Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 9(1): 16484, 2019 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-31712687

RESUMO

The urinary tissue inhibitor of metalloproteinases-2 and insulin-like growth factor-binding protein 7 ([TIMP-2]∙[IGFBP7]) have been introduced to improve risk prediction of severe acute kidney injury (AKI) within 12 hours of measurement. We performed a prospective cohort study to evaluate if the predictive value of [TIMP-2]∙[IGFBP7] for AKI might continue after 12 hours. We enrolled 442 critically ill adult patients from June to December 2016. Urine samples were collected at admission for [TIMP-2]∙[IGFBP7] measurement. Baseline patient characteristics were recorded including patients' demographics, prior health history, and the main reason for admission to build a logistic regression model to predict AKI. AKI occurrence differed between patients with [TIMP-2]∙[IGFBP7] ≤0.3 and >0.3 (ng/ml)2/1000 (31.9% and 68.10% respectively; p < 0.001). Patients with AKI had higher biomarker values compared to those without AKI (0.66 (0.21-2.84) vs 0.22 (0.08-0.63) (ng/ml)2/1000; p < 0.001). [TIMP-2]∙[IGFBP7] at ICU admission had a lower performance in predicting AKI at any stage within 48 hours and 7 days after measurement (area under the receiver operating characteristic curve (AUC) equal to 0.70 (95%CI 0.65-0.76), AUC 0.68 (95%CI 0.63-0.73)). In the logistic regression model, 0.1 (ng/ml)2/1000-unit increment was likely to increase the risk of AKI by 2% (p = 0.002).


Assuntos
Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/urina , Biomarcadores , Inibidor Tecidual de Metaloproteinase-2/urina , Injúria Renal Aguda/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cuidados Críticos , Feminino , Hospitalização , Humanos , Unidades de Terapia Intensiva , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Razão de Chances , Curva ROC , Medição de Risco , Fatores de Risco , Fatores de Tempo
2.
Clin Kidney J ; 12(2): 300-307, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30976412

RESUMO

BACKGROUND: Since 2005, three human clinical trials have been performed with the Wearable Artificial Kidney (WAK) and Wearable Ultrafiltration (WUF) device. The lack of an adequate vascular access (VA) has been pointed out as the main limitation to their implementation. Based on the current level of understanding, we will make the first conceptual proposal of an adequate VA suitable for the WAK and the WUF. METHODS: All the literature related to WAK and WUF was reviewed. Based on eight main publications the VA major characteristics were defined: a mean blood flow of 100 mL/min; the capability to allow prolonged and frequent dialysis treatments, without interfering in activities of daily living (ADL); safe and convenient connection/disconnection systems; reduced risk of biofilm formation and coagulation; high biocompatibility. A research was done in order to answer to each necessary technological prerequisites. RESULTS: The use of a device similar to a CVC with a 5Fr lumen, seems to be the most feasible option. Totally subcutaneous port devices, like the LifeSite(R) or Dialock (R) systems can be a solution to allow WAK or WUF to operate continuously while patients carry out their ADL. Recently, macromolecules that reduce the risk of thrombosis and infection and are integrated into a CVC have been developed and have the capability of overcoming these major limitations. CONCLUSION: With an adequate VA, portable HD devices can be acceptable options to address several unmet clinical needs of HD patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA