Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Fr J Urol ; : 102644, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38759842

RESUMO

OBJECTIVES: To characterize and compare in vitro the surfaces of ureteral stents(STENTS) before utilization. METHODS: Our in vitro experiment included six unused STENTS models: three double-pigtail with side orifices(ImaJin and Stenostent(Coloplast©,France), TriaSoft(BostonScientific©,USA)), two double-pigtail without side orifice(Vortek-TumorStent (Coloplast©,France), Urosoft-TumorStent(Bard-Angiomed©,Germany)) and one single-pigtail(J-Fil(Rocamed©,Monaco)). STENTS were made of polyurethane except for ImaJin(silicone). For all STENTS, four parts of the stent were specifically analyzed under high-resolution scanning electron microscopy(HR-SEM,FEI-XL40(Philips©,France): surface core, lateral orifice, ureteral loop, and black marking surface. Each experiment was repeated with three different samples from three different stents. STENTS analysis included multiple imperfection searches, defined as irregularities>10µm. RESULTS: All STENTS presented imperfections with no discernible differences. Imperfections were mainly located on the stent loop and on the lateral orifice. For STENTS without side orifice (J-Fil, Urosoft) imperfections were also reported, on the beveled cut as well as the distal loop orifice. Marking surfaces examinations found defects in the Urosoft and imperfections in the ImaJin and Stenostent. The Triasoft presented a better smoothness on marking surfaces compared to other STENTS. Additional matter was reported on the loop distal orifice for J-Fil and ImaJin but all STENTS presented irregular cross-sectional aeras. CONCLUSION: All ureteral stents are not perfectly smooth even before utilization. Imperfections were noticed regardless to stent composition or shape, and could play a role in the incrustation phenomenon, is association with inner irregularities, infection, and urine composition. Both manufacturing and material could have an impact on the stent external surface's smoothness. [[[fr]]]Resumen Objectifs: Caractériser et comparer in vitro les surfaces des endoprothèses urétérales (EU) avant leur utilisation. Méthodes: Notre étude in vitro comprenait six modèles d'EU non utilisées : deux double J avec orifices latéraux (ImaJin et Stenostent(Coloplast©,France), TriaSoft(BostonScientific©,USA)), deux double J sans orifice latéral (Vortek-TumorStent(Coloplast©,France), Urosoft-TumorStent(Bard-Angiomed©,Allemagne)) et une simple J (J-Fil(Rocamed©,Monaco)). Les EU étaient en polyuréthane, à l'exception de ImaJin Coloplast© en silicone. Pour toutes les EU, quatre parties de l'endoprothèse ont été spécifiquement analysées au microscope électronique à balayage à haute résolution (HR-SEM,FEI-XL40(Philips©,France)) : le corps de la sonde, l'orifice latéral, la boucle et la surface de marquage noire. Chaque expérience a été répétée à trois fois avec trois stents différents. L'analyse des EU comprenait la recherche d'imperfections définies comme des irrégularités>10µm. Résultats: Toutes les EU présentaient des imperfections sans différence notable. Les imperfections étaient principalement localisées sur la boucle de l'endoprothèse et sur l'orifice latéral. Pour les EU sans orifice latéral (J-Fil, Urosoft), des imperfections ont également été notées, sur les zones de section ainsi que sur l'orifice distal au niveau de la boucle. L'observation des surfaces de marquage ont révélé des imperfections sur l'Urosoft et de multiples imperfections sur l'Imajin et Stenostent. Triasoft présentait une surface plus lisse au niveau des zones de marquage en comparaison aux autres EU. Du matériel additionnel a été retrouvé sur les extrémités de la J-Fil et de ImaJin, mais toutes les EU présentaient des zones de section irrégulières au niveau des extrémités. CONCLUSION: Toutes les endoprothèses urétérales ne sont pas parfaitement lisses avant leur utilisation. Des imperfections ont été observées indépendamment de la composition ou de la forme de l'endoprothèse, et pourraient jouer un rôle dans le phénomène d'incrustation, en association avec les irrégularités internes, l'infection et la composition de l'urine. La fabrication et le type de matériau pourraient avoir un impact sur l'aspect lisse de la surface externe de l'endoprothèse.

2.
Andrology ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38588296

RESUMO

BACKGROUND: Phosphodiesterase 5 inhibitors (PDE5is) represent a first-line pharmacological therapy for erectile dysfunction (ED). Men could obtain PDE5is for recreational purposes without any proper medical prescription. OBJECTIVE: We aimed to analyze clinical characteristics of patients who already used any PDE5i for ED without previous formal medical prescription. MATERIALS AND METHODS: Data from 2012 heterosexual, sexually active men seeking first medical help for ED at our outpatient clinic between 2005 and 2022 were analyzed. All patients were assessed with a comprehensive sexual and medical history and completed the International Index of Erectile Function (IIEF) at baseline. Comorbidities were scored with the Charlson comorbidity index (CCI). Thereof, according to exposure to any PDE5i before their first visit, patients were subdivided into: PDE5i-naïve and non-PDE5i-naïve patients. Descriptive statistics tested the sociodemographic and clinical characteristics of both groups. A logistic regression model predicted the likelihood of being PDE5i-naïve at the baseline. Linear regression analysis (LRA) estimated the likelihood of being PDE5i-naïve versus non-PDE5i-naïve over the analyzed timeframe. Lastly, local polynomial regression models graphically explored the likelihood of being PDE5i-naïve at the first clinical assessment over the analyzed timeframe, and the sensitivity analyses tested the probability of being PDE5i-naïve at baseline. RESULTS: Overall, 1,491 (70.9%) patients were PDE5i-naïve and 611 (29.1%) were non-PDE5i-naïve at the first assessment. PDE5is-naïve patients were younger, with a lower prevalence of CCI ≥ 1 and of normal erectile function (EF) than non-PDE5i-naïve men (all p < 0.05). Multivariable logistic regression found that patients with lower BMI (OR: 0.99), higher IIEF-EF scores (OR: 1.02), lower rates of severe ED (OR: 0.94), and who had been assessed earlier throughout the study timeframe (OR: 1.27) were less likely to be PDE5i-naïve at baseline. Univariate LRA revealed that younger patients (Coeff: -0.02), with lower CCI (Coeff: -0.29) and higher alcohol intake per week (Coeff: 0.52) were more likely to be PDE5i-naïve over the analyzed timeframe. Moreover, for the same IIEF-EF score, patients with higher CCI had lower probability of being PDE5i-naïve. CONCLUSIONS: Self-prescription of PDE5is is an attitude presents in the general population, despite this phenomenon has decreased overtime. Current data outline the importance to keep promoting educational campaigns to promote PDE5is as effective and safe medicinal products, while avoiding their improper use.

3.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613608

RESUMO

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Humanos , Hólmio , Túlio , Ureteroscopia , Estudos Prospectivos , Cálculos Renais/cirurgia , Lasers
5.
World J Mens Health ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38449455

RESUMO

PURPOSE: We aimed to investigate the relationship between follicle stimulating hormone (FSH) and inhibin B (InhB). MATERIALS AND METHODS: Data from 1,230 consecutive men presenting for primary couple's infertility were analyzed. Health-significant comorbidities were scored with Charlson comorbidity index. Quartiles of FSH and InhB were considered to determine threshold values. Descriptive statistics and logistic regression models tested association between FSH and InhB values. RESULTS: Overall, 1,080 (87.8%) men had concordant FSH and InhB values. Conversely, 150 patients (12.2%) had discrepancies in FSH and InhB, with 78 (6.3%) and 72 (5.9%) men reporting both low and high FSH and InhB values, respectively. Infertile men with discordant values were younger (median [interquartile range] 38.0 years [34-41 years] vs. 36.0 years [31-40 years]); had smaller testicular volume (TV) (12 mL [10-15 mL] vs. 15 mL [12-20 mL]); and, had more frequently a sperm DNA fragmentation test >30% (179 [59.1%] vs. 40 [78.4%]) than those with concordant values (all p<0.05). Moreover, a higher frequency of previous cryptorchidism (27.3% vs. 11.9%), lower sperm concentration (3.0 million/mL [0.9-11.0 million/mL] vs. 13.8 million/mL [3.1-36.0 million/mL]), lower progressive sperm motility rates (12.0% [5.0%-25.3%] vs. 20.0% [7.0%-36.0%]), and greater rates of non-obstructive azoospermia (36.4% vs. 23.9%) were found in men with discordant FSH and InhB values (all p≤0.005). At multivariable logistic regression analysis, higher body mass index (odds ratio [OR], 1.08; p=0.001), smaller TV (OR, 0.91; p<0.001), and a history of cryptorchidism (OR, 2.49; p<0.001) were associated with discordant FSH and InhB values. CONCLUSIONS: More than one out of ten infertile men had discordant FSH and InhB values in the real-life setting showing worse clinical profiles than those with concordant levels. Smaller TV and history of cryptorchidism could be used as clinical markers to better tailor the need to test InhB.

6.
World J Urol ; 42(1): 145, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478094

RESUMO

INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Túlio/uso terapêutico , Litotripsia a Laser/métodos , Cálculos Renais/cirurgia
7.
Urology ; 185: 73-79, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38281669

RESUMO

OBJECTIVE: To present the patient-reported quality of life (QoL) outcomes from a prospective, randomized controlled trial comparing the use of pelvic floor muscle training (PFMT) and duloxetine after robot-assisted radical prostatectomy (RARP). METHODS: We identified 213 men with organ-confined disease having post-RARP urinary incontinence who were randomly assigned to received PFMT, duloxetine, combined PFMT-duloxetine and pelvic floor muscle home exercises. Urinary symptoms burden was measured by marked clinical important difference improvement (MCID) defined by using the International Prostate Symptom Score (IPSS) difference of - 8 points (ΔIPSS ≤-8). QoL was assessed according to Visual Analog Scale (VAS), King's Health Questionnaire (KQH), and International Index of Erectile Function (IIEF-5). Multivariable regression analyses aimed to predict MCID, burden of urinary symptoms (IPSS ≥8), and patients reporting to be satisfied (IPSS QoL ≤2) or comfortable (VAS ≤1) post-RARP. RESULTS: Moderate to severe urinary symptoms decreased from 48% preoperatively to 40%, 34%, and 23% at 3, 6, and 12months post-RARP. After surgery, MCID improvement was observed in 19% of patients, and deterioration in 3.3%. Large prostate was the only factor associated to MCID (OR 1.03 [95%CI 1.01-1.05], P = .005). At 6months, patients reached the same degree of preoperative satisfaction. Neurovascular bundle preservation was the only predictor of being comfortable regarding urinary symptoms postoperatively (OR 12.8 [CI95% 1.47-111.7], P = .02 at 3months) and was also associated to higher median postoperative IIEF-5. CONCLUSION: Despite urinary incontinence following RARP, patients with larger prostates experience a reduction of lower urinary tract symptoms within a year, which subsequently elevates QoL. Furthermore, nerve-sparing surgery augments erectile function and urinary outcomes, shaping postoperative QoL.


Assuntos
Disfunção Erétil , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Incontinência Urinária , Masculino , Humanos , Próstata , Qualidade de Vida , Estudos Prospectivos , Cloridrato de Duloxetina , Disfunção Erétil/cirurgia , Resultado do Tratamento , Prostatectomia , Neoplasias da Próstata/cirurgia
8.
World J Urol ; 42(1): 57, 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38280001

RESUMO

INTRODUCTION: Both Holmium:yttrium-aluminium-garnet (Ho:YAG) laser and Thulium Fiber Laser (TFL) can effectively treat all urinary stone types. This in vitro study evaluated the ablation volume per pulse (AVP) and required energy needed to ablate 1mm3 (RE, J/mm3) of various stone types at different laser settings with TFL. METHODS: 272-µm core-diameter laser fibers (Boston Scientific©) were connected to a 50 Watts TFL generator (IPG®). An experimental setup immerged human stones of calcium oxalate monohydrate (COM), uric acid (UA), and cystine (CYS) with a single pulse lasing emission (0.5/0.8/1 J), in contact mode. Stones were dried out before three-dimensional scanning to measure AVP and deduce from the pulse energy (PE) and AVP the RE. A direct comparison with known Ho:YAG's AVP and RE was then carried out. RESULTS: AVP for COM stones was significantly greater than those for CYS stones and similar to UA stones (p = 0.02 and p = 0.06, respectively). If AVP increased with PE against COM and UA stones, AVP decreased against CYS stones. 1 J PE resulted in a threefold lower RE compared with other PE for COM stones. On the contrary, RE for CYS increased with PE, whereas PE did not had influence on RE for UA. TFL was associated with greater AVP for COM, but lower for UA and CYS stones compared to Ho:YAG laser. CONCLUSION: This in vitro study firstly describes the ablation volume per pulse and required energy to treat a cubic millimeter of three frequent human stone types, and suggest TFL could not be suited for cystine. Therefore, stone composition could be considered when choosing the laser source for lithotripsy.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Litotripsia a Laser , Nefrolitíase , Cálculos Urinários , Humanos , Litotripsia a Laser/métodos , Túlio , Cistina , Cálculos Urinários/cirurgia , Lasers de Estado Sólido/uso terapêutico , Hólmio
10.
World J Mens Health ; 42(2): 384-393, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37635336

RESUMO

PURPOSE: To assess the relationship between clinical and semen characteristics and assisted reproductive technology (ART) outcomes with different birth weight (BW) categories in a cohort of infertile men. MATERIALS AND METHODS: Data from 1,063 infertile men were analyzed. Patients with BW ≤2,500, 2,500-4,000, and ≥4,000 g were considered as having low BW (LBW), normal BW (NBW), and high BW (HBW), respectively. Testicular volume (TV) was assessed with a Prader orchidometer. Serum hormones were measured in all cases. Semen analyses were categorized based on 2021 World Health Organization reference criteria. Sperm DNA fragmentation (SDF) was tested in every patient and considered pathological for SDF >30%. ART outcomes were available for 282 (26.5%) patients. Descriptive statistics and logistic regression analyses detailed the association between semen parameters and clinical characteristics and the defined BW categories. RESULTS: Of all, LBW, NBW, and HBW categories were found in 79 (7.5%), 807 (76.0%), and 177 (16.5%) men, respectively. LBW men had smaller TV, presented higher follicle-stimulating hormone (FSH) but lower total testosterone levels compared to other groups (all p<0.01). Sperm progressive motility (p=0.01) and normal morphology (p<0.01) were lower and SDF values were higher (all p<0.01) in LBW compared to other groups. ART pregnancy outcomes were lower in LBW compared to both NBW and HBW categories (26.1% vs. 34.5% vs. 34.5%, p=0.01). At multivariable logistic regression analysis, LBW was associated with SDF >30% (odd ratio [OR] 3.7; p<0.001), after accounting for age, Charlson Comorbidity Index (CCI), FSH, and TV. Similarly, LBW (OR 2.2; p<0.001), SDF >30% (OR 2.9; p<0.001) and partner's age (OR 1.3; p=0.001) were associated with negative ART outcomes, after accounting for the same predictors. CONCLUSIONS: LBW was associated with impaired clinical and semen characteristics in infertile men compared to both NBW and HBW. SDF and ART outcomes were significantly worse in the LBW group.

11.
Prostate ; 84(2): 158-165, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37904330

RESUMO

BACKGROUND: Urinary incontinence (UI) can negatively impact quality of life (QoL) after robot-assisted radical prostatectomy (RARP). Pelvic floor muscle training (PFMT) and duloxetine are used to manage post-RARP UI, but their efficacy remains uncertain. We aimed to investigate the efficacy of PFMT and duloxetine in promoting urinary continence recovery (UCR) after RARP. METHODS: A randomized controlled trial involving patients with urine leakage after RARP from May 2015 to February 2018. Patients were randomized into 1 of 4 arms: (1) PFMT-biofeedback, (2) duloxetine, (3) combined PFMT-biofeedback and duloxetine, (4) control arm. PFMT consisted of pelvic muscle exercises conducted with electromyographic feedback weekly, for 3 months. Oral duloxetine was administered at bedtime for 3 months. The primary outcome was prevalence of continence at 6 months, defined as using ≤1 security pad. Urinary symptoms and QoL were assessed by using a visual analogue scale, and validated questionnaires. RESULTS: From the 240 patients included in the trial, 89% of patients completed 1 year of follow-up. Treatment compliance was observed in 88% (92/105) of patients receiving duloxetine, and in 97% (104/107) of patients scheduled to PFMT-biofeedback sessions. In the control group 96% of patients had achieved continence at 6 months, compared with 90% (p = 0.3) in the PMFT-biofeedback, 73% (p = 0.008) in the duloxetine, and 69% (p = 0.003) in the combined treatment arm. At 6 months, QoL was classified as uncomfortable or worse in 17% of patients in the control group, compared with 44% (p = 0.01), 45% (p = 0.008), and 34% (p = 0.07), respectively. Complete preservation of neurovascular bundles (NVB) (OR: 2.95; p = 0.048) was the only perioperative intervention found to improve early UCR. CONCLUSIONS: PFMT-biofeedback and duloxetine demonstrated limited impact in improving UCR after RP. Diligent NVB preservation, along with preoperative patient and disease characteristics, are the primary determinants for early UCR.


Assuntos
Qualidade de Vida , Incontinência Urinária , Masculino , Humanos , Cloridrato de Duloxetina/uso terapêutico , Diafragma da Pelve , Resultado do Tratamento , Incontinência Urinária/etiologia , Incontinência Urinária/terapia , Prostatectomia/efeitos adversos
12.
J Sex Med ; 21(1): 54-58, 2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-37973410

RESUMO

BACKGROUND: Despite the existence of conservative therapies for Peyronie's disease (PD), surgery is commonly utilized for the treatment of bothersome curvatures due to its potential effectiveness, although it carries intrinsic risks and may not universally lead to satisfactory outcomes. AIM: To explore the rate and factors influencing patients' willingness to undergo surgery for PD. METHODS: Data were prospectively collected in 5 European academic centers between 2016 and 2020. Data included age, time from PD onset, penile pain, curvature degree, difficulty at penetration, hourglass deformity, erectile dysfunction (ED), and previous treatments. All patients were offered conservative treatments, either medications or injections. Tunical shortening or lengthening procedures were offered as an alternative to conservative treatments, when indicated. Penile prosthesis was offered to those with concomitant ED. Patients' attitudes with surgery were recorded. Logistic regression analyses tested the profile of patients who were more likely to be willing to undergo surgery. OUTCOMES: Patients' willingness to undergo surgery for PD. RESULTS: This study included 343 patients with a median age of 57.3 years (IQR, 49.8-63.6) and a median penile curvature of 40.0° (IQR, 30.0°-65.0°). Overall, 161 (47%) experienced penetration difficulties and 134 (39%) reported ED. Additionally, hourglass deformity and penile shortening were reported by 48 (14%) and 157 (46%), respectively. As for previous treatments, 128 (37%) received tadalafil once daily; 54 (16%) and 44 (13%), intraplaque verapamil and collagenase injections; and 30 (9%), low-intensity shock wave therapy. Significant curvature reduction (≥20°) was observed in 69 (20%) cases. Only 126 (37%) patients were open to surgery for PD when suggested. At logistic regression analysis after adjusting for confounders, younger age (odds ratio [OR], 0.97; 95% CI, 0.95-1.00; P = .02), more severe curvatures (OR, 1.04; 95% CI, 1.03-1.06; P < .0001), and difficulty in penetration (OR, 1.88; 95% CI, 1.04-3.41; P = .03) were associated with a greater attitude to consider surgical treatment. CLINICAL IMPLICATIONS: The need for effective nonsurgical treatments for PD is crucial, as is comprehensive patient counseling regarding surgical risks and benefits, particularly to younger males with severe curvatures. STRENGTHS AND LIMITATIONS: Main limitations are the cross-sectional design and the potential neglect of confounding factors. CONCLUSIONS: Patients with PD, having a lower inclination toward surgery, emphasize the need for effective nonsurgical alternatives and accurate counseling on the risks and benefits of PD surgery, particularly for younger men with severe curvatures.


Assuntos
Disfunção Erétil , Implante Peniano , Induração Peniana , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Transversais , Pênis/cirurgia , Resultado do Tratamento , Disfunção Erétil/cirurgia , Disfunção Erétil/complicações
13.
World J Urol ; 41(12): 3437-3447, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37932561

RESUMO

PURPOSE: To provide a technological description of the new pulsed solid-state Thulium:YAG laser (Tm:YAG). In addition, current available literature on Tm:YAG lithotripsy is also reviewed. MATERIALS AND METHODS: Medline, Scopus, Embase, and Web of Science databases were used to search for Tm:YAG operating mode articles. RESULTS: Tm:YAG technology works with a laser cavity with thulium-doped YAG crystal, pumped by laser diodes. Laser beam operates at 2013 nm, with an adjustable peak power (≥ 1000 W) and the minimal fiber laser diameter is of 200 µm. It has an intermediate water absorption coefficient and peak power-pulse duration. Various pulse modulations are proposed, aiming to minimize stone retropulsion. Multiple comparative in vitro studies suggest that Tm:YAG's ability to fragment stones is similar to the one of the Ho:YAG laser; on the contrary, its ability to dust all stone types is similar to the one of the TFL, with a low retropulsion. A single in vivo study assessed Tm:YAG lithotripsy feasibility. CONCLUSIONS: The new pulsed solid-state thulium:YAG laser could represent a safe and effective compromise between Ho:YAG laser and TFL for endoscopic lithotripsy, either in retrograde intra-renal surgeries or in percutaneous nephrolithotomy.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Hólmio
14.
World J Urol ; 41(12): 3765-3771, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37833547

RESUMO

BACKGROUND AND OBJECTIVE: We aimed to evaluate the concordance between the pre-settings ranges of thulium fibre laser (TFL) (Coloplast TFL Drive, Denmark) with easy-to-use graphical user interface and the laser settings used by a high-volume endo-urologist during surgical procedures. MATERIALS AND METHODS: In October 2022, we prospectively collected data of 67 patients who underwent TFL Drive (Coloplast, Denmark) for the management of urinary stones. Urothelial tumour (upper tract urinary cancer (UTUC) and bladder) 200 and 150 µm laser fibres were used for procedures. Stones characteristics (size and density) tumours and stenosis localizations, laser-on time (LOT), and laser settings were recorded. We also assessed the ablation speed (mm3/s), laser power (W), and Joules/mm3 values for each lithotripsy. RESULTS: A total 67 patients took part in the study. Median age was 52 (15-81) years. 55 (82%), 8 (12%), and 4 (6%) patients presented urinary stones, urothelial tumour, and stenosis, respectively. Median stone volume was 438 (36-6027) mm3 and median density was 988 (376-2000) HU. Median pulse energy was 0.6 (0.3-1.2), 0.8 (0.5-1) and 1 J for urinary stones, urothelial tumour and stenosis respectably. Endoscopically stone-free rate was 89%. Graphical user interface and surgeon accordance with the safety range were observed in 93.2%, 100% and 100% for urinary stones, UTUC and stenosis, respectively. CONCLUSION: During endoscopic procedures for urinary stones treatment, it is frequently needed to change laser parameters. These new TFL and GUI technology parameters remained in the pre-set security range in 94.1% of procedures.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Neoplasias , Cálculos Urinários , Humanos , Pessoa de Meia-Idade , Túlio , Litotripsia a Laser/métodos , Constrição Patológica , Cálculos Urinários/cirurgia , Lasers de Estado Sólido/uso terapêutico
15.
Artigo em Inglês | MEDLINE | ID: mdl-37906131

RESUMO

BACKGROUND: The aim of this study was to evaluate thulium fiber laser (TFL) safety and efficacy compared to high-power (HP) Holmium:YAG laser in pediatric patients who have undergone retrograde intrarenal surgery (RIRS) for kidney stones. METHODS: We retrospectively reviewed data from pediatric patients who underwent RIRS for kidney stones between 2018 and 2020. Complications were assessed 4-6 weeks postoperatively. Stone-free (SF) was defined as the absence of visible fragments or as the presence of a single residual fragment ≤2 mm at 3 months postoperative imaging. Student's t-test for continuous variables, and χ2 and Fisher's Exact Test for categorical variables were used to compare outcomes between patients treated with HP Holmium:YAG (group 1) and TFL (group 2). Univariate (UVA) and multivariate (MVA) logistic regression analyses were performed to predict SF-associated factors. RESULTS: Data from 126 pediatric patients were analyzed, 97 in group 1 and 29 in group 2. Preoperative characteristics were similar between cohorts. No major complication occurred in both groups. Group 2 had a shorter operative time (mean time 49.5 vs. 64.3 min, P=0.024). SF rate was 81.4% and 89.7% (P=0.45) and reintervention rate was 14.4% and 6.89% (P=0.046) in group 1 and 2, respectively. At UVA and MVA, the type of laser did not influence SF rate. However, prestenting and single stones were positively associated with SR rate. CONCLUSIONS: Both laser technologies are safe and effective and showed similar SF rates. TFL showed less operative time and lower re-intervention rate compared to HP Holmium:YAG. Further prospective studies are needed to corroborate our findings.

16.
J Clin Med ; 12(17)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37685776

RESUMO

Flexible ureteroscopy (fURS) with laser lithotripsy is currently the gold standard surgical treatment for ureteral and kidney stones with a maximum diameter of 2 cm [...].

17.
J Clin Med ; 12(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37568309

RESUMO

INTRODUCTION: Thulium lasers (TLs), namely the Thulium fiber laser (TFL) and the Thulium:YAG (Tm:YAG), are being increasingly adopted for the conservative treatment of upper urinary tract urothelial carcinoma (UTUC). However, to date, the real clinical impact of TLs on UTUC management remains not well-characterized. We performed a review of the literature to summarize the current evidence on TLs for UTUC treatment. MATERIALS AND METHODS: We performed a systematic review in January 2023 using the Embase and Medline online databases, according to the PRISMA recommendations and using the PICO criteria. Outcomes of interest were: (i) to assess the safety and feasibility of TLs in the treatment of UTUC, and (ii) to evaluate the oncological outcomes in terms of tumor recurrence and conservative treatment failure. Moreover, we described TL characteristics and its interaction with soft tissue. RESULTS: a total of 458 articles were screened, and six full texts including 273 patients were identified. All the included studies were retrospective series. Mean patient age ranged from 66 to 73 years. The indication of a conservative treatment was elective and imperative in 21.7-85% and 15-76% of cases, respectively. Laser power settings varied from 5 to 50 W. No intraoperative complications were reported, and all the procedures were successfully performed. The tumor recurrence rate was 17.7-44%, and the indication to radical nephroureterectomy was 3.7-44% during a follow-up of 6-50 months. Most of the postoperative complications were mild and transient, and ureteral strictures were reported in two studies. Major limitations were the retrospective nature of the studies, the small sample sizes, and the short follow-up. CONCLUSIONS: TL is an effective and safe technology for endoscopic UTUC treatment. However, current available literature lacks prospective and multicentric studies with large population sizes and long-term follow-up.

18.
World J Urol ; 41(8): 2119-2125, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37414942

RESUMO

INTRODUCTION: Holmium:yttrium-aluminium-garnet (Ho:YAG) and thulium fiber (TFL) lasers are currently the two laser sources recommended for endocorporeal laser lithotripsy (ELL). Recently, the pulsed-thulium:YAG (Tm:YAG) laser was also proposed for ELL, as an answer to both Ho:YAG and TFL limitations. We aimed to evaluate the efficiency, safety, and laser settings of Tm:YAG laser in ELL during retrograde intrarenal surgery (RIRS). METHODS: A prospective study of the first 25 patients with ureteral and renal stones who underwent RIRS using the Thulio (pulsed-Tm:YAG, Dornier©, Germany) was performed in a single center. 272 µm laser fibers were used. Stone size, stone density, laser-on time (LOT) and laser settings were recorded. We also assessed the ablation speed (mm3/s), Joules/mm3 and laser power (W) values for each procedure. Postoperative results, such as stone-free rate (SFR) and zero fragments rate (ZFR) were also recorded. RESULTS: A total of 25 patients were analyzed (Table 1). The median (IQR) age was 55 (44-72) years old. Median (IQR) stone volume was 2849 (916-9153)mm3. Median (IQR) stone density was 1000 (600-1174)HU. Median (IQR) pulse energy, pulse rate and total power were 0.6 (0.6-0,8)J, 15(15-20)Hz and 12(9-16)W, respectively. All procedures used "Captive Fragmenting" pulse modulation (Table 2). The median (IQR) J/mm3 was 14,8 (6-21). The median (IQR) ablation rate was 0,75 (0,46-2)mm3/s. One postoperative complications occurred (streinstrasse). SFR and ZFR were 95% and 55%, respectively. CONCLUSION: The pulsed-Tm:YAG laser is a safe and effective laser source for lithotripsy during RIRS, using low pulse energy and low pulse frequency.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Pessoa de Meia-Idade , Idoso , Lasers de Estado Sólido/uso terapêutico , Túlio/uso terapêutico , Estudos Prospectivos , Litotripsia a Laser/métodos , Cálculos Renais/cirurgia , Hólmio
19.
World J Urol ; 41(10): 2627-2636, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37468656

RESUMO

BACKGROUND: The management of urolithiasis has undergone significant advancements with the introduction of pulsed lasers, particularly the holmium:yttrium-aluminum-garnet (Ho:YAG) laser, which is currently considered the gold standard in endourology. However, the Ho:YAG laser has certain limitations, such as the inability to support small laser fibers (150 µm) and the requirement of a heavy water cooling system, making it challenging to transfer between operating rooms. These limitations have led to the emergence of new laser technologies, including the thulium fiber laser (TFL) and the thulium:yttrium-aluminum-garnet laser (Tm:YAG), as potential alternatives to the Ho:YAG laser. METHODS: In this review, we aimed to evaluate the effectiveness and safety of TFL, Ho:YAG, and Tm:YAG lasers in real-life scenarios by comparing clinical trial data with laboratory findings. A literature review was conducted, and relevant in vitro studies and clinical trials until March 2023 were analyzed. RESULTS: The findings indicate that TFL has demonstrated high ablation efficiency for stones of any composition, size, and location, superior the capabilities of Ho:YAG lasers. TFL has shown superior dusting and fragmentation abilities, lower retropulsion, and increased patient safety. The laser parameters, such as ablation efficiency, speed, operative time, dust quality, retropulsion, visibility, temperature safety, and stone-free rate, were compared between laboratory studies and clinical outcomes. CONCLUSION: Although the number of studies on TFL is limited, the available evidence suggests that TFL represents a significant advancement in laser technology for lithotripsy. However, further research is needed to fully explore the implications and limitations of TFL and Tm:YAG lasers.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Urolitíase , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio/uso terapêutico , Hólmio , Urolitíase/cirurgia
20.
Eur Urol Open Sci ; 52: 51-59, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37284041

RESUMO

Background: Bilateral kidney stones are commonly treated in staged procedures. Objective: To evaluate outcomes after same-sitting bilateral retrograde intrarenal surgery (SSB-RIRS) for renal stones. Design setting and participants: Data from adults who underwent bilateral RIRS in 21 centers were retrospectively reviewed (from January 2015 to June 2022). The inclusion criteria were unilateral/bilateral symptomatic bilateral stone(s) of any size/location in both kidneys and bilateral stones on follow-up with symptom/stone progression. Stone-free rate (SFR) was defined as absence of any fragment >3 mm at 3 mo. Outcome measurements and statistical analysis: Continuous variables are presented as medians and 25-75th percentiles. A multivariable logistic regression analysis was performed to evaluate independent predictors of sepsis and bilateral SFR. Results and limitations: A total of 1250 patients were included. The median age was 48.0 (36-61) yr. Of the patients, 58.2% were prestented. The median stone diameter was 10 mm on both sides. Multiple stones were present in 45.3% and 47.9% of the left and right kidneys, respectively. Surgery was stopped in 6.8% of cases. The median surgical time was 75.0 (55-90) min. Complications were transient fever (10.7%), fever/infection needing prolonged stay (5.5%), sepsis (2%), and blood transfusion (1.3%). Bilateral and unilateral SFRs were 73.0% and 17.4%, respectively. Female (odds ratio [OR] 2.97, 95% confidence interval [CI] 1.18-7.49, p = 0.02), no antibiotic prophylaxis (OR 5.99, 95% CI 2.28-15.73, p < 0.001), kidney anomalies (OR 5.91, 95% CI 1.96-17.94, p < 0.001), surgical time ≥100 min (OR 2.86, 95% CI 1.12-7.31, p = 0.03) were factors associated with sepsis. Female (OR 1.88, 95% CI 1.35-2.62, p < 0.001), bilateral prestenting (OR 2.16, 95% CI 1.16-7.66, p = 0.04), and the use of high-power holmium:YAG laser (OR 1.63, 95% CI 1.14-2.34, p < 0.01) and thulium fiber laser (OR 2.50, 95% CI 1.32-4.74, p < 0.01) were predictors of bilateral SFR. Limitations were retrospective study and no cost analysis. Conclusions: SSB-RIRS is an effective treatment with an acceptable complication rate in selected patients with kidney stones. Patient summary: In this large multicenter study, we looked at outcomes after same-sitting bilateral retrograde intrarenal surgery (SSB-RIRS) for renal stones in a large cohort. We found that SSB-RIRS was associated with acceptable morbidity and good stone clearance after a single session.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...