios do Coração/cirurgia , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares/cirurgia , Taquicardia Paroxística/cirurgia , Veia Cava Superior/cirurgia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Taquicardia Paroxística/epidemiologia , Taquicardia Paroxística/fisiopatologia , Fatores de Tempo , Estados Unidos/epidemiologia
18.
Card Electrophysiol Clin ; 13(2): 419-426, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33990280

RESUMO

With real-time three-dimensional ultrasound, live volumetric images with adequate spatial and temporal resolution are obtained to accurately display structures with complex anatomy and guide interventional procedures. In this review, we will provide an overview of current ultrasound technologies that allow for real-time three-dimensional imaging, with a focus on their application for three-dimensional intracardiac echocardiography.


Assuntos
Ecocardiografia Tridimensional , Desenho de Equipamento , Coração/diagnóstico por imagem , Humanos
19.
AJNR Am J Neuroradiol ; 42(5): 904-909, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33707283

RESUMO

BACKGROUND AND PURPOSE: EmboTrap II is a novel stent retriever with a dual-layer design and distal mesh designed for acute ischemic stroke emergent large-vessel occlusions. We present the first postmarket prospective multicenter experience with the EmboTrap II stent retriever. MATERIALS AND METHODS: A prospective registry of patients treated with EmboTrap II at 7 centers following FDA approval was maintained with baseline patient characteristics, treatment details, and clinical/radiographic follow-up. RESULTS: Seventy patients were treated with EmboTrap II (mean age, 69.9 years; 48.6% women). Intravenous thrombolysis was given in 34.3%, and emergent large-vessel occlusions were located in the ICA (n = 18), M1 (n = 38), M2 or M3 (n = 13), and basilar artery (n = 1). The 5 × 33 mm device was used in 88% of cases. TICI ≥ 2b recanalization was achieved in 95.7% (82.3% in EmboTrap II-only cases), and first-pass efficacy was achieved in 35.7%. The NIHSS score improved from a preoperative average of 16.3 to 12.1 postprocedure and to 10.5 at discharge. An average of 2.5 [SD, 1.8] passes was recorded per treatment, including non-EmboTrap attempts. Definitive treatment was performed with an alternative device (aspiration or stent retriever) in 9 cases (12.9%). Some hemorrhagic conversion was noted in 22.9% of cases, of which 4.3% were symptomatic. There were no device-related complications. CONCLUSIONS: Initial postmarket results with the EmboTrap II stent retriever are favorable and comparable with those of other commercially available stent retrievers. Compared with EmboTrap II, the first-generation EmboTrap may have a higher first-pass efficacy; however, data are limited by retrospective case analysis, incomplete clinical follow-up, and small sample size, necessitating future trials.


Assuntos
AVC Isquêmico/cirurgia , Stents , Trombectomia/instrumentação , Resultado do Tratamento , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vigilância de Produtos Comercializados , Sistema de Registros , Estudos Retrospectivos , Trombectomia/métodos
20.
Medicina (Kaunas) ; 57(3)2021 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-33652714

RESUMO

A recent surveillance analysis indicates that cardiac arrest/death occurs in ≈1:50,000 professional or semi-professional athletes, and the most common cause is attributable to life-threatening ventricular arrhythmias (VAs). It is critically important to diagnose any inherited/acquired cardiac disease, including coronary artery disease, since it frequently represents the arrhythmogenic substrate in a substantial part of the athletes presenting with major VAs. New insights indicate that athletes develop a specific electro-anatomical remodeling, with peculiar anatomic distribution and VAs patterns. However, because of the scarcity of clinical data concerning the natural history of VAs in sports performers, there are no dedicated recommendations for VA ablation. The treatment remains at the mercy of several individual factors, including the type of VA, the athlete's age, and the operator's expertise. With the present review, we aimed to illustrate the prevalence, electrocardiographic (ECG) features, and imaging correlations of the most common VAs in athletes, focusing on etiology, outcomes, and sports eligibility after catheter ablation.


Assuntos
Ablação por Cateter , Esportes , Arritmias Cardíacas , Atletas , Eletrocardiografia , Coração , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...