Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Acoust Soc Am ; 148(6): 3562, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33379897

RESUMO

Wearing face masks (alongside physical distancing) provides some protection against infection from COVID-19. Face masks can also change how people communicate and subsequently affect speech signal quality. This study investigated how three common face mask types (N95, surgical, and cloth) affected acoustic analysis of speech and perceived intelligibility in healthy subjects. Acoustic measures of timing, frequency, perturbation, and power spectral density were measured. Speech intelligibility and word and sentence accuracy were also examined using the Assessment of Intelligibility of Dysarthric Speech. Mask type impacted the power distribution in frequencies above 3 kHz for the N95 mask, and above 5 kHz in surgical and cloth masks. Measures of timing and spectral tilt mainly differed with N95 mask use. Cepstral and harmonics to noise ratios remained unchanged across mask type. No differences were observed across conditions for word or sentence intelligibility measures; however, accuracy of word and sentence translations were affected by all masks. Data presented in this study show that face masks change the speech signal, but some specific acoustic features remain largely unaffected (e.g., measures of voice quality) irrespective of mask type. Outcomes have bearing on how future speech studies are run when personal protective equipment is worn.


Assuntos
COVID-19/prevenção & controle , Máscaras/efeitos adversos , Acústica da Fala , Inteligibilidade da Fala , Adulto , Feminino , Humanos , Masculino , SARS-CoV-2 , Qualidade da Voz , Adulto Jovem
2.
J Acoust Soc Am ; 148(3): 1436, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-33003843

RESUMO

Vowel space (VS) measurements can provide objective information on formant distribution and act as a proxy for vowel production. There are a number of proposed ways to quantify vowel production clinically, including vowel space area, formant centralization ratio, and vowel articulation index (VAI). The stability, reliability, and sensitivity of three VS measurements were investigated in two experiments. Stability was explored across three inter-recording intervals and challenged in two sensitivity conditions. Data suggest that VAI is the most stable measure across 30 s, 2 h, and 4 h inter-recording intervals. VAI appears the most sensitive metric of the three measures in conditions of fatigue and noise. These analyses highlight the need for stability and sensitivity analysis when developing and validating acoustic metrics, and underscore the potential of the VAI for vowel analysis.


Assuntos
Acústica , Acústica da Fala , Fonética , Reprodutibilidade dos Testes
3.
Neurology ; 89(8): 837-844, 2017 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-28733335

RESUMO

OBJECTIVE: To provide a comprehensive description of motor speech function in behavioral variant frontotemporal dementia (bvFTD). METHODS: Forty-eight individuals (24 bvFTD and 24 age- and sex-matched healthy controls) provided speech samples. These varied in complexity and thus cognitive demand. Their language was assessed using the Progressive Aphasia Language Scale and verbal fluency tasks. Speech was analyzed perceptually to describe the nature of deficits and acoustically to quantify differences between patients with bvFTD and healthy controls. Cortical thickness and subcortical volume derived from MRI scans were correlated with speech outcomes in patients with bvFTD. RESULTS: Speech of affected individuals was significantly different from that of healthy controls. The speech signature of patients with bvFTD is characterized by a reduced rate (75%) and accuracy (65%) on alternating syllable production tasks, and prosodic deficits including reduced speech rate (45%), prolonged intervals (54%), and use of short phrases (41%). Groups differed on acoustic measures derived from the reading, unprepared monologue, and diadochokinetic tasks but not the days of the week or sustained vowel tasks. Variability of silence length was associated with cortical thickness of the inferior frontal gyrus and insula and speech rate with the precentral gyrus. CONCLUSIONS: One in 8 patients presented with moderate speech timing deficits with a further two-thirds rated as mild or subclinical. Subtle but measurable deficits in prosody are common in bvFTD and should be considered during disease management. Language function correlated with speech timing measures derived from the unprepared monologue only.


Assuntos
Demência Frontotemporal/fisiopatologia , Demência Frontotemporal/psicologia , Destreza Motora , Fala , Córtex Cerebral/diagnóstico por imagem , Feminino , Demência Frontotemporal/diagnóstico por imagem , Humanos , Teste de Tolerância a Lactose , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Fenótipo , Medida da Produção da Fala
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...