Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Materials (Basel) ; 15(23)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36499972

RESUMO

The addition of Superabsorbent Polymer (SAP) decreases the effect of autogenous shrinkage present in pastes, mortars, and concretes. In this study we investigated the influence of the addition of SAP in self-compacting cement paste mixtures. Eighteen 5 × 10 cylindrical specimens were molded in all, three for each mixture (CPII base, CPII 0.15%SAP/600µm, CPII 0.15%SAP/800 µm, CPV base, CPV 0.15%SAP/600 µm, CPV 0.15%SAP/800 µm). Two types of cement were tested, CP II-Z and CP V-ARI with 0.15% of weight replaced per two diameters of SAP (600 µm and 800 µm). The samples followed the standards required. Mini slump tests were carried out in the fresh state, and uniaxial compressive strength, elastic modulus, specific mass, absorption, and air content in the hardened state after 28 days. The results obtained show the SAP is high indicated to replaced cement in small % of weight i/to fresh and hardened paste. Likewise, the group mix n° 3 composed of CPII 0.15% of SAP with 800 µm diameter presented the best result.

2.
Materials (Basel) ; 15(22)2022 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-36431627

RESUMO

Background: The occurrence of bone fractures is increasing worldwide, mainly due to the health problems that follow the aging population. The use of additive manufacturing and electrical stimulators can be applied for bioactive achievements in bone healing. However, such technologies are difficult to be transferred to medical practice. This work aims to develop an orthosis with a combined magnetic field (CFM) electrostimulator that demonstrates concepts and design aspects that facilitate its use in a real scenario. Methods: A 3D-printed orthosis made of two meshes was manufactured using PLA for outer mechanical stabilization mesh and TPU for inner fixation mesh to avoid mobilization. A CFM stimulator of reduced dimension controlled by a mobile application was coupled onto the orthosis. The design concepts were evaluated by health professionals and their resistance to chemical agents commonly used in daily activities were tested. Their thermal, chemical and electrical properties were also characterized. Results: No degradation was observed after exposure to chemical agents. The CMF achieved proper intensity (20-40 µT). The thermal analysis indicated its appropriate use for being modelled during clinical assessment. Conclusion: An orthosis with a coupled electrostimulator that works with a combined magnetic field and is controlled by mobile application was developed, and it has advantageous characteristics when compared to traditional techniques for application in real medical environments.

3.
Curr Osteoporos Rep ; 18(6): 790-795, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33085001

RESUMO

PURPOSE OF REVIEW: New biomaterials for biomedical applications have been developed over the past few years. This work summarizes the current cell lines investigations regarding nanosurface modifications to improve biocompatibility and osseointegration. RECENT FINDINGS: Material surfaces presenting biomimetic morphology that provides nanoscale architectures have been shown to alter cell/biomaterial interactions. Topographical and biofunctional surface modifications present a positive effect between material and host response. Nanoscale surfaces on titanium have the potential to provide a successful interface for implantable biomedical devices. Future studies need to directly evaluate how the titanium nanoscale materials will perform in in vivo experiments. Biocompatibility should be determined to identify titanium nanoscale as an excellent option for implant procedures.


Assuntos
Materiais Biocompatíveis/química , Nanoestruturas/química , Osseointegração/fisiologia , Próteses e Implantes , Titânio/química , Animais , Linhagem Celular , Proliferação de Células , Humanos , Propriedades de Superfície
4.
Artif Organs ; 44(8): 877-882, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32320080

RESUMO

The polymer poly(ε-caprolactone) (PCL) has been used in the biomaterial field for its relatively inexpensive price and suitability for modification. Also, its chemical and biological properties are desirable for biomedical applications. The electrospinning process has been used for producing polymer fibers of PCL due in large part to an increased interest in nanoscale properties and technologies. Moreover, the use of biocompatible polymers for the viability of cell growth is a promising alternative to improve osseointegration. Characterization techniques such as scanning electron microscopy and contact angle were used for analyses of samples. Adult human dermal fibroblasts (neonatal) were utilized to evaluate the biocompatibility of the association of the electrospinning process of the biocompatible polymer (PCL) with TiO2 nanotubes on the Ti-30Ta alloy surface. The results of this study showed a favorable response for adhesion on the surface. This promising material is due to the modulation of the biological response.


Assuntos
Fibroblastos/efeitos dos fármacos , Nanofibras , Nanotubos , Tantálio , Titânio/farmacologia , Ligas , Materiais Biocompatíveis , Caproatos , Humanos , Lactonas , Teste de Materiais/métodos , Microscopia Eletrônica de Varredura , Polímeros , Pele/citologia , Pele/efeitos dos fármacos , Titânio/química
5.
J Biomed Mater Res A ; 102(7): 2147-56, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23893959

RESUMO

In this study, in vitro cytocompatibility was investigated in the Ti-30Ta alloy after two kinds of surfaces treatments: alkaline and biomimetic treatment. Each condition was evaluated by scanning electron microscopy/energy-dispersive X-ray spectroscopy. Cellular adhesion, viability, protein expression, morphology, and differentiation were evaluated with Bone marrow stromal cells (MSCs) to investigate the short and long-term cellular response by fluorescence microscope imaging and colorimetric assays techniques. Two treatments exhibited similar results with respect to total protein content and enzyme activity as compared with alloy without treatment. However, it was observed improved of the biomineralization, bone matrix formation, enzyme activity, and MSCs functionality after biomimetic treatment. These results indicate that the biomimetic surface treatment has a high potential for enhanced osseointegration.


Assuntos
Ligas , Células-Tronco Mesenquimais/citologia , Tantálio , Titânio , Animais , Microscopia Eletrônica de Varredura , Ratos , Ratos Wistar , Propriedades de Superfície
6.
Biomater Sci ; 1(3): 322-332, 2013 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-32481857

RESUMO

Material surfaces that provide biomimetic cues, such as nanoscale architectures, have been shown to alter cell/biomaterial interactions. Recent studies have identified titania nanotube arrays as strong candidates for use in interfaces on implantable devices due to their ability to elicit improved cellular functionality. However, limited information exists regarding the immune response of nanotube arrays. Thus, in this study, we have investigated the short- and long-term immune cell reaction of titania nanotube arrays. Whole blood lysate (containing leukocytes, thrombocytes and trace amounts of erythrocytes), isolated from human blood, were cultured on titania nanotube arrays and biomedical grade titanium (as a control) for 2 hours and 2 and 7 days. In order to determine the in vitro immune response on titania nanotube arrays, immune cell functionality was evaluated by cellular viability, adhesion, proliferation, morphology, cytokine/chemokine expression, with and without lipopolysaccharide (LPS), and nitric oxide release. The results presented in this study indicate a decrease in short- and long-term monocyte, macrophage and neutrophil functionality on titania nanotube arrays as compared to the control substrate. This work shows a reduced stimulation of the immune response on titania nanotube arrays, identifying this specific nanoarchitecture as a potentially optimal interface for implantable biomedical devices.

7.
Mater Sci Eng C Mater Biol Appl ; 32(7): 2060-2067, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34062696

RESUMO

In this study, the mechanical substrate and topographical surface properties of anodized Ti30Ta alloy were investigated using scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS) and contact angle measurement. The anodization process was performed in an electrolyte solution containing HF (48%) and H2SO4 (98%) in the volumetric ratios 1:9 with the addition of 5% dimethyl sulfoxide (DMSO) at 15V, 25V and 35V for 20 and 40min, producing a nanotube architecture when anodized at 35V for 40min. Human dermal fibroblasts (HDF, neonatal) were utilized to evaluate the biocompatibility of Ti30Ta nanotubes and Ti30Ta alloy after 1 and 3days of culture. Cellular adhesion, proliferation, viability, cytoskeletal organization and morphology were investigated using fluorescence microscope imaging, biochemical assay and SEM imaging respectively. The results presented identify altered material properties and improved cellular interaction on Ti30Ta nanotubes as compared to Ti30 Ta alloy.

8.
Rev. Assoc. Paul. Cir. Dent ; 50(3): 264-7, maio-jun. 1996. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-181087

RESUMO

Os pacientes desdentados totais, portadores ou näo de prótese total, säo, via de regra, considerados pelos profissionais como pacientes que já passaram por situaçöes diversas que os levaram a um estágio final, em que o único problema a ser solucionado é a confecçäo de uma prótese total. Säo muitos os trabalhos que contrariam essa idéia. Esses trabalhos provam a existência ou freqüência de raízes residuais, dentes inclusos, cistos etc., os quais obrigam o profissional a intervir em rebordos de maneira urgente devido à proporçäo de alteraçöes. Tais problemas poderiam ser evitados com a utilizaçäo de uma técnica radiográfica oclusal, antecedente ao tratamento protético (auxiliando no diagnóstico)


Assuntos
Boca Edêntula/diagnóstico , Boca Edêntula/reabilitação , Prótese Total/normas , Radiografia Dentária , Diagnóstico Bucal , Raiz Dentária/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA