Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Craniofac Surg ; 24(2): 523-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23524732

RESUMO

BACKGROUND: Malignant rhabdoid tumors are rare and aggressive tumors of pediatric age. The primary tumor can occur in different localizations, but it mainly involves kidney, soft tissue, or central nervous system. It has been associated to a poor diagnosis. METHODS: The authors present the case of a 10-day-old newborn affected by a bulky nasofronto-orbitary neoplasm. The patient underwent radical surgical treatment and further excision of a preauricular metastasis combined with postoperative chemotherapy treatment. RESULTS: The authors adopted a diagnostic and therapeutic protocol according to international guidelines, not without difficulty because the first histological report showed esthesioneuroblastoma. The rarity and aggresivity of rhabdoid tumor and the precocity of onset in our patient presented a difficulty to define prognostic factors and survival rates, as well as therapeutic plan of treatment. CONCLUSIONS: The authors underline the importance of a correct prenatal diagnosis and an early surgical treatment to reach the complete healing of the patient.


Assuntos
Neoplasias de Cabeça e Pescoço/cirurgia , Tumor Rabdoide/cirurgia , Neoplasias de Cabeça e Pescoço/diagnóstico , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética , Masculino , Diagnóstico Pré-Natal , Tumor Rabdoide/diagnóstico , Tomografia Computadorizada por Raios X
2.
Eur J Ophthalmol ; 21(3): 251-7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20853257

RESUMO

PURPOSE: The aim of this study was to evaluate the measurement of intraocular pressure (IOP) using a new induction/impact rebound tonometer (ICare®) compared with Goldmann applanation tonometry (GAT). We also aimed to quantify the systematic and random errors (bias) of the 2 methods, to evaluate the sensitivity and specificity of the ICare® tonometer in identifying patients with 21 mmHg or more measured with the GAT, and to study the influence of corneal thickness on IOP measurement with the 2 tonometers. METHODS: We compared the IOP values obtained with the 2 instruments in 97 patients. RESULTS: Analysis based on the Bland and Altman method revealed that the IOP values recorded with the ICare® tonometer were slightly higher than those obtained with the GAT. The estimated bias for right eye measurements was 0.78 mmHg with 95% limits of agreement ±3.55 mmHg. This overestimation, which is not clinically relevant, was confirmed when we used the IOP values corrected according to central corneal thickness for data analysis. The sensitivity and specificity were 0.90 and 0.95, respectively. CONCLUSIONS: The ICare® tonometer proved to be comparable with other nonconventional tonometers and can be used by nonophthalmologists and paramedical personnel during screening tests of populations. In addition, the ICare® tonometer could be considered a valid alternative to GAT when GAT is not available.


Assuntos
Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Eur J Ophthalmol ; 20(3): 625-8, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20099234

RESUMO

PURPOSE: Branch retinal artery occlusion caused by calcific embolization secondary to calcific aortic valvulopathy. METHODS: A 45-year-old woman came to our attention complaining a sudden painless loss of her peripheral superior visual field. Best visual acuity was 20/20. Fundus examination revealed the presence of a retinal arterial embolic occlusion of the inferior branch. Fundus retinography, visual field, and fluorescein angiography were performed and medical therapy was started. The echocardiography examination revealed a tricuspid and calcified aortic valve with moderate stenosis and regurgitation. Due to the heart pathology, the patient moved to the cardiosurgery department, where an aortic valve replacement was performed. RESULTS: Four months after cardiac surgery, visual acuity of both eyes was stable (20/20). Fundus examination showed a complete reabsorption of the retinal edema and the resolution of retinal pallor. Fluorescein angiography confirmed the delay of the arterial filling. No retinal ischemia was observed. The visual field examination confirmed the deep scotoma previously registered. CONCLUSIONS: Retinal arterial embolization is a rare but potentially devastating complication of calcific aortic stenosis. Initial retinal presentation of calcific aortic stenosis is a rare condition. Keeping in mind that these emboli may be recurrent and potentially bilateral, a sudden onset of visual field defects, especially in young asymptomatic patients, needs immediate diagnosis and consideration of an urgent surgical correction.


Assuntos
Estenose da Valva Aórtica/complicações , Calcinose/complicações , Embolia/etiologia , Oclusão da Artéria Retiniana/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Ecocardiografia , Ecocardiografia Doppler , Embolia/diagnóstico por imagem , Embolia/cirurgia , Feminino , Angiofluoresceinografia , Humanos , Pessoa de Meia-Idade , Oclusão da Artéria Retiniana/diagnóstico , Transtornos da Visão/etiologia , Testes de Campo Visual , Campos Visuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...