Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Eur Arch Otorhinolaryngol ; 281(4): 1781-1787, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37943315

RESUMO

OBJECTIVES: To assess the prevalence of new hearing losses in patients with acute vestibular syndrome (AVS) and to start to evaluate its diagnostic value for the differentiation between peripheral and central causes. DESIGN: We performed a cross-sectional prospective study in AVS patients presenting to our Emergency Department (ED) from February 2015 to November 2020. All patients received an MRI, Head-impulse test, Nystagmus test and Test of skew ('HINTS'), caloric testing and a pure-tone audiometry. RESULTS: We assessed 71 AVS patients, 17 of whom had a central and 54 a peripheral cause of dizziness. 12.7% had an objective hearing loss. 'HINTS' had an accuracy of 78.9% to diagnose stroke, whereas 'HINTS' plus audiometry 73.2%. 'HINTS' sensitivity was 82.4% and specificity 77.8% compared to 'HINTS' plus audiometry showing a sensitivity of 82.4% and specificity of 70.4%. The four patients with stroke and minor stroke had all central 'HINTS'. 55% of the patients did not perceive their new unilateral hearing loss. CONCLUSIONS: We found that almost one-eighth of the AVS patients had a new onset of hearing loss and only half had self-reported it. 'HINTS' plus audiometry proved to be less accurate to diagnose a central cause than 'HINTS' alone. Audiometry offered little diagnostic accuracy to detect strokes in the ED but might be useful to objectify a new hearing loss that was underestimated in the acute phase. Complete hearing loss should be considered a red flag, as three in four patients suffered from a central cause.


Assuntos
Surdez , Perda Auditiva , Nistagmo Patológico , Acidente Vascular Cerebral , Humanos , Estudos Transversais , Prevalência , Estudos Prospectivos , Vertigem/etiologia , Náusea/complicações , Vômito/complicações , Perda Auditiva/diagnóstico , Perda Auditiva/epidemiologia , Doença Aguda , Acidente Vascular Cerebral/complicações , Nistagmo Patológico/diagnóstico
2.
J Vestib Res ; 34(1): 49-61, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38160379

RESUMO

OBJECTIVE: A normal video Head Impulse Test is the gold standard in the emergency department to rule-in patients with an acute vestibular syndrome and a stroke. We aimed to compare the diagnostic accuracy of vHIT metrics regarding the vestibulo-ocular reflex gain and the corrective saccades in detecting vestibular strokes. METHODS: Prospective cross-sectional study (convenience sample) of patients presenting with acute vestibular syndrome in the emergency department of a tertiary referral centre between February 2015 and May 2020. We screened 1677 patients and enrolled 76 patients fulfilling the inclusion criteria of acute vestibular syndrome. All patients underwent video head impulse test with automated and manual data analysis. A delayed MRI served as a gold standard for vestibular stroke confirmation. RESULTS: Out of 76 patients, 52 were diagnosed with acute unilateral vestibulopathy and 24 with vestibular strokes. The overall accuracy of detecting stroke with an automated vestibulo-ocular reflex gain was 86.8%, compared to 77.6% for cumulative saccade amplitude and automatic saccade mean peak velocity measured by an expert and 71% for cumulative saccade amplitude and saccade mean peak velocity measured automatically. Gain misclassified 13.1% of the patients as false positive or false negative, manual cumulative saccade amplitude and saccade mean peak velocity 22.3%, and automated cumulative saccade amplitude and saccade mean peak velocity 28.9% respectively. CONCLUSIONS: We found a better accuracy of video head impulse test for the diagnosis of vestibular strokes when using the vestibulo-ocular reflex gain than using saccade metrics. Nevertheless, saccades provide an additional and important information for video head impulse test evaluation. The automated saccade detection algorithm is not yet perfect compared to expert analysis, but it may become a valuable tool for future non-expert video head impulse test evaluations.


Assuntos
Movimentos Sacádicos , Acidente Vascular Cerebral , Humanos , Reflexo Vestíbulo-Ocular , Estudos Prospectivos , Estudos Transversais , Teste do Impulso da Cabeça , Vertigem/diagnóstico , Acidente Vascular Cerebral/diagnóstico
3.
Artigo em Inglês | MEDLINE | ID: mdl-38083665

RESUMO

Our study aims to provide basic insights on the impact of the spiral shape of the cochlea, i.e., of geometric torsion and curvature, on wall pressure and wall shear stress. We employed computational fluid dynamics in square duct models with curvature and torsion similar to those found in human cochleae. The results include wall pressures and wall shear stresses within the ducts under oscillating axial flow. Our findings indicate that the helical shape generates higher transverse wall shear stresses compared to exclusively curved or twisted ducts. The wall pressures and transverse wall shear stresses we found rise to amounts that may be physiologically relevant in the cochlea.Clinical relevance- The role of the spiral shape of the cochlea in hearing physiology remains, for a large part, elusive. For a better apprehension of hearing and its disorders, it is important to investigate the influence of geometric properties on biofluids motion and emerging phenomena in the cochlea.


Assuntos
Cóclea , Audição , Humanos , Movimento (Física)
4.
Front Neurol ; 14: 1231403, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745650

RESUMO

Aim: This study aimed to compare the effectiveness of auditory brainstem response (ABR) and extracochlear electrocochleography (ECochG) in objectively evaluating the coupling efficiency of floating mass transducer (FMT) placement during active middle ear implant (AMEI) surgery. Methods: We enrolled 15 patients (mean age 58.5 ± 19.4 years) with mixed hearing loss who underwent AMEI implantation (seven ossicular chain and eight round window couplings). Before the surgical procedure, an audiogram was performed. We utilized a clinical measurement system to stimulate and record intraoperative ABR and ECochG recordings. The coupling efficiency of the VSB was evaluated through ECochG and ABR threshold measurements. Postoperatively, we conducted an audiogram and a vibrogram. Results: In all 15 patients, ABR threshold testing successfully determined intraoperative coupling efficiency, while ECochG was successful in only eight patients. In our cohort, ABR measurements were more practical, consistent, and robust than ECochG measurements. Coupling efficiency, calculated as the difference between vibrogram thresholds and postoperative bone conduction thresholds, was found to be more accurately predicted by ABR measurements (p = 0.016, R2 = 0.37) than ECochG measurements (p = 0.761, R2 = 0.02). We also found a non-significant trend toward better results with ossicular chain coupling compared to round window coupling. Conclusion: Our findings suggest that ABR measurements are more practical, robust, and consistent than ECochG measurements for determining coupling efficiency during FMT placement surgery. The use of ABR measurements can help to identify the optimal FMT placement, especially with round window coupling. Finally, we offer normative data for both techniques, which can aid other clinical centers in using intraoperative monitoring for AMEI placement.

5.
J Vis Exp ; (193)2023 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-36939227

RESUMO

Strong magnetic fields induce dizziness, vertigo, and nystagmus due to Lorentz forces acting on the cupula in the semi-circular canals, an effect called magnetic vestibular stimulation (MVS). In this article, we present an experimental setup in a 7T MRT scanner (MRI scanner) that allows the investigation of the influence of strong magnetic fields on nystagmus as well as perceptual and cognitive responses. The strength of MVS is manipulated by altering the head positions of the participants. The orientation of the participants' semicircular canals with respect to the static magnetic field is assessed by combining a 3D magnetometer and 3D constructive interference in steady-state (3D-CISS) images. This approach allows to account for intra- and inter-individual differences in participants' responses to MVS. In the future, MVS can be useful for clinical research, for example, in the investigation of compensatory processes in vestibular disorders. Furthermore, it could foster insights into the interplay between vestibular information and cognitive processes in terms of spatial cognition and the emergence of self-motion percepts under conflicting sensory information. In fMRI studies, MVS can elicit a possible confounding effect, especially in tasks influenced by vestibular information or in studies comparing vestibular patients with healthy controls.


Assuntos
Percepção de Movimento , Vestíbulo do Labirinto , Humanos , Vestíbulo do Labirinto/diagnóstico por imagem , Vestíbulo do Labirinto/fisiologia , Campos Magnéticos , Canais Semicirculares/diagnóstico por imagem , Canais Semicirculares/fisiologia , Vertigem , Cognição
6.
BMJ Open ; 13(3): e064057, 2023 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-36963793

RESUMO

OBJECTIVES: We aimed to determine the frequency of vestibular syndromes, diagnoses, diagnostic errors and resources used in patients with dizziness in the emergency department (ED). DESIGN: Retrospective cross-sectional study. SETTING: Tertiary referral hospital. PARTICIPANTS: Adult patients presenting with dizziness. PRIMARY AND SECONDARY OUTCOME MEASURES: We collected clinical data from the initial ED report from July 2015 to August 2020 and compared them with the follow-up report if available. We calculated the prevalence of vestibular syndromes and stroke prevalence in patients with dizziness. Vestibular syndromes are differentiated in acute (AVS) (eg, stroke, vestibular neuritis), episodic (EVS) (eg, benign paroxysmal positional vertigo, transient ischaemic attack) and chronic (CVS) (eg, persistent postural-perceptual dizziness) vestibular syndrome. We reported the rate of diagnostic errors using the follow-up diagnosis as the reference standard. RESULTS: We included 1535 patients with dizziness. 19.7% (303) of the patients presented with AVS, 34.7% (533) with EVS, 4.6% (71) with CVS and 40.9% (628) with no or unclassifiable vestibular syndrome. The three most frequent diagnoses were stroke/minor stroke (10.1%, 155), benign paroxysmal positional vertigo (9.8%, 150) and vestibular neuritis (9.6%, 148). Among patients with AVS, 25.4% (77) had stroke. The cause of the dizziness remained unknown in 45.0% (692) and 18.0% received a false diagnosis. There was a follow-up in 662 cases (43.1%) and 58.2% with an initially unknown diagnoses received a final diagnosis. Overall, 69.9% of all 1535 patients with dizziness received neuroimaging (MRI 58.2%, CT 11.6%) in the ED. CONCLUSIONS: One-fourth of patients with dizziness in the ED presented with AVS with a high prevalence (10%) of vestibular strokes. EVS was more frequent; however, the rate of undiagnosed patients with dizziness and the number of patients receiving neuroimaging were high. Almost half of them still remained without diagnosis and among those diagnosed were often misclassified. Many unclear cases of vertigo could be diagnostically clarified after a follow-up visit.


Assuntos
Acidente Vascular Cerebral , Neuronite Vestibular , Adulto , Humanos , Tontura/diagnóstico , Tontura/epidemiologia , Tontura/etiologia , Vertigem Posicional Paroxística Benigna , Neuronite Vestibular/complicações , Neuronite Vestibular/diagnóstico , Neuronite Vestibular/epidemiologia , Estudos Transversais , Estudos Retrospectivos , Serviço Hospitalar de Emergência , Erros de Diagnóstico , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
7.
Front Neurol ; 13: 919777, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36158956

RESUMO

Objective: Measuring the Vestibular-Ocular-Reflex (VOR) gains with the video head impulse test (vHIT) allows for accurate discrimination between peripheral and central causes of acute vestibular syndrome (AVS). In this study, we sought to investigate whether the accuracy of artificial intelligence (AI) based vestibular stroke classification applied in unprocessed vHIT data is comparable to VOR gain classification. Methods: We performed a prospective study from July 2015 until April 2020 on all patients presenting at the emergency department (ED) with signs of an AVS. The patients underwent vHIT followed by a delayed MRI, which served as a gold standard for stroke confirmation. The MRI ground truth labels were then applied to train a recurrent neural network (long short-term memory architecture) that used eye- and head velocity time series extracted from the vHIT examinations. Results: We assessed 57 AVS patients, 39 acute unilateral vestibulopathy patients (AUVP) and 18 stroke patients. The overall sensitivity, specificity and accuracy for detecting stroke with a VOR gain cut-off of 0.57 was 88.8, 92.3, and 91.2%, respectively. The trained neural network was able to classify strokes with a sensitivity of 87.7%, a specificity of 88.4%, and an accuracy of 87.9% based on the unprocessed vHIT data. The accuracy of these two methods was not significantly different (p = 0.09). Conclusion: AI can accurately diagnose a vestibular stroke by using unprocessed vHIT time series. The quantification of eye- and head movements with the use of machine learning and AI can serve in the future for an automated diagnosis in ED patients with acute dizziness. The application of different neural network architectures can potentially further improve performance and enable direct inference from raw video recordings.

8.
Front Neurol ; 13: 920357, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35903121

RESUMO

Objective: A three-step bedside test ("HINTS": Head Impulse-Nystagmus-Test of Skew), is a well-established way to differentiate peripheral from central causes in patients with acute vestibular syndrome (AVS). Nowadays, the use of videooculography gives physicians the possibility to quantify all eye movements. The goal of this study is to compare the accuracy of VOG "HINTS" (vHINTS) to an expert evaluation. Methods: We performed a prospective study from July 2015 to April 2020 on all patients presenting at the emergency department with signs of AVS. All the patients underwent clinical HINTS (cHINTS) and vHINTS followed by delayed MRI, which served as a gold standard for stroke confirmation. Results: We assessed 46 patients with AVS, 35 patients with acute unilateral vestibulopathy, and 11 patients with stroke. The overall accuracy of vHINTS in detecting a central pathology was 94.2% with 100% sensitivity and 88.9% specificity. Experts, however, assessed cHINTS with a lower accuracy of 88.3%, 90.9% sensitivity, and 85.7% specificity. The agreement between clinical and video head impulse tests was good, whereas for nystagmus direction was fair. Conclusions: vHINTS proved to be very accurate in detecting strokes in patients AVS, with 9% points better sensitivity than the expert. The evaluation of nystagmus direction was the most difficult part of HINTS.

9.
Eur Arch Otorhinolaryngol ; 279(12): 5547-5554, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35461382

RESUMO

PURPOSE: In individuals with severe hearing loss, mobile phone communication is limited despite treatment with a cochlear implant (CI). The goal of this study is to identify the best communication practice for CI users by comparing speech comprehension of conventional mobile phone (GSM) calls, Voice over Internet Protocol (VoIP) calls, and the application of a wireless phone clip (WPC) accessory. METHODS: This study included 13 individuals (mean age 47.1  ± 17.3 years) with at least one CI. Frequency response and objective voice quality were tested for each device, transmission mode and the WPC. We measured speech comprehension using a smartphone for a GSM call with and without WPC as well as VoIP-calls with and without WPC at different levels of white background noise. RESULTS: Frequency responses of the WPC were limited (< 4 kHz); however, speech comprehension in a noisy environment was significantly improved compared to GSM. Speech comprehension was improved by 9-27% utilizing VoIP or WPC compared to GSM. WPC was superior in noisy environments (80 dB SPL broadband noise) compared to GSM. At lower background noise levels (50, 60, 70 dB SPL broadband noise), VoIP resulted in improved speech comprehension with and without WPC. Speech comprehension scores did not correlate with objective voice quality measurements. CONCLUSION: Speech comprehension was best with VoIP alone; however, accessories such as a WPC provide additional improvement in the presence of background noise. Mobile phone calls utilizing VoIP technology, with or without a WPC accessory, result in superior speech comprehension compared to GSM.


Assuntos
Telefone Celular , Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Adulto , Pessoa de Meia-Idade , Fala , Compreensão , Implante Coclear/métodos , Internet
10.
J Vis Exp ; (180)2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35253796

RESUMO

The microscopic transcanal (aka transmeatal) surgical approach was first described in the 60s, offering a minimally invasive means of reaching the external auditory canal, the middle ear, and epitympanon. Such an approach avoids a retroauricular or endaural skin incision; however, working through a narrow space needs angled microsurgical instruments and specific training in otologic surgery. The transcanal approach restricts the working space; however, it offers a binocular microscopic vision into the middle ear without extended skin incisions and thus, reducing post-operative pain and bleeding. In addition, this minimally invasive approach avoids scar tissue complications, hypoesthesia of the auricle, and potential protrusion of the pinna. Despite its numerous advantages, this method is still not routinely performed by otologic surgeons. Since this minimally invasive technique is more challenging, there is a need for extensive training in order for it to be widely adopted by otologic surgeons. This article provides step-by-step surgical instructions for stapes surgery and reports possible indications, pitfalls, and limitations using this microscopic transcanal technique.


Assuntos
Procedimentos Cirúrgicos Otológicos , Cirurgia do Estribo , Orelha Média/cirurgia , Endoscopia/métodos , Microcirurgia , Procedimentos Cirúrgicos Otológicos/métodos
11.
Eur Arch Otorhinolaryngol ; 279(10): 4793-4799, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35072767

RESUMO

PURPOSE: The use of magnetic resonance imaging (MRI) is often limited in patients with auditory implants because of the presence of metallic components and magnets. The aim of this study was to evaluate the clinical usefulness of a customized MRI sequence for metal artifact suppression in patients with BONEBRIDGETM BCI 602 implants (MED-EL, Innsbruck, Austria), the successor of the BCI 601 model. METHODS: Using our in-house developed and customized metal artifact reduction sequence (SEMAC-VAT WARP), MRI artifacts were evaluated qualitatively and quantitatively. MRI sequences were performed with and without artifact reduction on two whole head specimens with and without the BCI 602 implant. In addition, the influence of two different implantation sites (mastoid versus retrosigmoid) and head orientation on artifact presence was investigated. RESULTS: Artifact volume was reduced by more than the 50%. Results were comparable with those obtained with the BCI 601, showing no significant differences in the dimensions of artifacts caused by the implant. CONCLUSION: SEMAC-VAT WARP was once more proved to be efficient at reducing metal artifacts on MR images. The dimensions of artifacts associated with the BCI 602 are not smaller than those caused by the BCI 601.


Assuntos
Artefatos , Condução Óssea , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Metais , Próteses e Implantes
12.
J Neurol ; 269(2): 853-860, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34191079

RESUMO

OBJECTIVE: Cold and warm water ear irrigation, also known as bithermal caloric testing, has been considered for over 100 years the 'Gold Standard' for the detection of peripheral vestibular hypofunction. Its discovery was awarded a Nobel Prize. We aimed to investigate the diagnostic accuracy of Caloric Testing when compared to the video head impulse test (vHIT) in differentiating between vestibular neuritis and vestibular strokes in acute dizziness. DESIGN: Prospective cross-sectional study (convenience sample). SETTING: All patients presenting with signs of an acute vestibular syndrome at the emergency department of a tertiary referral center. PARTICIPANTS: One thousand, six hundred seventy-seven patients were screened between February 2015 and May 2020 for Acute Vestibular Syndrome (AVS), of which 152 met the inclusion criteria and were enrolled. Inclusion criteria consisted of a state of continuous dizziness, associated with nausea or vomiting, head-motion intolerance, new gait or balance disturbance and nystagmus. Patients were excluded if they were younger than 18 years, if symptoms lasted < 24 h or if the index ED visit was > 72 h after symptom onset. Of the 152 included patients 85 completed testing. We assessed 58 vestibular neuritis and 27 stroke patients. MAIN OUTCOME MEASURES: All patients underwent calorics and vHIT followed by a delayed MRI which served as a gold standard for vestibular stroke confirmation. RESULTS: The overall sensitivity and specificity for detecting stroke with a caloric asymmetry cut-off of 30.9% was 75% and 86.8%, respectively [negative likelihood ratio (NLR) 0.29] compared to 91.7% and 88.7% for vHIT (NLR 0.094). Best VOR gain cut-off was 0.685. Twenty-five percent of vestibular strokes were misclassified by calorics, 8% by vHIT. CONCLUSIONS: Caloric testing proved to be less accurate than vHIT in discriminating stroke from vestibular neuritis in acute dizziness. Contrary to classic teaching, asymmetric caloric responses can also occur with vestibular strokes and might put the patient at risk for misdiagnosis. We, therefore, recommend to abandon caloric testing in current practice and to replace it with vHIT in the acute setting. Caloric testing has still its place as a diagnostic tool in an outpatient setting.


Assuntos
Tontura , Neuronite Vestibular , Testes Calóricos , Estudos Transversais , Tontura/diagnóstico , Teste do Impulso da Cabeça , Humanos , Estudos Prospectivos , Reflexo Vestíbulo-Ocular , Neuronite Vestibular/complicações , Neuronite Vestibular/diagnóstico
13.
Eur Arch Otorhinolaryngol ; 279(6): 2873-2879, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34302212

RESUMO

OBJECTIVE: The alternate cover test (ACT) in patients with acute vestibular syndrome is part of the 'HINTS' battery test. Although quantitative, the ACT is highly dependent on the examiner's experience and could theoretically vary greatly between examiners. In this study, we sought to validate an automated video-oculography (VOG) system based on eye tracking and dedicated glasses. METHODS: We artificially induced a vertical strabismus to simulate a skew deviation on ten healthy subjects, aged from 26 to 66, using different press-on Fresnel prisms on one eye while recording eye position with VOG of the contralateral eye. We then compared the system's performance to that of a blinded trained orthoptist using conventional, semi-quantitative method of skew measurement known as the alternate prism cover test (APCT) as a gold standard. RESULTS: We found a significant correlation between the reference APCT and the Skew VOG (Pearson's R2 = 0.606, p < 0.05). There was a good agreement between the two tests (intraclass correlation coefficient 0.852, 95 CI 0.728-0.917, p < 0.001). The overall accuracy of the VOG was estimated at 80.53% with an error rate of 19.46%. There was no significant difference in VOG skew estimations compared with the gold standard except for very small skews. CONCLUSIONS: VOG offers an objective and quantitative skew measurement and proved to be accurate in measuring vertical eye misalignment compared to the ACT with prisms. Precision was moderate, which mandates a sufficient number of tests per subject.


Assuntos
Estrabismo , Humanos , Estrabismo/diagnóstico , Inquéritos e Questionários , Vertigem
14.
Otol Neurotol ; 43(2): 227-235, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34816809

RESUMO

OBJECTIVE: To evaluate the audiological and subjective benefit from hearing rehabilitation with an active bone conduction implant in subjects with single-sided sensorineural deafness (SSD). STUDY DESIGN: Prospective, multicenter, single-subject repeated measures. SETTING: Tertiary referral center, five clinics in Germany and Switzerland. PATIENTS: Seventeen subjects aged 18 years and older with severe to profound unilateral sensorineural hearing loss and contralateral normal hearing were followed up for 24 months. INTERVENTION: Active bone conduction implant. MAIN OUTCOME MEASURES: Speech understanding in noise was assessed in three situations: with signal from front, deaf, or normal hearing side (with noise from front in all set-ups). Subjective benefit was evaluated using the Speech, Spatial, and Qualities of Hearing (SSQ-B) and Bern Benefit in Single-Sided Deafness (BBSS) questionnaire. RESULTS: When the signal was coming from the deaf side the mean improvement of the speech reception threshold in noise ranged from 1.5 up to 2.2 dB with the device and was statistically and clinically significant at all tested timepoints. No significant difference between the aided and unaided situation was found when signal and noise were coming from the front. With the signal from the normal hearing side no clinically significant difference, that is, greater than 1 dB between the aided and unaided situation was found. The SSQ-B and BBSS questionnaire showed an overall improvement with no significant difference between time points. CONCLUSIONS: The study demonstrates long-term efficacy and benefit of the device in adults with SSD. Patients reported substantial and persistent subjective benefit from the active bone conduction implant.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva Neurossensorial , Perda Auditiva Unilateral , Percepção da Fala , Adulto , Condução Óssea , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Unilateral/cirurgia , Humanos , Estudos Prospectivos , Resultado do Tratamento
15.
Eur J Neurol ; 28(9): 2971-2979, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34176187

RESUMO

OBJECTIVE: Gaze-evoked nystagmus (GEN) is a central sign in patients with the acute vestibular syndrome (AVS); however, discriminating between a pathological and a physiologic GEN is a challenge. Here we evaluate GEN in patients with AVS. METHODS: In this prospective cross-sectional study, we used video-oculography (VOG) to compare GEN in the light (target at 15° eccentric) in 64 healthy subjects with 47 patients seen in the emergency department (ED) who had AVS; 35 with vestibular neuritis and 12 with stroke. All patients with an initial non-diagnostic MRI received a confirmatory, delayed MRI as a reference standard in detecting stroke. RESULTS: Healthy subjects with GEN had a time constant of centripetal drift >18 s. VOG identified pathologic GEN (time constant ≤ 18 s) in 33% of patients with vestibular strokes, specificity was 100%, accuracy was 83%. Results were equivalent to examination by a clinical expert. As expected, since all patients with GEN had a SN in straight-ahead position, they showed the pattern of a Bruns' nystagmus. CONCLUSIONS: One third of patients with AVS due to central vestibular strokes had a spontaneous SN in straight-ahead gaze and a pathological GEN, producing the pattern of a Bruns' nystagmus with a shift of the null position. The localization of the side of the lesion based on the null was not consistent, presumably because the circuits underlying gaze-holding are widespread in the brainstem and cerebellum. Nevertheless, automated quantification of GEN with VOG was specific, and accurately identified patients in the ED with AVS due to strokes.


Assuntos
Nistagmo Patológico , Acidente Vascular Cerebral , Estudos Transversais , Humanos , Nistagmo Patológico/diagnóstico , Nistagmo Patológico/etiologia , Estudos Prospectivos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico por imagem , Vertigem
16.
Eur J Neurol ; 28(8): 2614-2621, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33983645

RESUMO

BACKGROUND AND PURPOSE: A peripheral spontaneous nystagmus (SN) is typically enhanced or revealed by removing fixation. Conversely, failure of fixation suppression of SN is usually a sign of a central disorder. Based on Luebke and Robinson (Vision Res 1988, vol. 28 (8), pp. 941-946), who suggested that the normal fixation mechanism is disengaged during pursuit, it is hypothesized that vertical tracking in the light would bring out or enhance a horizontal SN. METHODS: Eighteen patients with acute vestibular neuritis were studied. Eye movements were recorded using video-oculography at straight-ahead gaze with and without visual fixation, and during smooth pursuit. The slow-phase velocity and the fixation suppression indices of nystagmus (relative to SN in darkness) were compared in each condition. RESULTS: During vertical tracking, the slow-phase velocity of horizontal SN with eyes near straight-ahead gaze was significantly higher (median 2.7°/s) than under static visual fixation (median 1.2°/s). Likewise, the fixation index was significantly higher (worse suppression) during pursuit (median 48%) than during fixation (median 26%). A release of SN was also suggested during horizontal pursuit, if one assumes superposition of SN on a normal and symmetrical pursuit capability.


Assuntos
Nistagmo Patológico , Acompanhamento Ocular Uniforme , Movimentos Oculares , Fixação Ocular , Humanos
17.
Ther Umsch ; 78(4): 165-170, 2021.
Artigo em Alemão | MEDLINE | ID: mdl-33899520

RESUMO

Cough from an allergological as well as from the ENT aspect Abstract. Cough is a common problem in the allergological, but less so in the rhinological consultation. The differential diagnostic spectrum for cough is extensive and may range from rhinitis and asthma to eosinophilic esophagitis and rarer diseases. In the case of chronic cough (> 2 months), the four most frequent causes must be sought, or be excluded (upper airway cough syndrome, asthma [cough-variant-asthma], non-asthmatic eosinophilic bronchitis, gastroesophageal reflux disease). Aeroallergens such as pollen, house-dust mites or occupational substances play a major role in allergies. Nevertheless, it is not uncommon for cough to be a main symptom of an antibody deficiency or a Sicca symptom complex. The more chronic the cough, the more thoroughly an investigation is indicated - often interdisciplinary. Therapy depends on the cause of the cough. In allergic respiratory diseases, allergy-specific immunotherapy may be indicated.


Assuntos
Asma , Refluxo Gastroesofágico , Hipersensibilidade , Doença Crônica , Tosse/diagnóstico , Tosse/etiologia , Tosse/terapia , Humanos , Hipersensibilidade/diagnóstico , Hipersensibilidade/terapia
18.
Eur Arch Otorhinolaryngol ; 278(11): 4225-4233, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33788034

RESUMO

PURPOSE: Magnetic resonance imaging (MRI) is often used to visualize and diagnose soft tissues. Hearing implant (HI) recipients are likely to require at least one MRI scan during their lifetime. However, the MRI scanner can interact with the implant magnet, resulting in complications for the HI recipient. This survey, which was conducted in two phases, aimed to evaluate the safety and performance of MRI scans for individuals with a HI manufactured by MED-EL (MED-EL GmbH, Innsbruck, Austria). METHODS: A survey was developed and distributed in two phases to HEARRING clinics to obtain information about the use of MRI for recipients of MED-EL devices. Phase 1 focused on how often MRI is used in diagnostic imaging of the head region of the cochlear implant (CI) recipients. Phase 2 collected safety information about MRI scans performed on HI recipients. RESULTS: 106 of the 126 MRI scans reported in this survey were performed at a field strength of 1.5 T, on HI recipients who wore the SYNCHRONY CI or SYNCHRONY ABI. The head and spine were the most frequently imaged regions. 123 of the 126 scans were performed without any complications; two HI recipients experienced discomfort/pain. One recipient required reimplantation after an MRI was performed using a scanner that had not been approved for that implant. There was only one case that required surgical removal of the implant to reduce the imaging artefact. CONCLUSION: Individuals with either a SYNCHRONY CI or SYNCHRONY ABI from MED-EL can safely undergo a 1.5 T MRI when it is performed according to the manufacturer's safety policies and procedures.


Assuntos
Implante Coclear , Implantes Cocleares , Audição , Humanos , Imageamento por Ressonância Magnética , Imãs
19.
PLoS One ; 16(2): e0245796, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33556107

RESUMO

OBJECTIVES: To assess the feasibility of radiologic measurements and find out whether hearing outcome could be predicted based on computer tomography (CT) scan evaluation in patients with temporal bone fractures and suspected ossicular joint dislocation. METHODS: We assessed 4002 temporal bone CT scans and identified 34 patients with reported ossicular joint dislocation due to trauma. We excluded those with no proven traumatic ossicular dislocation in CT scan and patients with bilateral temporal bone fractures. We measured four parameters such as malleus-incus axis distance, malleus-incus angle at midpoints, malleus- incus axis angle and ossicular joint space. The contralateral healthy side served as its own control. Hearing outcome 1-3 months after the index visit was analyzed. We assessed diagnostic accuracy and performed a logistic regression using radiologic measurement parameters for outcome prediction of conductive hearing loss (defined as >20dB air-bone gap). RESULTS: We found excellent inter-rater agreement on the measurement of axis deviation between incus and malleus in CT scans (interclass correlation coefficient 0.81). The larger the deviation of incus and malleus axis, the higher probability of poor hearing outcome (odds ratio (OR) 2.67 per 0.1mm, p = .006). A cut-off value for the axis deviation of 0.25mm showed a sensitivity of 0.778 and a specificity of 0.94 (p < .001) for discrimination between poor and good hearing outcome in terms of conductive hearing loss. CONCLUSION: Adequate assessment of high resolution CT scans of temporal bone in which ossicular chain dislocation had occurred after trauma was feasible. Axis deviations of the incus and the malleus were strongly predictive for poor hearing outcome in terms of air conduction 1-3 months after trauma. We propose a 3-level classification system for hearing outcome prediction based on radiologic measures.


Assuntos
Ossículos da Orelha/diagnóstico por imagem , Ossículos da Orelha/lesões , Audição , Tomografia Computadorizada por Raios X , Ossículos da Orelha/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
20.
Front Neurol ; 11: 604502, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33329363

RESUMO

Objective: Alexander's law (AL) states the intensity of nystagmus increases when gaze is toward the direction of the quick phase. What might be its cause? A gaze-holding neural integrator (NI) that becomes imperfect as the result of an adaptive process, or saturation in the discharge of neurons in the vestibular nuclei? Methods: We induced nystagmus in normal subjects using a rapid chair acceleration around the yaw (vertical) axis to a constant velocity of 200°/second [s] and then, 90 s later, a sudden stop to induce post-rotatory nystagmus (PRN). Subjects alternated gaze every 2 s between flashing LEDs (right/left or up/down). We calculated the change in slow-phase velocity (ΔSPV) between right and left gaze when the lateral semicircular canals (SCC) were primarily stimulated (head upright) or, with the head tilted to the side, stimulating the vertical and lateral SCC together. Results: During PRN AL occurred for horizontal eye movements with the head upright and for both horizontal and vertical components of eye movements with the head tilted. AL was apparent within just a few seconds of the chair stopping when peak SPV of PRN was reached. When slow-phase velocity of PRN faded into the range of 6-18°/s AL could no longer be demonstrated. Conclusions: Our results support the idea that AL is produced by asymmetrical responses within the vestibular nuclei impairing the NI, and not by an adaptive response that develops over time. AL was related to the predicted plane of eye rotations in the orbit based on the pattern of SCC activation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA