1.
J Instrum ; 9: C12032, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25729405

RESUMO

We report on the measurement of drift properties of electrons and holes in a CdTe diode grown by the travelling heating method (THM). Mobility and lifetime of both charge carriers has been measured independently at room temperature and fixed bias voltage using charge integration readout electronics. Both electrode sides of the detector have been exposed to a 241Am source in order to obtain events with full contributions of either electrons or holes. The drift time has been measured to obtain the mobility for each charge carrier. The Hecht equation has been employed to evaluate the lifetime. The measured values for µτe/h (mobility-lifetime product) are in agreement with earlier published data.

2.
J Instrum ; 82013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23750177

RESUMO

We report on the characterization of 2 mm thick CdTe diode detector with Schottky contacts to be employed in a novel conceptual design of PET scanner. Results at -8°C with an applied bias voltage of -1000 V/mm show a 1.2% FWHM energy resolution at 511 keV. Coincidence time resolution has been measured by triggering on the preamplifier output signal to improve the timing resolution of the detector. Results at the same bias and temperature conditions show a FWHM of 6 ns with a minimum acceptance energy of 500 keV. These results show that pixelated CdTe Schottky diode is an excellent candidate for the development of next generation nuclear medical imaging devices such as PET, Compton gamma cameras, and especially PET-MRI hybrid systems when used in a magnetic field immune configuration.

3.
Int J Tuberc Lung Dis ; 14(6): 786-8, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20487621

RESUMO

A collaborative project was established between the Alli Causai Foundation in Ambato, Ecuador, and the University of Genoa, Italy, to introduce the microscopic observation drug susceptibility (MODS) assay for the rapid identification of Mycobacterium tuberculosis in Ecuador. A total of 507 samples were evaluated during a 10-month period, and DNA was extracted from each isolate and sent to Genoa for confirmatory molecular analysis. M. tuberculosis was identified in 45 samples by MODS, and drug resistance was observed in approximately 21% of the isolates, with four multidrug-resistant strains detected in two patients.


Assuntos
Antituberculosos/uso terapêutico , DNA Bacteriano/genética , Farmacorresistência Bacteriana Múltipla/genética , Mutação , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Contagem de Colônia Microbiana/métodos , Equador/epidemiologia , Humanos , Incidência , Mycobacterium tuberculosis/genética , Reação em Cadeia da Polimerase , Prevalência , Estudos Retrospectivos , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico , Tuberculose Resistente a Múltiplos Medicamentos/epidemiologia
4.
Restor Neurol Neurosci ; 9(3): 151-60, 1996 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21551843

RESUMO

This paper describes some developments, made to obtain a chronic neural interface to record signals from regenerated peripheral nerves. Microperforated silicon dices, fabricated by techniques compatible with CMOS processes, were coupled in silicone nerve chambers and implanted between the severed ends of peripheral nerves in rats. Three configurations of perforated dices with 25 via-holes of 100 µm diameter, 121 via-holes of 40 µm and 400 via-holes of 10 µm were assessed. The feasibility of axonal regeneration through the dices via-holes was proved by histological and physiological methods over 3 months post-implantation. The regenerated nerves were organized in fascicles corresponding to the grid pattern of the via-holes. However, nerve regeneration was difficult and distal re-innervation delayed with respect to simple tubulization repair. The size of the via-holes and the total open area are determinants of the degree and quality of regeneration. Further improvements are needed in both the microelectrode dice design and in neurobiological stimulation of regeneration.