Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JAMA Cardiol ; 9(7): 641-648, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776097

RESUMO

Importance: Atrial fibrillation and obesity are common, and both are increasing in prevalence. Obesity is associated with failure of cardioversion of atrial fibrillation using a standard single set of defibrillator pads, even at high output. Objective: To compare the efficacy and safety of dual direct-current cardioversion (DCCV) using 2 sets of pads, with each pair simultaneously delivering 200 J, with traditional single 200-J DCCV using 1 set of pads in patients with obesity and atrial fibrillation. Design, Setting, and Participants: This was a prospective, investigator-initiated, patient-blinded, randomized clinical trial spanning 3 years from August 2020 to 2023. As a multicenter trial, the setting included 3 sites in Louisiana. Eligibility criteria included body mass index (BMI) of 35 or higher (calculated as weight in kilograms divided by height in meters squared), age 18 years or older, and planned nonemergent electrical cardioversion for atrial fibrillation. Patients who met inclusion criteria were randomized 1:1. Exclusions occurred due to spontaneous cardioversion, instability, thrombus, or BMI below threshold. Interventions: Dual DCCV vs single DCCV. Main Outcomes and Measures: Return to sinus rhythm, regardless of duration, immediately after the first cardioversion attempt of atrial fibrillation, adverse cardiovascular events, and chest discomfort after the procedure. Results: Of 2079 sequential patients undergoing cardioversion, 276 met inclusion criteria and were approached for participation. Of these, 210 participants were randomized 1:1. After exclusions, 200 patients (median [IQR] age, 67.6 [60.1-72.4] years; 127 male [63.5%]) completed the study. The mean (SD) BMI was 41.2 (6.5). Cardioversion was successful more often with dual DCCV compared with single DCCV (97 of 99 patients [98%] vs 87 of 101 patients [86%]; P = .002). Dual cardioversion predicted success (odds ratio, 6.7; 95% CI, 3.3-13.6; P = .01). Patients in the single cardioversion cohort whose first attempt failed underwent dual cardioversion with all subsequent attempts (up to 3 total), all of which were successful: 12 of 14 after second cardioversion and 2 of 14 after third cardioversion. There was no difference in the rating of postprocedure chest discomfort (median in both groups = 0 of 10; P = .40). There were no cardiovascular complications. Conclusions and Relevance: In patients with obesity (BMI ≥35) undergoing electrical cardioversion for atrial fibrillation, dual DCCV results in greater cardioversion success compared with single DCCV, without any increase in complications or patient discomfort. Trial Registration: ClinicalTrials.gov Identifier: NCT04539158.


Assuntos
Fibrilação Atrial , Cardioversão Elétrica , Obesidade , Humanos , Fibrilação Atrial/terapia , Masculino , Cardioversão Elétrica/métodos , Feminino , Obesidade/complicações , Obesidade/terapia , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Resultado do Tratamento , Índice de Massa Corporal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA