Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Environ Manage ; 213: 353-362, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29502020

RESUMO

Scholars from many different intellectual disciplines have attempted to measure, estimate, or quantify resilience. However, there is growing concern that lack of clarity on the operationalization of the concept will limit its application. In this paper, we discuss the theory, research development and quantitative approaches in ecological and community resilience. Upon noting the lack of methods that quantify the complexities of the linked human and natural aspects of community resilience, we identify several promising approaches within the ecological resilience tradition that may be useful in filling these gaps. Further, we discuss the challenges for consolidating these approaches into a more integrated perspective for managing social-ecological systems.


Assuntos
Ecologia , Ecossistema , Humanos
2.
Appl Radiat Isot ; 126: 232-236, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28302444

RESUMO

As the world faces a challenging future in maintaining the commercial availability of radioactive isotopes for medical use, new methods of medical isotope production are being pursued. Many of these are small in size and could effectively operate continuously. With the potential for much shorter retention times, a new suite of isotopes may soon be found in the environment. The authors estimate that many more aerosols containing low-level isotopes of gas/volatile origin could be detectable at short range and times, and a few at longer ranges and times as compared to those released in more common nuclear reactor operations.

3.
Appl Radiat Isot ; 126: 240-242, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28041679

RESUMO

PNNL has developed two low-background gamma-ray spectrometers in a new shallow underground laboratory, thereby significantly improving its ability to detect low levels of gamma-ray emitting fission or activation products in airborne particulate in samples from the IMS (International Monitoring System). The combination of cosmic veto panels, dry nitrogen gas to reduce radon and low background shielding results in a reduction of the background count rate by about a factor of 100 compared to detectors operating above ground at our laboratory.

4.
J Environ Radioact ; 146: 1-5, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25875083

RESUMO

The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a network of certified laboratories which must meet certain sensitivity requirements for CTBT relevant radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a high-efficiency, dual-detector gamma spectroscopy system has been developed to improve the sensitivity of measurements for treaty compliance, greatly reducing the time required for each sample. Utilising list-mode acquisition, each sample can be counted once, and processed multiple times to further improve sensitivity. For the 8 key radionuclides considered, Minimum Detectable Activities (MDA's) were improved by up to 37% in standard mode (when compared to a typical CTBT detector system), with the acquisition time required to achieve the CTBT sensitivity requirements reduced from 6 days to only 3. When utilising the system in coincidence mode, the MDA for (60) Co in a high-activity source was improved by a factor of 34 when compared to a standard CTBT detector, and a factor of 17 when compared to the dual-detector system operating in standard mode. These MDA improvements will allow the accurate and timely quantification of radionuclides that decay via both singular and cascade γ emission, greatly enhancing the effectiveness of CTBT laboratories.


Assuntos
Poluentes Radioativos do Ar/análise , Monitoramento de Radiação/instrumentação , Radioisótopos/análise , Germânio , Cooperação Internacional , Espectrometria gama/instrumentação
5.
J Environ Radioact ; 134: 1-5, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24631843

RESUMO

Monte-Carlo simulations have been utilised to determine the optimum material and thickness for a γ spectrometer to be used for the assay of radionuclides that emit radiation in the 50-300 keV energy range. Both HPGe and LaBr3(Ce) materials were initially considered for use, however the additional background radiation and lack of resolution in the latter drove the selection of HPGe for further optimisation. Multiple thicknesses were considered for the HPGe detector, with the aim of improving the sensitivity of the system by maximising the efficiency for low energy emissions, and reducing the probability of interaction with (and therefore the continuum from) higher energy photons. The minimum amount of material needed to achieve this was found to be 15 mm for a source that is dominated by high energy (>2.614 MeV) photons, and 20-30 mm for a typical reference source (with photons of energy 59.54 keV-2.614 MeV).


Assuntos
Método de Monte Carlo , Radioisótopos/química , Espectrometria gama/métodos
6.
J Environ Radioact ; 102(4): 326-30, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21306802

RESUMO

A novel technique has been developed for determining the (212)Pb activity of fresh waters. This is of interest to environmental monitoring programmes that utilise gross α-activity methods to screen for anthropogenic radionuclides. The contribution from (212)Pb varies, and is difficult to experimentally measure due to its relatively short half-life (t(½) = 10.6 h) and low environmental activity (<0.1 Bq l(-1)). The use of a three-stage technique that encompasses a unique form of pre-concentration, separation and analysis by liquid scintillation counting allows a lower detection limit of 0.006 Bq l(-1) with a chemical yield of 92.5 ± 5.6%. The measurement can be obtained within 7 h of sample collection, and is calculated using the radioactive decay of (212)Bi. Other naturally occurring radionuclides may also be extracted using the pre-concentration stage of the technique, with efficiencies above 90% at a range of pH values.


Assuntos
Radiação de Fundo , Técnicas de Química Analítica/métodos , Água Doce/química , Radioisótopos de Chumbo/análise , Monitoramento de Radiação/métodos , Contagem de Cintilação/métodos , Bismuto/química , Compostos de Manganês , Óxidos , Monitoramento de Radiação/estatística & dados numéricos
7.
J Radiol Prot ; 30(3): 525-33, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20826890

RESUMO

Sudden increases in the background gamma-radiation dose may occur due to the removal of (222)Rn and (220)Rn progeny from the atmosphere by wet deposition mechanisms. This contribution has been measured using a Geiger-Muller detector at the Atomic Weapons Establishment (Aldermaston, UK) during July 2005-April 2006. The results are approximated by a log-normal distribution and there were nine separate occurrences of the gamma-radiation dose exceeding 125% of the geometric mean value. The increases were associated with periods of heavy rainfall, although no correlation was evident between the dose rate and the amount of rainfall, as increased rainfall dilutes the activity further rather than increasing its atmospheric removal. The events were preceded by periods of fine weather and atmospheric stability that allow for the build-up of (222)Rn and (220)Rn progeny. Similar increases in gamma-radiation dose have been measured at a nearby monitoring station situated approximately 11 miles from Aldermaston. Increases in gamma-radiation dose during heavy rainfall have also been observed throughout the UK, that followed the trajectory of an air mass. All events decreased to typical values within 1-2 h as the water permeated into the ground below and the radioactivity decayed away.


Assuntos
Radiação de Fundo , Raios gama , Armas Nucleares , Monitoramento de Radiação/métodos , Radioisótopos/análise , Estações do Ano , Tempo (Meteorologia) , Doses de Radiação , Sensibilidade e Especificidade , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...