1.
Philos Trans A Math Phys Eng Sci ; 372(2010): 20130025, 2014 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-24470410

RESUMO

The first clinical study of phase-contrast mammography (PCM) with synchrotron radiation was carried out at the Synchrotron Radiation for Medical Physics beamline of the Elettra synchrotron radiation facility in Trieste (Italy) in 2006-2009. The study involved 71 patients with unresolved breast abnormalities after conventional digital mammography and ultrasonography exams carried out at the Radiology Department of Trieste University Hospital. These cases were referred for mammography at the synchrotron radiation facility, with images acquired using a propagation-based phase-contrast imaging technique. To investigate the contribution of phase-contrast effects to the image quality, two experienced radiologists specialized in mammography assessed the visibility of breast abnormalities and of breast glandular structures. The images acquired at the hospital and at the synchrotron radiation facility were compared and graded according to a relative seven-grade visual scoring system. The statistical analysis highlighted that PCM with synchrotron radiation depicts normal structures and abnormal findings with higher image quality with respect to conventional digital mammography.


Assuntos
Mamografia/métodos , Mama/citologia , Humanos , Mamografia/instrumentação , Controle de Qualidade , Sensibilidade e Especificidade
2.
Radiology ; 259(3): 684-94, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21436089

RESUMO

PURPOSE: To prospectively evaluate the diagnostic contribution of mammography with synchrotron radiation in patients with questionable or suspicious breast abnormalities identified at combined digital mammography (DM) and ultrasonography (US). MATERIALS AND METHODS: The ethics committee approved this prospective study, and written informed consent was obtained from all patients. Mammography with synchrotron radiation was performed with a phase-detection technique at a synchrotron radiation laboratory. Forty-nine women who met at least one of the inclusion criteria (palpable mass, focal asymmetry, architectural distortion, or equivocal or suspicious mass at DM; none clarified at US) were enrolled. Forty-seven women (mean age, 57.8 years ± 8.8 [standard deviation]; age range, 43-78 years) completed the study protocol, which involved biopsy or follow-up for 1 year as the reference standard. Breast Imaging Reporting and Data System (BI-RADS) scores of 1-3 were considered to indicate a negative result, while scores 4-5 were considered to indicate a positive result. The visibility of breast abnormalities and the glandular parenchymal structure at DM and at mammography with synchrotron radiation was compared by using the Wilcoxon signed rank test. RESULTS: In 29 of the 31 patients with a final diagnosis of benign entity, mammography with synchrotron radiation yielded BI-RADS scores of 1-3. In 13 of the remaining 16 patients with a final diagnosis of malignancy, mammography with synchrotron radiation yielded BI-RADS scores of 4-5. Therefore, a sensitivity of 81% (13 of 16 patients) and a specificity of 94% (29 of 31 patients) were achieved with use of the described BI-RADS dichotomization system. CONCLUSION: These study results suggest that mammography with synchrotron radiation can be used to clarify cases of questionable or suspicious breast abnormalities identified at DM. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11100745/-/DC1.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Síncrotrons , Adulto , Idoso , Biópsia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Sensibilidade e Especificidade , Estatísticas não Paramétricas
3.
Phys Med Biol ; 49(9): 1739-54, 2004 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-15152928

RESUMO

A system for in vivo breast imaging with monochromatic x-rays has been designed and built at the synchrotron radiation facility Elettra in Trieste (Italy) and will be operational in 2004. The system design involves the possibility of performing both planar mammography and breast tomography. In the present work, the first results obtained with a test set-up for breast tomography are shown and discussed. Tomographic images of in vitro breasts were acquired using monochromatic x-ray beams in the energy range 20-28 keV and a linear array silicon pixel detector. Tomograms were reconstructed using standard filtered backprojection algorithms; the effect of different filters was evaluated. The attenuation coefficients of fibroglandular and adipose tissue were measured, and a quantitative comparison of images acquired at different energies was performed by calculating the differential signal-to-noise ratio of fibroglandular details in adipose tissue. All images required a dose comparable to the dose delivered in clinical, conventional mammography and showed a high resolution of the breast structures without the overlapping effects that limit the visibility of the structures in 2D mammography. A quantitative evaluation of the images proves that the image quality at a given dose increases in the considered energy range and for the considered breast sizes.


Assuntos
Mama/patologia , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Tecido Conjuntivo/diagnóstico por imagem , Tecido Conjuntivo/patologia , Humanos , Aumento da Imagem , Itália , Mamografia/instrumentação , Mamografia/métodos , Radiação , Doses de Radiação , Silício , Tomografia Computadorizada por Raios X/instrumentação