Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vet Anaesth Analg ; 50(6): 502-506, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37806870

RESUMO

OBJECTIVE: To evaluate the accuracy with which veterinary anaesthetists and nurses of different experience draw up small volumes of liquid. STUDY DESIGN: Prospective blinded randomized study. METHODS: A group of seven European College of Veterinary Anaesthesia and Analgesia (ECVAA) diplomates, six ECVAA residents and six anaesthesia nurses participated in the study. For each participant, five target volumes between 0.01 and 1.0 mL were randomly allocated. They were drawn up 20 times in random order using a 1 mL syringe attached to a 23 gauge needle. A total of 1900 measurements were analysed. An investigator filled the syringe and needle dead space with water for injection before each experiment. The change in mass of the syringe once filled to the target volume was used to calculate the actual volume of liquid drawn up. RESULTS: Large errors were made with measurements < 0.04 mL, so they were excluded from the statistical analysis. There was a significant effect of the target volume (p < 0.001) and of the order (p < 0.01). For each mL increase in the target volume, the absolute error decreased by 4% and from the first to the hundredth withdrawal each participant's absolute error decreased by 1%. The target volume was underestimated in 52.3% of measurements, 42% were overestimated and 5.7% were on target. None of the between-subject predictor variables approached significance. CONCLUSIONS AND CLINICAL RELEVANCE: Accuracy of veterinary anaesthetists and nurses in drawing up medications decreases as the target volume becomes smaller. Small veterinary patients receive small volumes of anaesthetic drugs with higher risks of overdosing compared with larger dogs. Years of experience and staff grade are not associated with greater accuracy. Large percentage errors may be seen with target volumes less than 0.04 mL. Dilutions are recommended for volumes > 0.19 mL in 1 mL syringe.


Assuntos
Anestesia , Anestésicos , Animais , Cães , Humanos , Anestésicos/administração & dosagem , Anestesistas/estatística & dados numéricos , Injeções/estatística & dados numéricos , Injeções/veterinária , Estudos Prospectivos , Enfermeiros Anestesistas/estatística & dados numéricos , Anestesia/métodos , Anestesia/estatística & dados numéricos , Anestesia/veterinária
2.
Vet Anaesth Analg ; 48(4): 532-536, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34059461

RESUMO

OBJECTIVE: To measure the dead space of various syringe volumes and brands and a range of needles gauges commonly used in clinical practice, and to compare the results to the International Organization for Standardization (ISO) standard 7886-1:2018. STUDY DESIGN: Prospective observational study. METHODS: Syringes of five brands and seven volumes: 1, 2.5, 5, 10, 20, 30, and 60 mL, 10 of each, 10 1 mL low dead space syringes and 10 23, 21 and 18 gauge needles were analysed. Syringe dead space was estimated by weighing each syringe, drawing up and expelling its rated volume of water for injection and re-weighing the syringe. The difference in mass between the two measurements was calculated and converted to a volume based on the density of water. The dead space of the needles was estimated using a similar technique: each needle was attached to a 1 mL syringe of known dead space. A Mettler electronic balance was used for the measurements. Mean dead space was calculated for each syringe volume and needle gauge. Data were compared to the ISO standard. RESULTS: Syringe dead space for 1 and 2.5 mL was less than 0.07 mL. For 5 mL syringes four of five brands, and for 10 mL syringes one of five brands failed to comply with the ISO; the dead space was greater than 0.075 and 0.1 mL, respectively. For the 20, 30, 60 mL syringes the dead space was less than 0.2 mL. Needle dead space was 0.05 mL for 23 and 21 gauge, and 0.07 mL for 18 gauge, similar in order of magnitude to syringe dead space. CONCLUSIONS: The dead space of syringes differs between brands, and some do not meet the ISO standard. When calculating the amount of drug lost due to dead space, both that of the syringe and needle used should be considered.


Assuntos
Agulhas , Seringas , Animais , Injeções/veterinária , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...