Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dev Neuropsychol ; 45(4): 211-231, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32264704

RESUMO

The field of neuropsychology is becoming increasingly responsive to addressing the specific needs of an ever-growing Hispanic/Latinx population. As such, bilingualism and bilingual education are at the forefront of considerations for neuropsychologists. This paper examines models of bilingual academic instruction and levels of bilingualism and how they impact neuropsychological findings and diagnostic determinations in pediatrics. The present case series highlights five children assessed in a pediatric medical setting. Various profiles are analyzed to highlight the intricacies in assessment that must be considered. These findings present a set of considerations as a step toward a systematic approach to bilingual neuropsychological assessment.


Assuntos
Cognição/fisiologia , Hispânico ou Latino/psicologia , Multilinguismo , Criança , Feminino , Humanos , Masculino , Testes Neuropsicológicos , Estados Unidos
2.
Contemp Clin Trials Commun ; 10: 137-140, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30023447

RESUMO

BACKGROUND: The Vibrant Soundbridge middle ear implant and the Bonebridge bone conducting hearing device are hearing implants that use radio frequency transmission to send information from the sound processor to the internal transducer. This reduces the risk of skin problems and infection but requires a more involved surgical procedure than competitor skin penetrating devices. It is not known whether more complex surgery will lead to additional complications. There is little information available on the reliability of these systems and adverse medical or surgical events. The primary research question is to determine the reliability and complication rate for the Vibrant Soundbridge and Bonebridge. The secondary research question explores changes in quality of life following implantation of the devices. The tertiary research question looks at effectiveness via changes in auditory performance. METHOD: The study was designed based on a combination of a literature search, two clinician focus groups and expert review.A multi-centre longitudinal observational study was designed. There are three study groups, two will have been implanted prior to the start of the study and one group, the prospective group, will be implanted after initiation of the study. Outcomes are surgical questionnaires, measures of quality of life, user satisfaction and speech perception tests in quiet and in noise. CONCLUSION: This is the first multi-centre study to look at these interventions and includes follow up over time to understand effectiveness, reliability, quality of life and complications.

3.
Adv Exp Med Biol ; 894: 115-123, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27080652

RESUMO

There is a wide range in performance for cochlear implant (CI) users and there is some evidence to suggest that implant fitting can be modified to improve performance if electrodes that do not provide distinct pitch information are de-activated. However, improvements in performance may not be the same for users of all CI devices; in particular for those with Cochlear devices using n-of-m strategies (ACE or SPEAK).The goal of this research was to determine for users of Cochlear devices (CP810 or CP900 series processors) if speech perception could be improved when indiscriminable electrodes were de-activated and this was also compared to when the same number of discriminable electrodes were de-activated.A cross-over study was conducted with 13 adult CI users who received experimental maps with de-activated channels for a minimum of 2 months and these were compared to optimised clinical maps.The findings showed that there were no significant benefits of electrode de-activation on speech perception and that there was a significant deterioration in spectro-temporal ripple perception when electrodes were switched off. There were no significant differences between de-activation of discriminable or indiscriminable electrodes.These findings suggest that electrode de-activation with n-of-m strategies may not be beneficial.


Assuntos
Implantes Cocleares , Percepção da Fala , Adulto , Estudos Cross-Over , Eletrodos , Humanos , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...