Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Europace ; 21(3): 502-510, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30508076

RESUMO

AIMS: Anatomical placement of the coronary sinus (CS) lead in basal or mid-ventricular positions of the posterior and lateral walls is associated with a better clinical outcome of cardiac resynchronization therapy (CRT). We hypothesized that optimization of CS lead placement targeted the right-to-left electrical delay (RLD) predicts an additional clinical benefit. METHODS AND RESULTS: The CS lead was placed according to current standards in 90 patients (Conventional group) and at the site of the longest RLD in 121 patients (RLD group). Non-responders were defined as those who died or underwent hospitalization for heart failure or did not improve in their Clinical Composite Score within 6 months. There were 67 (32%) non-responders. Compared with Conventional group, the final CS pacing site was more frequently in the basal segments in the RLD group (40% vs. 23%, P = 0.007); moreover, the RLD ratio (%RLD) of the total QRS width was longer (77 ± 13 vs. 73 ± 15, P = 0.05) and biventricular QRS shortened more from the baseline (-31 ± 21 ms vs. -21 ± 26 ms, P = 0.004). Nevertheless, the rate of non-responders was similar in the RLD and Conventional groups (35% vs. 28%, P = 0.30), as was %RLD (76 ± 16 vs. 75 ± 13, P = 0.66). QRS width during right ventricular (RV) pacing was an independent predictors of adverse outcome, with a 2% increase in the risk of failure for each 1 ms increase in QRS (P = 0.006). CONCLUSION: Optimization of CS lead placement targeted to latest electrical activation does not provide additional clinical benefit to anatomical placement in basal or mid-ventricular positions of the posterior and lateral walls. QRS width during RV pacing was a strong predictor of CRT failure. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT03204864.


Assuntos
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Seio Coronário/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Progressão da Doença , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Estudos Prospectivos , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 40(12): 1350-1357, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29023821

RESUMO

AIMS: Left ventricular (LV) lead positioning at the site of delayed electrical activation is associated with better response to cardiac resynchronization therapy (CRT). We hypothesized that a long electrical conduction delay between right ventricular (RV) and coronary sinus (CS) leads during RV pacing (RLD index) is correlated with a better clinical outcome METHODS AND RESULTS: RLD is measured intraprocedurally, during RV pacing, as the time interval between the intracardiac electrograms of RV and CS leads. Initially, we did a prove-of-concept, feasibility, acute study in 97 patients who underwent CRT implantation. The CS lead position was assessed in the 40° right anterior oblique and 40° left anterior oblique views and assigned to one of 11 prespecified segments of a schematic eyeball depiction of the LV walls. Acute outcomes were QRS width during biventricular (BIV) pacing. The longest RLD were found in the basal and mid lateral segments; these accounted for 82% and 78%, respectively, of the total QRS width (%RLD). %RLD was inversely correlated with BIV-paced QRS (P  =  0.0001). A similar slope was present either in the 78 patients with preserved atrioventricular (AV) conduction and in the 19 without AV conduction (- 0.34 vs - 0.27, P  =  0.7). CONCLUSION: We showed that RLD can be used to guide lead placement at the time of CRT implantation and that it is correlated with BIV-QRS width, an indirect predictor of clinical outcome. Based on these findings we started the prospective, multicenter Optimal Pacing SITE 2 (OPSITE 2) trial with the objective to demonstrate a relationship between RLD and clinical outcomes assessed as death, hospitalization for heart failure, New York Heart Association class, and clinical composite score. The protocol is provided.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Seio Coronário , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Idoso , Terapia de Ressincronização Cardíaca/normas , Protocolos Clínicos , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...