Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ophthalmol Glaucoma ; 3(3): 196-201, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32672615

RESUMO

PURPOSE: Patients with myopia are at increased risk for the development of glaucoma. The inability to correct for axial length on spectral-domain (SD) OCT translates into lower signal strength and scan reliability in patients with high axial myopia. We evaluated the effectiveness of a contact lens to increase the signal strength and to assess optic nerve dimensions and nerve fiber layer (NFL) thickness using SD OCT in patients with glaucoma or who are glaucoma suspects with high axial myopia. DESIGN: Single-center, prospective, interventional study. PARTICIPANTS: Patients with axial lengths of more than 25.5 mm with a diagnosis of glaucoma or glaucoma suspect. METHODS: The optic nerve cube 200×200 scan using the Cirrus SD OCT 400 (Carl Zeiss Meditec, Inc., Dublin, CA) was carried out first without the use of a contact lens and then repeated with placement of the contact lens to correct for the spherical equivalent of the refractive error. MAIN OUTCOME MEASURES: The primary outcome measure was the change in the average NFL thickness before and after use of the contact lens. Secondary outcome measures included the changes in cup volume, disc area, and rim area on OCT. RESULTS: Twelve patients were recruited (20 eyes); the average axial length was 27.06 mm, and the average signal strength interval increased by 1.73 (P = 0.001). With the use of a contact lens, the average NFL thickness was significantly thicker. None of the changes in the secondary outcome measures were significant: rim area, cup volume, or disc area. CONCLUSIONS: Based on our data, the use of a contact lens statistically improved the signal strength and average NFL thickness of the SD OCT scan. The ability to capture the perimeter of the optic disc accurately can be limited in the setting of peripapillary atrophy, which was present in all but 2 participants. Future studies with a larger number of participants and a wider range of axial myopia to discern if contact lens correction has a greater effect on the highest axial lengths are needed.


Assuntos
Lentes de Contato , Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Miopia Degenerativa/diagnóstico , Nervo Óptico/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Glaucoma/complicações , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Miopia Degenerativa/complicações , Miopia Degenerativa/fisiopatologia , Fibras Nervosas/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
2.
Artigo em Inglês | MEDLINE | ID: mdl-32518692

RESUMO

BACKGROUND: Vitamin A deficiency is rare in the United States and can be missed in patients with malabsorption syndromes without a high dose of suspicion. Ocular complications of hypovitaminosis A include xerosis and nyctalopia, and to a lesser extent reduction in visual acuity and color vision. Outer retinal changes, as seen on spectral domain optic coherence tomography (SD-OCT), in patients with vitamin A deficiency have previously not been documented. CASE PRESENTATION: We present two cases with symptoms of severe nyctalopia who were subsequently diagnosed with severe Vitamin A deficiency and their unique findings on SD-OCT of outer nuclear layer diffuse thinning with irregular appearance of the interdigitating zone and the ellipsoid zone as well as normalization after vitamin A supplementation. CONCLUSIONS: Outer nuclear layer thinning and disruption of the outer retinal bands on SD-OCT are reversible with correction of vitamin A deficiency. Improvement in visual acuity, color vision, and nyctalopia are possible with early diagnosis and appropriate treatment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA