Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
iScience ; 27(7): 110220, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39036039

RESUMO

Increasing representation of people with disabilities in science and engineering will require systemic changes to the culture around support and accommodations. Equitable interview practices can help foster such changes. We, an interdisciplinary group of disabled and nondisabled early-career scientists who care deeply about making science more accessible to all, present a framework of suggestions based on Universal Design principles for improving the accessibility and equitability of interviews for people with disabilities and other underrepresented groups. We discuss potential challenges that may arise when implementing these suggestions and provide questions to guide discussions about addressing them.

3.
Science ; 381(6656): 384, 2023 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-37499024
5.
Am J Emerg Med ; 70: 151-156, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37307660

RESUMO

BACKGROUND: Accurate estimation of fluid status is important in the management of heart failure patients, however, the current methods for bedside assessment can be unreliable or impractical for daily use. METHODS: Non-ventilated patients were enrolled immediately prior to scheduled right heart catheterization (RHC). Using M-mode, IJV maximum (Dmax) and minimum (Dmin) anteroposterior diameters were measured during normal breathing, while supine. Respiratory variation in diameter (RVD) was calculated as [(Dmax - Dmin)/Dmax] in percentage. Collapsibility with sniff maneuver (COS) was assessed. Lastly, inferior vena cava (IVC) was assessed. Pulmonary artery pulsatility index (PAPi) was calculated. Data was obtained by five investigators. RESULTS: Total 176 patients were enrolled. Mean BMI was 30.5 kg/m2, LVEF 14-69% (range), 38% with LVEF ≤35%. The POCUS of IJV could be performed in all patients in <5 min. Increasing RAP demonstrated progressive increase in IJV and IVC diameters. For high filling pressure (RAP ≥10 mmHg), an IJV Dmax ≥1.2 cm or IJV-RVD < 30% had specificity >70%. Combining the POCUS of IJV to physical examination improved the combined specificity to 97% for RAP ≥10 mmHg. Conversely, a finding of IJV-COS was 88% specific for normal RAP (<10 mmHg). An IJV-RVD <15% is suggested as a cutoff for RAP ≥15 mmHg. The performance of IJV POCUS was comparable to IVC. For RV function assessment, IJV-RVD < 30% had 76% sensitivity and 73% specificity for PAPi <3, while IJV-COS was 80% specific for PAPi ≥3. CONCLUSION: POCUS of IJV is an easy to perform, specific and reliable method for volume status estimation in daily practice. An IJV-RVD < 30% is suggested for estimation of RAP ≥10 mmHg and PAPi <3.


Assuntos
Veias Jugulares , Função Ventricular Direita , Humanos , Veias Jugulares/diagnóstico por imagem , Ultrassonografia , Cateterismo Cardíaco , Veia Cava Inferior/diagnóstico por imagem
6.
Nat Rev Chem ; 7(2): 69-70, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37117910
9.
Nat Rev Mater ; 7(6): 421-423, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35502227

RESUMO

Many graduate students experience mental health struggles that lead them to question their place in academia. Two scientists who experienced extreme lows in graduate school reflect on what helped them during their low points, and suggest strategies for everyone to contribute to mentally healthier workplaces in academia.

14.
EBioMedicine ; 76: 103867, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35149284

RESUMO

BACKGROUND: Early and accurate determination of bacterial infections as a potential cause for a patient's systemic inflammatory response is required for timely administration of appropriate treatment and antibiotic stewardship. Procalcitonin (PCT) and C-reactive protein (CRP) have both been used as biomarkers to infer bacterial infections, particularly in the context of sepsis. There is an urgent need to develop a platform for simultaneous quantification of PCT and CRP, to enable the potential use of these biomarkers at the point-of-care. METHODS: A multiplexed lateral flow assay (LFA) and a fluorescence optical reader were developed. Assay performance was validated by testing spiked antigens in the buffer, followed by a validation study comparing results with conventional assays (Roche Cobas e411 Elecsys PCT and Siemens ADVIA XPT CRP) in 25 archived remnant human serum samples. FINDINGS: A linear regression correlation of 0·97 (P < 0·01) was observed for PCT, and a correlation of 0·95 (P < 0·01) was observed for CRP using direct patient samples. We also validated our platform's ability to accurately quantify high-dose CRP in the hook effect range where excess unlabeled analytes occupy binding sites at test lines. INTERPRETATION: A fluorescence reader-based duplex LFA for simultaneous quantification of PCT and CRP was developed and successfully validated with clinical samples. The rapid, portable, and low-cost nature of the platform offers potential for differentiation of bacterial and viral infections in emergency and low-resource settings at the point-of-care. FUNDING: NIH/NIBIB Award 1R01EB021331, and Academic Venture Fund from the Atkinson Center for a Sustainable Future at Cornell University.


Assuntos
Infecções Bacterianas , Sepse , Infecções Bacterianas/diagnóstico , Biomarcadores , Proteína C-Reativa/análise , Humanos , Pró-Calcitonina , Sepse/diagnóstico
16.
Anal Chem ; 93(36): 12175-12180, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34469115

RESUMO

Malaria and typhoid fever are two febrile illnesses prevalent in the tropics that often present overlapping symptoms. In this work, we demonstrate an optical reader-based diagnostics platform for rapid codetection and quantification of two antigen targets: lipopolysaccharide (LPS) for typhoid fever and plasmodium lactate dehydrogenase (pLDH) for malaria infections. We report a limit of detection (LoD) of 5 ng/mL for LPS and 10 ng/mL for pLDH in a spiked serum test. We also validated the duplex test's performance of differentiating malaria infection, typhoid fever infection, and coinfection by testing clinical samples in human serum. Our platform provides the potential for further multiplexing by encoding different color codes to various detection targets. The rapid result (∼15 min), low cost (∼$2), and minimal volume requirement for human serum clinical samples (4 µL) of our diagnostic platform offer great potential for deployment in resource-limited settings to help distinguish common causes for acute febrile illnesses at the point-of-need.


Assuntos
Malária , Plasmodium , Febre Tifoide , Humanos , L-Lactato Desidrogenase , Malária/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Febre Tifoide/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA