Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-22271399

RESUMO

BackgroundIn October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies." SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. MethodsTo facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. SARS-CoV-2 serology standard reference material and First WHO International Standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. ResultsSeroNet institutions reported development of a total of 27 ELISA methods, 13 multiplex assays, 9 neutralization assays, and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. ConclusionsSeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 virus and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons.

2.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21265422

RESUMO

The SARS-CoV-2 pandemic has impacted public health systems all over the world. The Delta variant seems to possess enhanced transmissibility, but no clear evidence suggests it has increased virulence. Our data shows that pre-exposed individuals had similar neutralizing activity against the authentic COVID-19 strain and the Delta and Epsilon variants. After one vaccine dose, the neutralization capacity expands to all tested variants. Healthy vaccinated individuals showed a limited breadth of neutralization. One vaccine dose induced similar neutralizing antibodies against the Delta compared to the authentic strain. However, even after two doses, this capacity only expanded to the Epsilon variant.

3.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21263211

RESUMO

Patients with immune conditions and immune-modifying therapies were excluded from the Covid-19 vaccine trials. Studies have shown conflicting response to different vaccines in persons receiving immune suppressors or biologics. The aim of this study is to evaluate humoral and cellular response to Covid-19 vaccines in patients with Inflammatory Bowel Disease (IBD) using biologic and/or immunomodulatory (IMM) therapies. MethodsParticipants are adults with IBD receiving biologics or IMM planning to receive a Covid 19 vaccine. Cellular immunity (CD4+ and CD8+ T cell levels) with flow cytometry are measured at baseline and 2 weeks after each vaccine dose. Humoral immunity (antibody titers and neutralizing capacity,VNT%) is analyzed by ELISA at baseline, 2 weeks after each dose, and 6 and 12 months after vaccine. We present the early results of the first 19 subjects. The study is approved by the IRB. Results19 subjects (18 in biologics and 1 in IMM) who received 2 doses of the Pfizer-BioNTech vaccine are included. Total IgG antibodies increased 21.13 times after the first dose and 90 times after the second dose. VTN% increased 11.92 times after the first dose and 53.79 times after the second dose. When compared with a healthy control cohort, total IgG antibodies and VTN% were lower in the subjects after the first dose. After the second dose, IgG antibodies increased but remained lower than controls, but VTN% were similar to controls. CD4 and CD8 mean levels had an upward trend after vaccination. ConclusionsNeutralizing capacity response to the vaccine in subjects was similar to a healthy cohort in spite of lower increases in total IgG antibodies. The CD4 and CD8 results observed may support the capacity to mount an effective cellular response in patients on biologics. Larger studies are needed to determine vaccine efficacy in these patients.

4.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21257975

RESUMO

Both the SARS-CoV-2 pandemic and emergence of variants of concern have highlighted the need for functional antibody assays to monitor the humoral response over time. Antibodies directed against the spike (S) protein of SARS-CoV-2 are an important component of the neutralizing antibody response. In this work, we report that in a subset of patients--despite a decline in total S-specific antibodies--neutralizing antibody titers remain at a similar level for an average of 98 days in longitudinal sampling of a cohort of 59 Hispanic/Latino patients exposed to SARS-CoV-2. We also report that serum neutralization capacity correlates with IgG titers, wherein IgG1 was the predominant isotype (62.71%), followed by IgG4 (15.25%), IgG3 (13.56%), and IgG2 (8.47%) at the earliest tested timepoint. IgA titers were detectable in just 28.81% of subjects, and only 62.71% of subjects had detectable IgM in the first sample despite confirmation of infection by a molecular diagnostic assay. Our data suggests that 100% of seroconverting patients make detectable neutralizing antibody responses which can be quantified by a surrogate viral neutralization test. Examination of sera from 10 out of the 59 subjects which had received an initial first dose of mRNA-based vaccination revealed that both IgG titers and neutralizing activity of sera were higher after vaccination compared to a cohort of 21 SARS-CoV-2 naive subjects. One dose was sufficient for induction of neutralizing antibody, but two doses were necessary to reach 100% surrogate virus neutralization in subjects irrespective of previous SARS-CoV-2 natural infection status. Like the pattern seen after natural infection, after the second vaccine dose, the total anti-S antibodies titers declined, however, neutralizing activity remained relatively constant for more than 80 days after the first vaccine dose. The decline in anti-S antibody titer, however, was significantly less in pre-exposed individuals, highlighting the potential for natural infection to prime a more robust immune response to the vaccine. Furthermore, our data indicates that--compared with mRNA vaccination--natural infection induces a more robust humoral immune response in unexposed subjects. However, this difference was significant only when neutralizing antibody titers were compared among the two groups. No differences were observed between naturally infected and vaccinated individuals when total anti-S antibodies and IgG titers were measured. This work is an important contribution to understanding the natural immune response to the novel coronavirus in a population severely impacted by SARS-CoV-2. Furthermore, by comparing the dynamics of the immune response after the natural infection vs. the vaccination, these findings suggest that a functional neutralizing antibody tests are more relevant indicators than the presence or absence of binding antibodies. In this context, our results also support standardizing methods of assessing the humoral response to SARS-CoV-2 when determining vaccine efficacy and describing the immune correlates of protection for SARS-CoV-2.

5.
Preprint em Inglês | bioRxiv | ID: ppbiorxiv-261727

RESUMO

Natural infection of SARS-CoV-2 in humans leads to the development of a strong neutralizing antibody response, however the immunodominant targets of the polyclonal neutralizing antibody response are still unknown. Here, we functionally define the role SARS-CoV-2 spike plays as a target of the human neutralizing antibody response. In this study, we identify the spike protein subunits that contain antigenic determinants and examine the neutralization capacity of polyclonal sera from a cohort of patients that tested qRT-PCR-positive for SARS-CoV-2. Using an ELISA format, we assessed binding of human sera to spike subunit 1 (S1), spike subunit 2 (S2) and the receptor binding domain (RBD) of spike. To functionally identify the key target of neutralizing antibody, we depleted sera of subunit-specific antibodies to determine the contribution of these individual subunits to the antigen-specific neutralizing antibody response. We show that epitopes within RBD are the target of a majority of the neutralizing antibodies in the human polyclonal antibody response. These data provide critical information for vaccine development and development of sensitive and specific serological testing.

6.
Preprint em Inglês | bioRxiv | ID: ppbiorxiv-146332

RESUMO

The current COVID-19 epidemic imposed an unpreceded challenge to the scientific community in terms of treatment, epidemiology, diagnosis, social interaction, fiscal policies and many other areas. The development of accurate and reliable diagnostic tools (high specificity and sensitivity) is crucial in the current period, the near future and in the long term. These assays should provide guidance to identify immune presumptive protected persons, potential plasma, and/or B cell donors and vaccine development among others. Also, such assays will be contributory in supporting prospective and retrospective studies to identify the prevalence and incidence of COVID-19 and to characterize the dynamics of the immune response. As of today, only thirteen serological assays have received the Emergency Use Authorization (EUA) by the U.S. Federal Drug Administration (FDA). In this work we describe the development and validation of a quantitative IgG enzyme-linked immunoassay (ELISA) using the recombinant SARS-CoV-2 Spike Protein S1 domain, containing the receptor-binding domain (RBD), showing 98% sensitivity, 98.9% specificity and positive and negative predictive values of 100% and 99.2%, respectively. The assay showed to be useful to test for SARS-CoV-2 IgG antibodies in plasma samples from COVID-19-recovered subjects as potential donors for plasmapheresis. This assay is currently under review by the Federal Drug Administration for an Emergency Use Authorization request (Submission Number EUA201115).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...