Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Periodontol ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710641

RESUMO

AIM: This retrospective cohort study aimed to volumetrically investigate the bone stability rate of prefabricated allogeneic bone blocks (PBB) and computer-aided design (CAD)/computer-aided manufacturing (CAM) custom-milled allogeneic bone blocks (CCBB) for ridge augmentation. MATERIALS AND METHODS: Nineteen patients were treated with 20 allografts: 11 CCBB, 9 PBB; 10 in the maxilla and 10 in the mandible. Clinical treatment history and cone beam computed tomography scans before surgery (t0), directly after graft surgery (t1) and after 6 months of healing prior to implant insertion (t2) were evaluated using a three-dimensional evaluation software for absolute bone volume, stability as well as vertical and horizontal bone gain. Furthermore, the inserted implants were analysed for survival, marginal bone loss (MBL) and complications for a mean follow-up period of 43.75 (±33.94) months. RESULTS: A mean absolute volume of 2228.1 mm3 (±1205) was grafted at t1. The bone stability rate was 87.6% (±9.9) for CCBB and 83.0% (±14.5) for PBB. The stability was higher in the maxilla (91.6%) than in the mandible (79.53%). Surgery time of PBB was longer than for CCBB (mean Δ = 52 min). The survival rate of the inserted implants was 100% with a mean MBL of 0.41 mm (±0.37). CONCLUSION: The clinical performance of both allograft block designs was equally satisfactory for vertical and horizontal bone grafting prior to implant placement. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov: NCT06027710.

2.
Oral Health Prev Dent ; 18(1): 77-84, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32051974

RESUMO

PURPOSE: The aim of this study was to evaluate the association between periodontitis and preterm birth in a Spanish Caucasian population, based on clinical and biochemical outcomes. Epidemiological studies have suggested that periodontitis is a potential risk factor for preterm birth. However, other studies have shown high heterogeneity in their results. Some factors such as number of evaluations during pregnancy, sample size, study population and maternal age may have an impact on the variability of the result. METHODS AND MATERIALS: This cohort study enrolled 158 pregnant women, 39 with periodontitis and 119 without periodontitis. All pregnant women were evaluated in the first, second and third trimester. RESULTS: Statistically significant differences were found in periodontal parameters between both groups, but no statistically significant differences were found in biochemical parameters during pregnancy. The duration of pregnancy in healthy patients was 38.78 ± 4.49 weeks, and in patients with periodontitis 37.81 ± 4.89 weeks, with no statistical difference (p > 0.05). This showed that periodontitis was not associated with preterm birth in a Spanish Caucasian cohort. CONCLUSION: In this study, periodontitis stage II, grade B, was not statistically associated with preterm birth. Pregnancy is a short period of time in order to evaluate long-term oral systemic infections. Adverse pregnancy outcomes are more difficult to occur. Thus, since pregnancy timing average cannot be changed, the stages of periodontal disease (initial, moderate, advanced) could be another factor to study.


Assuntos
Periodontite , Nascimento Prematuro , Estudos de Coortes , Feminino , Humanos , Recém-Nascido de Baixo Peso , Recém-Nascido , Gravidez , Resultado da Gravidez , Fatores de Risco
3.
Clin Oral Implants Res ; 30(7): 595-602, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31021469

RESUMO

OBJECTIVES: The aim of this RCT was to assess radiographically the effect of abutment height and depth of placement of platform-switched implants on interproximal peri-implant bone loss (IPBL) in patients with thin peri-implant mucosa. MATERIAL AND METHODS: Thirty-three patients received one prosthesis supported by two implants replacing at least two adjacent missing teeth (66 implants). Patients were randomly allocated and implant insertion depth adapted to abutment height groups (3 mm height group the implants were placed 2 mm subcrestally; 1 mm height group, equicrestally). Clinical and radiological measurements were performed at 3, 6 and 12 months after surgery. Interproximal bone-level changes were compared between treatment groups using repeated measures mixed ANOVA. The association between IPBL and categorical variables was also analyzed. RESULTS: The mean IPBL in 1 mm abutment group was 0.76 ± 0.79 mm at 3 months, 0.92 ± 0.88 mm at 6 months, and 0.95 ± 0.88 mm at 12 months, while in the 3 mm abutment group was 0.06 ± 0.21, 0.07 ± 0.22 mm, and 0.12 ± 0.33 mm, respectively. Significant differences between both groups were observed at every time point. When the influence of patient characteristics and clinical variables was analyzed, no statistically significant differences were also observed. CONCLUSIONS: The use of long abutments, in combination with subcrestal implant position in sites with thin mucosa, led to lower IPBL in comparison with the use of short abutments.


Assuntos
Perda do Osso Alveolar , Implantação Dentária Endóssea , Dente Suporte , Projeto do Implante Dentário-Pivô , Humanos , Mucosa , Próteses e Implantes
4.
Clin Oral Implants Res ; 29(1): 108-117, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29222809

RESUMO

OBJECTIVE: The aim of this randomized clinical trial was to compare the effect on the interproximal implant bone loss (IBL) of two different heights (1 and 3 mm) of definitive abutments placed at bone level implants with a platform switched design. MATERIAL AND METHODS: Twenty-two patients received forty-four implants (6.5-10 mm length and 3.5-4 mm diameter) to replace at least two adjacent missing teeth, one bridge set to each patient-two implants per bridge. Patients were randomly allocated, and two different abutment heights, 1 and 3 mm using only one abutment height per bridge, were used. Clinical and radiological measurements were performed at 3 and 6 months after surgery. Interproximal bone level changes were compared between treatment groups. The association between IBL and categorical variables (history of periodontitis, smoking, implant location, implant diameter, implant length, insertion torque, width of keratinized mucosa, bone density, gingival biotype and antagonist) was also performed. RESULTS: At 3 months, implants with a 1-mm abutment had significantly greater IBL (0.83 ± 0.19 mm) compared to implants with a 3-mm abutment (0.14 ± 0.08 mm). At 6 months, a greater IBL was observed at implants with 1-mm abutments compared to implants with 3-mm abutments (0.91 ± 0.19 vs. 0.11 ± 0.09 mm). The analysis of the relation between patient characteristics and clinical variables with IBL revealed no significant differences at any moment except for smoking. CONCLUSIONS: Abutment height is an important factor to maintain interproximal implant bone level in early healing. Short abutments led to a greater interproximal bone loss in comparison with long abutments after 6 months. Other variables except smoking showed no relation with interproximal bone loss in early healing.


Assuntos
Perda do Osso Alveolar , Dente Suporte , Projeto do Implante Dentário-Pivô , Implantação Dentária Endóssea , Perda do Osso Alveolar/diagnóstico por imagem , Análise de Variância , Prótese Dentária Fixada por Implante , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Periodontite , Radiografia Dentária , Cicatrização
5.
Artigo em Inglês | MEDLINE | ID: mdl-28817138

RESUMO

In this 3-year follow-up study, peri-implant bone loss at bone-level implants was evaluated with two definitive abutment heights: 1 mm and 2.5 mm. Peri-implant bone loss was defined as the distance between the implant shoulder and the first bone-to-implant contact from the time of loading to the 36-month follow-up, estimated using periapical radiographs. The bone loss was increased at the time of follow-up, to 1.30 mm (95% confidence interval [CI]: 0.70-1.89 mm; SD = 1.89) and 0.33 mm (95% CI: 0.11-0.55; SD = 0.59) at 36 months in short and long abutments, respectively. Placement of short abutments induced higher peri-implant bone loss at bone-level implants during a peri-implant recall program.


Assuntos
Processo Alveolar/patologia , Dente Suporte , Projeto do Implante Dentário-Pivô/métodos , Adulto , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/patologia , Perda do Osso Alveolar/prevenção & controle , Processo Alveolar/cirurgia , Projeto do Implante Dentário-Pivô/efeitos adversos , Seguimentos , Humanos , Radiografia Dentária , Estudos Retrospectivos
6.
Clin Oral Implants Res ; 27(10): 1221-1226, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27699885

RESUMO

OBJECTIVE: The aim of this study was to evaluate the soft tissue histomorphometric composition around implant abutments comparing two different materials, titanium (Ti) and zirconia (ZrO2 ). MATERIAL AND METHODS: Twelve implants were placed at bone level in the mandible of six beagle dogs (one in each side). At the same day of surgery one titanium abutment was screwed to the implant in one side (control group) and a zirconia abutment was screwed in the contralateral side. Nine months after implant/abutments placement, animals were sacrificed for histological analysis. Descriptive analysis was calculated for each variable and Wilcoxon test was applied to evaluate histomorphometric variables. RESULTS: At the end of the study the soft tissue dimension at Ti and ZrO2 were similar in all counterparts: biological width, the length of the barrier epithelium, length of the connective tissue, and the percentage of collagen fibers density. However, the percentage of blood vessels was higher for the Ti in comparison to ZrO2 (5.11% ± 1.70 and 2.23% ± 0.98, respectively [P = 0.016]). CONCLUSIONS: Peri-implant soft tissue histomorphology composition was similar in implant abutments made of ZrO2 and titanium after 9 months of healing.


Assuntos
Dente Suporte , Implantes Dentários , Materiais Dentários/farmacologia , Gengiva/efeitos dos fármacos , Titânio/farmacologia , Zircônio/farmacologia , Animais , Implantação Dentária Endóssea , Implantes Dentários/microbiologia , Cães , Gengiva/anatomia & histologia , Mandíbula , Modelos Animais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...