Eur Arch Otorhinolaryngol ; 279(10): 4655-4665, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35048175

RESUMO

PURPOSE: Electrocochleography (ECochG) measures electrical potentials generated by the inner ear in response to acoustic stimulation. Real-time (rt) recordings are increasingly used during cochlear implant (CI) surgeries to monitor the inner ear function. However, the performance of rt-ECochG is a delicate measurement procedure involving several pitfalls, which lead to inaccurate or invalid signal recordings in up to 20%. In order to use the technique routinely in CI candidates, an improvement in measurement reliability must be achieved. METHODS: In our prospective study, we systematically investigated potential pitfalls and error sources during rt-ECochG recordings. We performed experiments (i) on a head and torso simulator, (ii) on a whole-head cadaver specimen, (iii) as well as in vivo during rt-ECochG recordings in CI recipients. After analyzing experiments i-iii, a standardized measurement procedure was developed. We followed this guideline in 10 CI recipients to test the measurement reliability. RESULTS: Besides improper installation, surgical and patient-specific factors influenced the measured signal. In particular, the unattenuated presentation of the acoustic stimulus was of importance. We summarized our findings in a standardized guideline. Following this guideline, we measured successful intraoperative ECochG recordings in 9/10 patients. CONCLUSIONS: Our error analysis improved the understanding of successful rt-ECochG measurements. When following our proposed guideline, we achieved more reliable intraoperative ECochG recordings.


Assuntos
Implante Coclear , Implantes Cocleares , Audiometria de Resposta Evocada/métodos , Cóclea/cirurgia , Implante Coclear/métodos , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
J Acoust Soc Am ; 150(2): 673, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34470279

RESUMO

Typically, the coding strategies of cochlear implant audio processors discard acoustic temporal fine structure information (TFS), which may be related to the poor perception of interaural time differences (ITDs) and the resulting reduced spatial hearing capabilities compared to normal-hearing individuals. This study aimed to investigate to what extent bilateral cochlear implant (BiCI) recipients can exploit ITD cues provided by a TFS preserving coding strategy (FS4) in a series of sound field spatial hearing tests. As a baseline, we assessed the sensitivity to ITDs and binaural beats of 12 BiCI subjects with a coding strategy disregarding fine structure (HDCIS) and the FS4 strategy. For 250 Hz pure-tone stimuli but not for broadband noise, the BiCI users had significantly improved ITD discrimination using the FS4 strategy. In the binaural beat detection task and the broadband sound localization, spatial discrimination, and tracking tasks, no significant differences between the two tested coding strategies were observed. These results suggest that ITD sensitivity did not generalize to broadband stimuli or sound field spatial hearing tests, suggesting that it would not be useful for real-world listening.


Assuntos
Implante Coclear , Implantes Cocleares , Localização de Som , Estimulação Acústica , Audição , Testes Auditivos , Humanos
3.
Trends Hear ; 25: 2331216520986303, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33663298

RESUMO

Residual inhibition, that is, the temporary suppression of tinnitus loudness after acoustic stimulation, is a frequently observed phenomenon that may have prognostic value for clinical applications. However, it is unclear in which subjects residual inhibition is more likely and how stable the effect of inhibition is over multiple repetitions. The primary aim of this work was to evaluate the effect of hearing loss and tinnitus chronicity on residual inhibition susceptibility. The secondary aim was to investigate the short-term repeatability of residual inhibition. Residual inhibition was assessed in 74 tinnitus subjects with 60-second narrow-band noise stimuli in 10 consecutive trials. The subjects were assigned to groups according to their depth of suppression (substantial residual inhibition vs. comparator group). In addition, a categorization in normal hearing and hearing loss groups, related to the degree of hearing loss at the frequency corresponding to the tinnitus pitch, was made. Logistic regression was used to identify factors associated with susceptibility to residual inhibition. Repeatability of residual inhibition was assessed using mixed-effects ordinal regression including poststimulus time and repetitions as factors. Tinnitus chronicity was not associated with residual inhibition for subjects with hearing loss, while a statistically significant negative association between tinnitus chronicity and residual inhibition susceptibility was observed in normal hearing subjects (odds ratio: 0.63; p = .0076). Moreover, repeated states of suppression can be stably induced, reinforcing the use of residual inhibition for within-subject comparison studies.


Assuntos
Perda Auditiva , Zumbido , Estimulação Acústica , Perda Auditiva/diagnóstico , Testes Auditivos , Humanos , Ruído , Zumbido/diagnóstico , Zumbido/terapia
4.
Eur Arch Otorhinolaryngol ; 278(11): 4321-4328, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33661356

RESUMO

PURPOSE: Hereditary hemorrhagic telangiectasia (HHT) is a vascular disorder that presents with recurrent, intractable epistaxis. The aim of this study was to retrospectively analyze the efficacy of various treatment options for epistaxis in patients with HHT, over a period of 18 years, and to correlate these findings with available evidence in the literature. METHODS: Records of patients with HHT, treated for epistaxis between 2000 and 2018 were analyzed. Treatment procedures carried out and their efficacy were extracted and analyzed. RESULTS: Forty-three records were evaluated. All patients were given nasal humidifying ointments, 93% required acute treatment with bipolar electrocautery, and 60% underwent atraumatic nasal packing. Recurrent cases were treated medically with tranexamic acid (26%), oestrogen (19%), and bevacizumab (2%). Laser photocoagulation was done in selected cases (40%) and if unsuccessful, septal dermoplasty was performed (2.3%). Endovascular embolization was reserved for life-threatening emergencies (7%). CONCLUSION: Epistaxis in HHT is not curable, but can be managed by employing a comprehensive stepwise approach. An algorithm for effective and comprehensive management has been presented.


Assuntos
Epistaxe , Telangiectasia Hemorrágica Hereditária , Bevacizumab , Epistaxe/cirurgia , Epistaxe/terapia , Humanos , Fotocoagulação , Estudos Retrospectivos , Telangiectasia Hemorrágica Hereditária/complicações , Telangiectasia Hemorrágica Hereditária/terapia
5.
HNO ; 68(10): 763-772, 2020 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-32221628

RESUMO

BACKGROUND: Although vestibular symptoms are amongst the most frequent reasons for seeking emergency medical help, many patients remain undiagnosed. OBJECTIVE: In this cross-sectional study, we investigated the spectrum of vertigo and dizziness in a tertiary ear, nose, and throat (ENT) emergency department (ED). Furthermore, we investigated the attendant symptoms, clinical signs, and the diagnostic tests performed. METHODS: We screened all ED reports from 01/2013 to 12/2013 for adult patients with vestibular symptoms referred to the ENT department. RESULTS: In total, we found 2596 cases with reported vestibular symptoms in the ED as a main or accompanying complaint. Of these, 286 were referred to the ENT specialist directly (n = 98) or via other major medical specialties (n = 188). Benign paroxysmal positional vertigo (BPPV) was the most frequent diagnosis in our study (n = 46, 16.1%), followed by vestibular neuritis (n = 44, 15.4%), otitis media (n = 20, 7%), and 9 patients (3.1%) had an ischemic stroke or a transient ischemic attack. In 70 (24.5%) cases, dizziness was not further specified. CONCLUSION: BPPV is the most frequent diagnosis seen in the ED; however, physicians need to document nystagmus more precisely and perform diagnostic tests systematically, in order to make an accurate diagnosis. To avoid misdiagnoses, ED physicians and ENT specialists should be able to recognize central signs in patients with an acute vestibular syndrome. Every fourth patient does not receive a definitive diagnosis. Diagnostic ED workup for patients with dizziness needs further improvement.


Assuntos
Vertigem Posicional Paroxística Benigna , Tontura , Aceitação pelo Paciente de Cuidados de Saúde , Faringe , Adulto , Vertigem Posicional Paroxística Benigna/diagnóstico , Vertigem Posicional Paroxística Benigna/etiologia , Estudos Transversais , Tontura/diagnóstico , Tontura/etiologia , Serviço Hospitalar de Emergência , Humanos
8.
Int J Comput Assist Radiol Surg ; 14(1): 83-92, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30073453

RESUMO

PURPOSE: To evaluate the accuracy and reliability of image-based safety analysis for robotic cochlear implantation (RCI) in an ex vivo assessment. METHODS: The accuracy was evaluated in a study on 23 human temporal bones. For image analysis, a computer-assisted safety analysis based on intraoperative cone beam computed tomography was implemented. The method automatically segments the drill tunnel and predicts the distance between the tunnel and the facial nerve. In addition, the drilling error at the target is predicted. The predicted distances were compared with the actually drilled distances measured in postoperative high-resolution micro-computed tomography scans. The automatic method was compared to accuracies associated with a manual analysis of the image data. RESULTS: The presented computerized image-based analysis enabled the proximity of the facial nerve to the drill trajectory to be predicted with an accuracy of 0.22 ± 0.15 mm and drilling error at the target to be predicted with an accuracy of 0.11 mm ± 0.08 during N = 19 RCI procedures. The manual assessment of facial nerve proximity was performed with an accuracy of 0.34 ± 0.20 mm by a trained clinical expert. CONCLUSION: The assessment of intraoperative CT-based imaging presents multiple benefits over alternative safety mechanisms including early detection and applicability even in cases of malformation of the mastoid. This work presents a computer-assisted approach to image analysis that enables procedure safety measurements to be reliably performed with superior accuracy to other proposed safety methodologies, at a safe distance from the facial nerve. Its application must, however, be considered in relation to associated costs (time, cost, irradiation) and the dependence of the measure on a reliable preoperative segmentation.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Assistida por Computador/métodos , Osso Temporal/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Osso Temporal/cirurgia , Microtomografia por Raio-X
9.
Sci Robot ; 2(4)2017 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-30246168

RESUMO

Surgical robot systems can work beyond the limits of human perception, dexterity and scale making them inherently suitable for use in microsurgical procedures. However, despite extensive research, image-guided robotics applications for microsurgery have seen limited introduction into clinical care to date. Among others, challenges are geometric scale and haptic resolution at which the surgeon cannot sufficiently control a device outside the range of human faculties. Mechanisms are required to ascertain redundant control on process variables that ensure safety of the device, much like instrument-flight in avionics. Cochlear implantation surgery is a microsurgical procedure, in which specific tasks are at sub-millimetric scale and exceed reliable visuo-tactile feedback. Cochlear implantation is subject to intra- and inter-operative variations, leading to potentially inconsistent clinical and audiological outcomes for patients. The concept of robotic cochlear implantation aims to increase consistency of surgical outcomes such as preservation of residual hearing and reduce invasiveness of the procedure. We report successful image-guided, robotic CI in human. The robotic treatment model encompasses: computer-assisted surgery planning, precision stereotactic image-guidance, in-situ assessment of tissue properties and multipolar neuromonitoring (NM), all based on in vitro, in vivo and pilot data. The model is expandable to integrate additional robotic functionalities such as cochlear access and electrode insertion. Our results demonstrate the feasibility and possibilities of using robotic technology for microsurgery on the lateral skull base. It has the potential for benefit in other microsurgical domains for which there is no task-oriented, robotic technology available at present.

11.
HNO ; 64(9): 625-9, 2016 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-27138367

RESUMO

Over the past years, the multidisciplinary character of the international Computer-Aided Surgery around the Head (CAS-H) symposium has advanced many medical technologies, which were often adopted by industry. In Bern, the synergetic effects of the CAS-H symposium have enabled many experiences and developments in the area of computer-aided surgery. Planning and simulation methods in the areas of craniomaxillofacial surgery and otorhinolaryngology were developed and tested in clinical settings. In the future, further CAS-H symposia should follow, in order to promote the possibilities and applications of computer-assisted surgery around the head.


Assuntos
Cabeça/cirurgia , Treinamento com Simulação de Alta Fidelidade/tendências , Procedimentos Cirúrgicos Otorrinolaringológicos/tendências , Cuidados Pré-Operatórios/tendências , Procedimentos Cirúrgicos Robóticos/tendências , Cirurgia Assistida por Computador/tendências , Humanos , Suíça
12.
Int J Pediatr Otorhinolaryngol ; 79(12): 2348-54, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26596357

RESUMO

OBJECTIVE: Cochlear implants (CI) are standard treatment for prelingually deafened children and postlingually deafened adults. Computed tomography (CT) is the standard method for postoperative imaging of the electrode position. CT scans accurately reflect electrode depth and position, which is essential prior to use. However, routine CT examinations expose patients to radiation, which is especially problematic in children. We examined whether new CT protocols could reduce radiation doses while preserving diagnostic accuracy. METHODS: To investigate whether electrode position can be assessed by low-dose CT protocols, a cadaveric lamb model was used because the inner ear morphology is similar to humans. The scans were performed at various volumetric CT dose-indexes CTDIvol)/kV combinations. For each constant CTDIvol the tube voltage was varied (i.e., 80, 100, 120 and 140kV). This procedure was repeated at different CTDIvol values (21mGy, 11mGy, 5.5mGy, 2.8mGy and 1.8mGy). To keep the CTDIvol constant at different tube voltages, the tube current values were adjusted. Independent evaluations of the images were performed by two experienced and blinded neuroradiologists. The criteria diagnostic usefulness, image quality and artifacts (scaled 1-4) were assessed in 14 cochlear-implanted cadaveric lamb heads with variable tube voltages. RESULTS: Results showed that the standard CT dose could be substantially reduced without sacrificing diagnostic accuracy of electrode position. The assessment of the CI electrode position was feasible in almost all cases up to a CTDIvol of 2-3mGy. The number of artifacts did not increase for images within this dose range as compared to higher dosages. The extent of the artifacts caused by the implanted metal-containing CI electrode does not depend on the radiation dose and is not perceptibly influenced by changes in the tube voltage. Summarizing the evaluation of the CI electrode position is possible even at a very low radiation dose. CONCLUSIONS: CT imaging of the temporal bone for postoperative electrode position control of the CI is possible with a very low and significantly radiation dose. The tube current-time product and voltage can be reduced by 50% without increasing artifacts. Low-dose postoperative CT scans are sufficient for localizing the CI electrode.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Tomografia Computadorizada de Feixe Cônico/métodos , Orelha Interna/diagnóstico por imagem , Doses de Radiação , Animais , Artefatos , Eletrodos , Masculino , Período Pós-Operatório , Ovinos
13.
Eur Arch Otorhinolaryngol ; 272(10): 2749-54, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25209434

RESUMO

A retrospective evaluation of glass ionomer cement (GIC) in middle ear surgery with emphasis on short- and long-term safety was conducted at the tertiary referral center. GIC was applied between 1995 and 2006 in 444 patients in otologic surgery. Technical aspects, safety, benefits and complications due to GIC were analysed until 2011 (follow-up 5-16 years; mean 10 years). GIC was applied in stapes surgery (228 primary, 92 revisions), cochlear implants (108) and implantable hearing aids (7), ossiculoplasty (7), for coverage of opened mastoid air cells towards the external ear canal (1) and inner ear fistula closure (1). GIC turned out to be very handy in stapes surgery for optimal prosthesis fixation at the incus (260) and on the malleus handle (60) without complications. Results suggest that GIC may diminish the danger of incus necrosis in primary stapedotomy. In cochlear implants and implantable hearing aids, GIC was used for casing alone (74), casing and electrode fixation (27) and electrode alone fixation (14). Inflammatory reactions were observed in five cases (4.3%), mostly after trauma. Broken cement fragments appeared to promote foreign body rejection. In seven cases an incudo-stapedial gap was repaired with GIC with excellent hearing gain; in three cases (43%) revision surgery was needed due to cement breakage. In one case, GIC was applied for a watertight coverage of opened mastoid cells, and in the other for fistula closure of the lateral semi-circular canal over cartilage, covered with bone pathé; follow-up was uneventful. Targeted use of GIC in middle ear surgery rarely poses problems. GIC cannot be used in neuro-otosurgery in contact with cerebrospinal fluid because of possible aluminium encephalopathy.


Assuntos
Previsões , Cimentos de Ionômeros de Vidro , Perda Auditiva Condutiva/cirurgia , Audição/fisiologia , Bigorna/cirurgia , Martelo/cirurgia , Microcirurgia/métodos , Cirurgia do Estribo/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Perda Auditiva Condutiva/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Adulto Jovem
14.
Eur Arch Otorhinolaryngol ; 271(6): 1369-74, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23640386

RESUMO

Surgical plugging and resurfacing are well established treatments of superior semicircular canal dehiscence, while capping with hydroxyapatite cement has been little discussed in literature. The aim of this study was to prove the efficacy of the capping technique. Charts of patients diagnosed with superior semicircular canal dehiscence were reviewed retrospectively. All patients answered the dizziness handicap inventory, a survey analyzing the impact of their symptoms on their quality of life. Capping of the dehiscent canal was performed via the middle fossa approach in all cases. Ten out of 22 patients diagnosed with superior semicircular canal dehiscence were treated with surgical capping, nine of which were included in this study. No major perioperative complications occurred. In 8 out of 9 (89%) patients, capping led to a satisfying reduction of the main symptoms. One patient underwent revision surgery 1 year after the initial intervention. Scores in the dizziness handicap inventory were lower in the surgically treated group than in the non-surgically treated group, but results were not statistically significant (P = 0.45). Overall, capping is a safe and efficient alternative to plugging and resurfacing of superior semicircular canal dehiscence.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Hidroxiapatitas/uso terapêutico , Hiperacusia/cirurgia , Doenças do Labirinto/cirurgia , Canais Semicirculares/cirurgia , Vertigem/cirurgia , Adulto , Audiometria de Tons Puros , Estudos de Coortes , Feminino , Humanos , Hiperacusia/etiologia , Doenças do Labirinto/complicações , Doenças do Labirinto/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Canais Semicirculares/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Vertigem/etiologia , Potenciais Evocados Miogênicos Vestibulares , Adulto Jovem
15.
Acta Otolaryngol Suppl ; (564): 3-13, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24328756

RESUMO

CONCLUSION: The comprehensive Hearing Preservation classification system presented in this paper is suitable for use for all cochlear implant users with measurable pre-operative residual hearing. If adopted as a universal reporting standard, as it was designed to be, it should prove highly beneficial by enabling future studies to quickly and easily compare the results of previous studies and meta-analyze their data. OBJECTIVES: To develop a comprehensive Hearing Preservation classification system suitable for use for all cochlear implant users with measurable pre-operative residual hearing. METHODS: The HEARRING group discussed and reviewed a number of different propositions of a HP classification systems and reviewed critical appraisals to develop a qualitative system in accordance with the prerequisites. RESULTS: The Hearing Preservation Classification System proposed herein fulfills the following necessary criteria: 1) classification is independent from users' initial hearing, 2) it is appropriate for all cochlear implant users with measurable pre-operative residual hearing, 3) it covers the whole range of pure tone average from 0 to 120 dB; 4) it is easy to use and easy to understand.


Assuntos
Audiometria de Tons Puros , Limiar Auditivo , Implante Coclear , Implantes Cocleares , Consenso , Humanos
17.
Rhinology ; 50(3): 246-54, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22888480

RESUMO

BACKGROUND: The aim of this multicentre study was to systematically analyse the strengths and weaknesses in the surgical training for endoscopic sinus surgery (ESS) and identify measures that may improve training. METHODOLOGY: Using a structured questionnaire, 133 participants of ESS courses in seven centres in Germany, Switzerland and Australia were asked about their experiences during their dissection courses and how they perceived their course could be improved. RESULTS: Gaining confidence in handling of instruments and endoscopes was only a problem for participants with little experience in ESS. The majority of the participants, independent from their level of training, considered infundibulotomy and anterior ethmoidectomy as the easiest dissection steps, whilst surgery of the frontal sinus posed a considerable challenge for many surgeons even those with a higher level of training. Participants with and without ESS experience thought that emphasis on anatomy was the most important improvement that could be made during their surgical training. Virtually all participants stated that the course improved their anatomical knowledge, their surgical skills and their confidence when performing ESS. CONCLUSIONS: ESS dissection courses are considered beneficial by surgical trainees. Participants felt that more emphasis on sinus anatomy in conjunction with private study is essential to maximize their skills in surgical dissection. For beginners with ESS, an infundibulotomy and anterior ethmoidectomy were thought to be the best initial procedures to help develop endoscopic surgical skills.


Assuntos
Competência Clínica , Currículo , Educação de Pós-Graduação em Medicina/organização & administração , Endoscopia/educação , Otolaringologia/educação , Seios Paranasais/cirurgia , Adulto , Austrália , Cadáver , Dissecação/educação , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Suíça
18.
Int J Pediatr Otorhinolaryngol ; 75(11): 1359-63, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21872347

RESUMO

Antrochoanal polyps are hyperplasias of the nasal mucosa, which have their origin in the maxillary sinus and extend through the nasal cavity and the choanae into the naso- and oropharynx. In children antrochoanal polyps represent one of the more frequent manifestations of paediatric nasal polyposis. Most studies on antrochoanal polyps in children report only on nasal obstruction, hyponasal speech and snoring, which are also encountered in the most common cause of obstructive sleep apnoea syndrome; i.e. adenoid or tonsillar hyperplasia. Only very few studies report on additional health hazards by antrochoanal polyps ranging from obstructive sleep apnoea syndrome to swallowing disorders and cachexia. We present the case of an 8 year old girl with a bicycle accident caused by excessive daytime sleepiness and obstructive sleep apnoea syndrome due to an extensive antrochoanal polyp. After a transnasal polypectomy and meatotomy type II the obstructive sleep apnoea and day time sleepiness resolved completely. Awareness of this additional health hazard is important and correct evaluation and timely diagnosis of a potential antrochoanal polyp is mandatory because minimally invasive rhinosurgery is highly curative in preventing further impending problems.


Assuntos
Obstrução Nasal/cirurgia , Pólipos Nasais/cirurgia , Síndromes da Apneia do Sono/complicações , Acidentes de Trânsito , Ciclismo/lesões , Criança , Endoscopia/métodos , Feminino , Seguimentos , Humanos , Obstrução Nasal/complicações , Obstrução Nasal/diagnóstico , Pólipos Nasais/complicações , Pólipos Nasais/diagnóstico , Nasofaringe/cirurgia , Medição de Risco , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/cirurgia , Resultado do Tratamento
20.
Eur Arch Otorhinolaryngol ; 268(10): 1463-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21559809

RESUMO

Balloon sinuplasty is a tool that is used to treat selected patients with paranasal sinus pathologies. No studies have investigated the aetiology of failed access to the frontal sinus. The aim of our study was to specify the intraoperative technical failure rate and to analyse the aetiology of the failed access to predict potential technical difficulties before surgery. We retrospectively analysed the charts of patients who underwent balloon sinuplasty from November 2007 to July 2010 at three different ENT-Centres. CT-analysis of the patients with failed access was performed. Of the 104 frontal sinuses, dilation of 12 (12%) sinuses failed. The anatomy of all failed cases revealed variations in the frontal recess (frontoethmoidal-cell, frontal-bulla-cell or agger-nasi-cell) or osteoneogenesis. In one patient, a lymphoma was overlooked during a balloon only procedure. The lymphoma was diagnosed 6 months later with a biopsy during functional endoscopic sinus surgery. In complex anatomical situations of the frontal recess, balloon sinuplasty may be challenging or impossible. In these situations, it is essential to have knowledge of classical functional endoscopic sinus surgery of the frontal recess area. The drawbacks of not including a histopathologic exam should be considered in balloon only procedures.


Assuntos
Cateterismo/métodos , Seio Frontal/cirurgia , Sinusite Frontal/cirurgia , Adolescente , Adulto , Idoso , Diagnóstico Diferencial , Endoscopia/métodos , Feminino , Seguimentos , Sinusite Frontal/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem