Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Vasc Endovascular Surg ; 52(5): 335-343, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29576007

RESUMO

PURPOSE: To evaluate the variations in aortic diameters and long-term results in patients who underwent thoracic endovascular aortic repair (TEVAR) for acute blunt traumatic thoracic aortic injuries (BTTAIs). MATERIALS AND METHODS: We retrospectively evaluated 23 patients with a mean age of 39 years (range: 17-74 years) who underwent TEVAR for BTTAI between October 2000 and November 2014. All of the patients underwent computed tomography angiography (CTA) before hospital discharge as a baseline imaging for the subsequent follow-up examinations. The technical success, overall survival, and complications were evaluated. Furthermore, the aortic diameters outside of the stent-graft (1 cm proximal and 1 cm distal to the stent-graft) and the aortic diameters within the stent-graft (2 cm distal to the proximal end and 2 cm proximal to the distal end) were assessed. The diameters at baseline on CTA were compared with those of the latest available follow-up examination. RESULTS: Technical success was 100% with a mean follow-up of 65.4 months (range: 12-171 months). No death was registered, and 2 (8.7%) of 23 endograft-related complications (1 stent-graft distal infolding and 1 endoleak 2 and 4 months after the procedure, respectively) were observed. An increase in aortic diameter either proximal or distal to the stent-graft (mean value 0.7 and 0.5 mm, respectively) or within the stent-graft (mean value of 0.5 mm for both proximal and distal diameters) was registered (mean follow-up at 65.4 months, range: 12-171 months). CONCLUSION: Aortic dilatation following TEVAR for BTTAI is minimal during long-term follow-up. Endovascular treatment represents a durable and safe option in acute BTTAIs.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Traumatismos Torácicos/cirurgia , Lesões do Sistema Vascular/cirurgia , Ferimentos não Penetrantes/cirurgia , Adolescente , Adulto , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Dilatação Patológica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Stents , Traumatismos Torácicos/diagnóstico por imagem , Traumatismos Torácicos/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Remodelação Vascular , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/fisiopatologia , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/fisiopatologia , Adulto Jovem
2.
Vasc Endovascular Surg ; 52(1): 39-45, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29162027

RESUMO

BACKGROUND: To assess whether noncontrast-enhanced magnetic resonance imaging (NC-MRI) is an alternative to contrast-enhanced computed tomography angiography (CTA) for aortoiliac measurements before endovascular abdominal aortic aneurysm repair (EVAR). METHODS: This study encompasses 30 patients admitted for elective EVAR (27 men and 3 women). Two expert readers (vascular radiologist and vascular surgeon) reviewed CTA images in consensus and chose the proper endograft for each patient. Subsequently, a vascular radiologist and a resident radiologist (observer 1 and 2) reviewed CTA and NC-MRI examinations in a double-blind way and completed standard measurements. The interobserver and intermodality agreement was calculated by intraclass correlation coefficients (ICCs). Furthermore, the correlation between the endograft size chosen by the first pair and the second pair of observers was evaluated. RESULTS: Concerning all measurements, no significant difference was found. Both CTA and NC-MRI angiographic measurements showed strong correlation. Interobserver ICCs for CTA and NC-MRI showed ranges of 0.62 to 0.99 (mean: 0.92) and 0.56 to 0.99 (mean: 0.91); intermodality ICCs for observer 1 and 2 showed ranges of 0.64 to 0.99 (mean: 0.92) and 0.56 to 0.99 (mean: 0.92). The CTA and NC-MRI vascular measurements correlated strongly, except for both external iliac artery diameters. The choice of stent size was always the same between the 2 observers; furthermore, graft size was always in agreement with that selected prospectively. CONCLUSION: Computed tomography angiography remains the standard of reference for EVAR planning; NC-MRI can be an option for patients with contraindications for CTA, in particular those with renal impairment.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares , Iohexol/análogos & derivados , Angiografia por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Iohexol/administração & dosagem , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Stents
3.
Interv Neuroradiol ; 21(3): 325-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26015524

RESUMO

This paper is a case report of a young patient after a major head trauma causing multiple skull base fractures. The trauma occasioned pseudoaneurysm (PSA) from intracavernous C4 segment of left internal carotid artery (ICA) protruding in the sphenoidal sinus. After two months, two episodes of massive epistaxis occurred. Consequently, the post-traumatic PSA was treated, after carotid occlusion test, with flow-diverter stent positioning. A computed tomography angiography study performed in the following days showed complete resolution of the post-traumatic PSA lesion and ICA patency.


Assuntos
Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Lesões das Artérias Carótidas/etiologia , Lesões das Artérias Carótidas/terapia , Artéria Carótida Interna , Procedimentos Endovasculares/métodos , Epistaxe/etiologia , Epistaxe/terapia , Fraturas Cranianas/complicações , Stents , Falso Aneurisma/diagnóstico por imagem , Angiografia Digital , Lesões das Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Angiografia Cerebral , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Fraturas Cranianas/diagnóstico por imagem , Adulto Jovem
4.
Rev. bras. cir. plást ; 26(3): 379-384, July-Sept. 2011. ilus
Artigo em Inglês, Português | LILACS | ID: lil-608192

RESUMO

INTRODUCTION: Fetal calf serum (FCS) is commonly used as a supplement in the culture medium for fibroblast cells. This supplementation is far from ideal as sample quality varies from batch to batch and the composition of FCS is not completely known. In addition, FCS may be contaminated with viruses and/or prions and may also cause adverse immunologic responses in humans. Due to these facts, a worldwide effort is being made to find alternatives for xenobiotic elements in cell cultures. Human serum could be a safer alternative, especially for clinical application. METHODS: We investigated human serum as a substitute for FCS in human fibroblast culture. Fresh human serum was obtained from 10 healthy volunteers. Fibroblasts were cultivated in multiwell plates containing either Dulbecco's modified Eagle's medium (DMEM) plus 10 percent FCS (D10) or DMEM plus 10 percent human serum (D10H). Cell counts were obtained between 24 and 264 hours of cultivation; results were expressed as the mean number of cells ± standard error of the mean to create cell proliferation curves. RESULTS: There was no statistical difference in fibroblast proliferation between the two groups. Human serum supported human fibroblast growth and proliferation, suggesting that it may be a potential substitute for FCS in human cell culture. Cells cultivated with human serum presented a different morphology, appearing smaller and more rounded as compared to cells cultivated in D10. CONCLUSIONS: These results demonstrate that human serum can be substituted for FCS in human fibroblasts culture and that fibroblasts cultivated in the presence of human serum have a morphology that is similar to in vivo fibroblasts.


INTRODUÇÃO: Soro bovino fetal (SBF) é comumente usado como suplemento no meio de cultura para cultivar fibroblastos. Essa forma de suplementação, porém, não é ideal, pois a qualidade das amostras de SBF é variada e sua composição não é completamente conhecida. Além disso, o SBF pode apresentar contaminação por vírus e príons ou causar complicações imunológicas. Assim, a comunidade científica tem buscado alternativas ao uso de elementos xenobióticos em cultura celular. O soro humano pode ser uma dessas alternativas, principalmente para aplicação clínica. MÉTODO: Soro humano, obtido de sangue de 10 voluntários saudáveis submetidos a avaliação sorológica prévia, foi testado como substituto do SBF em cultura de fibroblastos humanos. As células foram cultivadas em placas multipoços, contendo Dulbecco's Modified Eagle's Medium (DMEM) mais 10 por cento de SBF (D10) ou DMEM mais 10 por cento de sroro humano (D10H). Entre 24 e 264 horas de exposição aos meios testados, as células foram contadas e os resultados foram expressos em média ± erro padrão da média, para obtenção de curvas de proliferação celular. RESULTADOS: Não houve diferença estatística entre os grupos de proliferação. Fibroblastos na presença de soro humano aparentavam ser menores e mais arredondados em comparação àqueles mantidos em D10. CONCLUSÕES: Os resultados permitem inferir que o soro humano pode substituir o SBF em cultura de fibroblastos e que fibroblastos cultivados em meio suplementado por soro humano apresentam morfologia mais semelhante àqueles in vivo.


Assuntos
Animais , Bovinos , História do Século XXI , Sorologia , Células Cultivadas , Técnicas de Cultura de Células , Meios de Cultura , Soro , Proliferação de Células , Fibroblastos , Sorologia/métodos , Células Cultivadas/citologia , Técnicas de Cultura de Células/métodos , Técnicas de Cultura de Células/veterinária , Meios de Cultura/análise , Estudo de Avaliação , Soro/citologia , Fibroblastos/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...