Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Membranes (Basel) ; 13(7)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37505013

RESUMO

Phosphate recovery from different second streams using electrodialysis (ED) is a promising step to a nutrients circular economy. However, the relatively low ED performance hinders the widespread adoption of this environmentally sound method. The formation of "bonded species" between phosphates and the weakly basic fixed groups (primary and secondary amines) of the anion exchange membrane can be the cause of decrease in current efficiency and increase in energy consumption. ED processing of NaxH(3-x)PO4 alkaline solutions and the use of intense current modes promote the formation of a bipolar junction from negatively charged bound species and positively charged fixed groups. This phenomenon causes a change in the shape of current-voltage curves, increase in resistance, and an enhancement in proton generation during long-term operation of anion-exchange membrane with weakly basic fixed groups. Shielding of primary and secondary amines with a modifier containing quaternary ammonium bases significantly improves ED performance in the recovery of phosphates from NaxH(3-x)PO4 solution with pH 4.5. Indeed, in the limiting and underlimiting current modes, 40% of phosphates are recovered 1.3 times faster, and energy consumption is reduced by 1.9 times in the case of the modified membrane compared to the pristine one. Studies were performed using a new commercial anion exchange membrane CJMA-2.

2.
Membranes (Basel) ; 13(5)2023 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-37233516

RESUMO

The entrance of even a small amount of phosphorus compounds into natural waters leads to global problems that require the use of modern purification technologies. This paper presents the results of testing a hybrid electrobaromembrane (EBM) method for the selective separation of Cl- (always present in phosphorus-containing waters) and H2PO4- anions. Separated ions of the same charge sign move in an electric field through the pores of a nanoporous membrane to the corresponding electrode, while a commensurate counter-convective flow in the pores is created by a pressure drop across the membrane. It has been shown that EBM technology provides high fluxes of ions being separated across the membrane as well as a high selectivity coefficient compared to other membrane methods. During the processing of solution containing 0.05 M NaCl and 0.05 M NaH2PO4, the flux of phosphates through a track-etched membrane can reach 0.29 mol/(m2×h). Another possibility for separation is the EBM extraction of chlorides from the solution. Its flux can reach 0.40 mol/(m2×h) through the track-etched membrane and 0.33 mol/(m2×h) through a porous aluminum membrane. The separation efficiency can be very high by using both the porous anodic alumina membrane with positive fixed charges and the track-etched membrane with negative fixed charges due to the possibility of directing the fluxes of separated ions in opposite sides.

3.
Membranes (Basel) ; 13(5)2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37233570

RESUMO

New processes for recycling valuable materials from used lithium-ion batteries (LIBs) need to be developed. This is critical to both meeting growing global demand and mitigating the electronic waste crisis. In contrast to the use of reagent-based processes, this work shows the results of testing a hybrid electrobaromembrane (EBM) method for the selective separation of Li+ and Co2+ ions. Separation is carried out using a track-etched membrane with a pore diameter of 35 nm, which can create conditions for separation if an electric field and an oppositely directed pressure field are applied simultaneously. It is shown that the efficiency of ion separation for a lithium/cobalt pair can be very high due to the possibility of directing the fluxes of separated ions to opposite sides. The flux of lithium through the membrane is about 0.3 mol/(m2 × h). The presence of coexisting nickel ions in the feed solution does not affect the flux of lithium. It is shown that the EBM separation conditions can be chosen so that only lithium is extracted from the feed solution, while cobalt and nickel remain in it.

4.
Membranes (Basel) ; 12(11)2022 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-36363620

RESUMO

Anion-exchange membranes modified with a polyquaternium-22 (PQ-22) polymer were studied for their use in electrodialysis. The use of PQ-22 for modification makes it possible to "replace" weakly basic amino groups on the membrane surface with quaternary amino groups. It was found that the content of quaternary amino groups in PQ-22 is higher than the content of carboxyl groups, which is the reason for the effectiveness of this polymer even when modifying Ralex AHM-PES membranes that initially contain only quaternary amino groups. In the case of membranes containing weakly basic amino groups, the PQ-22 polymer modification efficiency is even higher. The surface charge of the modified MA-41P membrane increased, while the limiting current density on the current-voltage curves increased by more than 1.5 times and the plateau length decreased by 2.5 times. These and other characteristics indicate that the rate of water splitting decreased and the electroconvective mixing at the membrane surface intensified, which was confirmed by direct visualization of vortex structures. Increasing the surface charge of the commercial MA-41P anion-exchange membrane, reducing the rate of water splitting, and enhancing electroconvection leads to mitigated scaling on its surface during electrodialysis.

5.
Membranes (Basel) ; 12(8)2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-36005679

RESUMO

The contact angle between a membrane surface and a waterdrop lying on its surface provides important information about the hydrophilicity/hydrophobicity of the membrane. This method is well-developed for solid non-swelling materials. However, ion-exchange membranes (IEMs) are gel-like solids that swell in liquids. When an IEM is exposed to air, its degree of swelling changes rapidly, making it difficult to measure the contact angle. In this paper, we examine the known experience of measuring contact angles and suggest a simple equipment that allows the membrane to remain swollen during measurements. An optimized protocol makes it possible to obtain reliable and reproducible results. Measuring parameters such as drop size, water dosing speed and others are optimized. Contact angle measurements are shown for a large number of commercial membranes. These data are supplemented with values from other surface characteristics from optical and profilometric measurements.

6.
Membranes (Basel) ; 10(8)2020 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-32722470

RESUMO

Recently developed and produced by Hefei Chemjoy Polymer Material Co. Ltd., homogeneous CJMC-3 and CJMC-5 cation-exchange membranes (CJMCED) are characterized. The membrane conductivity in NaCl, Na2SO4, and CaCl2 solutions, permeability in respect to the NaCl and CaCl2 diffusion, transport numbers, current-voltage curves (CVC), and the difference in the pH (DpH) of the NaCl solution at the desalination compartment output and input are examined for these membranes in comparison with a well-studied commercial Neosepta CMX cation-exchange membrane produced by Astom Corporation, Japan. It is found that the conductivity, CVC (at relatively low voltages), and water splitting rate (characterized by DpH) for both CJMCED membranes are rather close to these characteristics for the CMX membrane. However, the diffusion permeability of the CJMCED membranes is significantly higher than that of the CMX membrane. This is due to the essentially more porous structure of the CJMCED membranes; the latter reduces the counterion permselectivity of these membranes, while allowing much easier transport of large ions, such as anthocyanins present in natural dyes of fruit and berry juices. The new membranes are promising for use in electrodialysis demineralization of brackish water and natural food solutions.

7.
Membranes (Basel) ; 10(6)2020 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-32560542

RESUMO

One way to enhance mass transfer and reduce fouling in wastewater electrodialysis is stimulation of electroconvective mixing of the solution adjoining membranes by modifying their surfaces. Several samples were prepared by casting the perfluorosulfonic acid (PFSA) polymer film doped with TiO2 nanoparticles onto the surface of the heterogeneous cation-exchange membrane MK-40. It is found that changes in surface characteristics conditioned by such modification lead to an increase in the limiting current density due to the stimulation of electroconvection, which develops according to the mechanism of electroosmosis of the first kind. The greatest increase in the current compared to the pristine membrane can be obtained by modification with the film being 20 µm thick and containing 3 wt% of TiO2. The sample containing 6 wt% of TiO2 provides higher mass transfer in overlimiting current modes due to the development of nonequilibrium electroconvection. A 1.5-fold increase in the thickness of the modifying film reduces the positive effect of introducing TiO2 nanoparticles due to (1) partial shielding of the nanoparticles on the surface of the modified membrane; (2) a decrease in the tangential component of the electric force, which affects the development of electroconvection.

8.
Membranes (Basel) ; 10(3)2020 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-32168842

RESUMO

Despite the growing interest in pulsed electric field modes in membrane separation processes, there are currently not many works devoted to studying the effect of the surface properties and composition of ion-exchange membranes on their efficiency in these modes. In this paper, we have shown the effect of increasing mass transfer using different kinds of ion-exchange membranes (heterogeneous and homogeneous with smooth, undulated, and rough surfaces) during electrodialysis in the pulsed electric field modes at underlimiting and overlimiting currents. It was found that the maximum increment in the average current is achieved when the average potential corresponds to the right-hand edge of the limiting current plateau of the voltammetric curve, i.e., at the maximum resistance of the system in the DC mode. For the first time, the development of electroconvective vortices was visualized in pulsed electric field modes and it was experimentally shown that even at relatively low frequencies, a non-uniform concentration field is preserved at the time of a pause, which stimulates the rapid development of electroconvection when pulses are switched on again. In the case of relatively high pulse frequencies, the electroconvective vortices formed during a pulse lapse do not completely decay during a pause; they only slightly decrease in size.

9.
Membranes (Basel) ; 9(1)2019 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-30641931

RESUMO

Coating ion exchange membranes with polyelectrolyte has been proven to be a cheap way to reduce concentration polarization and increase limiting current (for polyelectrolytes carrying fixed groups of the same sign of charge with respect to the membrane bulk), to create high monovalent selectivity, and to add the function of H⁺/OH- ions generation (for polyelectrolytes bearing fixed groups of the opposite sign of charge with respect to the membrane bulk). In the latter case, the balance between the counterion transport and the H⁺/OH- ions generation is affected by parameters of the substrate and the modifying layer. In this study we investigated the electrochemical characteristics of homogeneous Neosepta AMX-Sb and heterogeneous MA-41P membranes coated with one, two, or three layers of oppositely charged polyelectrolyte (the maximum thickness of each layer was 5 µm). It was found that the limiting current decreased earlier and the generation of H⁺/OH- ions was stronger in the case of the heterogeneous membrane. The shift in the pH of the solution depended more on the generation of H⁺/OH- ions at the modifying layer/solution interface than on the generation at the membrane/modifying layer interface, and in all cases water splitting started in the same range of potential drops over the membrane.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA