Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Opt Soc Am A Opt Image Sci Vis ; 34(4): 576-582, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28375327

RESUMO

Non-paraxial perturbation wave equations are solved for general astigmatic Gaussian beams for the first time, to the best of our knowledge, in the angular spectrum representation by taking into account generic boundary conditions. Expressions for second-order corrections are derived and exemplified with an optical cavity made of two cylindrical mirrors. Non-paraxial corrections can lead, depending on the choice of boundary conditions, to a transverse S-shaped beam mode, which has been qualitatively been observed in a highly divergent non-planar four-mirror cavity.

2.
Sci Rep ; 6: 36569, 2016 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-27857146

RESUMO

We report and discuss high-flux generation of circularly polarized γ-rays by means of Compton scattering. The γ-ray beam results from the collision of an external-cavity-enhanced infrared laser beam and a low emittance relativistic electron beam. By operating a non-planar bow-tie high-finesse optical Fabry-Perot cavity coupled to a storage ring, we have recorded a flux of up to (3.5 ± 0.3) × 108 photons per second with a mean measured energy of 24 MeV. The γ-ray flux has been sustained for several hours. In particular, we were able to measure a record value of up to 400 γ-rays per collision in a full bandwidth. Moreover, the impact of Compton scattering on the electron beam dynamics could be observed resulting in a reduction of the electron beam lifetime correlated to the laser power stored in the Fabry-Perot cavity. We demonstrate that the electron beam lifetime provides an independent and consistent determination of the γ-ray flux. Furthermore, a reduction of the γ-ray flux due to intrabeam scattering has clearly been identified. These results, obtained on an accelerator test facility, warrant potential scaling and revealed both expected and yet unobserved effects. They set the baseline for further scaling of the future Compton sources under development around the world.

3.
Opt Lett ; 40(20): 4775-8, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26469617

RESUMO

Harmonic seeded operation of a neon-like titanium plasma-based soft x-ray laser is described. The plasma amplifier is pumped with a variation of the grazing incidence technique involving a fast and localized ionization step. We discuss its effect on gain dynamics by measuring the amplifying factor as a function of the delay between pump pulse and harmonic seed. Two different regimes are pointed out, following the pumping scheme used. For one of them, a delay in the gain generation compared with the pumping laser pulse is observed.

4.
Opt Express ; 20(23): 25391-9, 2012 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-23187356

RESUMO

Experimental results of a two-stage Ni-like Ag soft X-ray laser operated in a seed-amplifier configuration are presented. Both targets were pumped applying the double-pulse grazing incidence technique with intrinsic travelling wave excitation. The injection of the seed X-ray laser into the amplifier target was realized by a spherical mirror. The results show amplification of the seed X-ray laser and allow for a direct measurement of the gain lifetime. The experimental configuration is suitable for providing valuable input for computational simulations.

5.
Phys Rev E Stat Nonlin Soft Matter Phys ; 86(2 Pt 2): 026406, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23005868

RESUMO

The accurate characterization of thermal electron transport and the determination of heating by suprathermal electrons in laser driven solid targets are both issues of great importance to the current experiments being performed at the National Ignition Facility, which aims to achieve thermonuclear fusion ignition using lasers. Ionization, induced by electronic heat conduction, can cause the opacity of a material to drop significantly once bound-free photoionization is no longer energetically possible. We show that this drop in opacity enables measurements of the transmission of extreme ultraviolet (EUV) laser pulses at 13.9 nm to act as a signature of the heating of thin (50 nm) iron layers with a 50-nm thick parylene-N (CH) overlay irradiated by 35-fs pulses at irradiance 3×10(16) Wcm(-2). Comparing EUV transmission measurements at different times after irradiation to fluid code simulations shows that the target is instantaneously heated by hot electrons (with approximately 10% of the laser energy), followed by thermal conduction with a flux limiter of ≈0.05.

6.
Opt Lett ; 35(9): 1326-8, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20436557

RESUMO

We present what we believe to be the first measurement of the spectral properties of a soft x-ray laser seeded by a high-order harmonic beam. Using an interferometric method, the spectral profile of a seeded Ni-like krypton soft x-ray laser (32.8 nm) generated by optical field ionization has been experimentally determined, and the shortest possible pulse duration has been deduced. The source exhibits a Voigt spectral profile with an FWHM of 3.1+/-0.3 mA, leading to a Fourier-transform pulse duration of 4.7 ps. This value is comparable with the upper limit of the soft x-ray pulse duration determined by experimentally investigating the gain dynamics, from which we conclude that the source has reached the Fourier limit. The measured bandwidth is in good agreement with the predictions of a radiative transfer code, including gain line narrowing and saturation rebroadening.

7.
Opt Lett ; 34(17): 2640-2, 2009 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-19724517

RESUMO

Plasma-based seeded soft x-ray lasers have the potential to generate a high-energy, highly coherent, short pulse beam. Owing to their high density, plasmas created by interaction of an intense laser with a solid target should store the highest amount of energy among all plasma amplifiers. However, to date output energy from seeded solid amplifiers remains as low as 60 nJ. We demonstrated that careful tailoring of the plasma shape is crucial for extracting energy stored in the plasma. With 1-mm-wide plasma, energy as high as 20 microJ in sub-ps pulses is achievable. With such tailored plasma, gain and pumping efficiency have been increased by nearly a factor of 10 as compared to the narrower plasma amplifiers studied here.

8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 80(6 Pt 2): 066403, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20365282

RESUMO

The excitation of plasma waves over a length of up to 8 cm is demonstrated using laser guiding of intense laser pulses through hydrogen-filled glass capillary tubes. The plasma waves are diagnosed by spectral analysis of the transmitted laser radiation. The dependence of the spectral redshift-measured as a function of filling pressure, capillary tube length, and incident laser energy-is in excellent agreement with simulation results. The longitudinal accelerating field inferred from the simulations is in the range of 1-10 GV/m.

9.
Opt Lett ; 32(2): 139-41, 2007 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-17186043

RESUMO

We report the near-field imaging characterization of a 10 Hz Ni-like 18.9 nm molybdenum soft-x-ray laser pumped in a grazing incidence pumping (GRIP) geometry with a table-top laser driver. We investigate the effect of varying the GRIP angle on the spatial behavior of the soft-x-ray laser source. After multiparameter optimization, we were able to find conditions to generate routinely a high-repetition-rate soft-x-ray laser with an energy level of up to 3 microJ/pulse and to 6x10(17) photons/s/mm2/mrad2/(0.1% bandwidth) average brightness and 1x10(28) photons/s/mm2/mrad2/(0.1% bandwidth) peak brightness.

10.
Opt Express ; 15(15): 9486-93, 2007 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-19547296

RESUMO

A soft x-ray laser from Ni-like Mo, pumped in grazing incidence (GRIP), is analyzed with regard to high repetition rate operation. Reliable lasing is obtained, but with significant energy fluctuations attributed mainly to beam pointing jitter from the pump laser. Two modes of operation are compared: continuously moving target and stationary target. With a moving target the soft X-ray output is constant on average, whereas the repeated use of the same target position leads to a pulse energy which increases for several tens of shots. This effect might be caused by improved guiding of the pump laser in the formed groove and the removal, through laser ablation, of the oxide layer on the target surface.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA