Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz J Infect Dis ; 27(4): 102790, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37478898

RESUMO

The Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) pandemic demanded rapid diagnosis to isolate new COVID-19 cases and prevent disease transmission. Quantitative Real-Time Polymerase Chain Reaction (qRT-PCR) rapidly became the gold standard for diagnosis. However, due to the high cost and delay of the results, other types of diagnosis were implemented, such as COVID-19 Ag Rapid Tests and Reverse Transcription Technique followed by Loop-Mediated isothermal Amplification (RT-LAMP). In this work, we validated the use of RT-LAMP in saliva samples rather than nasopharyngeal swabs, as the collection is more comfortable. First, we selected 5 primer sets based on the limit of detection for SARS-CoV-2 RNA, then validated their sensitivity and specificity in patient samples. A total of 117 samples were analyzed by fluorometric RT-LAMP and compared with qRT-PCR results. Our results show that the use of a high-sensitive primer ORF1-a, together with a low-sensitive primer set Gene E (time to threshold of 22.9 and 36.4 minutes, respectively, using 200 copies of viral RNA), achieved sensitivity in purified RNA from saliva samples of 95.2% (95% CI 76.1‒99.8) with 90.5% specificity (95% CI 69.6‒98.8) (n = 42).As RNA purification increases the turnaround time, we tested the outcome of RT-LAMP utilizing raw saliva samples without purification. The test achieved a sensitivity of 81.8% (95% CI 59.7‒94.8) and a specificity of 90.9% (95% CI 70.8‒98.8). As a result, the accuracy of 92.9% (95% CI 80.5‒98.5) in purified RNA-saliva samples was lowered to an acceptable level of 86.4% (95% CI 72.6‒94.8) in raw saliva. Although mass vaccination has been implemented, new strains and low vaccination progress helped to spread COVID-19. This study shows that it is feasible to track new COVID-19 cases in a large population with the use of raw saliva as sample in RT-LAMP assay which yields accurate results and offers a less invasive test.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , RNA Viral/genética , Saliva , Técnicas de Diagnóstico Molecular/métodos , Sensibilidade e Especificidade , Teste para COVID-19
2.
Braz. j. infect. dis ; Braz. j. infect. dis;27(4): 102790, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513864

RESUMO

ABSTRACT The Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) pandemic demanded rapid diagnosis to isolate new COVID-19 cases and prevent disease transmission. Quantitative Real-Time Polymerase Chain Reaction (qRT-PCR) rapidly became the gold standard for diagnosis. However, due to the high cost and delay of the results, other types of diagnosis were implemented, such as COVID-19 Ag Rapid Tests and Reverse Transcription Technique followed by Loop-Mediated isothermal Amplification (RT-LAMP). In this work, we validated the use of RT-LAMP in saliva samples rather than nasopharyngeal swabs, as the collection is more comfortable. First, we selected 5 primer sets based on the limit of detection for SARS-CoV-2 RNA, then validated their sensitivity and specificity in patient samples. A total of 117 samples were analyzed by fluorometric RT-LAMP and compared with qRT-PCR results. Our results show that the use of a high-sensitive primer ORF1-a, together with a low-sensitive primer set Gene E (time to threshold of 22.9 and 36.4 minutes, respectively, using 200 copies of viral RNA), achieved sensitivity in purified RNA from saliva samples of 95.2% (95% CI 76.1-99.8) with 90.5% specificity (95% CI 69.6-98.8) (n = 42).As RNA purification increases the turnaround time, we tested the outcome of RT-LAMP utilizing raw saliva samples without purification. The test achieved a sensitivity of 81.8% (95% CI 59.7-94.8) and a specificity of 90.9% (95% CI 70.8-98.8). As a result, the accuracy of 92.9% (95% CI 80.5-98.5) in purified RNA-saliva samples was lowered to an acceptable level of 86.4% (95% CI 72.6-94.8) in raw saliva. Although mass vaccination has been implemented, new strains and low vaccination progress helped to spread COVID-19. This study shows that it is feasible to track new COVID-19 cases in a large population with the use of raw saliva as sample in RT-LAMP assay which yields accurate results and offers a less invasive test.

3.
Protein Expr Purif ; 144: 19-24, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29198976

RESUMO

Galectin-3 (Gal3) is involved in many physiological processes related to tumor growth, such as promoting angiogenesis, cell migration/invasion, resistance to apoptosis and immune response modulation. Usually the overexpression of Gal3 is a poor prognostic marker for cancer patients. Recombinant Gal3 carbohydrate domain (Gal3C) has been proposed as a useful tool to inhibit angiogenesis. So far, all production protocols reported for Gal3C production have used proteolytic cleavage of full length Gal3 and/or affinity-based purification. This involves dialysis, a time consuming step used to eliminate the elution ligand, usually lactose. In this report, we describe an alternative method to produce human recombinant Gal3C in E. coli, purified with cationic exchange and size exclusion chromatography. The recombinant protein was characterized using circular dichroism and nuclear magnetic resonance, showing a beta sheet enriched well-folded globular structure. The average yield obtained was 26 mg/L of broth and the purity was above 99%. The anti-angiogenic activity was assessed in vitro and showed a reduction of 70% and 77% in endothelial cells tubule formation upon treatment with 10 and 20 µg/mL, respectively and also had no impact on cell viability. The method described here is more suitable for both laboratory and industrial production of the potential anti-tumor Gal3C.


Assuntos
Clonagem Molecular/métodos , Galectina 3/isolamento & purificação , Proteínas Recombinantes/isolamento & purificação , Proteínas Sanguíneas , Escherichia coli/genética , Galectina 3/metabolismo , Galectinas , Humanos , Ligantes , Ligação Proteica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA