Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38387342

RESUMO

A rapid and practicable analytical method for the measurement of short-chain fatty acids (SCFAs) in human plasma was developed. The extraction procedure involved the use of acidified water and methyl tert-butyl ether (MTBE), while the separation and detection of SCFAs, including acetic, propionic, and butyric acids was carried out by using gas chromatography-mass spectrometry (GC-MS) technique. The novelty of the research involves reducing the analysis time (less than 7 min) by using the novel fast GC-MS method. A narrow-bore GC capillary column of dimensions 30 m × 0.25 mm ID × 0.25 µm df with acid-modified poly(ethylene glycol) stationary phase was employed for the chromatographic separation. The signals of target compounds were acquired in selected ion monitoring (SIM) mode monitoring a quantifier ion (Q) and two qualifier ions (q1 and q2). Linearity of the method, limits of detection (LoD) and quantification (LoQ) were evaluated. In detail, regression coefficients of the calibration curves were between 0.9960 and 0.9933; LoDs ranged from 0.02 µM to 0.03 µM, while LoQs from 0.06 µM to 0.10 µM.


Assuntos
Ácidos Graxos Voláteis , Éteres Metílicos , Humanos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Ácidos Graxos Voláteis/análise , Limite de Detecção , Butiratos/análise , Éteres Metílicos/análise , Ácidos Graxos
2.
Artigo em Inglês | MEDLINE | ID: mdl-37451138

RESUMO

The proposed research was focused on the development of a gas chromatography-tandem mass spectrometry (GC-QqQ-MS) method under milder electron ionization (EI) conditions for the assay of vitamin D metabolites in human serum. Efficiency of three different silylation agents was evaluated for the conversion of vitamin D species into trimethylsilyl (TMS) derivatives, among which N-methyl-N-(trimethylsilyl)-trifluoroacetamide (MSTFA) proved to be the most effective. Indeed, the MSTFA reagent was able to convert in TMS ether even the 25-hydroxyl vitamin D derivative that, as known, possesses steric hindrance problems. The separation of vitamin D compounds was obtained in about 11.5 min using a narrow-bore column of dimensions 30 m × 0.25 mm ID × 0.10 µm df with a poly(5% diphenyl/95% dimethyl siloxane) stationary phase. The mass spectrometry ionization of the silylated derivatives was performed under milder EI conditions (20-eV energy) that, respect to common 70-eV energy, generated scan mass spectra with higher relative and absolute intensities of high-mass diagnostic ions, along with a reduced abundance of the low-mass. The signals of the ionized compounds were acquired in multi-reaction-monitoring (MRM) mode, thus enabling the obtainment of highly-sensitive and selective quantitative data. The developed method was validated in term of linearity, accuracy, limits of detection (LoD) and quantification (LoQ). In detail, regression coefficients of the calibration curves were between 0.9959 and 0.9999; LoDs ranged from 0.06 ng mL-1 to 0.73 ng mL-1 and LoQs from 0.16 ng mL-1 to 2.45 ng mL-1. With respect to accuracy, the serum SRM 972a certified reference material (Vitamin D metabolites in frozen human serum) (Levels 1-4) was analyzed.


Assuntos
Elétrons , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Vitamina D
3.
Foods ; 12(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36766148

RESUMO

This study aimed to assess the capability of supercritical fluid extraction (SFE) as an alternative and green technique compared to Soxhlet extraction for the production of oils from Opuntia ficus-indica (OFI) seeds originating from Yemen and Italy and Opuntia dillenii (OD) seeds from Yemen. The following parameters were used for SFE extraction: a pressure of 300 bar, a CO2 flow rate of 1 L/h, and temperatures of 40 and 60 °C. The chemical composition, including the fatty acids and tocopherols (vitamin E) of the oils, was determined using chromatographic methods. The highest yield was achieved with Soxhlet extraction. The oils obtained with the different extraction procedures were all characterized by a high level of unsaturated fatty acids. Linoleic acid (≤62% in all samples) was the most abundant one, followed by oleic and vaccenic acid. Thirty triacylglycerols (TAGs) were identified in both OFI and OD seed oils, with trilinolein being the most abundant (29-35%). Vanillin, 4-hydroxybenzaldehyde, vanillic acid, and hydroxytyrosol were phenols detected in both OFI and OD oils. The highest γ-tocopherol content (177 ± 0.23 mg/100 g) was obtained through the SFE of OFI seeds from Yemen. Overall, the results highlighted the potential of SFE as green technology to obtain oils suitable for functional food and nutraceutical products.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA