Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cell Rep Med ; 5(5): 101544, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38697102

RESUMO

Prime editing is a recent, CRISPR-derived genome editing technology capable of introducing precise nucleotide substitutions, insertions, and deletions. Here, we present prime editing approaches to correct L227R- and N1303K-CFTR, two mutations that cause cystic fibrosis and are not eligible for current market-approved modulator therapies. We show that, upon DNA correction of the CFTR gene, the complex glycosylation, localization, and, most importantly, function of the CFTR protein are restored in HEK293T and 16HBE cell lines. These findings were subsequently validated in patient-derived rectal organoids and human nasal epithelial cells. Through analysis of predicted and experimentally identified candidate off-target sites in primary stem cells, we confirm previous reports on the high prime editor (PE) specificity and its potential for a curative CF gene editing therapy. To facilitate future screening of genetic strategies in a translational CF model, a machine learning algorithm was developed for dynamic quantification of CFTR function in organoids (DETECTOR: "detection of targeted editing of CFTR in organoids").


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística , Fibrose Cística , Células Epiteliais , Edição de Genes , Mutação , Organoides , Humanos , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Fibrose Cística/genética , Fibrose Cística/patologia , Fibrose Cística/metabolismo , Organoides/metabolismo , Edição de Genes/métodos , Células Epiteliais/metabolismo , Mutação/genética , Células HEK293 , Sistemas CRISPR-Cas/genética
2.
Nat Commun ; 15(1): 2504, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509073

RESUMO

Recent research in artificial cell production holds promise for the development of delivery agents with therapeutic effects akin to real cells. To succeed in these applications, these systems need to survive the circulatory conditions. In this review we present strategies that, inspired by the endurance of red blood cells, have enhanced the viability of large, cell-like vehicles for in vivo therapeutic use, particularly focusing on giant unilamellar vesicles. Insights from red blood cells can guide modifications that could transform these platforms into advanced drug delivery vehicles, showcasing biomimicry's potential in shaping the future of therapeutic applications.


Assuntos
Células Artificiais , Eritrócitos , Sistemas de Liberação de Medicamentos , Lipossomas Unilamelares
3.
Adv Sci (Weinh) ; 10(34): e2302461, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37807811

RESUMO

In the quest to produce artificial cells, one key challenge that remains to be solved is the recreation of a complex cellular membrane. Among the existing models, giant unilamellar vesicles (GUVs) are particularly interesting due to their intrinsic compartmentalisation ability and their resemblance in size and shape to eukaryotic cells. Many techniques have been developed to produce GUVs all having inherent advantages and disadvantages. Here, the authors show that fluorinated silica nanoparticles (FNPs) used to form Pickering emulsions in a fluorinated oil can destabilise lipid nanosystems to template the formation of GUVs. This technique enables GUV production across a broad spectrum of buffer conditions, while preventing the leakage of the encapsulated components into the oil phase. Furthermore, a simple centrifugation process is sufficient for the release of the emulsion-trapped GUVs, bypassing the need to use emulsion-destabilising chemicals. With fluorescent FNPs and transmission electron microscopy, the authors confirm that FNPs are efficiently removed, producing contaminant-free GUVs. Further experiments assessing the lateral diffusion of lipids and unilamellarity of the GUVs demonstrate that they are comparable to GUVs produced via electroformation. Finally, the ability of incorporating transmembrane proteins is demonstrated, highlighting the potential of this method for the production of GUVs for artificial cell applications.


Assuntos
Células Artificiais , Lipossomas Unilamelares , Emulsões , Membrana Celular , Proteínas de Membrana
4.
iScience ; 25(7): 104515, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35733793

RESUMO

High-throughput screening and enrichment of antibody-producing cells have many important applications. Herein, we present a droplet microfluidic approach for high-throughput screening and sorting of antibody-secreting cells using a Förster resonance electron transfer (FRET)-based assay. The FRET signal is mediated by the specific binding of the secreted antibody to two fluorescently labeled probes supplied within a droplet. Functional hybridoma cells expressing either membrane-bound or secreted monoclonal antibodies (mAbs), or both, were efficiently differentiated in less than 30 min. The antibody secretion rate by individual hybridoma cells was recorded in the range of 14,000 Abs/min, while the density of membrane-bound fraction was approximately 100 Abs/µm2. Combining the FRET assay with droplet-based single-cell sorting, an 800-fold enrichment of antigen-specific cells was achieved after one round of sorting. The presented system overcomes several key limitations observed in conventional FACS-based screening methods and should be applicable to assaying various other secreted proteins.

5.
Small ; 17(30): e2102145, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34196492

RESUMO

Significant non-genetic stochastic factors affect aging, causing lifespan differences among individuals, even those sharing the same genetic and environmental background. In Caenorhabditis elegans, differences in heat-shock response (HSR) are predictive of lifespan. However, factors contributing to the heterogeneity of HSR are still not fully elucidated. Here, the authors characterized HSR dynamics in isogenic C. elegans expressing GFP reporter for hsp-16.2 for identifying the key contributors of HSR heterogeneity. Specifically, microfluidic devices that enable cross-sectional and longitudinal measurements of HSR dynamics in C. elegans at different scales are developed: in populations, within individuals, and in embryos. The authors adapted a mathematical model of HSR to single C. elegans and identified model parameters associated with proteostasis-maintenance of protein homeostasis-more specifically, protein turnover, as the major drivers of heterogeneity in HSR dynamics. It is verified that individuals with enhanced proteostasis fidelity in early adulthood live longer. The model-based comparative analysis of protein turnover in day-1 and day-2 adult C. elegans revealed a stochastic-onset of age-related proteostasis decline that increases the heterogeneity of HSR capacity. Finally, the analysis of C. elegans embryos showed higher HSR and proteostasis capacity than young adults and established transgenerational contribution to HSR heterogeneity that depends on maternal age.


Assuntos
Proteínas de Caenorhabditis elegans , Caenorhabditis elegans , Adulto , Animais , Caenorhabditis elegans/metabolismo , Proteínas de Caenorhabditis elegans/metabolismo , Estudos Transversais , Resposta ao Choque Térmico , Humanos , Proteostase
6.
Biophys J ; 115(9): 1817-1825, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30314654

RESUMO

The acoustic compressibility of Caenorhabditis elegans is a necessary parameter for further understanding the underlying physics of acoustic manipulation techniques of this widely used model organism in biological sciences. In this work, numerical simulations were combined with experimental trajectory velocimetry of L1 C. elegans larvae to estimate the acoustic compressibility of C. elegans. A method based on bulk acoustic wave acoustophoresis was used for trajectory velocimetry experiments in a microfluidic channel. The model-based data analysis took into account the different sizes and shapes of L1 C. elegans larvae (255 ± 26 µm in length and 15 ± 2 µm in diameter). Moreover, the top and bottom walls of the microfluidic channel were considered in the hydrodynamic drag coefficient calculations, for both the C. elegans and the calibration particles. The hydrodynamic interaction between the specimen and the channel walls was further minimized by acoustically levitating the C. elegans and the particles to the middle of the measurement channel. Our data suggest an acoustic compressibility κCe of 430 TPa-1 with an uncertainty range of ±20 TPa-1 for C. elegans, a much lower value than what was previously reported for adult C. elegans using static methods. Our estimated compressibility is consistent with the relative volume fraction of lipids and proteins that would mainly make up for the body of C. elegans. This work is a departing point for practical engineering and design criteria for integrated acoustofluidic devices for biological applications.


Assuntos
Acústica/instrumentação , Caenorhabditis elegans , Dispositivos Lab-On-A-Chip , Animais , Fenômenos Biomecânicos , Força Compressiva , Hidrodinâmica
7.
Lab Chip ; 18(12): 1802, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29808900

RESUMO

Correction for 'Long-term C. elegans immobilization enables high resolution developmental studies in vivo' by Simon Berger et al., Lab Chip, 2018, 18, 1359-1368.

8.
Lab Chip ; 18(9): 1359-1368, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29652050

RESUMO

Live-imaging of C. elegans is essential for the study of conserved cellular pathways (e.g. EGFR/Wnt signaling) and morphogenesis in vivo. However, the usefulness of live imaging as a research tool has been severely limited by the need to immobilize worms prior to and during imaging. Conventionally, immobilization is achieved by employing both physical and chemical interventions. These are known to significantly affect many physiological processes, and thus limit our understanding of dynamic developmental processes. Herein we present a novel, easy-to-use microfluidic platform for the long-term immobilization of viable, normally developing C. elegans, compatible with image acquisition at high resolution, thereby overcoming the limitations associated with conventional worm immobilization. The capabilities of the platform are demonstrated through the continuous assessment of anchor cell (AC) invasion and distal tip cell (DTC) migration in larval C. elegans and germ cell apoptosis in adult C. elegans in vivo for the first time.


Assuntos
Caenorhabditis elegans/crescimento & desenvolvimento , Rastreamento de Células/instrumentação , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Animais , Apoptose , Caenorhabditis elegans/citologia , Rastreamento de Células/métodos , Desenho de Equipamento , Células Germinativas/citologia , Larva/citologia , Larva/crescimento & desenvolvimento
9.
Chem Rev ; 118(4): 2042-2079, 2018 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-29420889

RESUMO

Hydrodynamic phenomena are ubiquitous in living organisms and can be used to manipulate cells or emulate physiological microenvironments experienced in vivo. Hydrodynamic effects influence multiple cellular properties and processes, including cell morphology, intracellular processes, cell-cell signaling cascades and reaction kinetics, and play an important role at the single-cell, multicellular, and organ level. Selected hydrodynamic effects can also be leveraged to control mechanical stresses, analyte transport, as well as local temperature within cellular microenvironments. With a better understanding of fluid mechanics at the micrometer-length scale and the advent of microfluidic technologies, a new generation of experimental tools that provide control over cellular microenvironments and emulate physiological conditions with exquisite accuracy is now emerging. Accordingly, we believe that it is timely to assess the concepts underlying hydrodynamic control of cellular microenvironments and their applications and provide some perspective on the future of such tools in in vitro cell-culture models. Generally, we describe the interplay between living cells, hydrodynamic stressors, and fluid flow-induced effects imposed on the cells. This interplay results in a broad range of chemical, biological, and physical phenomena in and around cells. More specifically, we describe and formulate the underlying physics of hydrodynamic phenomena affecting both adhered and suspended cells. Moreover, we provide an overview of representative studies that leverage hydrodynamic effects in the context of single-cell studies within microfluidic systems.


Assuntos
Hidrodinâmica , Adesão Celular , Técnicas de Cultura de Células , Humanos , Modelos Biológicos
10.
Annu Rev Anal Chem (Palo Alto Calif) ; 10(1): 1-24, 2017 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-28375703

RESUMO

Recent years have witnessed an increased use of droplet-based microfluidic techniques in a wide variety of chemical and biological assays. Nevertheless, obtaining dynamic data from these platforms has remained challenging, as this often requires reading the same droplets (possibly thousands of them) multiple times over a wide range of intervals (from milliseconds to hours). In this review, we introduce the elemental techniques for the formation and manipulation of microfluidic droplets, together with the most recent developments in these areas. We then discuss a wide range of analytical methods that have been successfully adapted for analyte detection in droplets. Finally, we highlight a diversity of studies where droplet-based microfluidic strategies have enabled the characterization of dynamic systems that would otherwise have remained unexplorable.


Assuntos
Microfluídica/métodos , Bioensaio/instrumentação , Bioensaio/métodos , Enzimas/química , Enzimas/metabolismo , Cinética , Microfluídica/instrumentação , Ácidos Nucleicos/química , Ácidos Nucleicos/metabolismo , Óleos/química , Espectrometria de Fluorescência , Tensoativos/química
12.
Micromachines (Basel) ; 7(2)2016 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-30407399

RESUMO

Herein, we assess the functionality of magnetic helical microswimmers as basic tools for the manipulation of soft materials, including microdroplets and single cells. Their ability to perform a range of unit operations is evaluated and the operational challenges associated with their use are established. In addition, we also report on interactions observed between the head of such helical swimmers and the boundaries of droplets and cells and discuss the possibilities of assembling an artificial swimming microorganism or a motorized cell.

13.
Analyst ; 140(2): 414-21, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25379571

RESUMO

We present the use of microfluidic "V-junctions" as a droplet generation strategy that incorporates enhanced performance characteristics when compared to more traditional "T-junction" formats. This includes the ability to generate target-sized droplets from the very first one, efficient switching between multiple input samples, the production of a wide range of droplet sizes (and size gradients) and the facile generation of droplets with residence time gradients. Additionally, the use of V-junction droplet generators enables the suspension and subsequent resumption of droplet flows at times defined by the user. The high degree of operational flexibility allows a wide range of droplet sizes, payloads, spacings and generation frequencies to be obtained, which in turn provides for an enhanced design space for droplet-based experimentation. We show that the V-junction retains the simplicity of operation associated with T-junction formats, whilst offering functionalities normally associated with droplet-on-demand technologies.


Assuntos
Hidrodinâmica , Gotículas Lipídicas/química , Microfluídica/instrumentação , Microfluídica/métodos , Óleo Mineral/metabolismo , Dimetilpolisiloxanos/química , Desenho de Equipamento , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos
14.
Nat Chem ; 5(11): 905-15, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24153367

RESUMO

The past two decades have seen far-reaching progress in the development of microfluidic systems for use in the chemical and biological sciences. Here we assess the utility of microfluidic reactor technology as a tool in chemical synthesis in both academic research and industrial applications. We highlight the successes and failures of past research in the field and provide a catalogue of chemistries performed in a microfluidic reactor. We then assess the current roadblocks hindering the widespread use of microfluidic reactors from the perspectives of both synthetic chemistry and industrial application. Finally, we set out seven challenges that we hope will inspire future research in this field.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/tendências , Microfluídica/métodos , Microfluídica/tendências , Animais , Pesquisa Biomédica , Indústria Química , Química Verde , Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/instrumentação , Compostos Orgânicos/síntese química
15.
Lab Chip ; 12(20): 4049-54, 2012 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-22918490

RESUMO

We present a simple technique for the concentration of liquid samples in microfluidic devices applicable for single or multiple-phase configurations. The strategy consists of capturing the sample of interest within microfluidic traps and breaking its continuity by the introduction of a gas phase, which is also used to evaporate it.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos
16.
Chem Commun (Camb) ; 47(35): 9801-3, 2011 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-21818494

RESUMO

We present a passive microfluidic strategy for sorting adult C. elegans nematodes on the basis of age and size. The separation mechanism takes advantage of phenotypic differences between 'adult' and 'juvenile' organisms and their behaviour in microfluidic architectures. In brief, the microfluidic device allows worms to sort themselves in a passive manner.


Assuntos
Envelhecimento , Caenorhabditis elegans/isolamento & purificação , Caenorhabditis elegans/fisiologia , Técnicas Analíticas Microfluídicas/métodos , Animais , Tamanho Corporal , Caenorhabditis elegans/crescimento & desenvolvimento , Fatores de Tempo
17.
Chem Commun (Camb) ; 47(7): 1936-42, 2011 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-20967373

RESUMO

We report recent advances in the field of droplet-based microfluidics. Specifically, we highlight the unique features of such platforms for high-throughput experimentation; describe functional components that afford complex analytical processing and report on applications in synthesis, high-throughput screening, cell biology and synthetic and systems biology. Issues including the integration of high-information content detection methods, long term droplet stability and opportunities for large scale and intelligent biological experimentation are also discussed.

18.
J Vis Exp ; (58)2011 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-22215381

RESUMO

The development of microfluidic platforms for performing chemistry and biology has in large part been driven by a range of potential benefits that accompany system miniaturisation. Advantages include the ability to efficiently process nano- to femoto- liter volumes of sample, facile integration of functional components, an intrinsic predisposition towards large-scale multiplexing, enhanced analytical throughput, improved control and reduced instrumental footprints. In recent years much interest has focussed on the development of droplet-based (or segmented flow) microfluidic systems and their potential as platforms in high-throughput experimentation. Here water-in-oil emulsions are made to spontaneously form in microfluidic channels as a result of capillary instabilities between the two immiscible phases. Importantly, microdroplets of precisely defined volumes and compositions can be generated at frequencies of several kHz. Furthermore, by encapsulating reagents of interest within isolated compartments separated by a continuous immiscible phase, both sample cross-talk and dispersion (diffusion- and Taylor-based) can be eliminated, which leads to minimal cross-contamination and the ability to time analytical processes with great accuracy. Additionally, since there is no contact between the contents of the droplets and the channel walls (which are wetted by the continuous phase) absorption and loss of reagents on the channel walls is prevented. Once droplets of this kind have been generated and processed, it is necessary to extract the required analytical information. In this respect the detection method of choice should be rapid, provide high-sensitivity and low limits of detection, be applicable to a range of molecular species, be non-destructive and be able to be integrated with microfluidic devices in a facile manner. To address this need we have developed a suite of experimental tools and protocols that enable the extraction of large amounts of photophysical information from small-volume environments, and are applicable to the analysis of a wide range of physical, chemical and biological parameters. Herein two examples of these methods are presented and applied to the detection of single cells and the mapping of mixing processes inside picoliter-volume droplets. We report the entire experimental process including microfluidic chip fabrication, the optical setup and the process of droplet generation and detection.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Escherichia coli/química , Técnicas Analíticas Microfluídicas/instrumentação , Espectrometria de Fluorescência/métodos
19.
Anal Chem ; 82(9): 3950-6, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20356052

RESUMO

Microdroplets generated in microfluidic channels hold great promise for use as substrates in high-throughput chemical and biological analysis. These water-in-oil compartments can serve as isolated reaction vessels, and since they can be generated at rates in excess of 1 kHz, thousands of assays can be carried out quickly and reproducibly. Nevertheless, sampling the large amount of information generated from these platforms still remains a significant challenge. For example, considering the high droplet generation rates and velocities, reproducibility and micrometer resolution are challenging requirements that must be fulfilled. Herein we combine confocal fluorescence lifetime imaging microscopy with a statistical implementation that permits the analysis of mixing phenomena within microdroplets with a temporal resolution of 1 mus. Importantly, such exquisite resolution is only possible as a result of the large number of droplets sampled and their high structural reproducibility.


Assuntos
Nanopartículas , Óleos/química , Água/química , Microfluídica/métodos , Microscopia Confocal , Microscopia de Fluorescência , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...