Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Nutrients ; 16(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38337645

RESUMO

This systematic review and meta-analyses aimed to assess whether malnutrition may increase the incidence of oral cancer. Following the PRISMA statement, the research was conducted on PubMed, Scopus, and MEDLINE via OVID without any time restrictions. The risk of bias was assessed, and the quality of evidence for each performed meta-analysis was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. Sixty-one articles met the inclusion criteria and seven studies underwent quantitative evaluation. For our meta-analysis on hypovitaminosis B, three studies with a total of 90,011 patients were included. An odds ratio of 2.22 was found. Our meta-analysis on the correlation between vitamin C and oral cancer included one study with a total of 866 patients and the derived odds ratio was 1.06. Our meta-analysis on the relationship between vitamin D deficiency and the incidence of oral cancer included three studies with a total of 12,087 patients and the odds ratio was -2.58. The GRADE system showed a moderate strength of evidence due to the presence of studies with a high risk of bias and high indirectness of the data given. The present findings suggest that an inadequate intake of vitamins, particularly vitamin D, poses a risk for the onset of oral cancer.


Assuntos
Desnutrição , Neoplasias Bucais , Humanos , Neoplasias Bucais/epidemiologia , Neoplasias Bucais/etiologia , Desnutrição/complicações , Desnutrição/epidemiologia , Fatores de Risco , Vitaminas , Vitamina D
2.
Eur Endod J ; 9(1): 81-88, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37965676

RESUMO

OBJECTIVE: The aim of this in vitro study was to compare the smear layer and debris removal and antimicrobial activity of two dual-action irrigating solutions for continuous chelation (Triton; Brasseler, Savannah, USA and Dual Rinse HEDP; Medcem GmbH, Weinfelden, Switzerland) with a dual step irrigation protocol with sodium hypochlorite (NaOCl) followed by ethylenediaminetetraacetic acid (EDTA). METHODS: Thirty single-rooted single-canal teeth were divided into three groups (n=10) and irrigated with Triton, Dual Rinse HEDP mixed with 6% NaOCl and 6% NaOCl/17% EDTA. The teeth were observed under a scanning electron microscope (SEM) to assess the canal wall cleanliness. In addition, 80 dentine discs were contaminated with Candida albicans and 80 discs with Enterococcus faecalis and irrigated with Triton, Dual Rinse HEDP mixed with 6% NaOCl and 6% NaOCl/17% EDTA or not treated (n=20). Fifteen discs were used to evaluate colony-forming units, while 5 discs were analysed by SEM. Data were analysed using the Shapiro- Wilk, Kruskal-Wallis and One-Way ANOVA tests. RESULTS: Triton was statistically more effective than Dual Rinse HEDP and NaOCl/EDTA in removing debris (p<0.05), except with NaOCl/EDTA in the coronal third. Triton was more effective than Dual Rinse HEDP in removing the smear layer from the apical and middle thirds (p<0.05). All the irrigation protocols significantly re- duced the number of E. faecalis. The Triton group showed the lowest number of remaining C. albicans (p<0.05). CONCLUSION: Triton was the most effective irrigation solution in removing debris and as effective as NaOCl/ EDTA in removing the smear layer. Triton showed the highest efficacy against C. albicans. New irrigating solutions that provide continuous chelation may provide an alternative to current irrigation protocols.


Assuntos
Anti-Infecciosos , Camada de Esfregaço , Humanos , Ácido Edético/farmacologia , Ácido Etidrônico , Microscopia Eletrônica de Varredura , Cavidade Pulpar , Preparo de Canal Radicular/métodos , Irrigantes do Canal Radicular/farmacologia , Quelantes/farmacologia , Anti-Infecciosos/farmacologia
3.
BMC Oral Health ; 23(1): 357, 2023 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-37270480

RESUMO

INTRODUCTION: The aim of this case series was to evaluate the necrosis of teeth adjacent to the site of mandibulotomy or mandibulectomy in a cohort of patients suffering from head and neck cancers. METHODS: Fourteen patients who underwent segmental mandibulectomy or paramedian mandibulotomy for oral, oropharynx or major salivary gland cancer and a total of 23 teeth were included in this case series. Twelve patients underwent adjuvant head and neck radiotherapy. Cold sensitivity pulp testing and/or electric pulp testing were performed on teeth at the margin of mandibulectomy and on teeth adjacent to mandibulotomy after surgery. A "positive" response was considered the healthy state, and "negative" was considered the diseased state of the tooth. RESULTS: The 10 patients who underwent mandibulotomy had 12 teeth with a negative response. The 4 patients treated by mandibulectomy had two positive and three negative responses to cold and electric pulp tests. Fifteen out of 23 teeth (65.2%) showed a negative response to sensitivity testing. CONCLUSIONS: Tooth necrosis seems to be a common event after mandibulectomy and mandibulotomy. CLINICAL RELEVANCE: To avoid post-surgery complications, performing root canal therapy before surgery on the teeth adjacent to the surgical site could be an appropriate strategy.


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Humanos , Osteotomia Mandibular , Neoplasias Bucais/cirurgia , Neoplasias de Cabeça e Pescoço/cirurgia , Complicações Pós-Operatórias , Necrose
4.
Pharmaceutics ; 15(5)2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37242801

RESUMO

Due to its numerous advantages, such as excellent drug accessibility, rapid absorption, and bypass of first-pass metabolism, the route of drug administration that involves crossing the oral mucosa is highly favored. As a result, there is significant interest in investigating the permeability of drugs through this region. The purpose of this review is to describe the various ex vivo and in vitro models used to study the permeability of conveyed and non-conveyed drugs through the oral mucosa, with a focus on the most effective models. Currently, there is a growing need for standardized models of this mucosa that can be used for developing new drug delivery systems. Oral Mucosa Equivalents (OMEs) may provide a promising future perspective as they are capable of overcoming limitations present in many existing models.

5.
Restor Dent Endod ; 47(1): e3, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36578274

RESUMO

Objectives: This study aimed to assess the impact of a glide-path on the shaping ability of 2 single-file instruments and to compare the centering ability, maintenance of original canal curvatures and area of instrumentation in simulated S-shaped root canals. Materials and Methods: Forty simulated S-shaped root canals were used and were prepared with One Curve (group OC), One G and OC (group GOC), Reciproc Blue (group RB) and R-Pilot and RB (group PRB) and scanned before and after instrumentation. The images were analyzed using AutoCAD. After superimposing the samples, 4 levels (D1, D2, D3, and D4) and 2 angles (Δ1 and Δ2) were established to evaluate the centering ability and modification of the canal curvatures. Then, the area of instrumentation (ΔA) was measured. The data were analyzed using 2-way analysis of variance and Tukey's test for multiple comparisons (p < 0.05). Results: Regarding the centering ability in the apical part (D3, D4), the use of the glide-path yielded better results than the single-file groups. Among the groups at D4, OC showed the worst results (p < 0.05). The OC system removed less material (ΔA) than the RB system, and for Δ1, OC yielded a worse result than RB (p < 0.05). Conclusions: The glide-path improved the centering ability in the apical part of the simulated S-shaped canals. The RB system showed a better centering ability in the apical part and major respect of the canal curvatures compared with OC system.

6.
Biomed Res Int ; 2022: 5100816, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36440368

RESUMO

The aim of this study was to analyse the cytocompatibility of Surefil One (SuO) with respect to the release of monomers from the material. The following reference materials were chosen: SDR Flow Plus (SDR, Dentsply Sirona, Konstanz, Germany), One Q Bond (Q, Dentalica, Milan, Italy), and Ketac (K, 3M-ESPE, USA). Fifteen dentin discs (2 mm thickness and diameter) were obtained from 15 third molars and were used in this study. After dentin disc permeability measurement, murine fibroblasts were grown, and the pulp surface of the dentinal disc was placed in direct contact with the cells immersed in DMEM. The experimental materials were positioned on the occlusal side of each dentinal disc until a uniform thickness of 2 mm was obtained. Then, the discs were inserted into an artificial pulp chamber for 24 hours to assess the cytocompatibility. Afterwards, the moles of monomers leached from the specimens in DMEM were determined using HPLC. Statistical analysis was performed using ANOVA (p < 0.05). Under the experimental conditions, the toxic effect induced by all tested materials was slight or absent. Diurethane dimethacrylate and acrylic acid were not found in the culture media. It is concluded that all materials have good cytocompatibility consistent with the nondeterminability of the monomers released after polymerization.


Assuntos
Resinas Compostas , Cavidade Pulpar , Camundongos , Animais , Resinas Compostas/química , Dentina , Alemanha , Itália
7.
Minerva Dent Oral Sci ; 70(5): 214-222, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33988331

RESUMO

Dental caries is one of the most common diseases in the world, and global incidence rates are increasing. The early detection of dental lesions enables a conservative approach to be employed and represents a priority in modern dentistry. Recent studies have suggested that conventional diagnostic methods, such as visual tactile inspection and X-ray examination, exhibit low sensitivity and are not very effective in early diagnoses. Consequently, late detection of decay is associated with an increased loss of tooth structure. New diagnostic systems based on optical properties have been developed to facilitate early detection. Several studies have evaluated the performance of near-infrared imaging (NIRI) as an early diagnostic tool. NIRI using light ranging from 700 to 1700 nm has demonstrated better optical properties compared to conventional optical systems using light in the visible spectra. NIRI enables deeper penetration of the light in the tooth tissue, weak scattering with lower background noise and strong photon absorption with detailed images. Several in-vivo studies have demonstrated that NIRI technology has the potential to improve performance compared with current diagnostic methods. NIRI exhibits increased sensitivity compared to radiographs and is more suitable to identify approximal enamel lesions. This paper aimed to review these recent advances and their potential applications in daily clinical practice.


Assuntos
Cárie Dentária , Dente , Cárie Dentária/diagnóstico , Esmalte Dentário/diagnóstico por imagem , Humanos , Exame Físico , Raios X
8.
Antibiotics (Basel) ; 9(10)2020 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-33066198

RESUMO

The aim of this study was to evaluate the antibacterial properties of graphene oxide (GO) against Enterococcus faecalis in vitro conditions and when used to coat dentin surface to prevent E. faecalis adhesion. The ATCC strain of E. faecalis 29212 has been used to perform a viability test. The pellet was suspended in ultrapure water, NaCl, PBS buffer, CaCl2 and MgCl2, Luria-Bertani broth solutions. The viability was evaluated by the colony forming unit counting method. Atomic force microscopy images and the measure of surface zeta potential variation were analyzed. Dentin discs were covered with a film of GO (n = 15) or were not treated (n = 15). Bacterial suspension was added to each sample of dentine discs and microbial counts were calculated. Statistically significant differences between two groups were assessed by a two-tailed unpaired t-test. Bacteria cell morphology was investigated with scanning electron microscopy. The highest growth inhibition was obtained in ddH2O and CaCl2 solution while, in PBS and NaCl, GO had poor antibacterial efficacy with a growth enhancing effect in the latter. GO on dentin discs demonstrated high antibacterial activity. GO film has demonstrated acceptable adhesion properties to root dentin and a role in the inhibition of bacterial film proliferation and biofilm formation.

9.
J Endod ; 46(4): 551-556, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32088010

RESUMO

Osteoradionecrosis (ORN) of the jaw is considered the most severe long-term adverse effect that can occur in radiation therapy patients. Teeth extractions and dental diseases are the main risk factors for ORN in irradiated patients. The aim of this case series was to evaluate the outcome of primary root canal treatments performed on patients who underwent head and neck radiotherapy and to evaluate any ORN related to the endodontic treatment. In this case series, primary root canal therapies (absence of radiolucency) were performed on 10 teeth of 8 patients who underwent radiotherapy for head and neck cancers. Radiation doses to the periapical area were calculated using the radiotherapy planning computed tomographic scan. After a 277-day mean follow-up, all patients were asymptomatic, no teeth showed periapical radiolucency, and no ORN was observed. Even if a limitation of buccal opening occurred after radiotherapy and complicated the endodontic procedures, root canal therapy seemed to be safe and a valid alternative to tooth extraction.


Assuntos
Neoplasias de Cabeça e Pescoço , Osteorradionecrose , Cavidade Pulpar , Humanos , Tratamento do Canal Radicular , Extração Dentária , Resultado do Tratamento
10.
Antibiotics (Basel) ; 8(3)2019 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-31405049

RESUMO

The microbial infection of the endodontic space occurs in a necrotic tooth as a result of dental caries, trauma, periodontal disease, or previous root canal therapy. The disruption of the biofilms and the reduction of the bacterial load inside root canals are crucial for the success of root canal therapy. The aim of this study was to compare, in vitro, the antibiofilm efficacy of a novel passive sonic irrigation (PSI) device with passive ultrasonic irrigation (PUI) and conventional needle irrigation (CNI). Forty-four single-rooted human teeth were inoculated with a culture of E. faecalis for 28 days. The specimens were randomly divided into three groups: PUI, CNI, and PSI (n = 12). The activation protocols were performed using both 17% EDTA and 5.25% NaOCl. Residual bacterial biofilm was taken by means of a canal brush and colony-forming unit (CFU) were counted. The data were analyzed using one-way ANOVA and Games-Howell's post hoc tests. A major reduction in CFU was observed in the PSI and PUI groups, in comparison with the CNI group. No difference was found (p > 0.05) in terms of CFU reduction between PSI and PUI. PSI could be as effective as PUI in the removal of bacterial biofilms from straight root canals.

11.
Biomed Res Int ; 2019: 4240264, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31211136

RESUMO

The aim of this study was to evaluate the effect of light-curing protocols on two modern resin composites using different air-inhibition coating strategies. This was accomplished by assessing the amount of monomer elution, surface microhardness, and composite discoloration in different storage conditions. A total of 120 specimens were prepared using Filtek Supreme XTE (3M ESPE, Seefeld, Germany) and CeramX Universal (Dentsply DeTrey, Konstanz, Germany). Specimens were light-cured in air as per manufacturer's instructions or in the absence of oxygen. This latter condition was achieved using three different approaches: (i) transparent polyester strip; (ii) glycerin; (iii) argon gas. Specimens were assessed for release of monomers, Vickers hardness, and discoloration after storage in different solutions. The results were analyzed with ANOVA one-way test followed by Student-Newman-Keuls test. Moreover, multiple comparisons of means were performed using the Student t-test (p<0.05). The amount of monomers released from the tested specimens was very low in all conditions. The presence of oxygen induced some decrease in microhardness. The highest discoloration values, for both materials, were obtained after ageing in red wine. In case finish and polish procedures are awkward to achieve in posteriors composite restoration, light-curing in the absence of oxygen should be considered, especially when performing composite restoration in esthetic areas.


Assuntos
Cor , Resinas Compostas/química , Teste de Materiais , Dureza , Humanos , Propriedades de Superfície
12.
J Endod ; 44(10): 1549-1552, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30144990

RESUMO

INTRODUCTION: The aim of the present study was to investigate the impact of ambient temperature on the life span of nickel-titanium (NiTi) files. METHODS: Cyclic fatigue testing of NiTi instruments was performed in a stainless steel artificial canal. During the experiment, 4 different temperatures (0°C, 20°C, 35°C, and 39°C) were used in a thermostatic bath controlled using electronic and infrared controls. Eighty R25 Reciproc Blue (VDW, Munich, Germany) and 80 R25 Reciproc (VDW) instruments were reciprocated in the artificial canal until fracture occurred, and the time to fracture and the length of the fractured fragment were recorded. The phase transformation temperature for 3 instruments of each type was analyzed by differential scanning calorimetry. One-way analysis of variance and Bonferroni tests were used to statistically analyze the data at a 5% significance level (P < .05). RESULTS: Reciproc Blue instruments were significantly more resistant to cyclic fatigue than Reciproc at all the temperatures tested (P < .05). Fatigue resistance was proportionally higher as the environmental temperature decreased (0°C > 20°C > 35°C > 39°C). No significant difference was registered for the length of the fractured fragment of both instruments tested at all temperatures tested (P > .05). CONCLUSIONS: Blue alloy significantly increases the cyclic fatigue resistance of Reciproc files compared with M-Wire alloy. Temperature significantly affects the life span of NiTi files. When the ambient temperature increases between 0°C and 35°C, the fatigue resistance of the files statistically decreases.


Assuntos
Ligas , Instrumentos Odontológicos , Falha de Equipamento , Preparo de Canal Radicular/instrumentação , Temperatura , Varredura Diferencial de Calorimetria , Teste de Materiais , Estresse Mecânico
13.
Photomed Laser Surg ; 35(4): 190-194, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28068207

RESUMO

OBJECTIVE: This study examined the bactericidal effect of diode laser irradiation against intracanal Enterococcus faecalis. METHODS AND MATERIALS: m total of 128 extracted single-rooted and single-canal teeth were treated with ProTaper instruments (Dentsply Maillefer, Ballaigues, Switzerland). A total of 120 root canals were inoculated with E. faecalis for 21 days, and the samples were randomly divided into five groups: Group 1 (n = 24) samples were irrigated with only saline solution (positive controls); Group 2 (n = 24) was treated with only 5.25% sodium hypochlorite; Group 3 (n = 24) was irrigated with saline solutions activated by diode laser; Group 4 (n = 24) was treated with 5.25% sodium hypochlorite activated by diode laser; and Group 5 (n = 24) was irrigated with saline solution with methylene blue dye activated by the diode laser Fox (Sweden & Martina, Padova, Italy); additionally, eight teeth were not contaminated and their canals were irrigated with saline solution and used as a negative control. The Uro-Quick system was used to determine the microbial residual charge. The data were analyzed using Pearson's chi-square test (p < 0.001). RESULTS: A statistically significant reduction in bacterial count was observed in Group 2 and Group 4 (p < 0.001). There were no statistically significant differences among the other groups (p > 0.001). CONCLUSIONS: Evidence indicates that the diode laser was not more effective than sodium hypochlorite in reducing free bacteria.


Assuntos
Cavidade Pulpar/microbiologia , Cavidade Pulpar/efeitos da radiação , Enterococcus faecalis/patogenicidade , Infecções por Bactérias Gram-Positivas/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Hipoclorito de Sódio/farmacologia , Carga Bacteriana/efeitos da radiação , Enterococcus faecalis/efeitos dos fármacos , Humanos , Técnicas In Vitro , Lasers Semicondutores/uso terapêutico , Valores de Referência , Tratamento do Canal Radicular/métodos , Sensibilidade e Especificidade , Extração Dentária
14.
Clin Oral Investig ; 20(7): 1547-50, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26531192

RESUMO

OBJECTIVE: The aim of this study on human cadavers was to compare the accuracy of two electronic apex locators (EALs) Dentaport ZX (J. Morita Corporation, Tokyo, Japan) and Raypex 6 (VDW, Munich, Germany). MATERIALS AND METHODS: Twenty-two single rooted teeth of four human cadaver heads were scheduled for this study. Before the extraction, an access cavity was opened and the crown was cut to establish a stable reference point for all measurements. The working length determination was performed with Dentaport ZX and Raypex 6 in the presence or not of 5.25 % sodium hypochlorite (SH) using a k-file 10. The teeth were then extracted and the real working length (RWL) was measured under a stereomicroscope at ×30 magnification. The difference between the two working lengths was calculated: positive values indicate measurements exceeding the foramen, while negative values indicated measurements short of the foramen. The data were analyzed with a t test analysis. RESULTS: The mean of distances was 0.33 ± 0.20 mm and 0.32 ± 0.2 mm for Dentaport ZX respectively in the presence or not of SH and 0.38 ± 0.20 mm and 0.39 ± 0.19 mm for Raypex 6. No statistical differences were found between the two devices (p > 0.05). CONCLUSIONS: Both apex locators showed a high accuracy in the presence or not of SH. CLINICAL RELEVANCE: Both electronic apex locators can be recommended for clinical use and their accuracy is not affected by SH.


Assuntos
Odontometria/instrumentação , Tratamento do Canal Radicular/instrumentação , Ápice Dentário/anatomia & histologia , Cadáver , Humanos , Irrigantes do Canal Radicular/química , Hipoclorito de Sódio/química , Propriedades de Superfície
15.
Dent Mater J ; 31(6): 988-94, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23207205

RESUMO

The aim of this study was to perform a morphometric evaluation of the resin-root canal dentine interface of four "etch and rinse" adhesive systems. Forty human teeth were restored through a fiber post insertion using: Group 1: XP Bond adhesive; Group 2: Prime & Bond NT; Group 3: Surgi Prime Bond adhesive; Group 4: Scotchbond Multi-Purpose Plus. Two cross-sections (apical and coronal) were obtained and analyzed in morphological confocal laser scanning microscope. The numbers of resin tags (RT) and the thickness of the hybrid layer (HL) were evaluated. Quantitative variables were tested by a Shapiro-Wilk test. Parametric variables by an Anova test. Group 4 produced the thickest HL and Group 1 showed the thinnest. Considering RT, Group 1 produced the highest density, while Group 3 the lowest density. All the adhesives produced good results in terms of HL thickness and RT density.


Assuntos
Resinas Acrílicas , Colagem Dentária , Adesivos Dentinários , Técnica para Retentor Intrarradicular , Análise de Variância , Humanos , Microscopia Confocal , Ácidos Polimetacrílicos , Cimentos de Resina , Tratamento do Canal Radicular , Estatísticas não Paramétricas
16.
Am J Dent ; 24(1): 25-30, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21469403

RESUMO

PURPOSE: To evaluate the bond strength of resin dentin interfaces created with adhesives applied on root dentin using the water wet or ethanol wet bonding technique. The morphology of resin dentin interfaces was evaluated using confocal microscopy. METHODS: Four experimental resin adhesives (R#A to R#D) and one commercial three-step/etch and rinse adhesive were applied to the root canal dentin of endodontically treated single canal incisors using the water (control) or ethanol wet bonding technique. The ethanol wet bonding substrate was achieved by keeping the root canal immersed in absolute ethanol (100%) for 3 minutes. The root dentin bonded specimens were sectioned into beams, stored in distilled water (24 hours) and finally tested for microtensile bond strengths (tTBS). Additional dentin surfaces were conditioned and bonded as previously described. They were prepared for the microscopy study and finally observed using confocal microscopy. RESULTS: The ethanol wet bonding technique gave higher bond strength values for all the adhesives tested: in Group 1 (water wet bonding technique) no significant difference was found between the resins tested; the only exception being the most hydrophilic Resin #4 showing the highest bond strength values (P < 0.05). In Group 2 (ethanol wet bonding technique) no statistical differences were present between Resin #A and Resin #D. Resin #C showed the highest bond strength values. Confocal microscopy showed better resin diffusion and hybrid layer formation when the ethanol wet bonding was used.


Assuntos
Resinas Compostas , Colagem Dentária/métodos , Cavidade Pulpar , Dentina , Cimentos de Resina/química , Análise de Variância , Análise do Estresse Dentário , Permeabilidade da Dentina , Etanol , Humanos , Interações Hidrofóbicas e Hidrofílicas , Incisivo , Teste de Materiais , Microscopia Confocal , Resistência à Tração , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...