Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Cardiovasc Revasc Med ; 20(9): 775-781, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30420279

RESUMO

INTRODUCTION: Intravascular ultrasound (IVUS) is a useful adjunct to guide percutaneous coronary intervention (PCI). Correlating IVUS images with angiographic findings can be challenging. We evaluated the utility of a novel co-registration system for IVUS and coronary angiography. METHODS AND RESULTS: A 3-D virtual catheter trajectory was constructed from separate angiographic imaging runs using bespoke software. Intravascular ultrasound images were obtained using a commercially available mechanical rotational transducer with motorized pullback. Co-registration of ultrasound and angiographic images was then performed retrospectively based on the length of pullback, the 3-D trajectory and the start position of the catheter. Validation was performed in a spherical phantom model and in vivo in the coronary circulation of patients undergoing coronary angiography and intravascular imaging for clinical purposes. 111 paired angiographic and IVUS runs were performed in 3 phantom models. The differences between the reference length and the length measured on the 3D reconstructed path was -0.01 ±â€¯0.40 mm. Intra-observer variability was 0.4%. We enrolled 25 patients in 3 European hospitals and performed 35 co-registration attempts with an 86% success rate. 71 landmarks were selected by the first operator, 68 by the second. Differences between angiographic and IVUS landmarks were -0.22 ±â€¯0.72 mm and 0.05 ±â€¯1.01 mm, respectively. Inter-observer variability was 0.23 ±â€¯0.63 mm. CONCLUSION: We present a novel method for the co-registration of IVUS and coronary angiographic images. This system performed well in a phantom model and using images obtained from the human coronary circulation. CLASSIFICATIONS: Innovation, intravascular ultrasound, other technique.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imagem Multimodal , Ultrassonografia de Intervenção , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Angiografia Coronária/instrumentação , Europa (Continente) , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção/instrumentação , Adulto Jovem
2.
IEEE J Biomed Health Inform ; 20(2): 606-14, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25700476

RESUMO

Intravascular imaging using ultrasound or optical coherence tomography (OCT) is predominantly used to adjunct clinical information in interventional cardiology. OCT provides high-resolution images for detailed investigation of atherosclerosis-induced thickening of the lumen wall resulting in arterial blockage and triggering acute coronary events. However, the stochastic uncertainty of speckles limits effective visual investigation over large volume of pullback data, and clinicians are challenged by their inability to investigate subtle variations in the lumen topology associated with plaque vulnerability and onset of necrosis. This paper presents a lumen segmentation method using OCT imaging physics-based graph representation of signals and random walks image segmentation approaches. The edge weights in the graph are assigned incorporating OCT signal attenuation physics models. Optical backscattering maxima is tracked along each A-scan of OCT and is subsequently refined using global graylevel statistics and used for initializing seeds for the random walks image segmentation. Accuracy of lumen versus tunica segmentation has been measured on 15 in vitro and 6 in vivo pullbacks, each with 150-200 frames using 1) Cohen's kappa coefficient (0.9786 ±0.0061) measured with respect to cardiologist's annotation and 2) divergence of histogram of the segments computed with Kullback-Leibler (5.17 ±2.39) and Bhattacharya measures (0.56 ±0.28). High segmentation accuracy and consistency substantiates the characteristics of this method to reliably segment lumen across pullbacks in the presence of vulnerability cues and necrotic pool and has a deterministic finite time-complexity. This paper in general also illustrates the development of methods and framework for tissue classification and segmentation incorporating cues of tissue-energy interaction physics in imaging.


Assuntos
Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/métodos , Humanos , Espalhamento de Radiação
3.
Med Image Anal ; 18(1): 103-17, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24184434

RESUMO

Intravascular Ultrasound (IVUS) is a predominant imaging modality in interventional cardiology. It provides real-time cross-sectional images of arteries and assists clinicians to infer about atherosclerotic plaques composition. These plaques are heterogeneous in nature and constitute fibrous tissue, lipid deposits and calcifications. Each of these tissues backscatter ultrasonic pulses and are associated with a characteristic intensity in B-mode IVUS image. However, clinicians are challenged when colocated heterogeneous tissue backscatter mixed signals appearing as non-unique intensity patterns in B-mode IVUS image. Tissue characterization algorithms have been developed to assist clinicians to identify such heterogeneous tissues and assess plaque vulnerability. In this paper, we propose a novel technique coined as Stochastic Driven Histology (SDH) that is able to provide information about co-located heterogeneous tissues. It employs learning of tissue specific ultrasonic backscattering statistical physics and signal confidence primal from labeled data for predicting heterogeneous tissue composition in plaques. We employ a random forest for the purpose of learning such a primal using sparsely labeled and noisy samples. In clinical deployment, the posterior prediction of different lesions constituting the plaque is estimated. Folded cross-validation experiments have been performed with 53 plaques indicating high concurrence with traditional tissue histology. On the wider horizon, this framework enables learning of tissue-energy interaction statistical physics and can be leveraged for promising clinical applications requiring tissue characterization beyond the application demonstrated in this paper.


Assuntos
Inteligência Artificial , Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia de Intervenção/métodos , Algoritmos , Interpretação Estatística de Dados , Humanos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
4.
Comput Med Imaging Graph ; 38(2): 104-12, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24035737

RESUMO

Coronary artery disease leads to failure of coronary circulation secondary to accumulation of atherosclerotic plaques. In adjunction to primary imaging of such vascular plaques using coronary angiography or alternatively magnetic resonance imaging, intravascular ultrasound (IVUS) is used predominantly for diagnosis and reporting of their vulnerability. In addition to plaque burden estimation, necrosis detection is an important aspect in reporting of IVUS. Since necrotic regions generally appear as hypoechic, with speckle appearance in these regions resembling true shadows or severe signal dropout regions, it contributes to variability in diagnosis. This dilemma in clinical assessment of necrosis imaged with IVUS is addressed in this work. In our approach, fidelity of the backscattered ultrasonic signal received by the imaging transducer is initially estimated. This is followed by identification of true necrosis using statistical physics of ultrasonic backscattering. A random forest machine learning framework is used for the purpose of learning the parameter space defining ultrasonic backscattering distributions related to necrotic regions and discriminating it from non-necrotic shadows. Evidence of hunting down true necrosis in shadows of intravascular ultrasound is presented with ex vivo experiments along with cross-validation using ground truth obtained from histology. Nevertheless, in some rare cases necrosis is marginally over-estimated, primarily on account of non-reliable statistics estimation. This limitation is due to sparse spatial sampling between neighboring scan-lines at location far from the transducer. We suggest considering the geometrical location of detected necrosis together with estimated signal confidence during clinical decision making in view of such limitation.


Assuntos
Algoritmos , Doença da Artéria Coronariana/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia de Intervenção/métodos , Simulação por Computador , Humanos , Modelos Cardiovasculares , Necrose/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
IEEE Trans Biomed Eng ; 59(11): 3039-49, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22907962

RESUMO

Intravascular ultrasound (IVUS) is the predominant imaging modality in the field of interventional cardiology that provides real-time cross-sectional images of coronary arteries and the extent of atherosclerosis. Due to heterogeneity of lesions and stringent spatial/spectral behavior of tissues, atherosclerotic plaque characterization has always been a challenge and still is an open problem. In this paper, we present a systematic framework from in vitro data collection, histology preparation, IVUS-histology registration along with matching procedure, and finally a robust texture-derived unsupervised atherosclerotic plaque labeling. We have performed our algorithm on in vitro and in vivo images acquired with single-element 40 MHz and 64-elements phased array 20 MHz transducers, respectively. In former case, we have quantified results by local contrasting of constructed tissue colormaps with corresponding histology images employing an independent expert and in the latter case, virtual histology images have been utilized for comparison. We tackle one of the main challenges in the field that is the reliability of tissues behind arc of calcified plaques and validate the results through a novel random walks framework by incorporating underlying physics of ultrasound imaging. We conclude that proposed framework is a formidable approach for retrieving imperative information regarding tissues and building a reliable training dataset for supervised classification and its extension for in vivo applications.


Assuntos
Técnicas Histológicas/métodos , Processamento de Imagem Assistida por Computador/métodos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Ultrassonografia de Intervenção/métodos , Algoritmos , Ecocardiografia , Humanos , Miocárdio/patologia
6.
IEEE Trans Inf Technol Biomed ; 16(5): 823-34, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22389156

RESUMO

Over the past two decades, intravascular ultrasound (IVUS) image segmentation has remained a challenge for researchers while the use of this imaging modality is rapidly growing in catheterization procedures and in research studies. IVUS provides cross-sectional grayscale images of the arterial wall and the extent of atherosclerotic plaques with high spatial resolution in real time. In this paper, we review recently developed image processing methods for the detection of media-adventitia and luminal borders in IVUS images acquired with different transducers operating at frequencies ranging from 20 to 45 MHz. We discuss methodological challenges, lack of diversity in reported datasets, and weaknesses of quantification metrics that make IVUS segmentation still an open problem despite all efforts. In conclusion, we call for a common reference database, validation metrics, and ground-truth definition with which new and existing algorithms could be benchmarked.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Túnica Adventícia/diagnóstico por imagem , Animais , Humanos , Mamíferos , Processamento de Sinais Assistido por Computador , Túnica Média/diagnóstico por imagem
7.
IEEE Trans Inf Technol Biomed ; 12(3): 315-27, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18693499

RESUMO

In vivo plaque characterization is an important research field in interventional cardiology. We will study the realistic challenges to this goal by deploying 40 MHz single-element, mechanically rotating transducers. The intrinsic variability among the transducers' spectral parameters as well as tissue signals will be demonstrated. Subsequently, we will show that global data normalization is not suited for data calibration, due to the aforementioned variations as well as the stringent characteristics of spectral features. We will describe the sensitivity of an existing feature extraction algorithm based on eight spectral signatures (integrated backscatter coefficient, slope, midband-fit (MBF), intercept, and maximum and minimum powers and their relative frequencies) to a number of factors, such as the window size and order of the autoregressive (AR) model. It will be further demonstrated that the variations in the transducer's spectral parameters (i.e., center frequency and bandwidth) cause inconsistencies among extracted features. In this paper, two fundamental questions are addressed: 1) what is the best reliable way to extract the most informative features? and 2) which classification algorithm is the most appropriate for this problem? We will present a full-spectrum analysis as an alternative to the eight-feature approach. For the first time, different classification algorithms, such as k-nearest neighbors (k-NN) and linear Fisher, will be employed and their performances quantified. Finally, we will explore the reliability of the training dataset and the complexity of the recognition algorithm and illustrate that these two aspects can highly impact the accuracy of the end result, which has not been considered until now.


Assuntos
Algoritmos , Inteligência Artificial , Doença da Artéria Coronariana/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia de Intervenção/métodos , Bases de Dados Factuais , Elasticidade , Humanos , Aumento da Imagem/métodos , Armazenamento e Recuperação da Informação/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Eur Heart J ; 29(17): 2141-7, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18596073

RESUMO

AIMS: We hypothesized a relationship between virtual histology intravascular ultrasound (VH-IVUS) findings and risk factors histopathologically associated with sudden coronary death (SCD) in men: cigarette smoking and an increased total cholesterol-to-high-density lipoprotein cholesterol (HDL-C) ratio (TC/HDL > 5). METHODS AND RESULTS: We assessed volumetric VH-IVUS parameters in a consecutive series of 473 male patients: fibrous, fibro-fatty, dense calcium (DC), necrotic core (NC), and a calculated NC/DC ratio. Patients' age was 61 ± 11 years, with 27% smokers and 69% having a lipid disorder. The NC/DC ratio was the only VH-IVUS parameter related to both TC/HDL ratio (r = 0.18, P= 0.0008) and low-density lipoprotein cholesterol levels (r = 0.17, P= 0.002); had a negative correlation with HDL-C levels (r = -0.11, P= 0.03); and was higher for smokers [median 1.98 (1.35-3.18)] vs. non-smokers [median 1.70 (1.23-2.53), P= 0.006]. An NC/DC value >3 was the threshold that best identified smokers and/or patients presenting TC/HDL >5 (odds ratio 3.0, 95% CI 1.7-4.9, P= 0.0001), and receiver-operator curves showed the superiority of the NC/DC ratio [area under curve (AUC) 0.64, P < 0.0001] over %DC (AUC 0.58, P= 0.006) or %NC (AUC 0.51, P= 0.43) to identify these patients. CONCLUSION: The ratio of NC to calcification detected by VH-IVUS in diseased coronary segments is related to known risk factors for SCD and, thus, may be associated with a worse prognosis.


Assuntos
Calcinose/patologia , Doença da Artéria Coronariana/patologia , Morte Súbita Cardíaca/patologia , Idoso , Calcinose/sangue , Calcinose/diagnóstico por imagem , Simulação por Computador , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Dislipidemias/sangue , Dislipidemias/patologia , Humanos , Lipídeos/sangue , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Estudos Prospectivos , Curva ROC , Sistema de Registros , Fatores de Risco , Ultrassonografia de Intervenção
9.
J Biomed Opt ; 13(3): 034003, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18601548

RESUMO

Intravascular optical coherence tomography (OCT) has been proven a powerful diagnostic tool for cardiovascular diseases. However, the optical mechanism for the qualitative observations are still absent. We address the fundamental issues that underlie the tissue characterization of OCT images obtained from coronary arteries. For this, we investigate both the attenuation and the backscattering properties of different plaque components of postmortem human cadaver coronary arteries. The artery samples are examined both from lumen surface using a catheter and from transversely cut surface using an OCT microscope, where OCT images could be matched to histology exactly. Light backscattering coefficient microb and attenuation coefficients microt are determined for three basic plaque types based on a single-scattering physical model: calcification (microb=4.9+/-1.5 mm(-1), microt=5.7+/-1.4 mm(-1)), fibers (microb=18.4+/-6.4 mm(-1), microt=6.4+/-1.2 mm(-1)), and lipid pool (microb=28.1+/-8.9 mm(-1), microt=13.7+/-4.5 mm(-1)). Our results not only explain the origins of many qualitative OCT features, but also show that combination of backscattering and attenuation coefficient measurements can be used for contrast enhancing and better tissue characterization.


Assuntos
Algoritmos , Doença da Artéria Coronariana/patologia , Interpretação de Imagem Assistida por Computador/métodos , Fotometria/métodos , Tomografia de Coerência Óptica/métodos , Humanos , Aumento da Imagem/métodos , Luz , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
10.
Am J Cardiol ; 101(5): 573-8, 2008 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-18308001

RESUMO

Increased creatine kinase-MB levels and ST-segment depression are well-known prognostic factors in the setting of non-ST-elevation acute coronary syndrome (ACS). We hypothesized a relationship between virtual histology intravascular ultrasound (VH-IVUS) findings and these prognostic factors. We performed "whole vessel" VH-IVUS analysis in culprit arteries of 225 patients with ACS and measured the 4 basic VH-IVUS coronary plaque components--fibrous, fibrofatty, dense calcium (DC), and necrotic core (NC)--and calculated a NC/DC ratio. Patients' age was 62 +/- 11 years; 72% were men and 23% had diabetes. Only the NC/DC ratio had a positive association with creatine kinase-MB levels (r = 0.21, p = 0.03), and it was significantly higher for patients with ST-depression compared with those with non-ST-depression ACS (1.97 +/- 1.46 vs 1.58 +/- 1.10, p = 0.02). Sensitivity and specificity curves determined that a NC/DC value > or =2 (odds ratio 3.8, p = 0.01) and percentage of NC > or =6 (odds ratio 3.1, p = 0.04) were thresholds that best separated patients with high-risk non-ST-elevation ACS from those without abnormal creatine kinase-MB or ST depression. Patients with both predictors had significantly higher total cholesterol (204.7 +/- 60.5 vs 173.6 +/- 44.3 mg/dl, p = 0.01), higher low-density liprotein cholesterol (132.5 +/- 49.8 vs 101.3 +/- 33.2 mg/dl, p = 0.02), and more myocardial injury (creatine kinase-MB value of 42 +/- 38 vs 12 +/- 21, p = 0.01) than patients with no predictors. In conclusion, VH-IVUS analysis showed that the percentage of NC and its ratio to DC in diseased coronary segments are positively associated with a high-risk ACS presentation.


Assuntos
Síndrome Coronariana Aguda/patologia , Calcinose/patologia , Vasos Coronários/patologia , Biomarcadores/sangue , Colesterol/sangue , Doença da Artéria Coronariana/patologia , Creatina Quinase/sangue , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Prognóstico , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Fumar/patologia , Túnica Média/patologia , Ultrassonografia de Intervenção
11.
J Biomech ; 41(2): 383-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17920068

RESUMO

At present, the deployment of an intravascular stent has become a common and widely used minimally invasive treatment for coronary heart disease. To improve these coronary revascularization procedures (e.g. reduce in-stent restenosis rates) the optimal strategy lies in the further development of stent design, material and coatings. In the context of optimizing the stent design, computational models can provide an excellent research tool. In this study, the hypothesis that the free expansion of a stent is determined by the unfolding and expansion of the balloon is examined. Different expansion modeling strategies are studied and compared for a new generation balloon-expandable coronary stent. The trifolded balloon methodology presented in this paper shows very good qualitative and quantitative agreement with both manufacturer's data and experiments. Therefore, the proposed numerical expansion strategy appears to be a very promising optimization methodology in stent design.


Assuntos
Prótese Vascular , Cateterismo/instrumentação , Desenho Assistido por Computador , Modelos Teóricos , Stents , Simulação por Computador , Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Elementos Finitos , Estresse Mecânico
12.
Clin Sci (Lond) ; 114(6): 441-7, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17919124

RESUMO

To date, the main cardiovascular application of TDI (tissue Doppler imaging) has been in myocardial evaluation. In the present study, we investigated the feasibility and reproducibility of assessing arterial elasticity using the DC (distensibility coefficient) measured by TDI, the correlation of this with the DC obtained by other methods and the DC in patients with various degrees of cardiovascular risk. We studied 450 subjects (256 men; age, 51+/-10 years) with and without risk factors of cardiovascular disease. Arterial displacement was measured from TDI, and B-mode and M-mode images of the common carotid artery in the longitudinal plane, and the DC with each method was compared. Linear regression showed a good correlation between all three methods. The results for TDI and B-mode were comparable [(21+/-10) compared with (21+/-10)x10(-3)/kPa respectively; P=not significant], but there were significant differences between TDI and M-mode [(21+/-10) compared with (31+/-13)x10(-3)/kPa respectively; P<0.0001] and between B-mode and M-mode [(21+/-10) compared with (31+/-13)x10(-3)/kPa respectively; P<0.0001]. Similarly, Bland-Altman analysis showed the least variability in the DC between TDI and B-mode, and there were no significant differences between the average measurements. The TDI DC also had the lowest paired difference for inter-observer variability [(-0.1+/-1.1)x10(-3)/kPa; P=not significant]. In conclusion, the results of the present study suggest that TDI of the carotid arteries is feasible, comparable with B-mode measurements, more robust than M-mode and less variable than the other methods.


Assuntos
Doenças Cardiovasculares/fisiopatologia , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/fisiopatologia , Adulto , Doenças Cardiovasculares/etiologia , Complacência (Medida de Distensibilidade) , Elasticidade , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Ultrassonografia Doppler/métodos , Resistência Vascular
13.
J Am Soc Echocardiogr ; 21(2): 123-8, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17686611

RESUMO

BACKGROUND: Reduced total arterial compliance (TAC) may be a marker of preclinical vascular disease. Irreversible risk factors such as age and body habitus are determinants of TAC, the importance of which may have been hidden by reports in selected subgroups, such as the elderly and those with diabetes mellitus or hypertension. We sought the comparative influence of reversible and irreversible risk factors on TAC in a large primary prevention group. MATERIALS AND METHODS: We studied 720 consecutive patients with and without cardiovascular risk factors but with no overt cardiovascular disease. TAC was calculated by the pulse-pressure method from simultaneous applanation tonometry and left ventricular outflow tract Doppler. Central pressure was derived using a transfer function from the radial tonometric waveform and calibrated using mean and diastolic brachial cuff pressure. RESULTS: There were 192 patients with no cardiovascular risk factors, 180 patients with one cardiovascular risk factor, 173 patients with two cardiovascular risk factors, and 175 patients with three or more risk factors. Although age, gender, height, weight, hypertension, diabetes mellitus, hyperlipidemia, and number of risk factors were all significantly associated with TAC, age accounted for approximately 13% of the variance, and the only other independent predictors were height and weight. TAC was not significantly different in age-matched subgroups with single risk factors. CONCLUSION: TAC is associated with multiple risk factors, but age is a major determinant. The influence of age and other correlates may dwarf the contribution of individual risk factors and therefore their alteration with therapy.


Assuntos
Aorta/diagnóstico por imagem , Débito Cardíaco/fisiologia , Doenças Cardiovasculares/epidemiologia , Ultrassonografia Doppler Dupla/métodos , Resistência Vascular/fisiologia , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Aorta/fisiopatologia , Determinação da Pressão Arterial , Doenças Cardiovasculares/diagnóstico por imagem , Complacência (Medida de Distensibilidade) , Estudos Transversais , Feminino , Humanos , Hiperlipidemias/epidemiologia , Hipertensão/epidemiologia , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Distribuição por Sexo , Fumar/epidemiologia
14.
J Invasive Cardiol ; 19(11): 464-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17986721

RESUMO

BACKGROUND: The intravascular ultrasound (IVUS) findings during repeat intervention for drug-eluting stent (DES) restenosis have not been well described. METHODS: We identified 62 consecutive DES restenosis lesions (45 sirolimus-eluting stents and 17 paclitaxel-eluting stents) undergoing repeat intervention with pre and postintervention IVUS. Lumen, stent and intimal hyperplasia (stent minus lumen) areas were measured at the minimal lumen area (MLA) site and minimal stent area (MSA) site. RESULTS: Repeat stent implantation was performed in 55 lesions (88.7%). Overall, MLA increased from 2.3 +/- 0.7 mm(2) preintervention to 4.6 +/- 1.6 mm(2) postintervention. Preintervention MLA was seen at exactly the preintervention MSA site in 42%, while 73% of postintervention MLAs were located at the preintervention MSA site. There was a strong correlation between the preintervention MSA and the postintervention MLA (r = 0.79; p < 0.001). Preintervention MSA was the strongest independent predictor of a larger postintervention MLA (coefficient 0.72; p < 0.001). CONCLUSIONS: The preintervention MSA was a major predictor of larger lumen area after repeat intervention for DES restenosis. Several IVUS studies have shown that stent dimensions do not change over time. Therefore, the MSA of the original stent implantation procedure still has the greatest impact on subsequent interventions to treat DES restenosis.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/terapia , Stents Farmacológicos , Ultrassonografia de Intervenção , Idoso , Antineoplásicos Fitogênicos/administração & dosagem , Angiografia Coronária , Feminino , Humanos , Imunossupressores/administração & dosagem , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem
15.
Am Heart J ; 154(5): 983-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17967608

RESUMO

BACKGROUND: Angiographic assessment of a left main coronary artery stenosis (LMCS) is often difficult and unreliable. We aimed to evaluate the severity of ambiguous LMCSs by intravascular ultrasound (IVUS) and to clarify how frequently significant stenosis occurs in the "real world". METHODS: We retrospectively found 115 consecutive patients in our clinical IVUS database with a de novo, angiographically ambiguous, intermediate LMCS who underwent IVUS evaluation. Quantitative coronary angiography (QCA) and IVUS analyses were performed. We define a significant LMCS as a diameter stenosis >50% by QCA and a minimal lumen area <6.0 mm2 by IVUS. RESULTS: Ostial, mid, and distal LMCSs were seen in 44 (38.3%), 6 (5.2%), and 65 (56.5%) lesions. Overall, IVUS minimal lumen area and plaque burden measured 6.8 +/- 2.6 mm2 and 63% +/- 14%. A significant LMCS was seen in 51 (44.3%) lesions by IVUS but in only 15 (13.0%) lesions by QCA. In particular, only 36.4% of ostial lesions had a significant IVUS stenosis, and minimal lumen diameter by QCA was less well correlated with IVUS in ostial lesions than in other lesion locations. CONCLUSIONS: This real-world IVUS analysis showed that less than half of intermediate LMCSs had significant stenoses by IVUS assessment, especially for lesions located at the left main ostium. Such patients deserve IVUS assessment or physiologic assessment before blindly proceeding to revascularization.


Assuntos
Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Idoso , Angiografia Coronária , Feminino , Seguimentos , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
16.
Am J Cardiol ; 100(5): 812-7, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17719325

RESUMO

This study was conducted to determine the influence of lesion preparation using the AngioSculpt balloon on final stent expansion. Stent expansion remains an important predictor of restenosis and subacute thrombosis, even in the drug-eluting stent (DES) era. In these patients, the role of different predilation strategies has yet to be established. Two hundred ninety-nine consecutive de novo lesions treated with 1 >2.5-mm DES (Cypher or Taxus) under intravascular ultrasound guidance without postdilation, using 3 implantation strategies, were studied: (1) direct stenting without predilation (n = 145), (2) predilation with a conventional semi-compliant balloon (n = 117), and (3) predilation with the AngioSculpt balloon (n = 37). Stent expansion was defined as the ratio of intravascular ultrasound-measured minimum stent diameter and minimum stent area to the manufacturer's predicted stent diameter and area. These ratios were larger after AngioSculpt predilation, and a greater percentage of stents had final minimum stent areas >5.0 mm(2) (another commonly accepted criterion of adequate DES expansion). Lesion morphology, stent and lesion length, and reference vessel size did not affect DES expansion. In conclusion, in this observational, nonrandomized study, pretreatment with the AngioSculpt balloon enhanced stent expansion and minimized the difference between predicted and achieved stent dimensions.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Vasos Coronários/diagnóstico por imagem , Endossonografia , Stents , Ultrassonografia de Intervenção , Idoso , Ligas , Angioplastia Coronária com Balão/métodos , Fármacos Cardiovasculares/uso terapêutico , Vasos Coronários/patologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/uso terapêutico , Pressão , Estudos Prospectivos , Sirolimo/uso terapêutico , Propriedades de Superfície
17.
Int J Cardiovasc Imaging ; 23(6): 733-8, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17370139

RESUMO

Accurate length measurements by intravascular ultrasound (IVUS) are necessary for stent length selection and for IVUS volumetric analysis. The comparative accuracy of commercially available transducer pullback systems--a necessity for accurate IVUS length and volume measurements--has never been studied. We evaluated the accuracy of four IVUS pullback systems by studying 180 patients (45 in each group) who had been treated with a single stent of known length. Stented lesions were located in the left anterior descending artery (n = 77), left circumflex artery (n = 41), right coronary artery (n = 41), left main (n = 2), and saphenous vein grafts (n = 19). The known lengths of implanted stents ranged from 8 to 33 mm. The correlations between known stent length and IVUS-measured stent length in each group were 0.92 for CVIS, 0.83 for BSC Galaxy, 0.63 for Endosonics TrackBack, and 0.69 for Volcano Model R-l00 research pullback device, respectively. Furthermore, the absolute value of the difference between the two measurements was 9.1 +/- 13.1%, 8.8 +/- 10.2%, 18.6 +/- 21.5%, and 17.5 +/- 31.4%, respectively. With the Volcano Model R-l00 research pullback device, there were 3 extreme outliers; if these three outliers were excluded, then the correlation improved from 0.69 to 0.91; and the absolute deviation from known stent length improved from 17.5 +/- 31.4% to 9.7 +/- 8.3%. Thus, there is a significant variation in length measurement accuracy among IVUS pullback devices. This should be taken into account both clinically and when planning scientific studies.


Assuntos
Implante de Prótese Vascular/métodos , Estenose Coronária/diagnóstico por imagem , Stents , Ultrassonografia de Intervenção/instrumentação , Idoso , Análise de Variância , Distribuição de Qui-Quadrado , Estenose Coronária/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transdutores
18.
Cardiovasc Ultrasound ; 5: 6, 2007 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-17266772

RESUMO

BACKGROUND: Non-invasive assessment of arterial pressure wave forms using applanation tonometry of the radial or carotid arteries can be technically challenging and has not found wide clinical application. 2D imaging of the common carotid arteries is routinely used and we sought to determine whether arterial waveform measurements could be derived from tissue Doppler imaging (TDI) of the carotid artery. METHODS: We studied 91 subjects (52 men, age 52 +/- 14 years) with and without cardiovascular disease. Tonometry was performed on the carotid artery simultaneously with pulsed wave Doppler of the LVOT and acquired digitally. Longitudinal 2D images of the common carotid artery with and without TDI were also acquired digitally and both TDI and tonometry were calibrated using mean and diastolic cuff pressure and analysed off line. RESULTS: Correlation between central pressure by TDI and tonometry was excellent for maximum pressure (r = 0.97, p < 0.0001). The mean differences between central pressures derived by TDI and tonometry were minimal (systolic 5.36 +/- 5.5 mmHg; diastolic 1.2 +/- 1.2 mmHg). CONCLUSION: Imaging of the common carotid artery motion with tissue Doppler may permit acquisition of a waveform analogous to that from tonometry. This method may simplify estimation of central arterial pressure and calculation of total arterial compliance.


Assuntos
Determinação da Pressão Arterial/métodos , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/fisiopatologia , Ecocardiografia Doppler/métodos , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Pulsátil
19.
Am Heart J ; 153(2): 297-303, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17239693

RESUMO

BACKGROUND: In the drug-eluting stent (DES) era, stent expansion remains an important predictor of restenosis and subacute thrombosis. Compliance charts are developed to predict final minimum stent diameter (MSD) and area (MSA). The objectives of the study were (1) to assess DES expansion by comparing intravascular ultrasound (IVUS)-measured MSD and MSA against the values predicted by compliance charts and (2) to compare each DES against its bare-metal stent (BMS) equivalent. METHODS: We enrolled 200 patients with de novo coronary lesions treated with single, >2.5-mm Cypher (Cordis, Johnson & Johnson, Miami Lakes, FL) (sirolimus-eluting stent [SES], 133 patients) or Taxus (Boston Scientific, Natick, MA) (paclitaxel-eluting stent [PES], 67 patients) stent under IVUS guidance without another postdilation balloon. We used a comparison cohort of 65 equivalent BMS (Express 2 [Boston Scientific], 37 patients; Bx Velocity [Cordis, Johnson & Johnson], 28 patients) deployed under similar conditions. RESULTS: The DES achieved only 75% +/- 10% of predicted MSD and 66% +/- 17% of predicted MSA; this was similar for SES and PES. Furthermore, 24% of SES and 28% of PES did not achieve a final MSA of 5 mm(2), a consistent predictor of DES failure. The SES achieved 75% +/- 10% of predicted MSA versus 75% +/- 9% for Bx Velocity (P = .9). The PES achieved 79.9% +/- 14% of predicted MSA versus 79% +/- 10% for Express 2 (P = .8). Lesion morphology, arc and length of calcium, stent diameter and length, and implantation pressures did not affect expansion. CONCLUSIONS: Compliance charts fail to predict final MSD and MSA. A considerable percentage of DES does not achieve minimum standards of stent expansion. The SES and PES achieve similar expansion to their BMS platform, indicating that the polymer coating does not affect DES expansion in vivo. However, stent expansion cannot be predicted from preintervention IVUS lesion assessment.


Assuntos
Estenose Coronária/terapia , Sistemas de Liberação de Medicamentos , Stents , Ultrassonografia de Intervenção , Reestenose Coronária/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...