Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
3.
J Am Coll Cardiol ; 81(10): 979-991, 2023 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-36889877

RESUMO

BACKGROUND: An aberrant subclavian artery (ASA) (or lusoria) is the most common congenital anomaly of the aortic arch (0.5%-2.2%; female-to-male ratio 2:1 to 3:1). ASA can become aneurysmal and result in dissection, involving Kommerell's diverticulum when present and the aorta. Data of its significance in genetic arteriopathies are not available. OBJECTIVES: The purpose of this study was to assess the prevalence and complications of ASA in gene-positive and -negative nonatherosclerotic arteriopathies. MATERIALS: The series includes 1,418 consecutive patients with gene-positive (n = 854) and gene-negative arteriopathies (n = 564) diagnosed as part of institutional work-up for nonatherosclerotic syndromic and nonsyndromic arteriopathies. Comprehensive evaluation includes genetic counseling, next-generation sequencing multigene testing, cardiovascular and multidisciplinary assessment, and whole-body computed tomography angiography. RESULTS: ASA was found in 34 of 1,418 cases (2.4%), with a similar prevalence in gene-positive (n = 21 of 854, 2.5%) and gene-negative (n = 13 of 564, 2.3%) arteriopathies. Of the former 21 patients, 14 had Marfan syndrome, 5 had Loeys-Dietz syndrome, 1 had type-IV Ehlers-Danlos syndrome, and 1 had periventricular heterotopia type 1. ASA did not segregate with genetic defects. Dissection occurred in 5 of 21 patients with genetic arteriopathies (23.8%; 2 Marfan syndrome and 3 Loeys-Dietz syndrome), all with associated Kommerell's diverticulum. No dissections occurred in gene-negative patients. At baseline, none of the 5 patients with ASA dissection fulfilled criteria for elective repair according to guidelines. CONCLUSIONS: The risk of complications of ASA is higher in patients with genetic arteriopathies and is difficult to predict. In these diseases, imaging of the supra-aortic trunks should enter baseline investigations. Determination of precise indications for repair can prevent unexpected acute events such as those described.


Assuntos
Divertículo , Cardiopatias Congênitas , Síndrome de Loeys-Dietz , Síndrome de Marfan , Doenças Vasculares , Humanos , Masculino , Feminino , Síndrome de Marfan/complicações , Prevalência , Doenças Vasculares/complicações , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/anormalidades , Cardiopatias Congênitas/complicações , Aorta Torácica , Divertículo/complicações
4.
New Microbiol ; 45(4): 237-242, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36066215

RESUMO

High-resolution CT-scan (HRCT) plays a major role in the diagnosis of Nontuberculous mycobacteria lung disease (NTM-LD), but its role in follow-up is controversial. Our aim was first to conceive a radiological score able to quantify the severity of pulmonary involvement by NTM infection and, second, to check its association with the NTM-LD clinical burden. We also intended, if possible, to verify the potential influence of NTM specific treatment on the radiological score. We retrospectively collected the clinical, microbiological and radiological data of all patients who were admitted to our hospital from 1 January 2012 to 1 January 2020 with a confirmed diagnosis of NTM-LD. A radiological score was applied to evaluate lung involvement on HRCT at diagnosis and at 6-18 months follow-up. Twenty-eight patients with NTM-LD performed follow-up HRCT. No association was found between radiological and clinical score (Spearman R -0.05, 95%CI -0.41 to 0.33). Repeated measures analysis showed a significant increase in radiological score over time (change 1.11, 95%CI 0.10 to 2.11; p-value 0.032), while Mann-Whitney test did not show any difference between treated and untreated patients (p value 0.922). Further studies are needed to assess the usefulness of routine radiological follow-up in patients with NTM-LD.


Assuntos
Pneumopatias , Infecções por Mycobacterium não Tuberculosas , Humanos , Micobactérias não Tuberculosas , Estudos Retrospectivos , Infecções por Mycobacterium não Tuberculosas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Pneumopatias/diagnóstico por imagem , Pneumopatias/complicações
5.
Dig Liver Dis ; 54(12): 1614-1622, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36089523

RESUMO

Benign liver lesions are increasingly diagnosed in daily clinical practice due to the growing use of imaging techniques for the study of the abdomen in patients who have non-specific symptoms and do not have an increased risk of hepatic malignancy. They include simple or parasitic hepatic cysts and solid benign tumors which differ widely in terms of prevalence, clinical relevance, symptoms and natural history and often lead to significant clinical problems relating to diagnosis and clinical management. Following the need to have updated guidelines on the management of benign focal liver lesions, the Scientific Societies mainly involved in their management have promoted the drafting of a new dedicated document. This document was drawn up according to the present Italian rules and methodologies necessary to produce clinical, diagnostic, and therapeutic guidelines based on evidence. Here we present the second part of the guideline, concerning the diagnosis and clinical management of hemangioma, focal nodular hyperplasia, and hepatocellular adenoma.


Assuntos
Doenças do Sistema Digestório , Neoplasias Hepáticas , Humanos , Abdome , Neoplasias Hepáticas/diagnóstico , Itália
6.
Dig Liver Dis ; 54(11): 1469-1478, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36089525

RESUMO

Benign liver lesions are increasingly diagnosed in daily clinical practice due to the growing use of imaging techniques for the study of the abdomen in patients who have non-specific symptoms and do not have an increased risk of hepatic malignancy. They include simple or parasitic cysts and solid benign tumors which differ widely in terms of prevalence, clinical relevance, symptoms and natural history and often lead to significant clinical problems relating to diagnosis and clinical management. Following the need to have updated guidelines on the management of benign focal liver lesions, the Scientific Societies mainly involved in their management have promoted the drafting of a new dedicated document. This document was drawn up according to the present Italian rules and methodologies necessary to produce clinical, diagnostic, and therapeutic guidelines based on evidence. Here we present the first part of the guideline, concerning the characterization of focal hepatic lesions detected by ultrasound, and the diagnosis and clinical management of simple and parasitic hepatic cysts, and of polycystic liver disease.


Assuntos
Cistos , Doenças do Sistema Digestório , Neoplasias Hepáticas , Humanos , Abdome , Cistos/diagnóstico por imagem , Cistos/terapia , Neoplasias Hepáticas/diagnóstico por imagem , Itália
7.
Ultraschall Med ; 43(5): e36-e48, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35850145

RESUMO

This first position paper of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) on professional standards presents a common position across the different medical professions within EFSUMB regarding optimal standards for the performing and reporting of ultrasound examinations by any professional ultrasound operator. It describes general aspects of professionality that ensure procedure quality, effectiveness, efficiency, and sustainability in virtually all application fields of medical ultrasound. Recommendations are given related to safety and indication of ultrasound examinations, requirements for examination rooms, structured examination, systematic reporting of results, and management, communication and archiving of ultrasound data. The print version of this article is a short version. The long version is published online.


Assuntos
Sociedades Médicas , Humanos , Ultrassonografia/métodos
8.
Ultraschall Med ; 43(5): 456-463, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35850146

RESUMO

This first position paper of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) on professional standards presents a common position across the different medical professions within EFSUMB regarding optimal standards for the performing and reporting of ultrasound examinations by any professional ultrasound operator. It describes general aspects of professionality that ensure procedure quality, effectiveness, efficiency, and sustainability in virtually all application fields of medical ultrasound. Recommendations are given related to safety and indication of ultrasound examinations, requirements for examination rooms, structured examination, systematic reporting of results, and management, communication and archiving of ultrasound data. The print version of this article is a short version. The long version is published online.


Assuntos
Sociedades Médicas , Humanos , Ultrassonografia/métodos
10.
Med Princ Pract ; 30(4): 355-360, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33721865

RESUMO

OBJECTIVE: The aim of the study was to retrospectively evaluate the prevalence of reported and unreported potentially important incidental findings (PIFs) in consecutive nonenhanced abdominal CTs performed specifically for renal colic in the urgent setting. METHODS: One radiologist, blinded to the finalized report, retrospectively re-evaluated nonenhanced abdominal CTs performed from January to December 2017 on adult patients from the emergency department with the specific request of urgent evaluation for renal colic, searching for PIFs. RESULTS: The CTs of 312 patients were included in the study. Thirty-eight findings were reported in 38 different CTs, whereas the re-evaluation added 47 unreported findings in 47 different CTs, adding to total of 85 findings (27%). The difference in the proportion of reported and unreported PIFs between the original report and re-evaluation was significant (p < 0.001). No significant difference was found between the age of patients with and without reported findings. The proportion of potentially important findings did not vary significantly among the 3 shifts in the original report and in re-evaluation. The most frequent findings, both reported and unreported, were pleural effusion, lymphadenopathies, and liver nodules. CONCLUSIONS: Potentially important additional findings are frequently present in urgent nonenhanced abdominal CTs performed for renal colic, and many are not described in the finalized reports. Radiologists should take care not to underreport PIFs even in the urgent setting because of the possible consequences on the patient's health and in order to avoid legal issues, while at the same time satisfying the need for timely and efficient reporting.


Assuntos
Achados Incidentais , Nefrolitíase , Cólica Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Cólica Renal/epidemiologia , Estudos Retrospectivos
11.
Indian J Radiol Imaging ; 31(4): 1053-1056, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35136528

RESUMO

Primary bone lymphoma is a rare entity and it usually occurs in long bones. Primary mandibular involvement is very rare, and it usually shows unspecific features, mimicking odontogenic inflammatory lesions. We present the unusual case of a diffuse large B-cell lymphoma (DLBCL) of the right mandibular body in a 91-year-old woman, who presented with acute pain in the mandibular region initially suspicious for odontogenic abscess. No significant findings were seen on orthopantomography (OPG) and her almost complete edentulism made the diagnosis of abscess unlikely. Computed tomography and magnetic resonance images showed an expansive mass around the right mandibular body with erosion of cortical bone and involving the right mandibular canal and nerve. Final diagnosis of DLBCL was pathologically proven. The presence of odontogenic-like pain in nearly complete edentulism should be suspicious for malignancy, and it needs further diagnostic workup despite the absence of signs on OPG.

13.
J Ultrasound Med ; 40(7): 1325-1332, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32960457

RESUMO

OBJECTIVES: The main aim was to assess the performance and cutoff value for the detection of liver steatosis (grade S > 0) with the Attenuation Imaging-Penetration (ATI-Pen) algorithm available on the Aplio i-series ultrasound systems (Canon Medical Systems, Otawara, Japan). The magnetic resonance imaging-derived proton density fat fraction (MRI-PDFF) was used as the reference standard. Secondary aims were to compare the results to those obtained with the previous ATI algorithm (Attenuation Imaging-General [ATI-Gen]) and with the controlled attenuation parameter (CAP) and to generate a regression equation between ATI-Pen and ATI-Gen values. METHODS: Consecutive adult patients potentially at risk of liver steatosis were prospectively enrolled. Each patient underwent ultrasound quantification of liver steatosis with ATI-Pen and ATI-Gen and a CAP assessment with the FibroScan system (Echosens, Paris, France). The MRI-PDFF evaluation was performed within a week. The correlations between ATI-Pen, ATI-Gen, the CAP, and the MRI-PDFF were analyzed with the Pearson rank correlation coefficient. The diagnostic performance of ATI-Pen, ATI-Gen, and the CAP was assessed with receiver operating characteristic curves and an area under the receiver operating characteristic curve (AUROC) analysis. RESULTS: Seventy-two individuals (31 male and 41 female) were enrolled. Correlation coefficients of ATI-Pen, ATI-Gen, and the CAP with the MRI-PDFF were 0.78, 0.83, and 0.58, respectively. The AUROCs of ATI-Pen, ATI-Gen, and the CAP for detecting steatosis (S > 0) were 0.90 (95% confidence interval, 0.81-0.96), 0.92 (0.82-0.98), and 0.85 (0.74-0.92), and the cutoffs were greater than 0.69 dB/cm/MHz, greater than 0.62 dB/cm/MHz, and greater than 273 dB/m. The regression equation between ATI-Pen and ATI-Gen was ATI-Pen = 0.88 ATI-Gen + 0.13. CONCLUSIONS: Attenuation Imaging is a reliable tool for detecting liver steatosis, showing an excellent correlation with the MRI-PDFF and high performance with AUROCs of 0.90 or higher.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Adulto , Feminino , França , Humanos , Japão , Fígado , Imageamento por Ressonância Magnética , Masculino , Curva ROC , Tecnologia
14.
Curr Med Imaging ; 16(9): 1154-1160, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33135611

RESUMO

BACKGROUND: When undergoing magnetic resonance (MR) exams, patients need to lie still in a noisy and enclosed environment for a long time. This condition, together with the anxiety burden related to the possible implications of the scan results, can entail a diagnostic outcome of poor quality. OBJECTIVE: The aim of the study was to evaluate the personal perception and experience of adult patients undergoing unenhanced musculoskeletal MR. METHODS: Consecutive outpatients undergoing unenhanced MR of spine, knee or shoulder were asked to respond to a 10-item questionnaire at the end of the exam. RESULTS: 263 patients (54% males, mean age 50.6 ±15.8 years, range 18-83 years) completed the questionnaire. Patients declared that the most disturbing elements of the exam were forced immobility and noise (30% in both cases). Females perceived significantly higher degree of anxiety than males (56% vs. 21%, p<0.001). Exam duration was correctly perceived by 83% of the population. Patients' satisfaction was generally high (mean above 9 over 10). CONCLUSION: Explanations and clarifications given before the exam were considered satisfactory by the patients. Despite some negative aspects such as noise, immobility and anxiety especially in females, patients' satisfaction with our service was high, as well as the willingness to return.


Assuntos
Satisfação do Paciente , Coluna Vertebral , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Percepção , Inquéritos e Questionários , Adulto Jovem
16.
J Clin Imaging Sci ; 10: 46, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32874751

RESUMO

OBJECTIVES: This study aims to first measure patient doses during computed tomography (CT) chest, abdomen, and extremities procedures for evaluation lymphedema, and second to estimate the radiation dose-related risks during the procedures. MATERIAL AND METHODS: Radiation effective doses from CT lymphography procedures quantified using CT machines from different vendors. After the calibration of CT systems, the data collected for a total of 28 CT lymphography procedures. Effective and organ doses extrapolated using national radiological protection software based on Monte Carlo simulation. RESULTS: The mean patient doses for chest and abdomen procedures in term of CTDIvol (mGy) and DLP (mGy.cm) are 10.0 ± 3 and 425 ± 222 and 24 ± 12 and 1118 ± 812 for CT 128 and CT 16 slice, respectively. The mean DLP (mGy.cm) for extremities was 320 ± 140 and 424 ± 212 for CT 128 and CT 16 slice, in that order. CONCLUSION: Patients' dose showed significant differences due to variation in the scan length and clinical indication. Organs lay in the primary beam received high radiation doses especially in the chest region which increases the probability of radiation-induced cancer. The current patient's doses are higher compared to the previous studies.

18.
Acta Radiol ; 61(12): 1653-1660, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32131609

RESUMO

BACKGROUND: The capacitive micromachined ultrasound transducer (CMUT) is a new ultrasound (US) probe manufactured by state-of-the-art cutting-edge semi-conductor micromachined electro-mechanical systems (MEMS) technology. PURPOSE: To demonstrate the peculiar characteristics of each probe and the limitations that should be improved. MATERIAL AND METHODS: This study was performed from March to April 2018. The only inclusion criterion was the presence of disease, so all patients with musculoskeletal, skin, and subcutaneous pathology were included. A total of 66 patients entered this study. The exams of each patient, with both probes, were evaluated retrospectively and independently by three radiologists. Panoramicity of the images, the definition of superficial structures (<2 cm of depth), the definition of deep structures (>2 cm), and Doppler signal were assessed. A 5-point scale was used for each parameter. RESULTS: A total of 89 pathologies were detected. The mean of score for 4G-CMUT was higher than L64 for the panoramicity of the images and the definition of the deep structures. Instead, the mean score for L64 was higher than for 4G-CMUT in the evaluation of superficial structures and Doppler signal. A statistically significant difference was found (P < 0.05). CONCLUSION: CMUT is a breakthrough in US technology. It allows the use of a single probe for different US examinations. The musculoskeletal, skin, and subcutaneous US can be evaluated with a piezoelectric linear transducer or CMUT. In the present study, the overall diagnostic performance was similar. Improvements in CMUT will provide even more dynamic and flexible imaging capabilities by a transducer, with a wider bandwidth.


Assuntos
Doenças Musculoesqueléticas/diagnóstico por imagem , Transdutores , Ultrassonografia Doppler/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Estudos Retrospectivos
19.
J Ultrasound Med ; 39(8): 1649-1664, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32124997

RESUMO

Wall shear stress (WSS) is considered as a key factor for atherosclerosis development. Previous WSS research based on pulsed wave Doppler (PWD) showed limitations in complex flows. To improve accuracy for nonlaminar flow, a commercial ultrasound vector flow imaging (UVFI)-based WSS calculation is proposed. Errors for PWD are presented theoretically when flow is not laminar. Based on this, simulations of WSS calculations between PWD and UVFI were set up for different turbulent flows. Our simulations show that UVFI has obviously better performance than PWD in WSS calculations. Wall shear stress results in different flow conditions at carotid bifurcations are described.


Assuntos
Artérias Carótidas , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/diagnóstico por imagem , Humanos , Resistência ao Cisalhamento , Estresse Mecânico , Ultrassonografia
20.
Magn Reson Imaging ; 68: 158-166, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32057940

RESUMO

PURPOSE: To assess the ability and reproducibility of Non-contrast Magnetic Resonance Lymphography (NMRL) in detecting and quantify lymphedema, using a semiquantitative scoring system. METHODS AND MATERIAL: This is a monocentric retrospective study of 134 consecutive patients with a clinical diagnosis of limb lymphedema who performed a Non-contrast Magnetic Resonance Lymphography (NMRL) at our Institution between November 2014 and February 2017. Lymphedema was classified based both on clinical and radiologic evaluation. An NMRL total score was obtained for each limb's segment and compared to the clinical grade, used as reference standard. NMRL intra-observer, inter-observer variability and intraclass correlation were calculated. NMRL sensitivity, specificity, and accuracy in identifying lymphedema were provided. Based on score distribution an NMRL four-stage system was developed. RESULTS: NMRL showed 92% sensitivity, 77% specificity and 82% accuracy in identifying lymphedema. An almost perfect agreement was obtained by expert operators, while substantial agreement was obtained by non-expert operators. Substantial agreement resulted also for the inter-observer variability (Cohen's Kappa K = 0.73, CI 95% [0.69-0.78]). The intra-class correlation showed an almost perfect relationship both by expert and non-expert operators. Excellent correlation between clinical grade and NMRL score and between clinical grade and NMRL stage were found for each segment. CONCLUSIONS: NMRL is a confident and reproducible exam with high sensitivity, good specificity and high accuracy in lymphedema detection; the semiquantitative NMRL score resulted a reliable and reproducible tool able to quantify lymphedema severity.


Assuntos
Linfedema/diagnóstico por imagem , Linfografia/métodos , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...