Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Analyst ; 148(17): 4053-4063, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37529888

RESUMO

Early and accurate detection of infection by pathogenic microorganisms, such as Plasmodium, the causative agent of malaria, is critical for clinical diagnosis and ultimately determines the patient's outcome. We have combined a polystyrene-based microfluidic device with an immunoassay which utilises Surface-Enhanced Raman Spectroscopy (SERS) to detect malaria. The method can be easily translated to a point-of-care testing format and shows excellent sensitivity and specificity, when compared to the gold standard for laboratorial detection of Plasmodium infections. The device can be fabricated in less than 30 min by direct patterning on shrinkable polystyrene sheets of adaptable three-dimensional microfluidic chips. To validate the microfluidic system, samples of P. falciparum-infected red blood cell cultures were used. The SERS-based immunoassay enabled the detection of 0.0012 ± 0.0001% parasitaemia in a P. falciparum-infected red blood cell culture supernatant, an ∼7-fold higher sensitivity than that attained by most rapid diagnostic tests. Our approach successfully overcomes the main challenges of the current Plasmodium detection methods, including increased reproducibility, sensitivity, and specificity. Furthermore, our system can be easily adapted for detection of other pathogens and has excellent properties for early diagnosis of infectious diseases, a decisive step towards lowering their high burden on healthcare systems worldwide.


Assuntos
Malária Falciparum , Malária , Parasitos , Plasmodium , Humanos , Animais , Poliestirenos , Plasmodium falciparum , Reprodutibilidade dos Testes , Malária/diagnóstico , Malária Falciparum/diagnóstico , Sensibilidade e Especificidade , Dispositivos Lab-On-A-Chip
2.
Sci Rep ; 6: 19514, 2016 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-26786701

RESUMO

Mechano-electrical writing and reading in polyaniline (PANI) thin film are demonstrated via metal-polymer contact electrification mechanism (CEM). An innovative conception for a non-destructive self-powered writable-readable data sheet is presented which can pave the way towards new type of stress induced current harvesting devices. A localized forced deformation of the interface has been enacted by pressing the atomic force microscopic probe against the polymer surface, allowing charge transfer between materials interfaces. The process yields a well-defined charge pattern by transmuting mechanical stress in to readable information. The average of output current increment has been influenced from 0.5 nA to 15 nA for the applied force of 2 nN to 14 nN instead of electrical bias. These results underscore the importance of stress-induced current harvesting mechanism and could be scaled up for charge patterning of polymer surface to writable-readable data sheet. Time evolutional current distribution (TECD) study of the stress-induced patterned PANI surface shows the response of readability of the recorded data with time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...