Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Turk Gogus Kalp Damar Cerrahisi Derg ; 26(2): 237-245, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32082740

RESUMO

BACKGROUND: This study aims to present our experiences on endovascular and hybrid treatment of peripheral arterial diseases. METHODS: Between March 2008 and April 2016, 86 patients who underwent endovascular treatment and 17 patients who underwent hybrid treatment for peripheral arterial disease in our clinic were retrospectively analyzed. The treatment approaches, success of treatments, complications and outcomes of these patients were studied. RESULTS: No mortality was seen during the procedures. Following the procedure, the patients were hospitalized in the intensive care unit under standard heparin treatment for six hours at least. Anticoagulation was maintained with low-molecular-weighted heparin for three days, followed by dual oral antiaggregant (acetylsalicylic acid 100 mg + clopidogrel 75 mg). Repeated Doppler ultrasonography revealed no in-stent thrombosis or restenosis at the site of ballooning during hospitalization. None of the patients with normal renal functions preoperatively experienced severe renal failure. Although nearly all femorodistal interventions were performed in the antegrade way, none of the patients had bleeding complications at the site of intervention. All patients were discharged within 1 to 16 days. CONCLUSION: Endovascular and hybrid modalities are safe and comfortable in the treatment of peripheral arterial diseases for vascular surgeons having a hybrid room.

2.
Cardiovasc J Afr ; 26(2): e9-11, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25855239

RESUMO

Post-traumatic pseudo-aneurysm is a rare complication of penetrating vascular injury. Endovascular stent implantation has become an alternative approach in the management of this pathology. In our case, we present a brachial artery pseudo-aneurysm that was treated with endovascular stent implantation, and removal of a broken catheter part with a three-dimensional snare device.


Assuntos
Falso Aneurisma/cirurgia , Implante de Prótese Vascular , Artéria Braquial/patologia , Lesões do Sistema Vascular/cirurgia , Ferimentos por Arma de Fogo/cirurgia , Adulto , Falso Aneurisma/etiologia , Angiografia , Artéria Braquial/transplante , Procedimentos Endovasculares/métodos , Humanos , Masculino , Falha de Prótese , Ajuste de Prótese , Dispositivos de Acesso Vascular/estatística & dados numéricos , Lesões do Sistema Vascular/complicações , Ferimentos por Arma de Fogo/complicações , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...