1.
J Card Fail ; 29(4): 463-472, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36243338

RESUMO

BACKGROUND: Congestion is central to the pathophysiology of heart failure (HF); thus, tracking congestion is crucial for the management of patients with HF. In this study we aimed to compare changes in inferior vena cava diameter (IVCD) with venous pressure following manipulation of volume status during ultrafiltration in patients with cardiac dysfunction. METHODS AND RESULTS: Patients with stable hemodialysis and with systolic or diastolic dysfunction were studied. Central venous pressure (CVP) and peripheral venous pressure (PVP) were measured before and after hemodialysis. IVCD and PVP were measured simultaneously just before dialysis, 3 times during dialysis and immediately after dialysis. Changes in IVCD and PVP were compared at each timepoint with ultrafiltration volumes. We analyzed 30 hemodialysis sessions from 20 patients. PVP was validated as a surrogate for CVP. Mean ultrafiltration volume was 2102 ± 667 mL. IVCD discriminated better ultrafiltration volumes ≤ 500 mL or ≤ 750 mL than PVP (AUC 0.80 vs 0.62, and 0.80 vs 0.56, respectively; both P< 0.01). IVCD appeared to track better ultrafiltration volume (P< 0.01) and hemoconcentration (P< 0.05) than PVP. Changes in IVCD were of greater magnitude than those of PVP (average change from predialysis: -58 ± 30% vs -28 ± 21%; P< 0.001). CONCLUSIONS: In patients undergoing ultrafiltration, changes in IVCD tracked changes in volume status better than venous pressure.


Assuntos
Cardiopatias , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Veia Cava Inferior/diagnóstico por imagem , Pressão Venosa Central/fisiologia , Diálise Renal , Pressão Venosa
2.
Echocardiography ; 39(4): 637-642, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35277896

RESUMO

A 56-year-old patient with rheumatic heart disease and atrial fibrillation underwent mitral valve replacement with a mechanical prosthesis. The 3D perioperative echocardiogram showed an intermittent immobile medial disk without hemodynamic repercussion in the intensive care unit. The patient was taken back to the operating room and surgeons could not identify the cause. An enlarged left atrium and the size of the prosthetic valve was thought to have precipitated this condition. The heart team decided a biological prosthetic valve replacement would be performed. This case emphasizes the important role of the perioperative 3D echocardiogram in the detection of immediate surgical complications.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Cardiopatia Reumática , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/etiologia , Estenose da Valva Mitral/cirurgia , Cardiopatia Reumática/complicações , Cardiopatia Reumática/cirurgia