Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mil Med ; 183(suppl_1): 276-286, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29635587

RESUMO

Combat helmets are expected to protect the warfighter from a variety of blunt, blast, and ballistic threats. Their blunt impact performance is evaluated by measuring linear headform acceleration in drop tower tests, which may be indicative of skull fracture, but not necessarily brain injury. The current study leverages a blunt impact biomechanics model consisting of a head, neck, and helmet with a suspension system to predict how pad stiffness affects both (1) linear acceleration alone and (2) brain tissue response induced by both linear and rotational acceleration. The approach leverages diffusion tensor imaging information to estimate how pad stiffness influences white matter tissue strains, which may be representative of diffuse axonal injury. Simulation results demonstrate that a softer pad material reduces linear head accelerations for mild and moderate impact velocities, but a stiffer pad design minimizes linear head accelerations at high velocities. Conversely, white matter tract-oriented strains were found to be smallest with the softer pads at the severe impact velocity. The results demonstrate that the current helmet blunt impact testing standards' standalone measurement of linear acceleration does not always convey how the brain tissue responds to changes in helmet design. Consequently, future helmet testing should consider the brain's mechanical response when evaluating new designs.


Assuntos
Aceleração/efeitos adversos , Desenho de Equipamento/métodos , Dispositivos de Proteção da Cabeça/normas , Leucoencefalopatias/patologia , Fenômenos Biomecânicos , Imagem de Tensor de Difusão/métodos , Desenho de Equipamento/normas , Dispositivos de Proteção da Cabeça/estatística & dados numéricos , Humanos , Estudos de Validação como Assunto
2.
Artigo em Inglês | MEDLINE | ID: mdl-25023222

RESUMO

In order to replicate the fracture behavior of the intact human skull under impact it becomes necessary to develop a material having the mechanical properties of cranial bone. The most important properties to replicate in a surrogate human skull were found to be the fracture toughness and tensile strength of the cranial tables as well as the bending strength of the three-layer (inner table-diplöe-outer table) architecture of the human skull. The materials selected to represent the surrogate cranial tables consisted of two different epoxy resins systems with random milled glass fiber to enhance the strength and stiffness and the materials to represent the surrogate diplöe consisted of three low density foams. Forty-one three-point bending fracture toughness tests were performed on nine material combinations. The materials that best represented the fracture toughness of cranial tables were then selected and formed into tensile samples and tested. These materials were then used with the two surrogate diplöe foam materials to create the three-layer surrogate cranial bone samples for three-point bending tests. Drop tower tests were performed on flat samples created from these materials and the fracture patterns were very similar to the linear fractures in pendulum impacts of intact human skulls, previously reported in the literature. The surrogate cranial tables had the quasi-static fracture toughness and tensile strength of 2.5 MPa√ m and 53 ± 4.9 MPa, respectively, while the same properties of human compact bone were 3.1 ± 1.8 MPa√ m and 68 ± 18 MPa, respectively. The cranial surrogate had a quasi-static bending strength of 68 ± 5.7 MPa, while that of cranial bone was 82 ± 26 MPa. This material/design is currently being used to construct spherical shell samples for drop tower and ballistic tests.

3.
Biomed Sci Instrum ; 48: 324-31, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22846301

RESUMO

Predicting spinal injury under high rates of vertical loading is of interest, but the success of computational models in modeling this type of loading scenario is highly dependent on the material models employed. Understanding the response of these biological materials at high strain rates is critical to accurately model mechanical response of tissue and predict injury. While data exists at lower strain rates, there is a lack of the high strain rate material data that are needed to develop constitutive models. The Split Hopkinson Pressure Bar (SHPB) has been used for many years to obtain properties of various materials at high strain rates. However, this apparatus has mainly been used for characterizing metals and ceramics and is difficult to apply to softer materials such as biological tissue. Recently, studies have shown that modifications to the traditional SHPB setup allow for the successful characterization of mechanical properties of biological materials at strain rates and peak strain values that exceed alternate soft tissue testing techniques. In this paper, the previously-reported modified SHPB technique is applied to characterize human intervertebral disc material under simple shear. The strain rates achieved range from 5 to 250 strain s-1. The results demonstrate the sensitivity to the disc composition and structure, with the nucleus pulposus and annulus fibrosus exhibiting different behavior under shear loading. Shear tangent moduli are approximated at varying strain levels from 5 to 20% strain. This data and technique facilitates determination of mechanical properties of intervertebral disc materials under shear loading, for eventual use in constitutive models.

4.
Biomed Sci Instrum ; 48: 485-92, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22846323

RESUMO

ehind Armor Blunt Trauma (BABT) is a persistent concern for both the military and civil law enforcement. Although personal protective equipment (PPE), including soft and hard body armor, mitigates penetrating injuries from ballistic threats, the impact generates a backface deformation which creates a high-rate blunt impact to the body and potential internal injury (i.e., BABT). A critical need exists to understand the mechanics of the human response and subsequently evaluate the efficacy of current and proposed PPE in mitigating BABT injury risk. Current human surrogate test platforms lack anatomical fidelity or instrumentation for capturing the dynamic transfer of energy during the event. Therefore, we have developed and tested a Human Surrogate Torso Model (HSTM) composed of biosimulants representing soft tissues and skeleton of the human torso. A matrix of pressure transducers were embedded in the soft tissue and a custom displacement sensor was mounted to the skeletal structure to measure sternum displacement. A series of non-penetrating, high energy ballistic tests were performed with the HSTM. Results indicate that both sternum displacement and internal localized pressure are sensitive to impact energy and location. These data provide a spatial and temporal comparison to the current standard (static clay measurements) and a method for evaluating the applicability of thoracic injury metrics, including the Viscous Criterion, for BABT. The HSTM provides an advanced, biomechanically relevant test platform for determining the thoracic response to dynamic loading events due to non-penetrating ballistic impacts.

5.
Artigo em Inglês | MEDLINE | ID: mdl-21937339

RESUMO

Ultrasound test objects containing reference point targets could be useful for evaluating ultrasound systems and phase aberration correction methods. Polyacrylamide gels containing albumin-stabilized droplets (3.6 µm mean diameter) of dodecafluoropentane (DDFP) are being developed for this purpose. Perturbation by ultrasound causes spontaneous vaporization of the superheated droplets to form gas bubbles, a process termed acoustic droplet vaporization (ADV). The resulting bubbles (20 to 160 µmm diameter) are small compared with acoustic wavelengths in diagnostic ultrasound and are theoretically suitable for use as point targets (phase errors < 20° for typical f-numbers). Bubbles distributed throughout the material are convenient for determining the point spread function in an imaging plane or volume. Cooling the gel causes condensation of the DDFP droplets, which may be useful for storage. Studying ADV in such viscoelastic media could provide insight into potential bioeffects from rapid bubble formation.


Assuntos
Imagens de Fantasmas , Ultrassonografia/instrumentação , Acústica , Resinas Acrílicas/química , Albuminas/química , Fluorocarbonos/química , Humanos , Microbolhas , Modelos Químicos , Tamanho da Partícula , Ultrassonografia/normas , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...