Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Acta Radiol ; 64(10): 2722-2730, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37649280

RESUMO

BACKGROUND: Detecting occlusions of coronary artery bypass grafts using non-contrast computed tomography (CT) series is understudied and underestimated. PURPOSE: To evaluate morphological findings for the diagnosis of chronic coronary artery bypass graft occlusion on non-contrast CT and investigate performance statistics for potential use cases. MATERIAL AND METHODS: Seventy-three patients with coronary artery bypass grafts who had CT angiography of the chest (non-contrast and arterial phases) were retrospectively included. Two readers applied pre-set morphologic findings to assess the patency of a bypass graft on non-contrast series. These findings included vessel shape (linear-band like), collapsed lumen and surgical graft marker without a visible vessel. Performance was tested using the simultaneously acquired arterial phase series as the ground truth. RESULTS: The per-patient diagnostic accuracy for occlusion was 0.890 (95% confidence interval = 0.795-0.951). Venous grafts overall had an 88% accuracy. None of the left internal mammary artery to left anterior descending artery arterial graft occlusions were detected. The negative likelihood ratio for an occluded graft that is truly patent was 0.121, demonstrating a true post-test probability of 97% for identifying a patent graft as truly patent given a prevalence of 20% occlusion at a median 8.4 years post-surgery. Neither years post-surgery, nor number of vessels was associated with a significant decrease in reader accuracy. CONCLUSION: Evaluation of coronary bypass grafts for chronic occlusion on non-contrast CT based off vessel morphology is feasible and accurate for venous grafts. Potential use cases include low-intermediate risk patients with chest pain or shortness of breath for whom non-contrast CT was ordered, or administration of iodine-based contrast is contraindicated.


Assuntos
Ponte de Artéria Coronária , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Angiografia Coronária/métodos , Grau de Desobstrução Vascular , Sensibilidade e Especificidade , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem
3.
Am Surg ; 89(9): 3915-3916, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37204767

RESUMO

Phlegmasia alba dolens is a rare sequela of acute extensive venothrombus of the iliofemoral segments. Rarely, phlegmasia alba dolens can also result from clotted inferior vena cava filter. A 39-year-old with protein S deficiency, and prior inferior vena cava filter placement after remote trauma presented to the emergency department with progressive bilateral lower extremity pain and swelling. Venous duplex revealed extensive bilateral deep vein thromboses from the external iliac veins to popliteal veins, as well as thrombophlebitis of the left great saphenous vein. Venography confirmed patency of the suprarenal vena cava with abrupt occlusion of the infrarenal segment at the level of the inferior vena cava filter. The filter was removed followed by endovascular thrombectomy and adjunctive venoplasty. The patient progressed well and discharged on therapeutic anticoagulation. This case illustrates that a staged endovascular approach may be utilized for acute on chronic caval thrombosis and filter removal.


Assuntos
Tromboflebite , Doenças Vasculares , Filtros de Veia Cava , Trombose Venosa , Humanos , Adulto , Filtros de Veia Cava/efeitos adversos , Tromboflebite/diagnóstico por imagem , Tromboflebite/etiologia , Tromboflebite/terapia , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia , Trombose Venosa/cirurgia , Trombectomia/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem
4.
Int J Cardiovasc Imaging ; 39(8): 1535-1546, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37148449

RESUMO

Noninvasive identification of active myocardial inflammation in patients with cardiac sarcoidosis plays a key role in management but remains elusive. T2 mapping is a proposed solution, but the added value of quantitative myocardial T2 mapping for active cardiac sarcoidosis is unknown. Retrospective cohort analysis of 56 sequential patients with biopsy-confirmed extracardiac sarcoidosis who underwent cardiac MRI for myocardial T2 mapping. The presence or absence of active myocardial inflammation in patients with CS was defined using a modified Japanese circulation society criteria within one month of MRI. Myocardial T2 values were obtained for the 16 standard American Heart Association left ventricular segments. The best model was selected using logistic regression. Receiver operating characteristic curves and dominance analysis were used to evaluate the diagnostic performance and variable importance. Of the 56 sarcoidosis patients included, 14 met criteria for active myocardial inflammation. Mean basal T2 value was the best performing model for the diagnosis of active myocardial inflammation in CS patients (pR2 = 0.493, AUC = 0.918, 95% CI 0.835-1). Mean basal T2 value > 50.8 ms was the most accurate threshold (accuracy = 0.911). Mean basal T2 value + JCS criteria was significantly more accurate than JCS criteria alone (AUC = 0.981 vs. 0.887, p = 0.017). Quantitative regional T2 values are independent predictors of active myocardial inflammation in CS and may add additional discriminatory capability to JCS criteria for active disease.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Humanos , Estudos Retrospectivos , População do Leste Asiático , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Inflamação
5.
Am Surg ; 89(9): 3908-3910, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37171974

RESUMO

A patent foramen ovale (PFO) is present in 27-35% of the population. Right to left cardiac shunts predispose patients to arterial emboli in the presence of venous thromboembolisms. Paradoxical embolus should be suspected in patients with deep venous thrombosis (DVT) and arterial emboli. A 45-year-old man with hypercoagulability and history of DVT presented with a week-long history of chest pain, shortness of breath, and left arm numbness. Imaging showed a saddle pulmonary embolus (PE) and emboli involving the aortic arch, left common carotid, and left subclavian artery. The patient proceeded with an endovascular thrombectomy of the pulmonary artery, followed by open thrombectomy. Echocardiogram confirmed a right to left intra-cardiac shunt consistent with a PFO. Paradoxical emboli are rare manifestations of venous thromboemboli in patients with right to left intra-cardiac shunts. Patients should be evaluated for these to help prevent further manifestations.


Assuntos
Embolia Paradoxal , Forame Oval Patente , Embolia Pulmonar , Trombose Venosa , Masculino , Humanos , Pessoa de Meia-Idade , Artéria Subclávia/diagnóstico por imagem , Embolia Pulmonar/etiologia , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Ecocardiografia , Embolia Paradoxal/complicações , Embolia Paradoxal/diagnóstico
6.
Am Surg ; 89(9): 3913-3914, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37205675

RESUMO

Abdominal pregnancy represents a rare subset of ectopic pregnancy with a reported incidence around one per 10,000 live births. It is associated with high fetal and maternal morbidity and mortality. In this case, we describe a 25-year-old primigravida female who presented as a trauma activation with acute hypotension following blunt trauma to the abdomen and who was found to have a viable abdominal pregnancy with placental abruption. Given hypotension and non-reassuring fetal heart tones, the decision was made to take the patient to the operating room for emergent exploratory laparotomy and cesarean section. The placenta was severely adhered to a portion of small bowel, the appendix, and the right adnexa with an approximate 20% abruption. The placenta and adhered structures were removed. In pregnant patients presenting after blunt trauma with free intraabdominal fluid and hypotension, abdominal pregnancy with abruption should be considered as an unlikely differential.


Assuntos
Hipotensão , Gravidez Abdominal , Ferimentos não Penetrantes , Gravidez , Humanos , Feminino , Adulto , Gravidez Abdominal/diagnóstico , Gravidez Abdominal/etiologia , Gravidez Abdominal/cirurgia , Cesárea , Placenta , Ferimentos não Penetrantes/complicações
7.
JACC Cardiovasc Imaging ; 15(10): 1745-1757, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36202453

RESUMO

BACKGROUND: There is little consensus on whether absence of coronary artery calcium (CAC) can identify patients with chest pain (CP) who can safely avoid additional downstream testing. OBJECTIVES: The purpose of this study was to conduct a systematic review and meta-analysis investigating the utility of CAC assessment for ruling out obstructive coronary artery disease (CAD) among patients with stable and acute CP, at low-to-intermediate risk of obstructive CAD undergoing coronary computed tomography angiography (CTA). METHODS: The authors searched online databases for studies published between 2005 and 2021 examining the relationship between CAC and obstructive CAD (≥50% coronary luminal narrowing) on coronary CTA among patients with stable and acute CP. RESULTS: In this review, the authors included 19 papers comprising 79,903 patients with stable CP and 13 papers including 12,376 patients with acute CP undergoing simultaneous CAC and coronary CTA assessment. Overall, 45% (95% CI: 40%-50%) of patients with stable CP and 58% (95% CI: 50%-66%) of patients with acute CP had CAC = 0. The negative predictive values for CAC = 0 ruling out obstructive CAD were 97% (95% CI: 96%-98%) and 98% (95% CI: 96%-99%) among patients with stable and acute CP, respectively. Additionally, the prevalence of nonobstructive CAD among those with CAC = 0 was 13% (95% CI: 10%-16%) among those with stable CP and 9% (95% CI: 5%-13%) among those with acute CP. A CAC score of zero predicted a low incidence of major adverse cardiac events among patients with stable CP (0.5% annual event rate) and acute CP (0.8% overall event rate). CONCLUSIONS: Among over 92,000 patients with stable or acute CP, the absence of CAC was associated with a very low prevalence of obstructive CAD, a low prevalence of nonobstructive CAD, and a low annualized risk of major adverse cardiac events. These findings support the role of CAC = 0 in a value-based health care delivery model as a "gatekeeper" for more advanced imaging among patients presenting with CP.


Assuntos
Cálcio , Doença da Artéria Coronariana , Dor no Peito/diagnóstico por imagem , Dor no Peito/epidemiologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Humanos , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco
8.
Visc Med ; 38(4): 288-294, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36160820

RESUMO

Background: The purpose of this study was to develop and validate reliable computed tomography (CT) imaging criteria for the diagnosis of gastric band slippage. Material and Methods: We retrospectively evaluated 67 patients for gastric band slippage using CT. Of these, 14 had surgically proven gastric band slippage (study group), 22 had their gastric bands removed for reasons other than slippage (control group 1), and 31 did not require removal (control group 2). All of the studies were read independently by two radiologists in a blinded fashion. The "O" sign, phi angle, amount of inferior displacement from the esophageal hiatus, and gastric pouch size were used to create CT diagnostic criteria. Standard statistical methods were used. Results: There was good overall interobserver agreement for diagnosis of gastric band slippage using CT diagnostic criteria (kappa = 0.83). Agreement was excellent for the "O" sign (kappa = 0.93) and phi angle (intraclass correlation coefficient = 0.976). The "O" sign, inferior displacement from the hiatus >3.5 cm, and gastric pouch volume >55 cm3 each had 100% positive predictive value. A phi angle <20° or >60° had the highest negative predictive value (NPV) (98%). Of all CT diagnostic criteria, enlarged gastric pouch size was most correlated with band slippage with an AUC of 0.991. Conclusion: All four imaging parameters were useful in evaluating for gastric band slippage on CT, with good interobserver agreement. Of these parameters, enlarged gastric pouch size was most correlated with slippage and abnormal phi angle had the highest NPV.

9.
Cureus ; 14(7): e27037, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35989840

RESUMO

Vascular spasm is well known and studied in the arterial system. There are only a few cases reported related to central venous spasms. We present the case of a 63-year-old male with an extensive medical history, including deep vein thrombosis (DVT), who underwent peripheral insertion of a central catheter in his left upper extremity with subsequent development of left upper extremity edema. The central catheter was removed before the patient underwent a contrast-enhanced computed tomography of the chest which revealed severe narrowing of the left brachiocephalic vein, consistent with venospasm in the clinical setting. Nitroglycerin might be useful to prevent vasospasm, or it might also be used for treatment. In our case, the catheter was removed, and no subsequent treatment was necessary.

10.
BMC Infect Dis ; 22(1): 637, 2022 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-35864468

RESUMO

BACKGROUND: Airspace disease as seen on chest X-rays is an important point in triage for patients initially presenting to the emergency department with suspected COVID-19 infection. The purpose of this study is to evaluate a previously trained interpretable deep learning algorithm for the diagnosis and prognosis of COVID-19 pneumonia from chest X-rays obtained in the ED. METHODS: This retrospective study included 2456 (50% RT-PCR positive for COVID-19) adult patients who received both a chest X-ray and SARS-CoV-2 RT-PCR test from January 2020 to March of 2021 in the emergency department at a single U.S. INSTITUTION: A total of 2000 patients were included as an additional training cohort and 456 patients in the randomized internal holdout testing cohort for a previously trained Siemens AI-Radiology Companion deep learning convolutional neural network algorithm. Three cardiothoracic fellowship-trained radiologists systematically evaluated each chest X-ray and generated an airspace disease area-based severity score which was compared against the same score produced by artificial intelligence. The interobserver agreement, diagnostic accuracy, and predictive capability for inpatient outcomes were assessed. Principal statistical tests used in this study include both univariate and multivariate logistic regression. RESULTS: Overall ICC was 0.820 (95% CI 0.790-0.840). The diagnostic AUC for SARS-CoV-2 RT-PCR positivity was 0.890 (95% CI 0.861-0.920) for the neural network and 0.936 (95% CI 0.918-0.960) for radiologists. Airspace opacities score by AI alone predicted ICU admission (AUC = 0.870) and mortality (0.829) in all patients. Addition of age and BMI into a multivariate log model improved mortality prediction (AUC = 0.906). CONCLUSION: The deep learning algorithm provides an accurate and interpretable assessment of the disease burden in COVID-19 pneumonia on chest radiographs. The reported severity scores correlate with expert assessment and accurately predicts important clinical outcomes. The algorithm contributes additional prognostic information not currently incorporated into patient management.


Assuntos
COVID-19 , Aprendizado Profundo , Adulto , Inteligência Artificial , COVID-19/diagnóstico por imagem , Humanos , Prognóstico , Radiografia Torácica , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios X , Raios X
11.
Radiol Cardiothorac Imaging ; 4(3): e210205, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35833168

RESUMO

Purpose: To evaluate the value of using left ventricular (LV) long-axis shortening (LAS) derived from coronary CT angiography (CCTA) to predict mortality in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). Materials and Methods: Patients with severe AS who underwent CCTA for preprocedural TAVR planning between September 2014 and December 2019 were included in this retrospective study. CCTA covered the whole cardiac cycle in 10% increments. Image series reconstructed at end systole and end diastole were used to measure LV-LAS. All-cause mortality within 24 months of follow-up after TAVR was recorded. Cox regression analysis was performed, and hazard ratios (HRs) are presented with 95% CIs. The C index was used to evaluate model performance, and the likelihood ratio χ2 test was performed to compare nested models. Results: The study included 175 patients (median age, 79 years [IQR, 73-85 years]; 92 men). The mortality rate was 22% (38 of 175). When adjusting for predictive clinical confounders, it was found that LV-LAS could be used independently to predict mortality (adjusted HR, 2.83 [95% CI: 1.13, 7.07]; P = .03). In another model using the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM), LV-LAS remained significant (adjusted HR, 3.38 [95 CI: 1.48, 7.72]; P = .004), and its use improved the predictive value of the STS-PROM, increasing the STS-PROM C index from 0.64 to 0.71 (χ2 = 29.9 vs 19.7, P = .001). In a subanalysis of patients with a normal LV ejection fraction (LVEF), the significance of LV-LAS persisted (adjusted HR, 3.98 [95 CI: 1.56, 10.17]; P = .004). Conclusion: LV-LAS can be used independently to predict mortality in patients undergoing TAVR, including those with a normal LVEF.Keywords: CT Angiography, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Outcomes Analysis, Cardiomyopathies, Left Ventricle, Aortic Valve Supplemental material is available for this article. © RSNA, 2022See also the commentary by Everett and Leipsic in this issue.

12.
AJR Am J Roentgenol ; 219(5): 743-751, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35703413

RESUMO

BACKGROUND. Deep learning-based convolutional neural networks have enabled major advances in development of artificial intelligence (AI) software applications. Modern AI applications offer comprehensive multiorgan evaluation. OBJECTIVE. The purpose of this article was to evaluate the impact of an automated AI platform integrated into clinical workflow for chest CT interpretation on radiologists' interpretation times when evaluated in a real-world clinical setting. METHODS. In this prospective single-center study, a commercial AI software solution was integrated into clinical workflow for chest CT interpretation. The software provided automated analysis of cardiac, pulmonary, and musculoskeletal findings, including labeling, segmenting, and measuring normal structures as well as detecting, labeling, and measuring abnormalities. AI-annotated images and autogenerated summary results were stored in the PACS and available to interpreting radiologists. A total of 390 patients (204 women, 186 men; mean age, 62.8 ± 13.3 [SD] years) who underwent out-patient chest CT between January 19, 2021, and January 28, 2021, were included. Scans were randomized using 1:1 allocation between AI-assisted and non-AI-assisted arms and were clinically interpreted by one of three cardiothoracic radiologists (65 scans per arm per radiologist; total of 195 scans per arm) who recorded interpretation times using a stopwatch. Findings were categorized according to review of report impressions. Interpretation times were compared between arms. RESULTS. Mean interpretation times were significantly shorter in the AI-assisted than in the non-AI-assisted arm for all three readers (289 ± 89 vs 344 ± 129 seconds, p < .001; 449 ± 110 vs 649 ± 82 seconds, p < .001; 281 ± 114 vs 348 ± 93 seconds, p = .01) and for readers combined (328 ± 122 vs 421 ± 175 seconds, p < .001). For readers combined, the mean difference was 93 seconds (95% CI, 63-123 seconds), corresponding with a 22.1% reduction in the AI-assisted arm. Mean interpretation time was also shorter in the AI-assisted arm compared with the non-AI-assisted arm for contrast-enhanced scans (83 seconds), noncontrast scans (104 seconds), negative scans (84 seconds), positive scans without significant new findings (117 seconds), and positive scans with significant new findings (92 seconds). CONCLUSION. Cardiothoracic radiologists exhibited a 22.1% reduction in chest CT interpretations times when they had access to results from an automated AI support platform during real-world clinical practice. CLINICAL IMPACT. Integration of the AI support platform into clinical workflow improved radiologist efficiency.


Assuntos
Inteligência Artificial , Tomografia Computadorizada por Raios X , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Radiologistas , Redes Neurais de Computação , Estudos Retrospectivos
13.
Radiology ; 304(1): 4-17, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35638923

RESUMO

Minimally invasive strategies to treat valvular heart disease have emerged over the past 2 decades. The use of transcatheter aortic valve replacement in the treatment of severe aortic stenosis, for example, has recently expanded from high- to low-risk patients and became an alternative treatment for those with prohibitive surgical risk. With the increase in transcatheter strategies, multimodality imaging, including echocardiography, CT, fluoroscopy, and cardiac MRI, are used. Strategies for preprocedural imaging strategies vary depending on the targeted valve. Herein, an overview of preprocedural imaging strategies and their postprocessing approaches is provided, with a focus on CT. Transcatheter aortic valve replacement is reviewed, as well as less established minimally invasive treatments of the mitral and tricuspid valves. In addition, device-specific details and the goals of CT imaging are discussed. Future imaging developments, such as peri-procedural fusion imaging, machine learning for image processing, and mixed reality applications, are presented.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Ecocardiografia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Imagem Multimodal , Tomografia Computadorizada por Raios X/métodos
14.
Acad Radiol ; 29(8): 1178-1188, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35610114

RESUMO

RATIONALE AND OBJECTIVES: The burden of coronavirus disease 2019 (COVID-19) airspace opacities is time consuming and challenging to quantify on computed tomography. The purpose of this study was to evaluate the ability of a deep convolutional neural network (dCNN) to predict inpatient outcomes associated with COVID-19 pneumonia. MATERIALS AND METHODS: A previously trained dCNN was tested on an external validation cohort of 241 patients who presented to the emergency department and received a chest computed tomography scan, 93 with COVID-19 and 168 without. Airspace opacity scoring systems were defined by the extent of airspace opacity in each lobe, totaled across the entire lungs. Expert and dCNN scores were concurrently evaluated for interobserver agreement, while both dCNN identified airspace opacity scoring and raw opacity values were used in the prediction of COVID-19 diagnosis and inpatient outcomes. RESULTS: Interobserver agreement for airspace opacity scoring was 0.892 (95% CI 0.834-0.930). Probability of each outcome behaved as a logistic function of the opacity scoring (25% intensive care unit admission at score of 13/25, 25% intubation at 17/25, and 25% mortality at 20/25). Length of hospitalization, intensive care unit stay, and intubation were associated with larger airspace opacity score (p = 0.032, 0.039, 0.036, respectively). CONCLUSION: The tested dCNN was highly predictive of inpatient outcomes, performs at a near expert level, and provides added value for clinicians in terms of prognostication and disease severity.


Assuntos
COVID-19 , Aprendizado Profundo , Algoritmos , COVID-19/diagnóstico por imagem , Teste para COVID-19 , Humanos , Pacientes Internados , Pulmão/diagnóstico por imagem , Morbidade , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios X/métodos
15.
J Thorac Imaging ; 37(5): 307-314, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35475983

RESUMO

OBJECTIVES: We aimed to validate and test a prototype algorithm for automated dual-energy computed tomography (DECT)-based myocardial extracellular volume (ECV) assessment in patients with various cardiomyopathies. METHODS: This retrospective study included healthy subjects (n=9; 61±10 y) and patients with cardiomyopathy (n=109, including a validation cohort n=60; 68±9 y; and a test cohort n=49; 69±11 y), who had previously undergone cardiac DECT. Myocardial ECV was calculated using a prototype-based fully automated algorithm and compared with manual assessment. Receiver-operating characteristic analysis was performed to test the algorithm's ability to distinguish healthy subjects and patients with cardiomyopathy. RESULTS: The fully automated method led to a significant reduction of postprocessing time compared with manual assessment (2.2±0.4 min and 9.4±0.7 min, respectively, P <0.001). There was no significant difference in ECV between the automated and manual methods ( P =0.088). The automated method showed moderate correlation and agreement with the manual technique ( r =0.68, intraclass correlation coefficient=0.66). ECV was significantly higher in patients with cardiomyopathy compared with healthy subjects, regardless of the method used ( P <0.001). In the test cohort, the automated method yielded an area under the curve of 0.98 for identifying patients with cardiomyopathies. CONCLUSION: Automated ECV estimation based on DECT showed moderate agreement with the manual method and matched with previously reported ECV values for healthy volunteers and patients with cardiomyopathy. The automatically derived ECV demonstrated an excellent diagnostic performance to discriminate between healthy and diseased myocardium, suggesting that it could be an effective initial screening tool while significantly reducing the time of assessment.


Assuntos
Cardiomiopatias , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Fibrose , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia
16.
Eur Radiol ; 32(8): 5256-5264, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35275258

RESUMO

OBJECTIVES: To evaluate the effectiveness of a novel artificial intelligence (AI) algorithm for fully automated measurement of left atrial (LA) volumes and function using cardiac CT in patients with atrial fibrillation. METHODS: We included 79 patients (mean age 63 ± 12 years; 35 with atrial fibrillation (AF) and 44 controls) between 2017 and 2020 in this retrospective study. Images were analyzed by a trained AI algorithm and an expert radiologist. Left atrial volumes were obtained at cardiac end-systole, end-diastole, and pre-atrial contraction, which were then used to obtain LA function indices. Intraclass correlation coefficient (ICC) analysis of the LA volumes and function parameters was performed and receiver operating characteristic (ROC) curve analysis was used to compare the ability to detect AF patients. RESULTS: The AI was significantly faster than manual measurement of LA volumes (4 s vs 10.8 min, respectively). Agreement between the manual and automated methods was good to excellent overall, and there was stronger agreement in AF patients (all ICCs ≥ 0.877; p < 0.001) than controls (all ICCs ≥ 0.799; p < 0.001). The AI comparably estimated LA volumes in AF patients (all within 1.3 mL of the manual measurement), but overestimated volumes by clinically negligible amounts in controls (all by ≤ 4.2 mL). The AI's ability to distinguish AF patients from controls using the LA volume index was similar to the expert's (AUC 0.81 vs 0.82, respectively; p = 0.62). CONCLUSION: The novel AI algorithm efficiently performed fully automated multiphasic CT-based quantification of left atrial volume and function with similar accuracy as compared to manual quantification. Novel CT-based AI algorithm efficiently quantifies left atrial volumes and function with similar accuracy as manual quantification in controls and atrial fibrillation patients. KEY POINTS: • There was good-to-excellent agreement between manual and automated methods for left atrial volume quantification. • The AI comparably estimated LA volumes in AF patients, but overestimated volumes by clinically negligible amounts in controls. • The AI's ability to distinguish AF patients from controls was similar to the manual methods.


Assuntos
Fibrilação Atrial , Idoso , Inteligência Artificial , Fibrilação Atrial/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
17.
Heliyon ; 8(2): e08962, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35243082

RESUMO

BACKGROUND: Determination of the total number and size of all pulmonary metastases on chest CT is time-consuming and as such has been understudied as an independent metric for disease assessment. A novel artificial intelligence (AI) model may allow for automated detection, size determination, and quantification of the number of pulmonary metastases on chest CT. OBJECTIVE: To investigate the utility of a novel AI program applied to initial staging chest CT in breast cancer patients in risk assessment of mortality and survival. METHODS: Retrospective imaging data from a cohort of 226 subjects with breast cancer was assessed by the novel AI program and the results validated by blinded readers. Mean clinical follow-up was 2.5 years for outcomes including cancer-related death and development of extrapulmonary metastatic disease. AI measurements including total number of pulmonary metastases and maximum nodule size were assessed by Cox-proportional hazard modeling and adjusted survival. RESULTS: 752 lung nodules were identified by the AI program, 689 of which were identified in 168 subjects having confirmed lung metastases (Lmet+) and 63 were identified in 58 subjects without confirmed lung metastases (Lmet-). When compared to the reader assessment, AI had a per-patient sensitivity, specificity, PPV and NPV of 0.952, 0.639, 0.878, and 0.830. Mortality in the Lmet + group was four times greater compared to the Lmet-group (p = 0.002). In a multivariate analysis, total lung nodule count by AI had a high correlation with overall mortality (OR 1.11 (range 1.07-1.15), p < 0.001) with an AUC of 0.811 (R2 = 0.226, p < 0.0001). When total lung nodule count and maximum nodule diameter were combined there was an AUC of 0.826 (R2 = 0.243, p < 0.001). CONCLUSION: Automated AI-based detection of lung metastases in breast cancer patients at initial staging chest CT performed well at identifying pulmonary metastases and demonstrated strong correlation between the total number and maximum size of lung metastases with future mortality. CLINICAL IMPACT: As a component of precision medicine, AI-based measurements at the time of initial staging may improve prediction of which breast cancer patients will have negative future outcomes.

18.
Eur J Radiol ; 149: 110212, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35220197

RESUMO

OBJECTIVES: To investigate the predictive value of right ventricular long axis strain (RV-LAS) derived by cardiac computed tomography angiography (CCTA) for mortality in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). METHODS: We retrospectively included patients with severe AS undergoing TAVR (n = 168, median 79 years). Parameters of RV function including RV-LAS and RV ejection fraction (RVEF) were assessed using pre-procedural systolic and diastolic CCTA series. The tricuspid annulus diameter (TAD) and diameter of the main pulmonary artery (mPA) were also assessed. All-cause mortality was recorded post-TAVR. Cox regression was used and results are presented with hazard ratio (HR) and 95% confidence interval (CI). Harrell's c-index was used to assess the performance of different models and the likelihood ratio test was used to compare nested models. RESULTS: Thirty-eight deaths (22.6%) occurred over a median follow-up of 21 months. RV-LAS > -11.42% (HR 2.86, 95% CI 1.44-5.67, p = 0.003), LVEF (HR 0.98, 95% CI 0.96-0.996; p = 0.02), TAD (HR 1.05, 95% CI 1.01-1.10, p = 0.02) and mPA diameter (HR 1.09, 95% CI 1.02-1.16, p = 0.01) were associated with mortality on univariable analysis. In a multivariable model, only RV-LAS (HR 2.36, 95% CI 1.04-5.36, p = 0.04) remained as an independent predictor of all-cause mortality. RV-LAS significantly improved the predictive power of the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) (c-index 0.700 vs 0.637; p = 0.01). CONCLUSION: RV-LAS was an independent predictor of all-cause mortality in patients with severe AS undergoing TAVR, outperformed anatomical markers such as TAD and mPA diameter, and could potentially improve the current risk-stratifying tool.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
19.
J Cardiovasc Comput Tomogr ; 16(3): 245-253, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34969636

RESUMO

BACKGROUND: Low-dose computed tomography (LDCT) are performed routinely for lung cancer screening. However, a large amount of nonpulmonary data from these scans remains unassessed. We aimed to validate a deep learning model to automatically segment and measure left atrial (LA) volumes from routine NCCT and evaluate prediction of cardiovascular outcomes. METHODS: We retrospectively evaluated 273 patients (median age 69 years, 55.5% male) who underwent LDCT for lung cancer screening. LA volumes were quantified by three expert cardiothoracic radiologists and a prototype AI algorithm. LA volumes were then indexed to the body surface area (BSA). Expert and AI LA volume index (LAVi) were compared and used to predict cardiovascular outcomes within five years. Logistic regression with appropriate univariate statistics were used for modelling outcomes. RESULTS: There was excellent correlation between AI and expert results with an LAV intraclass correlation of 0.950 (0.936-0.960). Bland-Altman plot demonstrated the AI underestimated LAVi by a mean 5.86 â€‹mL/m2. AI-LAVi was associated with new-onset atrial fibrillation (AUC 0.86; OR 1.12, 95% CI 1.08-1.18, p â€‹< â€‹0.001), HF hospitalization (AUC 0.90; OR 1.07, 95% CI 1.04-1.13, p â€‹< â€‹0.001), and MACCE (AUC 0.68; OR 1.04, 95% CI 1.01-1.07, p â€‹= â€‹0.01). CONCLUSION: This novel deep learning algorithm for automated measurement of LA volume on lung cancer screening scans had excellent agreement with manual quantification. AI-LAVi is significantly associated with increased risk of new-onset atrial fibrillation, HF hospitalization, and major adverse cardiac and cerebrovascular events within 5 years.


Assuntos
Fibrilação Atrial , Aprendizado Profundo , Neoplasias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Detecção Precoce de Câncer , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
20.
Acad Radiol ; 29 Suppl 2: S108-S117, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33714665

RESUMO

RATIONALE AND OBJECTIVES: Research on implementation of artificial intelligence (AI) in radiology workflows and its impact on reports remains scarce. In this study, we aim to assess if an AI platform would perform better than clinical radiology reports in evaluating noncontrast chest computed tomography (CT) scans. MATERIALS AND METHODS: Consecutive patients who had undergone noncontrast chest CT were retrospectively identified. The radiology reports were reviewed in a binary fashion for reporting of pulmonary lesions, pulmonary emphysema, aortic dilatation, coronary artery calcifications (CAC), and vertebral compression fractures (VCF). CT scans were then processed using an AI platform. The reports' findings and the AI results were subsequently compared to a consensus read by two board-certificated radiologists as reference. RESULTS: A total of 100 patients (mean age: 64.2 ± 14.8 years; 57% males) were included in this study. Aortic segmentation and calcium quantification failed to be processed by AI in 2 and 3 cases, respectively. AI showed superior diagnostic performance in identifying aortic dilatation (AI: sensitivity: 96.3%, specificity: 81.4%, AUC: 0.89) vs (Reports: sensitivity: 25.9%, specificity: 100%, AUC: 0.63), p <0.001; and CAC (AI: sensitivity: 89.8%, specificity: 100, AUC: 0.95) vs (Reports: sensitivity: 75.4%, specificity: 94.9%, AUC: 0.85), p = 0.005. Reports had better performance than AI in identifying pulmonary lesions (Reports: sensitivity: 97.6%, specificity: 100%, AUC: 0.99) vs (AI: sensitivity: 92.8%, specificity: 82.4%, AUC: 0.88), p = 0.024; and VCF (Reports: sensitivity:100%, specificity: 100%, AUC: 1.0) vs (AI: sensitivity: 100%, specificity: 63.7%, AUC: 0.82), p <0.001. A comparable diagnostic performance was noted in identifying pulmonary emphysema on AI (sensitivity: 80.6%, specificity: 66.7%. AUC: 0.74) and reports (sensitivity: 74.2%, specificity: 97.1%, AUC: 0.86), p = 0.064. CONCLUSION: Our results demonstrate that incorporating AI support platforms into radiology workflows can provide significant added value to clinical radiology reporting.


Assuntos
Fraturas por Compressão , Radiologia , Fraturas da Coluna Vertebral , Idoso , Inteligência Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...