Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Front Neurol ; 14: 1181539, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37621854

RESUMO

Introduction: Intracochlear electrocochleography (ECochG) is increasingly being used to measure residual inner ear function in cochlear implant (CI) recipients. ECochG signals reflect the state of the inner ear and can be measured during implantation and post-operatively. The aim of our study was to apply an objective deep learning (DL)-based algorithm to assess the reproducibility of longitudinally recorded ECochG signals, compare them with audiometric hearing thresholds, and identify signal patterns and tonotopic behavior. Methods: We used a previously published objective DL-based algorithm to evaluate post-operative intracochlear ECochG signals collected from 21 ears. The same measurement protocol was repeated three times over 3 months. Additionally, we measured the pure-tone thresholds and subjective loudness estimates for correlation with the objectively detected ECochG signals. Recordings were made on at least four electrodes at three intensity levels. We extracted the electrode positions from computed tomography (CT) scans and used this information to evaluate the tonotopic characteristics of the ECochG responses. Results: The objectively detected ECochG signals exhibited substantial repeatability over a 3-month period (bias-adjusted kappa, 0.68; accuracy 83.8%). Additionally, we observed a moderate-to-strong dependence of the ECochG thresholds on audiometric and subjective hearing levels. Using radiographically determined tonotopic measurement positions, we observed a tendency for tonotopic allocation with a large variance. Furthermore, maximum ECochG amplitudes exhibited a substantial basal shift. Regarding maximal amplitude patterns, most subjects exhibited a flat pattern with amplitudes evenly distributed over the electrode carrier. At higher stimulation frequencies, we observed a shift in the maximum amplitudes toward the basal turn of the cochlea. Conclusions: We successfully implemented an objective DL-based algorithm for evaluating post-operative intracochlear ECochG recordings. We can only evaluate and compare ECochG recordings systematically and independently from experts with an objective analysis. Our results help to identify signal patterns and create a better understanding of the inner ear function with the electrode in place. In the next step, the algorithm can be applied to intra-operative measurements.

2.
Audiol Res ; 13(3): 459-465, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37366686

RESUMO

BACKGROUND: With the advent of cochlear implants, tactile aids for the profoundly deaf became obsolete decades ago. Nevertheless, they might still be useful in rare cases. We report the case of a 25-year-old woman with Bosley-Salih-Alorainy Syndrome and bilateral cochlear aplasia. METHODS: After it was determined that cochlear or brainstem implants were not an option and tactile aids were not available anymore, a bone conduction device (BCD) on a softband was tried as a tactile aid. The usual retroauricular position and a second position close to the wrist, preferred by the patient, were compared. Sound detection thresholds were measured with and without the aid. Additionally, three bilaterally deaf adult cochlear implant users were tested under the same conditions. RESULTS: At 250-1000 Hz, sounds were perceived as vibrations above approximately 45-60 dB with the device at the wrist. Thresholds were approximately 10 dB poorer when placed retroauricularly. Differentiation between different sounds seemed difficult. Nevertheless, the patient uses the device and can perceive loud sounds. CONCLUSIONS: Cases where the use of tactile aids may make sense are probably very rare. The use of BCD, placed, e.g., at the wrist, may be useful, but sound perception is limited to low frequencies and relatively loud levels.

3.
Front Neurol ; 13: 844687, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35614919

RESUMO

Superior canal dehiscence syndrome (SCDS) is a structural bony defect of the roof of the superior semi-circular canal into the middle cranial fossa and is responsible for the creation of a third window, which alters the dynamics of the inner ear. During humming, vibratory waves entering the vestibulum and cochlea are re-routed through the dehiscence, leading to stimulation of the otolithic and ampullary vestibular organs. This is responsible for the torsional-vertical nystagmus known as "fremitus nystagmus". In this case report, we video-document a rare case of fremitus nystagmus and its resolution after plugging of the superior semi-circular canal.

4.
Front Radiol ; 2: 965474, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37492684

RESUMO

Purpose: Otospongiotic plaques can be seen on conventional computed tomography (CT) as focal lesions around the cochlea. However, the resolution remains insufficient to enable evaluation of intracochlear damage. MicroCT technology provides resolution at the single micron level, offering an exceptional amplified view of the otosclerotic cochlea. In this study, a non-decalcified otosclerotic cochlea was analyzed and reconstructed in three dimensions for the first time, using microCT technology. The pre-clinical relevance of this study is the demonstration of extensive pro-inflammatory buildup inside the cochlea which cannot be seen with conventional cone-beam CT (CBCT) investigation. Materials and Methods: A radiological and a three-dimensional (3D) anatomical study of an otosclerotic cochlea using microCT technology is presented here for the first time. 3D-segmentation of the human cochlea was performed, providing an unprecedented view of the diseased area without the need for decalcification, sectioning, or staining. Results: Using microCT at single micron resolution and geometric reconstructions, it was possible to visualize the disease's effects. These included intensive tissue remodeling and highly vascularized areas with dilated capillaries around the spongiotic foci seen on the pericochlear bone. The cochlea's architecture as a morphological correlate of the otosclerosis was also seen. With a sagittal cut of the 3D mesh, it was possible to visualize intense ossification of the cochlear apex, as well as the internal auditory canal, the modiolus, the spiral ligament, and a large cochleolith over the osseous spiral lamina. In addition, the oval and round windows showed intense fibrotic tissue formation and spongiotic bone with increased vascularization. Given the recently described importance of the osseous spiral lamina in hearing mechanics and that, clinically, one of the signs of otosclerosis is the Carhart notch observed on the audiogram, a tonotopic map using the osseous spiral lamina as region of interest is presented. An additional quantitative study of the porosity and width of the osseous spiral lamina is reported. Conclusion: In this study, structural anatomical alterations of the otosclerotic cochlea were visualized in 3D for the first time. MicroCT suggested that even though the disease may not appear to be advanced in standard clinical CT scans, intense tissue remodeling is already ongoing inside the cochlea. That knowledge will have a great impact on further treatment of patients presenting with sensorineural hearing loss.

5.
J Neurol ; 269(3): 1396-1403, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34244842

RESUMO

OBJECTIVE: Skew deviation results from a dysfunction of the graviceptive pathways in patients with an acute vestibular syndrome (AVS) leading to vertical diplopia due to vertical ocular misalignment. It is considered as a central sign, however, the prevalence of skew and the accuracy of its test is not well known . METHODS: We performed a prospective study from February 2015 until September 2020 of all patients presenting at our emergency department (ED) with signs of AVS. All patients underwent clinical HINTS and video test of skew (vTS) followed by a delayed MRI, which served as a gold standard for vestibular stroke confirmation. RESULTS: We assessed 58 healthy subjects, 53 acute unilateral vestibulopathy patients (AUVP) and 24 stroke patients. Skew deviation prevalence was 24% in AUVP and 29% in strokes. For a positive clinical test of skew, the cut-off of vertical misalignment was 3 deg with a very low sensitivity of 15% and specificity of 98.2%. The sensitivity of vTS was 29.2% with a specificity of 75.5%. CONCLUSIONS: Contrary to prior knowledge, skew deviation proved to be more prevalent in patients with AVS and occurred in every forth patient with AUVP. Large skew deviations (> 3.3 deg), were pointing toward a central lesion. Clinical and video test of skew offered little additional diagnostic value compared to other diagnostic tests such as the head impulse test and nystagmus test. Video test of skew could aid to quantify skew in the ED setting in which neurotological expertise is not always readily available.


Assuntos
Transtornos da Motilidade Ocular , Vertigem , Teste do Impulso da Cabeça , Humanos , Náusea , Estudos Prospectivos , Vertigem/diagnóstico
6.
Oral Health Prev Dent ; 19(1): 287-294, 2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-34057338

RESUMO

PURPOSE: To analyse the taste function in a pool of untreated patients with oral lichen planus (OLP) with tongue lesions (n = 35) and without tongue lesions (n = 36) and to compare it to healthy subjects (n = 36). MATERIALS AND METHODS: Firstly, the subjective overall taste ability and impairment of the sensations of 'sweet', 'sour', 'salty' and 'bitter' were recorded in all three groups. Secondly, taste function was tested in all included subjects using the standardised 'Taste Strips' test. RESULTS: Data showed a statistically statistically significant difference in overall taste perception between OLP patients with tongue lesions and control subjects (p = 0.027) for the tested taste function. The sensation of 'sour' showed the most pronounced difference (p = 0.08). The subjective taste perception and that of individual taste qualities did not differ statistically significantly between the three groups, and the correlation between subjective and objective taste perception was low. There was also a low correlation between taste scores and the presence of lesions on different areas of the tongue. CONCLUSION: For patients with OLP experiencing a loss in appetite, a formal taste examination and subsequent counselling should be considered.


Assuntos
Líquen Plano , Percepção Gustatória , Humanos , Paladar , Limiar Gustativo , Língua
7.
Neurology ; 97(1): e42-e51, 2021 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-33986142

RESUMO

OBJECTIVE: Failure of fixation suppression of spontaneous nystagmus is sometimes seen in patients with vestibular strokes involving the cerebellum or brainstem; however, the accuracy of this test for the discrimination between peripheral and central causes in patients with an acute vestibular syndrome (AVS) is unknown. METHODS: Patients with AVS were screened and recruited (convenience sample) as part of a prospective cross-sectional study in the emergency department between 2015 and 2020. All patients received neuroimaging, which served as a reference standard. We recorded fixation suppression with video-oculography (VOG) for forward, right, and left gaze. The ocular fixation index (OFI) and the spontaneous nystagmus slow velocity reduction was calculated. RESULTS: We screened 1,646 patients reporting dizziness in the emergency department and tested for spontaneous nystagmus in 148 patients with AVS. We analyzed 56 patients with a diagnosed acute unilateral vestibulopathy (vestibular neuritis) and 28 patients with a confirmed stroke. There was a complete nystagmus fixation suppression in 49.5% of patients with AVS, in 40% of patients with vestibular neuritis, and in 62.5% of patients with vestibular strokes. OFI scores had no predictive value for detecting strokes; however, a nystagmus reduction of less than 2 °/s showed a high accuracy of 76.9% (confidence interval 0.59-0.89) with a sensitivity of 62.2% and specificity of 84.8% in detecting strokes. CONCLUSIONS: The presence of fixation suppression does not rule out a central lesion. The magnitude of suppression was lower compared to patients with vestibular neuritis. The nystagmus suppression test predicts vestibular strokes accurately provided that eye movements are recorded with VOG. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that in patients with an AVS, decreased fixation suppression recorded with VOG occurred more often in stroke (76.9%) than in vestibular neuritis (37.8%).


Assuntos
Tontura/fisiopatologia , Nistagmo Patológico/fisiopatologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Tontura/diagnóstico por imagem , Feminino , Fixação Ocular , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Nistagmo Patológico/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/diagnóstico por imagem , Doenças Vestibulares/fisiopatologia , Neuronite Vestibular/fisiopatologia , Adulto Jovem
8.
Ear Hear ; 41(6): 1747-1751, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33136647

RESUMO

OBJECTIVES: Clinicians performing a horizontal head impulse test (HIT) are looking for a corrective saccade. The detection of such saccades is a challenge. The aim of this study is to assess an expert's likelihood of detecting corrective saccades in subjects with vestibular hypofunction. DESIGN: In a prospective cohort observational study at a tertiary referral hospital, we assessed 365 horizontal HITs performed clinically by an expert neurootologist from a convenience sample of seven patients with unilateral or bilateral deficient vestibulo-ocular reflex (VOR). All HITs were recorded simultaneously by video-oculography, as a gold standard. We evaluated saccades latency and amplitude, head velocity, and gain. RESULTS: Saccade amplitude was statistically the most significant parameter for saccade detection (p < 0.001).The probability of saccade detection was eight times higher for HIT toward the pathological side (p = 0.029). In addition, an increase in saccade amplitude resulted in an increased probability of detection (odds ratio [OR] 1.77 [1.31 to 2.40] per degree, p < 0.001). The sensitivity to detect a saccade amplitude of 1 degree was 92.9% and specificity 79%. Saccade latency and VOR gain did not significantly influence the probability of the physician identifying a saccade (OR 1.02 [0.94 to 1.11] per 10-msec latency and OR 0.84 [0.60 to 1.17] per 0.1 VOR gain increase). CONCLUSIONS: The saccade amplitude is the most important factor for accurate saccade detection in clinically performed head impulse tests. Contrary to current knowledge, saccade latency and VOR gain play a minor role in saccade detection.


Assuntos
Teste do Impulso da Cabeça , Reflexo Vestíbulo-Ocular , Humanos , Estudos Prospectivos , Movimentos Sacádicos , Centros de Atenção Terciária
9.
J Psychosom Res ; 135: 110155, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32534321

RESUMO

OBJECTIVE: The study aimed at investigating the sensitivity to noise and chemosensory environmental stressors as well as the relation to perceived stress, depression and anxiety in subjects with chronic tinnitus as compared to subjects without tinnitus. METHODS: We included 75 subjects with chronic tinnitus and 75 age and sex-matched subjects without tinnitus. Standardized questionnaires assessing the level of distress and impairment of quality of life caused by tinnitus, perceived level of stress, anxiety and depression, environmental noise and chemosensory sensitivity were used. A subgroup of 27 subjects with chronic tinnitus and 20 age-matched subjects without tinnitus underwent testing of olfactory function with the Sniffin' Sticks test and testing of intranasal trigeminal function using CO2 thresholds. RESULTS: Our data confirmed the increased environmental noise sensitivity (NSS) in patients with tinnitus. Furthermore, we observed an increased environmental chemosensory sensitivity (CSS), but no difference in measured chemosensory function. Subjects with tinnitus showed also significant higher levels of perceived stress, anxiety and depression and those symptoms partially correlated to CSS and NSS. Predictors of both NSS and CSS results were the presence / absence of tinnitus and high anxiety levels while neither stress nor depression were found as predicting variables. CONCLUSIONS: The results suggest that chronic tinnitus is related to a multisensory environmental hypersensitivity. Anxiety seems to be a predictor of this environmental vulnerability.


Assuntos
Sensação , Zumbido/psicologia , Adulto , Ansiedade/complicações , Doença Crônica/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Olfato , Inquéritos e Questionários , Zumbido/complicações , Zumbido/fisiopatologia , Nervo Trigêmeo/fisiopatologia , Adulto Jovem
10.
Front Neurol ; 11: 615651, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33551973

RESUMO

Objective: The video head impulse test (vHIT) is nowadays a fast and objective method to measure vestibular function. However, its usability is controversial and often considered as a test performed by experts only. We sought to study the learning curve of novices and to document all possible mistakes and pitfalls in the process of learning. Methods: In a prospective cohort observational study, we included 10 novices. We tested their ability to perform correctly horizontal head impulses recorded with vHIT. We assessed vHITs in 10 sessions with 20 impulses per session giving a video instruction after the first session (S1) and individual feedback from an expert for session 2 (S2) up to session 10 (S10). We compared VOR gain, the HIT acceptance rate by the device algorithm, mean head velocity, acceleration, excursion, and overshoot between sessions. Results: A satisfying number of accepted HITs (80%) was reached after an experience of 160 vHITs. Mean head velocity between sessions was always in accepted limits. Head acceleration was too low at the beginning (S1) but improved significantly after the video instruction (p = 0.001). Mean head excursion and overshoot showed a significant improvement after 200 head impulses (p < 0.001 each). Conclusions: We showed that novices can learn to perform head impulses invHIT very fast provided that they receive instructions and feedback from an experienced examiner. Video instructions alone were not sufficient. The most common pitfall was a low head acceleration.

11.
Clin Oral Investig ; 21(3): 957-964, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27270904

RESUMO

OBJECTIVES: The aim of the study was to evaluate if patients with oral lichen planus (OLP) and tongue involvement have impaired taste function and if there is an association to the perception of pain. MATERIAL AND METHODS: The test group included patients with OLP and involvement of the tongue without treatment (n = 20). Control subjects had no mucosal or systemic disease affecting taste function and were matched for age and gender (n = 20). Patients' intraoral pain and subjective perception of taste were recorded on a visual analog scale. Taste function was assessed by means of the "taste strips." RESULTS: Measured taste function was slightly but significantly decreased in OLP patients compared to control subjects (p = 0.01). Self-rated taste perception did not differ in both groups (p = 0.8). Post hoc analysis showed that particularly the taste quality "sour" was most affected by the OLP status (p = 0.01). There were no correlations between pain and subjective/objective taste perception. CONCLUSION: Untreated OLP subjects have lower gustatory function, which they are not aware of. CLINICAL RELEVANCE: Impaired gustatory function in patients with OLP may affect patient's quality of life. Further studies on larger samples sizes are requested.


Assuntos
Líquen Plano Bucal/fisiopatologia , Percepção Gustatória/fisiologia , Língua/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos , Qualidade de Vida
12.
Ther Umsch ; 73(4): 189-96, 2016.
Artigo em Alemão | MEDLINE | ID: mdl-27132639

RESUMO

Chronic rhinosinusitis is a common complex medical condition associated with high therapy costs and quality of life impairment. The European Position Paper on Rhinosinusitis and Nasal Polyps (EPOS) 2012 delineates the current standard of management of the patient with chronic rhinosinusitis for both defined disease forms: with and without polyps. Medical history and endoscopic or CT findings are needed for the correct diagnosis. Therapy of chronic rhinosinusitis aims at achieving a local disease control and reducing patients' symptoms. The center point of conservative therapy of both forms is the topical application of steroids together with nasal saline irrigations. In case of persistence of symptoms or in severe chronic rhinosinusitis with polyps, different local application methods of steroids or short systemic steroid cures should be considered. In case of insufficient disease control with conservative treatment, functional endoscopic sinus surgery is the accepted as "gold standard". Purpose of the surgical management is opening of the sinus ostia in order to improve sinus ventilation and mucociliary clearance as well as to facilitate a wide distribution of topical drugs. Due to technical advances, endoscopic sinus has been reported to be a safe and effective procedure.


Assuntos
Endoscopia/normas , Procedimentos Cirúrgicos Nasais/normas , Rinite/diagnóstico , Rinite/terapia , Sinusite/diagnóstico , Sinusite/terapia , Doença Crônica , Humanos , Anamnese/normas , Guias de Prática Clínica como Assunto , Esteroides/uso terapêutico , Irrigação Terapêutica/normas , Tomografia Computadorizada por Raios X/normas
13.
Cancers (Basel) ; 7(2): 585-97, 2015 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-25836654

RESUMO

High-throughput molecular profiling approaches have emerged as precious research tools in the field of head and neck translational oncology. Such approaches have identified and/or confirmed the role of several genes or pathways in the acquisition/maintenance of an invasive phenotype and the execution of cellular programs related to cell invasion. Recently published new-generation sequencing studies in head and neck squamous cell carcinoma (HNSCC) have unveiled prominent roles in carcinogenesis and cell invasion of mutations involving NOTCH1 and PI3K-patwhay components. Gene-expression profiling studies combined with systems biology approaches have allowed identifying and gaining further mechanistic understanding into pathways commonly enriched in invasive HNSCC. These pathways include antigen-presenting and leucocyte adhesion molecules, as well as genes involved in cell-extracellular matrix interactions. Here we review the major insights into invasiveness in head and neck cancer provided by high-throughput molecular profiling approaches.

14.
Otol Neurotol ; 35(3): 545-54, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24492132

RESUMO

HYPOTHESIS: Facial nerve monitoring can be used synchronous with a high-precision robotic tool as a functional warning to prevent of a collision of the drill bit with the facial nerve during direct cochlear access (DCA). BACKGROUND: Minimally invasive direct cochlear access (DCA) aims to eliminate the need for a mastoidectomy by drilling a small tunnel through the facial recess to the cochlea with the aid of stereotactic tool guidance. Because the procedure is performed in a blind manner, structures such as the facial nerve are at risk. Neuromonitoring is a commonly used tool to help surgeons identify the facial nerve (FN) during routine surgical procedures in the mastoid. Recently, neuromonitoring technology was integrated into a commercially available drill system enabling real-time monitoring of the FN. The objective of this study was to determine if this drilling system could be used to warn of an impending collision with the FN during robot-assisted DCA. MATERIALS AND METHODS: The sheep was chosen as a suitable model for this study because of its similarity to the human ear anatomy. The same surgical workflow applicable to human patients was performed in the animal model. Bone screws, serving as reference fiducials, were placed in the skull near the ear canal. The sheep head was imaged using a computed tomographic scanner and segmentation of FN, mastoid, and other relevant structures as well as planning of drilling trajectories was carried out using a dedicated software tool. During the actual procedure, a surgical drill system was connected to a nerve monitor and guided by a custom built robot system. As the planned trajectories were drilled, stimulation and EMG response signals were recorded. A postoperative analysis was achieved after each surgery to determine the actual drilled positions. RESULTS: Using the calibrated pose synchronized with the EMG signals, the precise relationship between distance to FN and EMG with 3 different stimulation intensities could be determined for 11 different tunnels drilled in 3 different subjects. CONCLUSION: From the results, it was determined that the current implementation of the neuromonitoring system lacks sensitivity and repeatability necessary to be used as a warning device in robotic DCA. We hypothesize that this is primarily because of the stimulation pattern achieved using a noninsulated drill as a stimulating probe. Further work is necessary to determine whether specific changes to the design can improve the sensitivity and specificity.


Assuntos
Cóclea/cirurgia , Implante Coclear/métodos , Eletromiografia , Nervo Facial/fisiologia , Robótica , Animais , Modelos Animais , Ovinos , Cirurgia Assistida por Computador/métodos
15.
Arthritis Care Res (Hoboken) ; 65(11): 1862-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23740889

RESUMO

OBJECTIVE: To prospectively evaluate histopathologic, blood cellular, serologic, and clinical changes in response to abatacept treatment in patients with primary Sjögren's syndrome (SS). METHODS: Blood, saliva, and minor salivary gland biopsy samples were obtained before and after the last of 8 doses of abatacept in 11 primary SS patients. The histologic data evaluated the numbers of lymphocytic foci and B and T cell subtypes (CD20+, CD3+, CD4+, and CD8+). The numbers of FoxP3+ regulatory T cells were measured and the FoxP3:CD3 ratio was calculated. Histologic data were compared with results from peripheral blood and with changes in saliva secretion. RESULTS: The numbers of lymphocytic foci decreased significantly (P = 0.041). Numbers of local FoxP3+ T cells decreased significantly in percentage of total lymphocytic infiltrates (P = 0.037). In the peripheral blood, B cells increased (P = 0.038). This was due to an expansion of the naive B cell pool (P = 0.034). When adjusting for disease duration, an increase was also noted for total lymphocytes (P = 0.044) and for CD4 cells (P = 0.009). Gamma globulins decreased significantly(P = 0.005), but IgG reduction did not reach significance. Adjusted for disease duration, saliva production increased significantly (P = 0.029). CONCLUSION: CTLA-4Ig treatment significantly reduces glandular inflammation in primary SS, induces several cellular changes, and increases saliva production. Remarkably, this increase in saliva production is significantly influenced by disease duration.


Assuntos
Imunidade Celular , Imunoconjugados/administração & dosagem , Glândulas Salivares/patologia , Síndrome de Sjogren/tratamento farmacológico , Abatacepte , Adulto , Idoso , Linfócitos B/imunologia , Biópsia , Relação Dose-Resposta a Droga , Feminino , Humanos , Imuno-Histoquímica , Imunossupressores/administração & dosagem , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Estudos Prospectivos , Saliva/metabolismo , Glândulas Salivares/metabolismo , Síndrome de Sjogren/imunologia , Síndrome de Sjogren/patologia , Linfócitos T/imunologia , Fator de Necrose Tumoral alfa/antagonistas & inibidores
16.
IEEE Trans Biomed Eng ; 60(4): 960-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23340586

RESUMO

Image-guided microsurgery requires accuracies an order of magnitude higher than today's navigation systems provide. A critical step toward the achievement of such low-error requirements is a highly accurate and verified patient-to-image registration. With the aim of reducing target registration error to a level that would facilitate the use of image-guided robotic microsurgery on the rigid anatomy of the head, we have developed a semiautomatic fiducial detection technique. Automatic force-controlled localization of fiducials on the patient is achieved through the implementation of a robotic-controlled tactile search within the head of a standard surgical screw. Precise detection of the corresponding fiducials in the image data is realized using an automated model-based matching algorithm on high-resolution, isometric cone beam CT images. Verification of the registration technique on phantoms demonstrated that through the elimination of user variability, clinically relevant target registration errors of approximately 0.1 mm could be achieved.


Assuntos
Cabeça/anatomia & histologia , Cabeça/cirurgia , Processamento de Imagem Assistida por Computador/métodos , Microcirurgia/métodos , Robótica/instrumentação , Cirurgia Assistida por Computador/métodos , Algoritmos , Tomografia Computadorizada de Feixe Cônico , Marcadores Fiduciais , Humanos , Microcirurgia/instrumentação , Imagens de Fantasmas , Osso Temporal/cirurgia
17.
Emerg Med J ; 30(7): 559-64, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22833594

RESUMO

OBJECTIVE: Foreign body ingestion is common and potentially lethal. This study evaluates the use of low-dose Statscans (LODOX) in emergency departments. DESIGN: This comparative cross-sectional study retrospectively assessed 28289 digital chest x-rays and 2301 LODOX scans performed between 2006 and 2010 at a tertiary emergency centre. The radiographic appearance, image quality and location of ingested foreign bodies were evaluated in standard digital chest and LODOX radiography. The mean irradiation (µSv) and cumulative mean radiation dose per patient with the ingested foreign body were calculated according to literature-based data, together with the sensitivity and specificity for each modality. RESULTS: A total of 62 foreign bodies were detected in 39 patients, of whom 19 were investigated with LODOX and 20 with conventional digital chest radiography. Thirty-three foreign bodies were located in the two upper abdominal quadrants, 21 in the lower quadrants-which are not visible on conventional digital chest radiography-seven in the oesophagus and one in the bronchial system. The sensitivity and specificity of digital chest radiography were 44.4% and 94.1%, respectively, and for the LODOX Statscan 90% and 100%, respectively. The calculated mean radiation dose for LODOX investigations was 184 µS, compared with 524 µS for digital chest radiography. CONCLUSIONS: LODOX Statscan is superior to digital chest radiography in the diagnostic work-up of ingested foreign bodies because it makes it possible to enlarge the field of view to the entire body, has higher sensitivity and specificity, and reduces the radiation dose by 65%.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Imagem Corporal Total/normas , Adolescente , Adulto , Idoso , Estudos Transversais , Deglutição , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Intensificação de Imagem Radiográfica/normas , Radiografia Torácica/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Centros de Traumatologia , Adulto Jovem
18.
Otol Neurotol ; 33(8): 1380-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22931868

RESUMO

BACKGROUND: Severe Ménière's disease (MD) may be debilitating and compromising, despite intensive medical treatment. Vestibular neurectomy (VN) is considered an effective surgical treatment for disabling MD. Our aim was to analyse the medium- to long-term outcome after retrosigmoid VN with special regard to vertigo, quality of life (American Academy of Otolaryngology-Head and Neck Surgery criteria), and pure tone average (PTA). METHODS: Retrospective evaluation of patients with disabling MD treated with retrosigmoid VN at the university hospital of Bern (1992-2009), after unsuccessful attempts at medical treatment. Demographics, clinical signs and symptoms, quality of life, thresholds of hearing, and adverse events were documented at baseline, 1 week, 12 months, and 24 months after surgery. RESULTS: Medium to long-term follow-up data were available from 44 of 78 patients, who had undergone retrosigmoid VN (19 men; mean age, 50.3 ± 11.0 yr). Vertigo disappeared in 34 (77.3%) of 44 patients and improved in 6 (13.6%) of 44 patients. Quality of life significantly improved postoperatively (mean American Academy of Otolaryngology-Head and Neck Surgery, 0.68 ± 1.14 [1 yr] and 0.57 ± 1.19 [2 yr] versus 5.11 ± 0.66). Mean PTA decreased (52.3 ± 19.2 dB versus 56.2 ± 21.6 dB [1 wk] and 60.4 ± 20.5 dB [1 yr]; p < 0.001). Ten (22.7%) of 44 patients showed improved PTA after VN. These patients had significantly higher baseline PTA (69.4 dB versus 47.9 dB; p = 0.001). CONCLUSION: Retrosigmoid VN is a valuable and safe surgical option to treat disabling MD that has proved resistant to medical treatments. It may also be indicated for patients with preoperative severely impaired thresholds of hearing, in whom a certain hearing gain may be observed.


Assuntos
Doença de Meniere/psicologia , Doença de Meniere/cirurgia , Procedimentos Neurocirúrgicos/métodos , Procedimentos Cirúrgicos Otológicos/métodos , Qualidade de Vida , Nervo Vestibular/cirurgia , Adulto , Idoso , Audiometria de Tons Puros , Avaliação da Deficiência , Tontura/etiologia , Tontura/cirurgia , Eletronistagmografia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Feminino , Perda Auditiva Neurossensorial/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/efeitos adversos , Procedimentos Cirúrgicos Otológicos/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Zumbido/etiologia , Zumbido/cirurgia , Resultado do Tratamento , Vertigem/etiologia , Vertigem/cirurgia , Testes de Função Vestibular
19.
Adv Otorhinolaryngol ; 71: 47-55, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21389704

RESUMO

INTRODUCTION: This review covers the surgery for the bone-anchored hearing aid (Baha(®)). PREOPERATIVE WORKUP: A review of the indications and preoperative diagnostics shows that best results are generally obtained in patients with conductive or mixed hearing loss rehabilitation when surgery is not applicable or has failed and in patients that suffer from single-sided deafness. An audiogram must confirm that the bone conduction hearing is within the inclusion criteria. A computed tomography scan is performed in cases of malformation to assure sufficient bone thickness at the site of screw implantation. PROCEDURE: The steps of the Baha implantation are described step by step including the setting and anesthesia, skin work with regard to different techniques, correct resection of subcutaneous tissue, preparation of the implant site, drilling and placement of the fixture and wound closure. POSTOPERATIVE CARE: After wound healing (6-8 weeks), the bone conduction aid is fitted on the abutment. Regular cleaning of the fixture is important to avoid irritations and infections. CONCLUSION: If performed carefully, the surgery for the Baha has a favorable outcome, regardless of the technique used.


Assuntos
Auxiliares de Audição , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Implantação de Prótese/métodos , Anestesia/métodos , Audiometria , Parafusos Ósseos , Correção de Deficiência Auditiva , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Humanos , Osseointegração/fisiologia , Retalhos Cirúrgicos , Titânio , Tomografia Computadorizada por Raios X
20.
Adv Otorhinolaryngol ; 71: 73-83, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21389707

RESUMO

The level of improvement in the audiological results of Baha(®) users mainly depends on the patient's preoperative hearing thresholds and the type of Baha sound processor used. This investigation shows correlations between the preoperative hearing threshold and postoperative aided thresholds and audiological results in speech understanding in quiet of 84 Baha users with unilateral conductive hearing loss, bilateral conductive hearing loss and bilateral mixed hearing loss. Secondly, speech understanding in noise of 26 Baha users with different Baha sound processors (Compact, Divino, and BP100) is investigated. Linear regression between aided sound field thresholds and bone conduction (BC) thresholds of the better ear shows highest correlation coefficients and the steepest slope. Differences between better BC thresholds and aided sound field thresholds are smallest for mid-frequencies (1 and 2 kHz) and become larger at 0.5 and 4 kHz. For Baha users, the gain in speech recognition in quiet can be expected to lie in the order of magnitude of the gain in their hearing threshold. Compared to its predecessor sound processors Baha(®) Compact and Baha(®) Divino, Baha(®) BP100 improves speech understanding in noise significantly by +0.9 to +4.6 dB signal-to-noise ratio, depending on the setting and the use of directional microphone. For Baha users with unilateral and bilateral conductive hearing loss and bilateral mixed hearing loss, audiological results in aided sound field thresholds can be estimated with the better BC hearing threshold. The benefit in speech understanding in quiet can be expected to be similar to the gain in their sound field hearing threshold. The most recent technology of Baha sound processor improves speech understanding in noise by an order of magnitude that is well perceived by users and which can be very useful in everyday life.


Assuntos
Audiometria , Limiar Auditivo/fisiologia , Auxiliares de Audição , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Adulto , Correção de Deficiência Auditiva , Feminino , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Humanos , Modelos Lineares , Masculino , Estudos Retrospectivos , Percepção da Fala/fisiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...