Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioelectrochemistry ; 157: 108655, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38310811

RESUMO

In this study, an electrochemical chemosensor that utilizes a conductive polymer-based molecularly imprinted polymer (MIP) surface for rapid and reliable determination of CA125 was devised. A novel method has been applied to fabricate CA125 imprinted polypyrrole nanotubes (MI-PPy NT) via vapor deposition polymerization (VDP) as a recognition element for highly selective and sensitive determination of CA125. The chemosensor was prepared by immobilizing MI-PPy NT onto screen-printed gold electrodes (Au-SPE) and the performance of the sensor was evaluated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in terms of selectivity, sensitivity, linear dynamic concentration range (LDR) and limit of detection (LOD). The MI-PPy NT@Au-SPE sensor exhibited high sensitivity (68.57 µA per decade) to the CA125 concentration ranging from 0.1 U mL-1 to 100 U mL-1 at an LOD of 0.4 U mL-1 with a correlation coefficient of 0.9922. The developed chemosensors with their novel design combined with a facile fabrication method, prove to be promising as future state-of-the-art biosensors.


Assuntos
Impressão Molecular , Nanotubos , Neoplasias , Humanos , Polímeros/química , Técnicas Eletroquímicas/métodos , Biomarcadores Tumorais , Impressão Molecular/métodos , Pirróis/química , Limite de Detecção , Eletrodos
2.
Environ Technol ; 43(19): 2934-2947, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33779527

RESUMO

Nitrogen oxide (NOx) emissions cause significant impacts on the environment and must therefore be controlled even more stringently. This requires the development of cost-effective removal strategies which simultaneously create value-added by-products or energy from the waste. This study aims to treat gaseous nitric oxide (NO) by hollow-fibre membrane biofilm reactor (HFMBfR) in the presence of nitrite (NO2-) and evaluate nitrous oxide (N2O) emissions formed as an intermediate product during the denitrification process. Accumulated N2O can be utilised in methane oxidation as an oxidant to produce energy. In the first stage of the study, the HFMBfR was operated by feeding only gaseous NO as the nitrogen source. During this period, the best performance was achieved with 92% NO removal efficiency (RE). In the second stage, both NO gas and NO2- were supplied to the system, and 91% NO and 99% NO2- reduction were achieved simultaneously with the maximum N2O generation of 386 ± 31 ppm. Lower influent carbon to nitrogen (C/N) ratios, such as 4.5 and 2.0, and higher NO2--N loading rate of 158 mg N day-1 favoured N2O generation. An improved NO removal rate and N2O accumulation were seen with the increasing amount of PO43- in the medium. The 16S rDNA sequencing analysis revealed that Alicycliphilus denitrificans and Pseudomonas putida were the dominant species. The study shows that an HFMBfR can be successfully used to eliminate both NO2- and gaseous NO and simultaneously generate N2O by adjusting the system parameters such as C/N ratio, NO2- and PO43- loading.


Assuntos
Nitritos , Óxido Nitroso , Biofilmes , Reatores Biológicos , Carbono , Desnitrificação , Óxido Nítrico , Nitrogênio
3.
Bioelectrochemistry ; 135: 107553, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32442773

RESUMO

Applications of molecular techniques to elucidate identity or function using biomarkers still remain highly empirical and biosensors are no exception. In the present study, target-specific oligonucleotide probes for E. coli K12 were designed thermodynamically and applied in an electrochemical DNA biosensor setup. Biosensor was prepared by immobilization of a stem-loop structured probe, modified with a thiol functional group at its 5' end and a biotin molecule at its 3' end, on a gold electrode through self-assembly. Mercaptopropionic acid (MPA) was used to optimize the surface probe density of the electrode. Hybridization between the immobilized probe and the target DNA was detected via the electrochemical response of streptavidin-horseradish peroxidase in the presence of the substrate. The amperometric response showed a linear relationship with the target DNA concentration, ranging from 10 and 400 nM, with a correlation coefficient of 0.989. High selectivity and good repeatability of the biosensor showed that the thermodynamic approach to oligonucleotide probe design can be used in development of electrochemical DNA biosensors.


Assuntos
Técnicas Biossensoriais , Sondas de DNA/química , Técnicas Eletroquímicas/métodos , Termodinâmica , Biotina/química , Peroxidase do Rábano Silvestre/química , Limite de Detecção , Propionatos/química , Reprodutibilidade dos Testes , Estreptavidina/química
4.
Mater Sci Eng C Mater Biol Appl ; 32(1): 18-23, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23177766

RESUMO

This study describes the construction and characterization of an amperometric nitrate biosensor based on the Polypyrrole (PPy)/Carbon nanotubes (CNTs) film. Nitrate reductase (NR) was both entrapped into the growing PPy film and chemically immobilized via the carboxyl groups of CNTs to the CNT/PPy film electrode. The optimum amperometric response for nitrate was obtained in 0.1 M phosphate buffer solution (PBS), pH 7.5 including 0.1 M lithium chloride and 7 mM potassium ferricyanide with an applied potential of 0.13 V (vs. Ag/AgCl, 3 M NaCl). Sensitivity was found to be 300 nA/mM in a linear range of 0.44-1.45 mM with a regression coefficient of 0.97. The biosensor response showed a higher linear range in comparison to standard nitrate analysis methods which were tested in this study and NADH based nitrate biosensors. A minimum detectable concentration of 0.17 mM (S/N=3) with a relative standard deviation (RSD) of 5.4% (n=7) was obtained for the biosensor. Phenol and glucose inhibit the electrochemical reaction strictly at a concentration of 1 µg/L and 20 mg/L, respectively. The biosensor response retained 70% of its initial response over 10 day usage period when used everyday.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Nanotubos de Carbono/química , Nitrato Redutase/química , Nitratos/análise , Biofilmes , Soluções Tampão , Eletroquímica/métodos , Enzimas Imobilizadas/química , Glucose/química , Limite de Detecção , Fenol/química , Polímeros/química , Pirróis/química , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...