Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
2.
BMC Pregnancy Childbirth ; 22(1): 254, 2022 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-35346088

RESUMO

OBJECTIVE: Our aim was to assess diagnostic accuracy in the prediction of small for gestational age (SGA <10th centile) and fetal growth restricted (FGR) (SGA <3rd centile) fetuses using three different sonographic methods in pregnancies at increased risk of fetal growth restriction: 1) fetal abdominal circumference (AC) z-scores, 2) estimated fetal weight (EFW) z-scores according to postnatal reference standard; 3) EFW z-scores according to a prenatal reference standard. METHODS: Singleton pregnancies at increased risk of fetal growth restriction seen in two university hospitals between 2014 and 2015 were studied retrospectively. EFW was calculated using formulas proposed by the INTERGROWTH-21st project and Hadlock; data derived from publications by the INTEGROWTH-twenty-first century project and Hadlock were used to calculate z-scores (AC and EFW). The accuracy of different methods was calculated and compared. RESULTS: The study group included 406 patients. Prenatal standard EFW z-scores derived from INTERGROWTH-21st project and Hadlock and co-workers performed similarly and were more accurate in identifying SGA infants than using AC z-scores or a postnatal reference standard. The subgroups analysis demonstrated that EFW prenatal standard was more or similarly accurate compared to other methods across all subgroups, defined by gestational age and birth weight. CONCLUSIONS: Prenatal standard EFW z-scores derived from either INTERGROWTH-21 st project or Hadlock and co-workers publications demonstrated a statistically significant advantage over other biometric methods in the diagnosis of SGA fetuses.


Assuntos
Retardo do Crescimento Fetal , Peso Fetal , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Feto , Idade Gestacional , Humanos , Gravidez , Diagnóstico Pré-Natal , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos
3.
Artigo em Inglês | MEDLINE | ID: mdl-33923642

RESUMO

The new coronavirus emergency spread to Italy when little was known about the infection's impact on mothers and newborns. This study aims to describe the extent to which clinical practice has protected childbirth physiology and preserved the mother-child bond during the first wave of the pandemic in Italy. A national population-based prospective cohort study was performed enrolling women with confirmed SARS-CoV-2 infection admitted for childbirth to any Italian hospital from 25 February to 31 July 2020. All cases were prospectively notified, and information on peripartum care (mother-newborn separation, skin-to-skin contact, breastfeeding, and rooming-in) and maternal and perinatal outcomes were collected in a structured form and entered in a web-based secure system. The paper describes a cohort of 525 SARS-CoV-2 positive women who gave birth. At hospital admission, 44.8% of the cohort was asymptomatic. At delivery, 51.9% of the mothers had a birth support person in the delivery room; the average caesarean section rate of 33.7% remained stable compared to the national figure. On average, 39.0% of mothers were separated from their newborns at birth, 26.6% practised skin-to-skin, 72.1% roomed in with their babies, and 79.6% of the infants received their mother's milk. The infants separated and not separated from their SARS-CoV-2 positive mothers both had good outcomes. At the beginning of the pandemic, childbirth raised awareness and concern due to limited available evidence and led to "better safe than sorry" care choices. An improvement of the peripartum care indicators was observed over time.


Assuntos
COVID-19 , Complicações Infecciosas na Gravidez , Cesárea , Criança , Feminino , Humanos , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas , Itália/epidemiologia , Gravidez , Complicações Infecciosas na Gravidez/epidemiologia , Estudos Prospectivos , SARS-CoV-2
4.
Am J Obstet Gynecol MFM ; 3(4): 100341, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33652157

RESUMO

BACKGROUND: Insufficient and imprecise information during pregnancy can lead to an overestimation of maternal and fetal risk associated to various exposures during gestation. OBJECTIVE: This study aimed to assess whether expert obstetrical counseling in cases of maternal infections at risk of vertical transmission could impact maternal perception of risk and the tendency to terminate pregnancy. STUDY DESIGN: This is a monocentric prospective observational study of 185 consecutive pregnant women with confirmed diagnosis of infectious diseases at risk of vertical transmission during the first or second trimester of pregnancy. Patients were divided into 2 different groups, according to the type infectious disease: infections at high risk of fetal damages and infections at low risk. Every woman included in the study underwent medical counseling with a physician with experience of vertically transmitted infections. Moreover, each woman involved in the study was offered a detailed second trimester ultrasound scan. Maternal concern for their pregnancy and the disposition to interrupt the pregnancy were investigated by 2 questionnaires submitted to patients before and after medical expert counseling; a third questionnaire was completed only by those women who decided to undergo second trimester ultrasound scan at our hospital. RESULTS: Of the 185 consecutive patients meeting the inclusion criteria, 171 (92.4%) filled out the visual analog scale for concern about the baby's health both before and after medical consultation. After medical consultation, there was a significant decrease in mean visual analog scale for concern: from 67.1±26.0 to 41.3±28.8 (change score, -25.8; 95% confidence interval, -29.9 to -21.7). Higher baseline levels of concern had more room for reduction, and infections at high fetal risk of damage were associated with lower decrease in concern. However, risk perception decreased in both low-risk and high-risk pregnancies. Notably, 82 patients (53.2%) underwent ultrasonography and filled out the visual analog scale after examination. The mean score after examination was 28.3±24.4 and significantly lower than the mean score registered after consultation (change score, -16.6; 95% confidence interval, -22.9 to -10.3). A total of 162 women (87.6%) declared their tendency to interrupt pregnancy both before and after the consultation. There was a significant decrease in mean tendency from 42.1±32.6 to 22.7±27.1 (change score, -19.4; 95% confidence interval, -23.6 to -15.2). Regression analysis revealed that both low- and high-risk patients significantly reduced their tendency. A total of 73 patients (45.1%) underwent ultrasonography and filled out the visual analog scale after examination. The mean score after examination was 9.9±20.6 and significantly lower than the mean score registered after consultation (change score, -13.4; 95% confidence interval, -19.1 to -7.7). CONCLUSION: Our results confirm the importance of a comprehensive and sufficient expert medical counseling that, on one hand, can reduce maternal risk perception, improving quality of life for mothers, and, on the other hand, can lead to feasible results, reducing a woman's disposition to termination of pregnancy.


Assuntos
Aconselhamento , Qualidade de Vida , Feminino , Humanos , Percepção , Gravidez , Primeiro Trimestre da Gravidez , Segundo Trimestre da Gravidez
5.
Am J Obstet Gynecol MFM ; 2(4): 100217, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33345926

RESUMO

BACKGROUND: Malpositions and deflexed cephalic malpresentations are well recognized causes of dysfunctional labor, may result in fetal and maternal complications, and are diagnosed more precisely with an ultrasound examination than with a digital examination. OBJECTIVE: This study aimed to assess the incidence of malpositions and deflexed cephalic malpresentations at the beginning of the second stage of labor and to evaluate the role of the sonographic diagnosis of deflexion in the prediction of the mode of delivery. STUDY DESIGN: Women in labor with a singleton pregnancy at term with fetuses in a cephalic presentation at 10 cm of cervical dilatation were prospectively examined. A transabdominal ultrasound was performed to assess the fetal head position by demonstrating the fetal occiput or the eyes. Deflexion was assessed by the measurement of the occiput-spine angle when the occiput was anterior or transverse and by qualitative assessment of the relationship between chin and thorax when the occiput was posterior. Transperineal ultrasound was performed in occiput posterior fetuses to discriminate between sinciput, brow, and face presentation. Maternal, labor, and neonatal parameters including maternal age, induction of labor, use of epidural, birthweight, arterial pH, and neonatal intensive care unit admission were recorded. Patients were divided into 2 groups according to the sonographic diagnosis of head deflexion. Adjusted odds ratios were calculated using multivariate logistic regression to determine the association between cesarean delivery and the 2 groups. In addition, labor and neonatal characteristics were compared between occiput anterior and occiput posterior-occiput transverse fetuses. RESULTS: Of the 200 women at the beginning of the second stage, the fetus was in occiput anterior position in 156 (78%), transverse in 11 (5.5%), and posterior in 33 (16.5%) cases. Deflexion was diagnosed in 33 of 156 (21.2%) occiput anterior fetuses and 19 of 44 (43.2%) occiput posterior and occiput transverse fetuses. Cesarean deliveries were significantly associated with fetal head deflexion both in occiput anterior (P=.001) and occiput posterior (P<.001) fetuses. Sonographic diagnosis of fetal head deflexion was an independent risk factor for cesarean delivery both in occiput anterior (adjusted odds ratio, 5.37; 95% confidence interval, 1.819-15.869) and occiput posterior (adjusted odds ratio, 13.9; 95% confidence interval, 1.958-98.671) cases, and it was an independent risk factor for cesarean delivery regardless of the occiput position (adjusted odds ratio, 5.83; 95% confidence interval, 2.47-13.73). CONCLUSION: The sonographic diagnosis of fetal head deflexion at the beginning of the second stage increases the risk of cesarean delivery.


Assuntos
Feto , Apresentação no Trabalho de Parto , Cesárea , Feminino , Feto/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Humanos , Recém-Nascido , Gravidez , Ultrassonografia Pré-Natal
6.
Arch Gynecol Obstet ; 299(4): 947-951, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30730012

RESUMO

PURPOSE: To determine reference values for umbilical Doppler pulsatility index in fetuses with isolated two-vessel cord and to compare these values with standard umbilical Doppler pulsatility index curves from 23 to 40 gestational weeks. METHODS: A retrospective longitudinal cohort study was conducted between January 2014 and December 2017 in a tertiary referral hospital and included 62 pregnant women with isolated single umbilical artery (two-vessel cord) and 174 measurements. Only uncomplicated term pregnancies were included. A reference curve for umbilical Doppler pulsatility index was built up and compared with a standard curve commonly used for fetuses with three-vessel cord. RESULTS: Umbilical Doppler pulsatility index values were much lower than expected in cases with two-vessel cord compared to 3-vessel cord: mean of the regression equations was 1.02 ± 0.23 vs. 0.86 ± 0.19, respectively (p value < 0.001). This difference was quite constant across the gestational weeks considered, showing that the slopes of the two regressions were very similar. CONCLUSION: Reference curves for umbilical Doppler pulsatility index in two-vessel cord pregnancies were determined. Pulsatility index values were significantly different compared with those commonly used for three-vessel cord. Using lower reference values for umbilical pulsatility index in cases with two-vessel cord may allow a better identification of fetuses affected with intrauterine growth restriction, thus improving fetal surveillance.


Assuntos
Artéria Umbilical Única/fisiopatologia , Ultrassonografia Pré-Natal/métodos , Artérias Umbilicais/diagnóstico por imagem , Cordão Umbilical/diagnóstico por imagem , Adulto , Feminino , Feto , Humanos , Recém-Nascido , Estudos Longitudinais , Gravidez , Valores de Referência , Estudos Retrospectivos , Artérias Umbilicais/patologia
7.
Am J Obstet Gynecol MFM ; 1(1): 82-88, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-33319759

RESUMO

BACKGROUND: Paravaginal hematoma can be a severe postpartum complication. Diagnosis is challenging because signs and symptoms are often nonspecific. Most of the available literature about diagnostic imaging in these cases focuses on the use of computed tomography or magnetic resonance imaging, and there are very limited data on the use of sonography. OBJECTIVE: The purpose of this study was to evaluate the usefulness of sonography in the diagnosis of paravaginal hematomas from a review of our own experience. STUDY DESIGN: This was a retrospective study that included patients with postpartum paravaginal hematoma after vaginal delivery who underwent transabdominal or transperineal ultrasound in our University Hospital in Bologna from 2014-2016. Ultrasound features, dimensions, and relationship with other pelvic organs of the paravaginal hematoma were obtained. Information on patients' characteristics, symptoms, mode of delivery, treatment, and outcomes were recorded. RESULTS: We retrieved 11 cases of paravaginal hematoma after vaginal delivery in which ultrasound scanning was performed. The indications for ultrasound evaluation after delivery were pelvic and/or perianal pain, swelling of the vulva, and urinary retention, frequently in combination. The hematomas were always clearly visualized by sonography performed either transabdominally or transperineally with a full bladder as hypoechoic collections posterior to the vagina. The lesions were found to range in size of 4-10 cm. All patients underwent surgical treatment that consisted of incision of the hematoma and identification and ligature of any feeding vessels; packing was necessary in 8 cases (73%), and drainage was necessary in 5 cases (45%); however, 4 patients (36%) required reintervention. CONCLUSION: Transabdominal (performed with a full bladder) or transperineal sonography can visualize paravaginal hematomas effectively after vaginal delivery. We suggest that in cases of otherwise unexplained postpartum pelvic and perianal pain, swelling of the vulva, and/or urinary retention, ultrasound can be considered as the first-line imaging tool.


Assuntos
Período Pós-Parto , Vagina , Feminino , Hematoma/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Ultrassonografia , Vagina/diagnóstico por imagem
8.
Am J Obstet Gynecol MFM ; 1(2): 148-155, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-33345820

RESUMO

BACKGROUND: Intrapartum ultrasound scanning has been proposed as an ancillary tool in the decision-making process of instrumental vaginal delivery. OBJECTIVE: The purpose of this study was to evaluate the correlation between the sonographic visualization with a transperineal scan of the fetal occiput or forehead distal to the pubic symphysis with anterior or posterior presentation, respectively (fetal occiput or forehead sign), and the outcome of a vacuum delivery. STUDY DESIGN: We conducted a retrospective cohort study of patients who underwent a vacuum application in our hospital from 2011-2017, excluding outlet applications. In each case, a preliminary transperineal scan was performed to confirm fetal presentation and position and to demonstrate the presence or absence of the fetal occiput or forehead sign. The head direction, angle of progression, and the head perineum distance were also noted. The primary outcome measure was the success of the vacuum. The secondary outcome measures included fetal complications and perineal lacerations. RESULTS: A total of 196 consecutive patients were enrolled in the study. The occiput or forehead sign was present in 150 and was associated with a successful vaginal extraction in all cases. Of the 46 cases without the sign, 5 babies (10.8%) were delivered by cesarean section after a failed vacuum (P=.0006). The occiput or forehead sign was also associated with fewer grade 3-4 perineal lacerations (10.7% vs 35.7%; P=.0005) and cephalohematomas, although the difference was not statistically significant (1.4% vs 4.3%). There was a good correlation between the occiput or forehead sign and the other sonographic methods that previously had been proposed to predict a successful vacuum extraction, such as head direction, angle of progression, and head perineum distance. CONCLUSION: In our hands, the fetal occiput or forehead sign was associated strongly with successful vacuum application and with a very low rate of maternal and fetal complications.


Assuntos
Parto Obstétrico/métodos , Testa/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Vácuo-Extração/estatística & dados numéricos , Adulto , Feminino , Humanos , Apresentação no Trabalho de Parto , Complicações do Trabalho de Parto/diagnóstico por imagem , Gravidez , Estudos Prospectivos , Estudos Retrospectivos
9.
Int J Womens Health ; 9: 643-656, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28979167

RESUMO

During the last decade, there has been a huge advancement in the use of transperineal ultrasound (TPU) in the field of obstetrics and gynecology. Its main applications in obstetrics include the monitoring of fetal progression in labor and recently the assessment of maternal pelvic dimensions, whereas in gynecology, TPU is at present widely used for the evaluation of the female pelvic floor, opening new boundaries for the assessment of pelvic floor disorders. The association of volumetric three-dimensional techniques has largely contributed to the remarkable progress that has occurred in the use of TPU. The aim of this paper is to offer an overview of the advantages, challenges and future perspectives of the use of TPU for women's imaging.

10.
Fetal Diagn Ther ; 42(4): 249-256, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28399531

RESUMO

OBJECTIVE: To evaluate the ability of intrapartum ultrasound to differentiate occipitoposterior (OP) rotation with normal flexion of the head from deflexion, to compare the accuracy of ultrasound with the digital examination, and to assess the outcome of labor according to the type of presentation. PATIENTS AND METHODS: A retrospective study of patients with abnormal labor because of either prolongation and/or abnormal cardiotocography and OP rotation who underwent intrapartum sonography. RESULTS: Normal flexion was inferred in 36/42 cases by a longitudinal sonographic view of the fetal face demonstrating the chin approaching the chest. In the remaining 6, deflexion was diagnosed by visualizing the chin separate and distant from the chest. In 3 of these cases, the orbits were at the same level of the pubis suggesting brow presentation. In the remaining 3 cases, the orbits were above the pubis, and sinciput presentation was inferred. Head deflexion was diagnosed more accurately with ultrasound than clinically and always required a cesarean section versus 36% of cases with OP flexed presentation (p = 0.0052). CONCLUSIONS: Fetuses with abnormal labor and OP rotation had deflexed presentations in 14% of cases and were never delivered vaginally. Sonography was far more accurate than the digital examination.


Assuntos
Apresentação no Trabalho de Parto , Ultrassonografia Pré-Natal , Feminino , Humanos , Gravidez , Estudos Retrospectivos
11.
Fetal Diagn Ther ; 42(3): 198-203, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28237993

RESUMO

OBJECTIVES: To compare the accuracy of the INTERGROWTH-21st (IG-21) with the Italian Society of Ultrasound in Obstetrics and Gynecology (SIEOG) abdominal circumference (AC) standards in the detection of small-for-gestational-age (SGA) fetuses in a high-risk population. MATERIAL AND METHODS: Our study included all pregnant patients with an increased risk of placental insufficiency that were seen in two Italian university hospitals between 2014 and 2015. The accuracy of IG-21 and SIEOG AC standards in the detection of SGA neonates was analyzed by means of the area under the receiver operating characteristic curve (ROC-AUC) at 4 gestational age intervals (24-27, 28-31, 32-35, >35 weeks). RESULTS: We enrolled 428 patients (278 Italians). There was no significant difference between the ROC-AUC of AC according to IG-21 and SIEOG standards for all birthweight thresholds and gestational intervals that were considered. The diagnostic performance was similar in Italian and non-Italian patients. The accuracy was, however, limited, with values of ROC-AUC ranging between 0.80 and 0.89. CONCLUSIONS: The IG-21 and SIEOG AC standards are interchangeable for the diagnosis of SGA fetuses. The diagnostic accuracy is, however, limited. We provide figures that can be used to stratify the probability that an infant will be SGA in an obstetric population at increased risk of growth restriction.


Assuntos
Abdome/diagnóstico por imagem , Recém-Nascido Pequeno para a Idade Gestacional , Ultrassonografia Pré-Natal/normas , Abdome/embriologia , Abdome/crescimento & desenvolvimento , Desenvolvimento Fetal , Idade Gestacional , Humanos , Itália
12.
J Matern Fetal Neonatal Med ; : 1-5, 2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-27050886

RESUMO

OBJECTIVES: To assess the reliability of a new three-dimensional (3D) ultrasound technique for the measurement of the subpubic arch angle (SPA) and the agreement between two contrast-enhancing 3D ultrasound techniques. METHODS: We acquired two static 3D transperineal volumes from 72 nulliparous women using two ultrasound machines equipped with two different 3D contrast enhancement and linear reconstruction softwares: 1. Oblique View Extended Imaging with HD-Volume Imaging (OVIX-HDVI™), Samsung; 2. Omniview with Volume Contrast Imaging (Omniview-VCI™), GE Healthcare. An operator measured SPA once by OVIX-HDVI, and twice by Omniview-VCI, while another operator measured SPA once by Omniview-VCI. We evaluated intra- and inter-observer reproducibility of Omniview-VCI and intermethod agreement. Reproducibility and intermethod agreement were studied by means of intraclass correlation coefficient (ICC) and Bland-Altman method. RESULTS: Omniview-VCI SPA measurements showed excellent intraobserver and interobserver reproducibility (ICC 0.970; 95% C.I. 0.952 to 0.981, 0.932; 95% C.I. 0.893 to 0.957, respectively). Furthermore, Omniview VCI SPA measurements demonstrated excellent agreement with those performed by OVIX-HDVI technique (ICC 0.943; 95 C.I. 0.911 to 0.964). No systematic difference was found in any of the reliability studies. CONCLUSIONS: OmniView-VCI is a reliable method for SPA assessment. Both OmniView-VCI and OVIX-HDVI can be used interchangeably for SPA measurement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...