1.
J Radiol Prot ; 40(1): 134-150, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31569086

RESUMO

The results obtained in a measurement campaign concerning internal contamination by the gamma-emitting radionuclides of a large number of individuals are presented in this work. The aim is to assess the effectiveness of the spectrometric method in an emergency response following a nuclear power plant accident or a spread of radionuclides in the atmosphere due to an act of terrorism. An HPGe portable spectrometer, deployed in a collective protection apparatus, was used for both whole-body and thyroid measurements. An adult bottle mannequin absorption (BOMAB) and thyroid phantoms were used to evaluate the detector performance. The BOMAB phantom was provided by the Italian Institute of Ionizing Radiation Metrology (INMRI) for the ENEA intercomparison exercise. Thyroid phantoms were provided by the Belgian Nuclear Research Centre for the 'Child and Adult Thyroid Monitoring After Reactor Accident' European intercomparison exercise. The instrument performance was further evaluated by collecting spectral data from healthy volunteers, using acquisition times of 180 s and 100 s, respectively, for the whole-body and thyroid measurements. The detector showed good accuracy in quantifying radionuclide activities in the adult BOMAB and in the thyroids of persons of all ages. The proposed method allows us to detect in vivo activity leading to a committed effective dose E(50) and committed thyroid equivalent doses H T greater than 2 mSv due to all gamma-emitting fission products, if the scan is performed within five days after intake. Assuming, for instance, an acute inhalation of 137Cs and 131I, the obtained detection limit values for adults lead to a E(50) value equal to 0.08 mSv and an H T value of 0.27 mSv. The E(50) and H T values show that the proposed method can be successfully used when the dose assessment must be rapidly performed for a large number of individuals in the eventuality of the scenarios previously mentioned.


Assuntos
Exposição à Radiação/análise , Monitoramento de Radiação/instrumentação , Liberação Nociva de Radioativos , Glândula Tireoide/efeitos da radiação , Contagem Corporal Total/instrumentação , Radioisótopos de Césio/análise , Humanos , Radioisótopos do Iodo/análise , Manequins , Terrorismo
3.
J Radiol Prot ; 38(4): 1454-1468, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30398166

RESUMO

In order to properly respond to an emergency caused by an accident in a nuclear power plant with a spread of radionuclides in the atmosphere, we propose a field procedure to perform a large-scale individual thyroid monitoring of internal contamination due to inhalation of 131I, by means of non-spectrometric equipment, in particular dose rate meters. Specific attention is paid to the individual monitoring of children, because of the very high radiosensitivity of the child's thyroid to the carcinogenic effects of ionising radiation. The device performance was evaluated by measuring mock iodine sources provided in the Child and Adult Thyroid Monitoring After Reactor Accident (CAThyMARA) intercomparison and, just for a scintillator dose rate meter, by means of 60 s acquisitions of healthy volunteers' thyroids. All the devices showed a remarkable accuracy in quantification of equivalent 131I activity in the thyroids of persons of all ages. The selected scintillator dose rate meter showed detection limit values resulting in a maximum committed equivalent dose to thyroid HT, assuming an acute 131I inhalation occurred five days before the measurement, equal to 10 mSv (related to five-year-old children). Considering the level of HT values associated with the calculated detection limit activities, the proposed procedure has a significant sensitivity to be used for fast internally thyroid monitoring in nuclear or radiological emergencies, allowing daily monitoring a large amount of individuals.


Assuntos
Radioisótopos do Iodo/análise , Monitoramento de Radiação/instrumentação , Liberação Nociva de Radioativos , Glândula Tireoide/efeitos da radiação , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitoramento de Radiação/métodos
4.
Ann ICRP ; 47(3-4): 75-82, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29664321

RESUMO

European Radiation Dosimetry Group (EURADOS) Working Group 7 is a network on internal dosimetry that brings together researchers from more than 60 institutions in 21 countries. The work of the group is organised into task groups that focus on different aspects, such as development and implementation of biokinetic models (e.g. for diethylenetriamine penta-acetic acid decorporation therapy), individual monitoring and the dose assessment process, Monte Carlo simulations for internal dosimetry, uncertainties in internal dosimetry, and internal microdosimetry. Several intercomparison exercises and training courses have been organised. The IDEAS guidelines, which describe - based on the International Commission on Radiological Protection's (ICRP) biokinetic models and dose coefficients - a structured approach to the assessment of internal doses from monitoring data, are maintained and updated by the group. In addition, Technical Recommendations for Monitoring Individuals for Occupational Intakes of Radionuclides have been elaborated on behalf of the European Commission, DG-ENER (TECHREC Project, 2014-2016, coordinated by EURADOS). Quality assurance of the ICRP biokinetic models by calculation of retention and excretion functions for different scenarios has been performed and feedback was provided to ICRP. An uncertainty study of the recent caesium biokinetic model quantified the overall uncertainties, and identified the sensitive parameters of the model. A report with guidance on the application of ICRP biokinetic models and dose coefficients is being drafted at present. These and other examples of the group's activities, which complement the work of ICRP, are presented.


Assuntos
Proteção Radiológica/normas , Radiometria/normas , Humanos , Agências Internacionais , Exposição Ocupacional/prevenção & controle , Monitoramento de Radiação/normas
5.
Radiat Prot Dosimetry ; 170(1-4): 17-20, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26541189

RESUMO

Dose assessment after intakes of radionuclides requires application of biokinetic and dosimetric models and assumptions about factors influencing the final result. In 2006, a document giving guidance for such assessment was published, commonly referred to as the IDEAS Guidelines. Following its publication, a working group within the European networks CONRAD and EURADOS was established to improve and update the IDEAS Guidelines. This work resulted in Version 2 of the IDEAS Guidelines, which was published in 2013 in the form of a EURADOS report. The general structure of the original document was maintained; however, new procedures were included, e.g. the direct dose assessment method for (3)H or special procedure for wound cases applying the NCRP wound model. In addition, information was updated and expanded, e.g. data on dietary excretion of U, Th, Ra and Po for urine and faeces or typical and achievable values for detection limits for different bioassay measurement techniques.


Assuntos
Exposição Ocupacional/análise , Exposição Ocupacional/normas , Doses de Radiação , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/normas , Bioensaio , Europa (Continente) , Fezes , Alemanha , Guias como Assunto , Humanos , Polônio/análise , Radioisótopos/análise , Rádio (Elemento)/análise , Medição de Risco , Tório/análise , Trítio , Urânio/análise , Urinálise , Água
6.
Radiat Prot Dosimetry ; 170(1-4): 8-12, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26464525

RESUMO

The TECHREC project, funded by the European Commission, will provide Technical Recommendations for Monitoring Individuals for Occupational Intakes of Radionuclides It is expected that the document will be published by the European Commission as a report in its Radiation Protection Series during 2016. The project is coordinated by the European Radiation Dosimetry Group (EURADOS) and is being carried out by members of EURADOS Working Group 7 (Internal Dosimetry). This paper describes the aims and purpose of the Technical Recommendations, and explains how the project is organised.


Assuntos
Exposição Ocupacional/análise , Monitoramento de Radiação/normas , Proteção Radiológica/métodos , Radioisótopos/análise , Europa (Continente) , Humanos , Cooperação Internacional , Controle de Qualidade , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação
7.
Radiat Prot Dosimetry ; 144(1-4): 349-52, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21156780

RESUMO

EURADOS working group on 'Internal Dosimetry (WG7)' represents a frame to develop activities in the field of internal exposures as coordinated actions on quality assurance (QA), research and training. The main tasks to carry out are the update of the IDEAS Guidelines as a reference document for the internal dosimetry community, the implementation and QA of new ICRP biokinetic models, the assessment of uncertainties related to internal dosimetry models and their application, the development of physiology-based models for biokinetics of radionuclides, stable isotope studies, biokinetic modelling of diethylene triamine pentaacetic acid decorporation therapy and Monte-Carlo applications to in vivo assessment of intakes. The working group is entirely supported by EURADOS; links are established with institutions such as IAEA, US Transuranium and Uranium Registries (USA) and CEA (France) for joint collaboration actions.


Assuntos
Radiometria/normas , Amerício/análise , Europa (Continente) , Humanos , Cinética , Método de Monte Carlo , Ácido Pentético/química , Plutônio/análise , Controle de Qualidade , Monitoramento de Radiação/métodos , Radioisótopos/análise , Radiometria/métodos , Valores de Referência , Sistema de Registros , Reprodutibilidade dos Testes , Urânio/análise
8.
Radiat Prot Dosimetry ; 144(1-4): 592-5, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21051435

RESUMO

A training course named 'European Radiation Dosimetry Group/International Atomic Energy Agency Advanced Training Course on Internal Dose Assessment' was held in Czech Technical University in Prague from 2 to 6 February 2009. The course, jointly organised by the two organisations, had the aim of providing guidance on the application of IDEAS guidelines and of disseminating the results of EC CONRAD Project in relation to internal dosimetry (Work Package 5). At the end of the course a dose assessment exercise was proposed to participants. Four artificial cases, named exercises left to participants, were used to check the capabilities of application of the IDEAS guidelines, gained by participants during the event. The participants had to use both hand calculations and dedicated software, in limited time (7 h). Forty per cent of participants had solved all four cases in the allotted time. The results of the dose assessment were analysed to gain experience in types of errors assessors may make during the evaluations. The result of this intercomparison exercise was promising: half of the results in each case were equal to the 'reference evaluation estimate', which was obtained by applying the guidelines correctly.


Assuntos
Monitoramento de Radiação/normas , Proteção Radiológica/normas , Radiometria/normas , Congressos como Assunto , Currículo , Planejamento em Desastres , Europa (Continente) , Humanos , Exposição Ocupacional/análise , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Liberação Nociva de Radioativos , Radiometria/métodos , Valores de Referência , Reprodutibilidade dos Testes , Medição de Risco , Software , Fatores de Tempo
9.
Radiat Prot Dosimetry ; 131(1): 28-33, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18757895

RESUMO

The CONRAD Project is a Coordinated Network for Radiation Dosimetry funded by the European Commission 6th Framework Programme. The activities developed within CONRAD Work Package 5 ('Coordination of Research on Internal Dosimetry') have contributed to improve the harmonisation and reliability in the assessment of internal doses. The tasks carried out included a study of uncertainties and the refinement of the IDEAS Guidelines associated with the evaluation of doses after intakes of radionuclides. The implementation and quality assurance of new biokinetic models for dose assessment and the first attempt to develop a generic dosimetric model for DTPA therapy are important WP5 achievements. Applications of voxel phantoms and Monte Carlo simulations for the assessment of intakes from in vivo measurements were also considered. A Nuclear Emergency Monitoring Network (EUREMON) has been established for the interpretation of monitoring data after accidental or deliberate releases of radionuclides. Finally, WP5 group has worked on the update of the existing IDEAS bibliographic, internal contamination and case evaluation databases. A summary of CONRAD WP5 objectives and results is presented here.


Assuntos
Doses de Radiação , Monitoramento de Radiação , Radiometria , Dosagem Radioterapêutica , Pesquisa , Simulação por Computador , Bases de Dados como Assunto , Humanos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Radioisótopos/administração & dosagem , Radiometria/instrumentação , Incerteza
10.
Radiat Prot Dosimetry ; 131(1): 34-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18718961

RESUMO

The work of Task Group 5.1 (uncertainty studies and revision of IDEAS guidelines) and Task Group 5.5 (update of IDEAS databases) of the CONRAD project is described. Scattering factor (SF) values (i.e. measurement uncertainties) have been calculated for different radionuclides and types of monitoring data using real data contained in the IDEAS Internal Contamination Database. Based upon this work and other published values, default SF values are suggested. Uncertainty studies have been carried out using both a Bayesian approach as well as a frequentist (classical) approach. The IDEAS guidelines have been revised in areas relating to the evaluation of an effective AMAD, guidance is given on evaluating wound cases with the NCRP wound model and suggestions made on the number and type of measurements required for dose assessment.


Assuntos
Bases de Dados como Assunto , Monitoramento de Radiação , Radioisótopos/administração & dosagem , Teorema de Bayes , Creatinina/efeitos da radiação , Creatinina/urina , Fezes/química , Guias como Assunto , Humanos , Modelos Biológicos , Lesões por Radiação/fisiopatologia , Radioisótopos/química , Espalhamento de Radiação , Gravidade Específica/efeitos da radiação , Trítio/efeitos da radiação , Trítio/urina , Incerteza , Urina/química
11.
Radiat Prot Dosimetry ; 127(1-4): 339-42, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18045799

RESUMO

The IDEAS Guidelines for the assessment of internal doses from monitoring data suggest default measurement uncertainties (i.e. scattering factors, SFs) to be used for different types of monitoring data. However, these default values were mainly based upon expert judgement. In this paper, SF values have been calculated for different radionuclides and types of monitoring data using real data contained in the IDEAS Internal Contamination Database. Results are presented.


Assuntos
Bioensaio/estatística & dados numéricos , Bioensaio/normas , Fidelidade a Diretrizes/estatística & dados numéricos , Fidelidade a Diretrizes/normas , Guias de Prática Clínica como Assunto , Radiometria/estatística & dados numéricos , Radiometria/normas , Carga Corporal (Radioterapia) , União Europeia , Humanos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Radiat Prot Dosimetry ; 127(1-4): 303-10, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17933785

RESUMO

The need for harmonisation of the procedures for internal dose assessment has been recognised within an EU research project under the 5th Framework Programme. The aim of the IDEAS project was to develop general guidelines for standardising assessments of intakes and internal doses. It started in October 2001 and ended in June 2005. The project is closely related to some goals of the work of Committee 2 of the International Commission on Radiological Protection and since 2003 there has been close co-operation between the two groups. The general philosophy of the guidelines is focusing on the principles of harmonisation, accuracy and proportionality. The proposed system of 'level of task' to structure the approach of internal dose evaluation is also reported. Some details of the internal structure of the guidelines for the different pathways of intake are provided.


Assuntos
Algoritmos , Bioensaio/métodos , Modelos Biológicos , Guias de Prática Clínica como Assunto , Radiometria/métodos , Simulação por Computador , União Europeia , Humanos , Doses de Radiação , Eficiência Biológica Relativa
13.
Radiat Prot Dosimetry ; 127(1-4): 311-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17686965

RESUMO

The EUropean RAdiation DOSimetry Group (EURADOS) initiated in 2005 the CONRAD Project, a Coordinated Network for Radiation Dosimetry funded by the European Commission (EC), within the 6th Framework Programme (FP). The main purpose of CONRAD is to generate a European Network in the field of Radiation Dosimetry and to promote both research activities and dissemination of knowledge. The objective of CONRAD Work Package 5 (WP5) is the coordination of research on assessment and evaluation of internal exposures. Nineteen institutes from 14 countries participate in this action. Some of the activities to be developed are continuations of former European projects supported by the EC in the 5th FP (OMINEX and IDEAS). Other tasks are linked with ICRP activities, and there are new actions never considered before. A collaboration is established with CONRAD Work Package 4, dealing with Computational Dosimetry, to organise an intercomparison on Monte Carlo modelling for in vivo measurements of (241)Am deposited in a knee phantom. Preliminary results associated with CONRAD WP5 tasks are presented here.


Assuntos
Academias e Institutos/organização & administração , Bioensaio/métodos , União Europeia/organização & administração , Radiometria/tendências , Pesquisa/organização & administração , Carga Corporal (Radioterapia) , Humanos
14.
Radiat Prot Dosimetry ; 127(1-4): 317-20, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17562645

RESUMO

As part of the EU Fifth Framework Programme IDEAS project 'General Guidelines for the Evaluation of Incorporation Monitoring Data', and in collaboration with the International Atomic Energy Agency, a new intercomparison exercise for the assessment of doses from intakes of radionuclides was organised. Several cases were selected, to cover a wide range of practices in the nuclear fuel cycle and medical applications. The cases were: (1) acute intake of HTO, (2) acute inhalation of the fission products 137Cs and 90Sr, (3) acute inhalation of 60Co, (4) repeated intakes of 131I, (5) intake of enriched uranium and (6) single intake of Pu isotopes and 241Am. This intercomparison exercise especially focused on the effect of the Guidelines proposed by the IDEAS project for harmonisation of internal dosimetry.


Assuntos
Bioensaio/métodos , Guias de Prática Clínica como Assunto , Radiometria/métodos , Carga Corporal (Radioterapia) , Europa (Continente) , Fidelidade a Diretrizes , Doses de Radiação , Sensibilidade e Especificidade
15.
Radiat Prot Dosimetry ; 125(1-4): 56-60, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17351269

RESUMO

An Internet based intercomparison exercise on assessment of occupational exposure due to intakes of radionuclides has been performed to check the applicability of the 'General Guidelines for the Assessment of Internal Dose from Monitoring Data' developed by the IDEAS group. There were six intake cases presented on the Internet and 81 participants worldwide reported solutions to these cases. Results of the exercise indicate that the guidelines have a positive influence on the methodologies applied for dose assessments and, if correctly applied, improve the harmonisation of assessed doses.


Assuntos
Carga Corporal (Radioterapia) , Internet , Exposição Ocupacional/análise , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Medição de Risco/normas , Europa (Continente) , Humanos , Internacionalidade , Exposição Ocupacional/prevenção & controle , Controle de Qualidade , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Radiat Prot Dosimetry ; 125(1-4): 41-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17213216

RESUMO

In radiation protection dosimetry the quantity of interest is the effective dose (E); the dose limit to an adult worker applies to the sum of the relevant doses from external exposures and the relevant committed effective doses from intakes of radionuclides, during the same period of time. A EURADOS study was carried out to investigate how the results from personal dosemeters for external radiation, from workplace monitoring and from monitoring of internal exposures can be combined into a consistent system of individual monitoring. The integration of dosimetric methods and data for external and internal radiation require the complete characterisation of the occupational exposure present at the workplace, and the availability of adequate equipment and tools for the assessment of effective dose. To evaluate the capability of services to accomplish this approach, a European Dosimetry Network has been established among 28 European countries through the respective contact-persons and their dosimetric facilities which collaborated with EURADOS providing relevant data about performance and legal aspects. The information collected was presented as a monograph in Radiation Protection Dosimetry in 2004. The more relevant conclusions of this study are presented here.


Assuntos
Fidelidade a Diretrizes/normas , Guias como Assunto , Modelos Biológicos , Exposição Ocupacional/análise , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Gestão da Segurança/normas , Algoritmos , Simulação por Computador , Europa (Continente) , Humanos , Exposição Ocupacional/prevenção & controle , Padrões de Referência , Eficiência Biológica Relativa , Medição de Risco/normas
17.
Radiat Prot Dosimetry ; 125(1-4): 520-2, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17012307

RESUMO

In the scope of the IDEAS project to develop General Guidelines for the Assessment of Internal Dose from Monitoring data, two databases were compiled. The IDEAS Bibliography database contains references dealing with problems related to cases of internal contamination. The IDEAS Internal Contamination Database now contains more than 200 cases of internal contamination. In the near future, the IDEAS Internal Contamination database will be made available to the internal dosimetry community. The database has several potential applications, including: training, testing biokinetic models, testing software for calculating intakes and doses from bioassay data, comparison of data from a new accidental intake with that from previous exposures to similar materials. The database is by no means complete, and this presentation is also an appeal for internal contamination cases to extend and update it.


Assuntos
Bioensaio/métodos , Bases de Dados Factuais , Exposição Ambiental/análise , Modelos Biológicos , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radioisótopos/farmacocinética , Simulação por Computador , Humanos , Internacionalidade , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Radiat Prot Dosimetry ; 125(1-4): 19-22, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17041240

RESUMO

In recent major international intercomparison exercises on intake and internal dose assessments from monitoring data, the results calculated by different participants varied significantly. Based on this experience the need for harmonisation of the procedures has been formulated within an EU 5th Framework Programme research project. The aim of the project, IDEAS, is to develop general guidelines for standardising assessments of intakes and internal doses. The IDEAS project started in October 2001 and ended in June 2005. The project is closely related to some goals of the work of Committee 2 of the ICRP and since 2003 there has been close cooperation between the two groups. To ensure that the guidelines are applicable to a wide range of practical situations, the first step was to compile a database of well-documented cases of internal contamination. In parallel, an improved version of an existing software package was developed and distributed to the partners for further use. A large number of cases from the database was evaluated independently by the partners and the results reviewed. Based on these evaluations, guidelines were drafted and discussed with dosimetry professionals from around the world by means of a virtual workshop on the Internet early in 2004. The guidelines have been revised and refined on the basis of the experiences and discussions in this virtual workshop. The general philosophy of the Guidelines is presented here, focusing on the principles of harmonisation, optimisation and proportionality. Finally, the proposed Levels of Task to structure the approach of internal dose evaluation are reported.


Assuntos
Fidelidade a Diretrizes/normas , Guias como Assunto , Modelos Biológicos , Exposição Ocupacional/análise , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Gestão da Segurança/normas , Algoritmos , Simulação por Computador , Europa (Continente) , Humanos , Exposição Ocupacional/prevenção & controle , Padrões de Referência , Eficiência Biológica Relativa , Medição de Risco/normas
19.
Radiat Prot Dosimetry ; 118(2): 176-81, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16581922

RESUMO

Once the EC Directive 96/29 has been implemented into national regulation across Europe, the coordination of dosimetry laboratories for the monitoring of occupational exposures becomes the principal aim to achieve. Within this framework the European Radiation Dosimetry Group, EURADOS, carried out an Action on 'Harmonisation of Individual Monitoring' (2000-2004) to promote coordination in the field of individual monitoring of occupational exposures throughout Europe. With reference to internal exposures, the main aims were the completion of a catalogue of internal dosimetry services and an inventory of methods and techniques used for individual monitoring at European internal dosimetry facilities. At the end of this EURADOS Action, a report was published in Radiation Protection Dosimetry in 2004. The information collected related to various topics: the equipments used for the measurement of internal exposures, calibration and sensitivity data, the methods applied for the assessment of internal doses, Quality Control procedures, Quality Assurance Programmes in the facilities and legal requirements. The information to be presented here will give a general overview of the actual status of individual monitoring for internal exposures in Europe.


Assuntos
Exposição Ambiental , Monitoramento de Radiação/métodos , Radiometria/normas , Radiação de Fundo , Carga Corporal (Radioterapia) , Europa (Continente) , União Europeia , Dosimetria Fotográfica , Humanos , Pulmão/efeitos da radiação , Fótons , Controle de Qualidade , Doses de Radiação , Monitoramento de Radiação/normas , Proteção Radiológica , Radiometria/métodos
20.
Radiat Prot Dosimetry ; 118(2): 139-43, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16581923

RESUMO

Following the publication of the EU Council Directive 96/29, EURADOS coordinated two working groups (WGs) for promoting the process of harmonisation on individual monitoring of occupationally exposed persons in Europe. An overview of the major findings of the second WG is presented. Information on the technical and quality standards and on the accreditation and approval procedures has been compiled. The catalogue of dosimetric services has been updated and extended. An overview of national regulations and standards for protection from radon and other natural sources in workplaces has been made, attempting to combine the results from individual monitoring for external, internal and workplace monitoring. A first status description of the active personal dosemeters, including legislative and technical information, and their implementation has been made. The importance of practical factors on the uncertainty in the dose measurement has been estimated. Even if a big progress has been made towards harmonisation, there is still work to be done.


Assuntos
Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiometria/instrumentação , Europa (Continente) , União Europeia , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Radiometria/métodos , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...