Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
J Biol Regul Homeost Agents ; 35(3): 881-887, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34231353

RESUMO

Since the spreading of Sar-CoV-2 in March 2020, many serologic tests have been developed to identify antibody responses. Indeed, different commercial kits are directed against different antigens and could utilise different methods thereby triggering confusion and criticism. Here, we compared two Food and Drug Administration (FDA)-approved automatized assays that detect IgG responses against spike or nucleocapsid protein of Sars-Cov-2 virus in 127 subjects among healthcare workers of IRCCS Policlinico San Donato (MI), Italy. We observed different kinetics of IgG responses, demonstrating the importance of timing of sampling to correctly interpret the results both for infection diagnosis and for epidemiologic studies. We observed that Anti-N response starts earlier than Anti-S1/S2 response but also decreases earlier, affecting the sensitivity of the tests at different time points. Combining two different assays, designed against different antigens, could reduce false negative results. Finally, we observed a patient who produced anti-nucleocapsid IgG, but not anti-spike IgG. In conclusion, we investigated antibody responses in Covid-19 disease, aiming to direct clinicians and laboratory scientists to correctly interpret serologic results by always paying attention to clinical history correlation, timing of sampling, methods and antigens used, to avoid false negative results and obtain relevant epidemiologic data.


Assuntos
COVID-19 , Anticorpos Antivirais , Humanos , Imunoglobulina G , Itália , SARS-CoV-2 , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus , Estados Unidos
3.
Phys Med ; 41: 5-12, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28499627

RESUMO

PURPOSE: Three MOSkins dosimeters were assembled over a rectal probe and used to perform in vivo dosimetry during HDR brachytherapy treatments of vaginal cancer. The purpose of this study was to verify the applicability of the developed tool to evaluate discrepancies between planned and measured doses to the rectal wall. MATERIALS AND METHODS: MOSkin dosimeters from the Centre for Medical Radiation Physics are particularly suitable for brachytherapy procedures for their ability to be easily incorporated into treatment instrumentation. In this study, 26 treatment sessions of HDR vaginal brachytherapy were monitored using three MOSkin mounted on a rectal probe. A total of 78 measurements were collected and compared to doses determined by the treatment planning system. RESULTS: Mean dose discrepancy was determined as 2.2±6.9%, with 44.6% of the measurements within ±5%, 89.2% within ±10% and 10.8% higher than ±10%. When dose discrepancies were grouped according to the time elapsed between imaging and treatment (i.e., group 1: ≤90min; group 2: >90min), mean discrepancies resulted in 4.7±3.6% and 7.1±5.0% for groups 1 and 2, respectively. Furthermore, the position of the dosimeter on the rectal catheter was found to affect uncertainty, where highest uncertainties were observed for the dosimeter furthest inside the rectum. CONCLUSIONS: This study has verified MOSkin applicability to in-patient dose monitoring in gynecological brachytherapy procedures, demonstrating the dosimetric rectal probe setup as an accurate and convenient IVD instrument for rectal wall dose verification. Furthermore, the study demonstrates that the delivered dose discrepancy may be affected by the duration of treatment planning.


Assuntos
Braquiterapia , Dosimetria in Vivo , Dosímetros de Radiação , Reto/efeitos da radiação , Neoplasias Vaginais/radioterapia , Feminino , Humanos , Radiometria , Dosagem Radioterapêutica
4.
Med Phys ; 42(12): 7098-107, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26632063

RESUMO

PURPOSE: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. METHODS: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. RESULTS: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. CONCLUSIONS: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView's image processing algorithms.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Próstata/diagnóstico por imagem , Radioterapia Guiada por Imagem/instrumentação , Radioterapia Guiada por Imagem/métodos , Algoritmos , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Desenho de Equipamento , Humanos , Masculino , Modelos Biológicos , Imagens de Fantasmas , Próstata/efeitos da radiação , Radiografia , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Silício , Tungstênio
5.
Eur J Nucl Med Mol Imaging ; 42(11): 1718-1738, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26112387

RESUMO

PURPOSE: The aim of this study was to optimize the dosimetric approach and to review the absorbed doses delivered, taking into account radiobiology, in order to identify the optimal methodology for an individualized treatment planning strategy based on (99m)Tc-macroaggregated albumin (MAA) single photon emission computed tomography (SPECT) images. METHODS: We performed retrospective dosimetry of the standard TheraSphere® treatment on 52 intermediate (n = 17) and advanced (i.e. portal vein thrombosis, n = 35) hepatocarcinoma patients with tumour burden < 50% and without obstruction of the main portal vein trunk. Response was monitored with the densitometric radiological criterion (European Association for the Study of the Liver) and treatment-related liver decompensation was defined ad hoc with a time cut-off of 6 months. Adverse events clearly attributable to disease progression or other causes were not attributed to treatment. Voxel dosimetry was performed with the local deposition method on (99m)Tc-MAA SPECT images. The reconstruction protocol was optimized. Concordance of (99m)Tc-MAA and (90)Y bremsstrahlung microsphere biodistributions was studied in 35 sequential patients. Two segmentation methods were used, based on SPECT alone (home-made code) or on coregistered SPECT/CT images (IMALYTICS™ by Philips). STRATOS™ absorbed dose calculation was validated for (90)Y with a single time point. Radiobiology was used introducing other dosimetric variables besides the mean absorbed dose D: equivalent uniform dose (EUD), biologically effective dose averaged over voxel values (BEDave) and equivalent uniform biologically effective dose (EUBED). Two sets of radiobiological parameters, the first derived from microsphere irradiation and the second from external beam radiotherapy (EBRT), were used. A total of 16 possible methodologies were compared. Tumour control probability (TCP) and normal tissue complication probability (NTCP) were derived. The area under the curve (AUC) of the receiver-operating characteristic (ROC) curve was used as a figure of merit to identify the methodology which gave the best separation in terms of dosimetry between responding and non-responding lesions and liver decompensated vs non-decompensated liver treatment. RESULTS: MAA and (90)Y biodistributions were not different (71% of cases), different in 23% and uncertain in 6%. Response correlated with absorbed dose (Spearman's r from 0.48 to 0.69). Responding vs non-responding lesion absorbed doses were well separated, regardless of the methodology adopted (p = 0.0001, AUC from 0.75 to 0.87). EUBED gave significantly better separation with respect to mean dose (AUC = 0.87 vs 0.80, z = 2.07). Segmentation on SPECT gave better separation than on SPECT/CT. TCP(50%) was at 250 Gy for small lesion volumes (<10 cc) and higher than 1,000 Gy for large lesions (>10 cc). Apparent radiosensitivity values from TCP were around 0.003/Gy, a factor of 3-5 lower than in EBRT, as found by other authors. The dose-rate effect was negligible: a purely linear model can be applied. Toxicity incidence was significantly larger for Child B7 patients (89 vs 14%, p < 0.0001), who were therefore excluded from dose-toxicity analysis. Child A toxic vs non-toxic treatments were significantly separated in terms of dose averaged on whole non-tumoural parenchyma (including non-irradiated regions) with AUC from 0.73 to 0.94. TD50 was ≈ 100 Gy. No methodology was superior to parenchyma mean dose, which therefore can be used for planning, with a limit of TD15 ≈ 75 Gy. CONCLUSION: A dosimetric treatment planning criterion for Child A patients without complete obstruction of the portal vein was developed.


Assuntos
Carcinoma Hepatocelular/terapia , Embolização Terapêutica , Vidro/química , Neoplasias Hepáticas/terapia , Microesferas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioisótopos de Ítrio , Carcinoma Hepatocelular/diagnóstico por imagem , Criança , Relação Dose-Resposta à Radiação , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Medicina de Precisão , Radiobiologia , Radiometria , Estudos Retrospectivos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 2792-5, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26736871

RESUMO

We studied the problem of mortality prediction in 23 septic shock patients selected from the public database MIMIC-II. For each patient we derived hemodynamic variables, laboratory results and clinical information of the first 48 hours after shock onset and we performed univariate and multivariate analyses to predict mortality in the following 7 days. The results show interesting features that individually identify significant differences between survivors and non survivors and features which gain importance only when considered together with the others in a multivariate regression model, such as the respiratory rate (RR). This preliminary study on a small septic shock population represents a novel contribution towards new personalized models for an integration of multi-scale and multi-level patient information to improve critical care management of shock patients.


Assuntos
Choque Séptico , Cuidados Críticos , Hemodinâmica , Humanos , Análise Multivariada , Prognóstico
7.
Phys Med Biol ; 59(21): 6659, 2014 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-25325249

RESUMO

HDR BrachyView is a novel in-body dosimetric imaging system for real-time monitoring and verification of the source position in high dose rate (HDR) prostate brachytherapy treatment. It is based on a high-resolution pixelated detector array with a semi-cylindrical multi-pinhole tungsten collimator and is designed to fit inside a compact rectal probe, and is able to resolve the 3D position of the source with a maximum error of 1.5 mm. This paper presents an evaluation of the additional dose that will be delivered to the patient as a result of backscatter radiation from the collimator. Monte Carlo simulations of planar and cylindrical collimators embedded in a tissue-equivalent phantom were performed using Geant4, with an (192)Ir source placed at two different source-collimator distances. The planar configuration was replicated experimentally to validate the simulations, with a MOSkin dosimetry probe used to measure dose at three distances from the collimator. For the cylindrical collimator simulation, backscatter dose enhancement was calculated as a function of axial and azimuthal displacement, and dose distribution maps were generated at three distances from the collimator surface. Although significant backscatter dose enhancement was observed for both geometries immediately adjacent to the collimator, simulations and experiments indicate that backscatter dose is negligible at distances beyond 1 mm from the collimator. Since HDR BrachyView is enclosed within a 1 mm thick tissue-equivalent plastic shell, all backscatter radiation resulting from its use will therefore be absorbed before reaching the rectal wall or other tissues. dosimetry, brachytherapy, HDR.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/métodos , Tungstênio/química , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Método de Monte Carlo , Neoplasias da Próstata/patologia , Espalhamento de Radiação , Software
8.
Radiat Prot Dosimetry ; 161(1-4): 422-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24435913

RESUMO

Gamma dose and thermal neutron fluence in a phantom exposed to an epithermal neutron beam for boron neutron capture therapy (BNCT) can be measured by means of a single thermoluminescence dosemeter (TLD-700). The method exploits the shape of the glow curve (GC) and requires the gamma-calibration GC (to obtain gamma dose) and the thermal-neutron-calibration GC (to obtain neutron fluence). The method is applicable for BNCT dosimetry in case of epithermal neutron beams from a reactor because, in most irradiation configurations, thermal neutrons give a not negligible contribution to the TLD-700 GC. The thermal neutron calibration is not simple, because of the impossibility of having thermal neutron fields without gamma contamination, but a calibration method is here proposed, strictly bound to the method itself of dose separation.


Assuntos
Terapia por Captura de Nêutron de Boro/métodos , Raios gama , Neoplasias/radioterapia , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Calibragem , Fluoretos , Humanos , Compostos de Lítio , Nêutrons , Imagens de Fantasmas , Fótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes
9.
Oncogene ; 33(25): 3342-50, 2014 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-23873026

RESUMO

PRDM proteins are tissue-specific transcription factors often deregulated in diseases, particularly in cancer where different members have been found to act as oncogenes or tumor suppressors. PRDM5 is a poorly characterized member of the PRDM family for which several studies have reported a high frequency of promoter hypermethylation in cancer types of gastrointestinal origin. We report here the characterization of Prdm5 knockout mice in the context of intestinal carcinogenesis. We demonstrate that loss of Prdm5 increases the number of adenomas throughout the murine small intestine on an Apc(Min) background. By using the genome-wide ChIP-seq (chromatin immunoprecipitation (ChIP) followed by DNA sequencing) and transcriptome analyses we identify loci encoding proteins involved in metabolic processes as prominent PRDM5 targets and characterize monoacylglycerol lipase (Mgll) as a direct PRDM5 target in human colon cancer cells and in Prdm5 mutant mouse intestines. Moreover, we report the downregulation of PRDM5 protein expression in human colon neoplastic lesions. In summary, our data provide the first causal link between Prdm5 loss and intestinal carcinogenesis, and uncover an extensive and novel PRDM5 target repertoire likely facilitating the tumor-suppressive functions of PRDM5.


Assuntos
Adenoma/genética , Polipose Adenomatosa do Colo/genética , Proteínas de Ligação a DNA/genética , Neoplasias Intestinais/genética , Monoacilglicerol Lipases/biossíntese , Fatores de Transcrição/genética , Adenoma/enzimologia , Adenoma/metabolismo , Polipose Adenomatosa do Colo/metabolismo , Animais , Células CACO-2 , Carcinogênese/genética , Carcinogênese/metabolismo , Linhagem Celular Tumoral , Proteínas de Ligação a DNA/metabolismo , Regulação para Baixo , Humanos , Neoplasias Intestinais/enzimologia , Neoplasias Intestinais/metabolismo , Camundongos , Monoacilglicerol Lipases/genética , Monoacilglicerol Lipases/metabolismo , Mutação , Fatores de Transcrição/metabolismo , Sítio de Iniciação de Transcrição , Transcrição Gênica
10.
Appl Radiat Isot ; 83 Pt C: 222-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23810727

RESUMO

MOSkin detectors were studied to perform real-time in vivo dose measurements in high dose rate prostate brachytherapy. Measurements were performed inside an urethral catheter in a gel phantom simulating a real prostate implant. Measured and expected doses were compared and the discrepancy was found to be within 8.9% and 3.8% for single MOSkin and dual-MOSkin configurations, respectively. Results show that dual-MOSkin detectors can be profitably adopted in prostate brachytherapy treatments to perform real-time in vivo dosimetry inside the urethra.


Assuntos
Braquiterapia , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Estudos de Viabilidade , Humanos , Masculino
11.
Artigo em Inglês | MEDLINE | ID: mdl-25570308

RESUMO

We have developed numerical approaches to dynamical analysis of heart rates, measured as interbeat or RR, intervals, based on entropy and fluctuation analyses in a large data base of consecutive Holter monitor recordings. In Part I, we present a RR interval-based classifier that distinguishes normal sinus rhythm (NSR), atrial fibrillation (AF) and sinus rhythm with ectopy with an accuracy of 99%, 81% and 77%respectively, using 10-minute segments. In Part II, we present 2-year mortality estimation based on the entropy calculations. The major finding is that normal dynamics identify a very low risk group. Taken together, these results point to automated analysis of heart rate time series with important clinical applications.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Algoritmos , Bases de Dados Factuais , Entropia , Humanos , Pessoa de Meia-Idade , Modelos Estatísticos , Prognóstico , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
12.
Curr HIV Res ; 10(7): 614-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22934657

RESUMO

INTRODUCTION: Human Papillomavirus infections have been shown to be crucial for the development of cervical intraepithelial neoplasia and subsequent cervical cancer. The aim of this study is to describe the prevalence of different genotypes of HPV, in a population of HIV-positive women, compared to the negative ones, and their oncogenic risk. PATIENTS AND METHOD: A case-control study comparing HPV genotype distribution between 93 HIV-seropositive and 186 HIV-seronegative women, matched for age and severity of cervical lesions, who attending colposcopic service of our departments for periodical Pap smear and HPV DNA full genotyping by SPF-10 LiPA assay. RESULTS: No significant difference was found in genotype distribution between HIV positive and HIV negative women. Only the prevalence of HPV56 was higher in HIV positive women (p=0,046). The rates of HPV 6, 11, 16 and 18 were similar in both groups. The likelihood of the detection of three or more HPV genotypes was significantly associated with CIN (OR=2.0; 95% CI=1.1-3.8; p= 0.026) but only marginally to HIV-positive serostatus (OR=1.68; 95% CI=0.89-3.16; p= 0.1). High grade cervical lesions are associated with high risk viruses like HPV 16 and 18 and with multiple cervical HPV infections. CONCLUSIONS: The tendency to treat HIV disease with high active antiretroviral therapy may reduce the impact of immunosuppression and make the course of such HPV infections more similar to that among women who are not HIVinfected. As in immunocompetent women, high oncogenic risk viral type and multiple infections are associated with a histologically proven cervical intraepithelial lesions.


Assuntos
Alphapapillomavirus , Soronegatividade para HIV , Soropositividade para HIV/patologia , Infecções por Papillomavirus/complicações , Displasia do Colo do Útero/epidemiologia , Displasia do Colo do Útero/virologia , Neoplasias do Colo do Útero/epidemiologia , Neoplasias do Colo do Útero/virologia , Adulto , Alphapapillomavirus/genética , Alphapapillomavirus/patogenicidade , Estudos de Casos e Controles , DNA Viral , Feminino , Genótipo , Soronegatividade para HIV/imunologia , Soropositividade para HIV/epidemiologia , Soropositividade para HIV/virologia , Humanos , Itália/epidemiologia , Pessoa de Meia-Idade , Teste de Papanicolaou , Infecções por Papillomavirus/epidemiologia , Infecções por Papillomavirus/patologia , Infecções por Papillomavirus/virologia , Fatores de Risco , Neoplasias do Colo do Útero/patologia , Esfregaço Vaginal , Displasia do Colo do Útero/patologia
13.
Appl Radiat Isot ; 71 Suppl: 48-51, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22920417

RESUMO

In vivo dosimetry provides information about the actual dose delivered to the patient treated with radiotherapy and can be adopted within a routinary treatment quality assurance protocol. Aim of this study was to evaluate the feasibility of performing in vivo rectal dosimetry by placing thermoluminescence detectors directly on the transrectal ultrasound probe adopted for on-line treatment planning of high dose rate brachytherapy boosts of prostate cancer patients. A suitable protocol for TLD calibration has been set up. In vivo measurements resulted to be in good agreement with the calculated doses, showing that the proposed method is feasible and returns accurate results.


Assuntos
Braquiterapia/métodos , Radioisótopos de Irídio/uso terapêutico , Neoplasias da Próstata/radioterapia , Dosimetria Termoluminescente/métodos , Braquiterapia/normas , Calibragem , Humanos , Masculino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reto , Dosimetria Termoluminescente/instrumentação
15.
Q J Nucl Med Mol Imaging ; 56(6): 503-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23358402

RESUMO

AIM: Our goal was to limit liver toxicity and to obtain good efficacy by developing a dosimetric treatment planning strategy. While several dosimetric evaluations are reported in literature, the main problem of the safety of the treatment is rarely addressed. Our work is the first proposal of a treatment planning method for glass spheres, including both liver toxicity and efficacy issues. METHODS: Fifty-two patients (series 1) had been treated for intermediated/advanced hepatocellular carcinoma (HCC) with glass spheres, according to the Therasphere® prescription of 120 Gy averaged on the injected lobe. They were retrospectively evaluated with voxel dosimetry, adopting the local deposition hypothesis. Regions of interest on tumor and non tumor parenchyma were drawn to determine the parenchyma absorbed dose, averaged also on non irradiated voxels, excluding tumor voxels. The relationship between the mean non tumoral parenchyma absorbed dose D and observed liver decompensation was analyzed. RESULTS: Basal Child-Pugh strongly affected the toxicity incidence, which was 22% for A5, 57% for A6, 89% for B7 patients. Restricting the analysis to our numerically richest class (basal Child-Pugh A5 patients), D median values were significantly different between toxic (median 90 Gy) and non toxic treatments (median 58 Gy) at a Mann-Withney test, (P=0.033). Using D as a marker for toxicity, the separation of the two populations in terms of area under ROC curve was 0.75, with 95% C.I. of [0.55-0.95]. The experimental Normal Tissue Complication Probability (NTCP) curve as a function of D resulted in the following values: 0%, 14%, 40%, 67% for D interval of [0-35] Gy, [35-70] Gy, [70-105] Gy, [105-140] Gy. DISCUSSION: A limit of about 70 Gy for the mean absorbed dose to parenchyma was assumed for A5 patients, corresponding to a 14% risk of liver decompensation. This result is applicable only to our administration conditions: glass spheres after a decay interval of 3.75 days. Different safety limit (40 Gy) are published for resin spheres, characterized by higher number of particle per GBq (more uniform irradiation, bigger biological effect for the same absorbed dose). CONCLUSION: As result of this study we suggest a constraint of about 70 Gy mean absorbed dose to liver non tumoral parenchyma, corresponding to about 15% probability of radioinduced liver decompensation while still aiming at achieving an absorbed of several hundreds of Gy to lesions.


Assuntos
Braquiterapia/métodos , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioisótopos de Ítrio/uso terapêutico , Idoso , Carcinoma Hepatocelular/diagnóstico , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico , Masculino , Microesferas , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Estudos Retrospectivos , Resultado do Tratamento
16.
Appl Radiat Isot ; 69(12): 1911-4, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21497100

RESUMO

Gamma and fast neutron dose spatial distributions have been measured at the collimator exit of the epithermal neutron beam of LVR-15 reactor (Rez). Measurements were performed by means of optically analyzed Fricke-gel-layer detectors. The separation of the two dose contributions has been achieved by suitable pixel-to-pixel elaboration of the light transmittance images of Fricke-gel-layer detectors prepared with water and heavy water.

17.
Appl Radiat Isot ; 68(4-5): 772-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19879155

RESUMO

Normoxic polymer gel dosimeters are studied, with the aim of achieving a valid and advantageous method for in-phantom 3D dose determinations. Developments were carried out in the application of such dosimetric material to the method based on dosimeter gel layers that has shown good reliability for absorbed dose imaging in radiotherapy. The technique has been improved, in particular taking care of minimizing the oxygen infiltration into the gel matrix in order to suitably avoid its effect of inhibiting the polymerization process after exposure. A suitable choice of the material of dosimeter walls has brought to achieve good steadiness in time of dosimeter sensitivity and satisfactory results in dose imaging and depth-dose profiling.


Assuntos
Acrilamidas/química , Acrilamidas/efeitos da radiação , Radiometria/métodos , Radioterapia Conformacional/métodos , Géis/química , Géis/efeitos da radiação , Teste de Materiais , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Appl Radiat Isot ; 68(4-5): 722-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19850485

RESUMO

The aim of this study was to evaluate the reliability of Fricke gel-layer dosimeters for the measurement of in-phantom dose distributions produced by a ((192))Ir brachytherapy source. The doses obtained were compared to measurements performed with thermoluminescent dosimeters and treatment planning calculations. Fricke gel-layer dosimeters have proven to be a promising tool to measure three-dimensional dose distributions in high dose-rate brachytherapy.


Assuntos
Braquiterapia/instrumentação , Dosimetria Termoluminescente/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Compostos Ferrosos/efeitos da radiação , Géis/efeitos da radiação , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soluções/efeitos da radiação , Dosimetria Termoluminescente/métodos
19.
Appl Radiat Isot ; 67(7-8 Suppl): S214-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19376722

RESUMO

A thorax phantom has been designed, consisting of PMMA and PE plates containing a cavity filled with a laboratory-made lung-substitute. Fricke-gel dosimeters have been placed in the lung-substitute volume, and the phantom has been irradiated at the epithermal column of LVR-15 reactor. Absorbed dose images have been obtained for both gamma radiation and charged particles emitted in the (10)B reactions with thermal neutrons. Measurements with thermoluminescence dosimeters (TLDs) and Monte Carlo (MC) calculations have been performed too, in order to attain inter-comparison of results.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Terapia por Captura de Nêutron de Boro/estatística & dados numéricos , Nêutrons Rápidos/uso terapêutico , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Boro/uso terapêutico , República Tcheca , Géis , Humanos , Isótopos/uso terapêutico , Reatores Nucleares , Fótons/uso terapêutico , Radiossensibilizantes/uso terapêutico , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Tórax
20.
Appl Radiat Isot ; 67(7-8 Suppl): S195-8, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19375935

RESUMO

Gel dosimeters in form of layers have shown noticeable potentiality for in-phantom dose profiling and imaging in BNCT neutron fields. Such dosimeters give the possibility of achieving spatial dose distributions of each dose contribution in neutron fields. The various dose components are separated by means of pixel-to-pixel manipulations of pairs of images acquired with gel dosimeters having different isotopic compositions. The reliability of polymer-gel-layer dosimeters (PGLD) for BNCT has been studied and their utilisation limits have been inspected.


Assuntos
Terapia por Captura de Nêutron de Boro/estatística & dados numéricos , Imagens de Fantasmas/estatística & dados numéricos , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Resinas Acrílicas , Géis , Humanos , Itália , Neoplasias/radioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...