Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Folia Parasitol (Praha) ; 712024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38526232

RESUMO

Chagas disease (CD) is a neglected disease caused by Trypanosoma cruzi Chagas, 1909. Causative treatment can be achieved with two drugs: benznidazole or Nifurtimox. There are some gaps that hinder progress in eradicating the disease. There is no test that can efficiently assess cure control after treatment. Currently, the decline in anti-T. cruzi antibody titres is assessed with conventional serological tests, which can take years. However, the search for new markers of cure must continue to fill this gap. The present study aimed to evaluate the decline in serological titres using chimeric proteins after treatment with benznidazole in chronic patients diagnosed with CD. It was a prospective cross-sectional cohort study between 2000 and 2004 of T. cruzi-positive participants from the Añatuya region (Argentina) treated with benznidazole. Serum samples from ten patients were collected before treatment (day zero) and after the end of treatment (2, 3, 6, 12, 24 and 36 months). For the detection of anti-T. cruzi antibodies, an indirect ELISA was performed using two chimeric recombinant proteins (IBMP-8.1 and IBMP-8.4) as antigens. The changes in reactivity index within the groups before and after treatment were evaluated using the Friedman test. All participants experienced a decrease in serological titres after treatment with benznidazole, especially IBMP-8.1. However, due to the small number of samples and the short follow-up period, it is premature to conclude that this molecule serves as a criterion for sustained cure. Further studies are needed to validate tests based on these or other biomarkers to demonstrate parasitological cure.


Assuntos
Doença de Chagas , Nitroimidazóis , Trypanosoma cruzi , Humanos , Estudos Transversais , Estudos Prospectivos , Doença de Chagas/tratamento farmacológico , Proteínas Recombinantes de Fusão/uso terapêutico
2.
Am J Trop Med Hyg ; 110(4): 669-676, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38412539

RESUMO

Chagas disease (CD) is caused by the protozoan Trypanosoma cruzi, which leads to a spectrum of clinical presentations that range from asymptomatic to severe cardiac involvement. The host immune response plays a pivotal role in disease progression. Ig isotypes may contribute to disease pathogenesis. Investigating these components can provide insights into the immunopathogenic mechanisms underlying CD. This cross-sectional study aims to establish a correlation between the Ig profile of individuals infected with T. cruzi with the clinical forms of chronic CD. Serum samples were collected from partner institutions in different states of Brazil. Individuals diagnosed with chronic CD were categorized based on the clinical form of the disease. The indirect ELISA method using the recombinant chimeric Molecular Biology Institute of Paraná membrane protein 8.4 as the antigen was used to determine the Ig profile, including total IgG, IgG1, IgG2, IgG3, and IgG4. Ninety-seven serum samples from patients classified as negative (NEG, n = 38), indeterminate (IND, n = 24), mild cardiac (MC, n = 20), and severe cardiac (SC, n = 15) forms were analyzed. IgG1 exhibited greater levels compared with the other isotypes, showing a significant difference between the MC and IND groups. IgG3 levels were greater in individuals from the MC group compared with the SC group. IgG1 and IgG3 isotypes can serve as biomarkers to evaluate the progression of CD because they exhibit variations across clinical groups. Additional longitudinal studies are necessary to explore the relationship between antibody kinetics and the development of tissue damage.


Assuntos
Doença de Chagas , Trypanosoma cruzi , Humanos , Trypanosoma cruzi/genética , Proteínas Recombinantes de Fusão , Estudos Transversais , Antígenos de Protozoários , Doença de Chagas/diagnóstico , Imunoglobulina G , Anticorpos Antiprotozoários
3.
Diagnostics (Basel) ; 13(22)2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37998606

RESUMO

This study focuses on developing accurate immunoassays for diagnosing Chagas disease (CD), a challenging task due to antigenic similarities between Trypanosoma cruzi and other parasites, leading to cross-reactivity. To address this challenge, chimeric recombinant T. cruzi antigens (IBMP-8.1, IBMP-8.2, IBMP-8.3, and IBMP-8.4) were synthesized to enhance specificity and reduce cross-reactivity in tests. While these antigens showed minimal cross-reactivity with leishmaniasis, their performance with other trypanosomatid infections was unclear. This study aimed to assess the diagnostic potential of these IBMP antigens for detecting CD in patients with Crithidia sp. LVH-60A, a parasite linked to visceral leishmaniasis-like symptoms in Brazil. This study involved seven Crithidia sp. LVH-60A patients and three Leishmania infantum patients. The results indicated that these IBMP antigens displayed 100% sensitivity, with specificity ranging from 87.5% to 100%, and accuracy values between 90% and 100%. No cross-reactivity was observed with Crithidia sp. LVH-60A, and only one L. infantum-positive sample showed limited cross-reactivity with IBMP-8.1. This study suggests that IBMP antigens offer promising diagnostic performance, with minimal cross-reactivity in regions where T. cruzi and other trypanosomatids are prevalent. However, further research with a larger number of Crithidia sp. LVH-60A-positive samples is needed to comprehensively evaluate antigen cross-reactivity.

4.
Pathogens ; 12(10)2023 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-37887738

RESUMO

Chagas disease (CD), caused by the parasite Trypanosoma cruzi, is a neglected tropical disease with life-threatening implications. In this study, we conducted a seroepidemiological survey to determine the prevalence and clinical profiles of CD in 217 individuals from an impoverished rural community in Southern Bahia, Brazil. The overall prevalence of CD in the studied community was 0.92%, detected through latent class analysis (LCA). Two individuals tested positive for anti-T. cruzi IgG, both being male farmers. One case was a 22-year-old man born in Camamu, with no evidence of congenital transmission, suggesting other routes of transmission such as vector-borne transmission due to migratory activities. The other case was a 69-year-old man born in São Felipe, who had lived in an adobe/brick house and had a pacemaker due to cardiac involvement caused by CD. The prevalence in this community was lower than expected, given the socioeconomic conditions and environmental factors that contribute to T. cruzi transmission. This could be attributed to the implementation of preventive measures and vector control programs by the Brazilian Government. However, continuous monitoring and surveillance are essential to sustain control efforts and detect any potential re-emergence of the disease. While the overall prevalence was low, the detection of positive cases underscores the need for continued surveillance and control measures in vulnerable populations, such as rural communities. Active surveillance, early diagnosis, and timely treatment are crucial in preventing disease progression and complications, thereby enhancing the effectiveness of screening and treatment programs.

5.
PLoS Negl Trop Dis ; 16(11): e0010944, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36441769

RESUMO

BACKGROUND: Chagas disease (CD) is caused by Trypanosoma cruzi. The chronic phase of CD is characterized by the presence of IgG anti-T. cruzi antibodies; and diagnosis is performed by serological methods. Because there is no reliable test that can be used as a reference test, WHO recommends the parallel use of two different tests for CD serodiagnosis. If results are inconclusive, samples should be subjected to a confirmatory test, e.g., Western blot (WB) or PCR. PCR offers low sensitivity in the chronic phase, whereas few confirmatory tests based on the WB method are commercially available worldwide. Therefore, new diagnostic tools should be evaluated to fill the gap in CD confirmatory tests. In recent years, four chimeric recombinant antigens (IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4) have been evaluated in phase I, II and III studies using ELISA, liquid microarray and immunochromatography with 95-100% accuracy. Given the high diagnostic performance of these antigens, the present study investigated the ability of these molecules to diagnose chronic CD using a WB testing platform. METHODOLOGY/PRINCIPAL FINDINGS: In this study, we analyzed the diagnostic potential of four chimeric antigens using 40 T. cruzi-positive, 24-negative, and three additional positive samples for visceral leishmaniasis (i.e., potentially cross-reactive) using WB as the diagnostic platform. Checkerboard titration with different dilutions of antigens, conjugated antigens, and serum samples was performed to standardize all assays. All IBMP antigens achieved 100% sensitivity, specificity, and accuracy, with the exception of IBMP-8.3, which had 100% specificity despite lack of significance, but lower sensitivity (95%) and accuracy (96.9%). No cross-reactivity was observed in samples positive for leishmaniasis. CONCLUSIONS/SIGNIFICANCE: The present phase I (proof-of-concept) study demonstrated the high diagnostic potential of these four IBMP antigens to discriminate between T. cruzi-positive and -negative samples, making them candidates for phase II and confirmatory testing with WB.


Assuntos
Doença de Chagas , Trypanosoma cruzi , Humanos , Trypanosoma cruzi/genética , Estudo de Prova de Conceito , Doença de Chagas/diagnóstico , Western Blotting , Proteínas Recombinantes/genética
6.
Front Med (Lausanne) ; 9: 852864, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35330587

RESUMO

Chagas disease (CD) is among the top 10 causes of inability to blood donation. Blood donation centers screen for anti-Trypanosoma cruzi antibodies using highly sensitive immunoenzymatic (ELISA) or chemiluminescent methods, which can lead to false positive results. Since positive samples cannot be used, to avoid the loss of valuable blood donations, it is necessary to improve specificity without reducing the sensitivity of the tests used for blood screening. For this purpose, our group has developed four chimeric proteins (IBMP-8.1, IBMP-8.2, IBMP-8.3, and IBMP-8.4) that have been evaluated in phase I and II studies with high performance and low cross-reactivity rates. The study included a panel of 5,014 serum samples collected from volunteer blood donors at the Hematology and Hemotherapy Foundation of the State of Bahia (Brazil). They were subjected to the detection of anti-T. cruzi antibodies, using all four IBMP antigens individually and latent class analysis (LCA) as a reference test, since there is no gold standard test for this purpose. Considering the sample size analyzed, LCA classified 4,993 (99.6%) samples as T. cruzi-negative and 21 (0.42%) as T. cruzi-positive. Sensitivity values ranged from 85.71% for IBMP-8.1 and 90.48% for IBMP-8.2-95.24% for IBMP-8.3 and 100% for IBMP-8.4, while specificity ranged from 99.98% for IBMP-8.3 and IBMP-8.4-100% for IBMP-8.1 and IBMP-8.2. Accuracy values ranged from 99.4 to 99.98%. The pretest probability for the molecules was 0.42, whereas the positive posttest probability ranged from 95.24 to 99.95% and the negative posttest probability ranged from 0.00001 to 0.0006% for all antigens. The higher odds ratio diagnosis was found for IBMP-8.4, which has been shown to be a safe single antigen for serological screening of CD in blood samples. The use of chimeric IBMP antigens is an alternative to reduce the number of bags discarded due to false-positive results. These molecules have high diagnostic performance and were shown to be suitable for use in screening CD in blood banks, isolated (IBMP-8.4) or in combination; and their use in blood banks could significantly reduce unnecessary disposal of blood bags or the risk of T. cruzi transmission.

7.
PLoS Negl Trop Dis ; 16(3): e0010290, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35275913

RESUMO

BACKGROUND: Enzyme-linked immunosorbent assays (ELISA) are generally the chosen test for Chagas disease (CD) diagnosis; however, its performance depends on the antigen preparation adsorbed to the solid phase, which may lead to false-positive results and cross-reactions. The use of chimeric recombinant antigens can overcome this limitation. Four chimeric antigens from Trypanosoma cruzi (IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4) were developed and evaluated in phase I, II and III studies using indirect ELISA as diagnostic platform. However, peroxidase-labeled secondary anti-human IgG antibody, which is employed in indirect ELISAs, limits its use for the detection of species-specific and class-specific antibodies. To overcome this limitation, peroxidase-labeled antigens can be utilized, diagnosing both acute or chronic infection, in a species and immunoglobulin class-independent manner, through the use of a double-antigen sandwich ELISA (DAgS-ELISA). We aimed to evaluate and validate the diagnostic performance of the chimeric antigens IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4 in the DAgS-ELISA platform. METHODOLOGY/PRINCIPAL FINDINGS: DAgS-ELISA was optimized by checkerboard titration. In phase I study, 207 positive and 205 negative samples were evaluated. Cross-reactivity to other infections was also assessed using 68 samples. The selected conditions for the tests utilized 25 ng of antigen per well and the conjugate diluted at 1:2,000 for all molecules. In the phase I study, the areas under the curve of IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4 were 98.7%, 99.5%, 98.6% and 98.8%, respectively. Among the positive samples, IBMP-8.1 antigen classified 53 (25.6%) as false negative, IBMP-8.2, 27 (13%), IBMP-8.3, 24 (11.6%) and IBMP-8.4, 43 (20.8%), giving sensitivities of 74.4%, 87%, 88.4% and 79.2%, respectively. The only antigen that did not reach 100% specificity was IBMP-8.3, with 96.6%. IBMP-8.3 was also the only molecule to show cross-reactivity with HTLV. CONCLUSIONS/SIGNIFICANCE: DAgS-ELISA is a promising tool for immunodiagnosis, and despite the high AUC values, the performance of this assay was different from the values obtained by our group when using these antigens in the indirect ELISA, for this reason, improvements are being considered to increase the sensitivity of the DAgS-ELISA.


Assuntos
Doença de Chagas , Trypanosoma cruzi , Anticorpos Antiprotozoários , Antígenos , Antígenos de Protozoários , Doença de Chagas/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Peroxidase , Sensibilidade e Especificidade , Trypanosoma cruzi/genética
8.
Biosensors (Basel) ; 11(8)2021 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-34436091

RESUMO

The performance of an immunoassay relies on antigen-antibody interaction; hence, antigen chemical stability and structural integrity are paramount for an efficient assay. We conducted a functional, thermostability and long-term stability analysis of different chimeric antigens (IBMP), in order to assess effects of adverse conditions on four antigens employed in ELISA to diagnose Chagas disease. ELISA-based immunoassays have served as a model for biosensors development, as both assess molecular interactions. To evaluate thermostability, samples were heated and cooled to verify heat-induced denaturation reversibility. In relation to storage stability, the antigens were analyzed at 25 °C at different moments. Long-term stability tests were performed using eight sets of microplates sensitized. Antigens were structurally analyzed through circular dichroism (CD), dynamic light scattering, SDS-PAGE, and functionally evaluated by ELISA. Data suggest that IBMP antigens are stable, over adverse conditions and for over a year. Daily analysis revealed minor changes in the molecular structure. Functionally, IBMP-8.2 and IBMP-8.3 antigens showed reactivity towards anti-T. cruzi antibodies, even after 72 h at 25 °C. Long-term stability tests showed that all antigens were comparable to the control group and all antigens demonstrated stability for one year. Data suggest that the antigens maintained their function and structural characteristics even in adverse conditions, making them a sturdy and reliable candidate to be employed in future in vitro diagnostic tests applicable to different models of POC devices, such as modern biosensors in development.


Assuntos
Doença de Chagas/diagnóstico , Testes Imunológicos , Antígenos , Antígenos de Protozoários , Doença de Chagas/imunologia , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoensaio , Proteínas Recombinantes de Fusão , Sensibilidade e Especificidade
9.
Braz J Microbiol ; 52(4): 2069-2073, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34342836

RESUMO

Serological assays are important tools to identify previous exposure to SARS-CoV-2, helping to track COVID-19 cases and determine the level of humoral response to SARS-CoV-2 infections and/or immunization to future vaccines. Here, the SARS-CoV-2 nucleocapsid protein was expressed in Escherichia coli and purified to homogeneity and high yield using a single chromatography step. The purified SARS-CoV-2 nucleocapsid protein was used to develop an indirect enzyme-linked immunosorbent assay for the identification of human SARS-CoV-2 seroconverts. The assay sensitivity and specificity were determined analyzing sera from 140 RT-qPCR-confirmed COVID-19 cases and 210 pre-pandemic controls. The assay operated with 90% sensitivity and 98% specificity; identical accuracies were obtained in head-to-head comparison with a commercial ELISA kit. Antigen-coated plates were stable for up to 3 months at 4 °C. The ELISA method described is ready for mass production and will be an additional tool to track COVID-19 cases.


Assuntos
COVID-19 , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Ensaio de Imunoadsorção Enzimática , Soroconversão , Anticorpos Antivirais/sangue , COVID-19/diagnóstico , COVID-19/imunologia , Humanos , Imunidade Humoral , Proteínas do Nucleocapsídeo/genética , Fosfoproteínas/imunologia , Sensibilidade e Especificidade
10.
Transfusion ; 61(9): 2701-2709, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34240750

RESUMO

BACKGROUND: Chagas disease (CD) serological screening at blood banks is usually performed by a single highly sensitive serological assay, with chemiluminescent immunoassays (CLIAs) being the method of choice. CLIAs employ recombinant, fusion peptides and/or chimeric antigens that selectively capture anti-Trypanosoma cruzi antibodies. However, despite high sensitivity, the ability of these tests to identify CD-positive cases should be evaluated against T. cruzi strains circulating in specific locales. Herein, we used a latent class analysis (LCA) approach employing an array of four chimeric antigens to assess the diagnostic performance of the Liaison XL Murex Chagas CLIA for the detection of anti-T. cruzi IgG in serum samples. STUDY DESIGN AND METHODS: The study included a panel of 5014 serum samples collected from volunteer blood donors at the Hematology and Hemotherapy Foundation of the State of Bahia, submitted to anti-T. cruzi antibody detection using Liaison Chagas CLIA and LCA as a reference test in the absence of a gold standard. RESULTS: LCA classified 4993 samples as negative, while positivity for T. cruzi antibodies was predicted in 21 samples. Compared with LCA, CLIA demonstrated sensitivity and specificity of 76.2% and 99.5%, respectively, providing an overall accuracy of 99.4%. DISCUSSION: In blood banks lacking a de facto highly sensitive screening immunoassay, the low sensitivity offered by Liaison Chagas CLIA renders it unsuitable for standalone use in serological screening procedures for CD. Moreover, blood banks are encouraged to carefully assess the ability of diagnostic methods to identify local T. cruzi strains in circulation.


Assuntos
Doadores de Sangue , Segurança do Sangue , Doença de Chagas/diagnóstico , Trypanosoma cruzi/isolamento & purificação , Anticorpos Antiprotozoários/sangue , Anticorpos Antiprotozoários/imunologia , Antígenos de Protozoários/sangue , Antígenos de Protozoários/imunologia , Doença de Chagas/sangue , Doença de Chagas/imunologia , Humanos , Medições Luminescentes , Trypanosoma cruzi/imunologia
11.
Vaccine ; 39(33): 4723-4732, 2021 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-34053789

RESUMO

BACKGROUND: The infection caused by the protozoan Trypanosoma cruzi affects humans and is called as Chagas disease. Currently, the main measures available to reduce the incidence of this disease are drug treatment and vector control. Traditionally, the development of vaccines occurs mainly through the use of antigenic candidates of the etiologic agent in the form of a vaccine preparation. Virus-like particles (VLPs) are structures analogous to viral capsids composed essentially of structural proteins and are widely used in vaccination protocols because of their immunostimulatory properties. In this context, the objective of this study was to use strategies in a murine immunization model to characterize the immunostimulatory capacity of VLPs from Triatoma virus (TrV-VLPs), analysed in the presence or absence of the aluminium vaccine adjuvant. In parallel, to characterize the immunogenic behaviour of four T. cruzi chimeric recombinant proteins (mix-IBMP) associated with TrV-VLPs or aluminium vaccine adjuvant. METHOD: We immunized BALB/c mice once or twice, depending on the strategy, and collected serum samples at 15, 30 and 45 days after the immunization. Subsequently, serum samples from animals immunized with TrV-VLPs were used to determine total IgG, IgG1, IgG2a, IgG2b and IgG3 anti-TrV-VLPs by enzyme-linked immunosorbent assay (ELISA). RESULTS: Data obtained demonstrate the ability of TrV-VLPs to preferably induce IgG2b and IgG3 type antibodies in the absence of aluminium adjuvant. In fact, the use of aluminium did not interfere with the total IgG profile of anti-TrV-VLPs. Interestingly, mix-IBMP had a better profile of total IgG, IgG1 and IgG3 subclasses when mixed with TrV-VLPs. CONCLUSION: In conclusion, these results suggest the potential of TrV-VLPs as a vaccine adjuvant and the use of T. cruzi chimeric antigens as a rational strategy for the development of vaccines against the experimental model of Chagas disease.


Assuntos
Doença de Chagas , Dicistroviridae , Trypanosoma cruzi , Animais , Doença de Chagas/prevenção & controle , Camundongos , Camundongos Endogâmicos BALB C
12.
Biomed Res Int ; 2020: 1803515, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32908871

RESUMO

Despite several available methodologies for Chagas disease (CD) serological screening, the main limitation of chronic CD diagnosis is the lack of effective tools for large-scale screening and point-of-care diagnosis to be used in different CD epidemiological scenarios. Taking into account that developing such a diagnostic tool will significantly improve the ability to identify CD carriers, we aimed at performing a proof-of-concept study (phase I study) to assess the use of these proteins in a point-of-care platform using serum samples from different geographical settings of Brazil and distinct clinical presentations. The diagnostic accuracy study was conducted on a panel of two WHO International Standards (IS) and 14 sera from T. cruzi-positive and 16 from T. cruzi-negative individuals. The results obtained with the test strips were converted to digital images, allowing quantitative comparison expressed as a relative band intensity ratio (RBI). The diagnostic potential and performance were also determined. Regardless of the geographical origin or clinical presentation, all sera with T. cruzi antibodies returned positive both for IBMP-8.1 and IBMP-8.4 chimeric antigens. The area under the ROC curve (AUC) values was 100% for both antigens, demonstrating an outstanding overall diagnostic accuracy (100%). Based on the data, we believe that the lateral flow assays based on these antigens are promising methodologies for screening CD.


Assuntos
Anticorpos Antiprotozoários/sangue , Antígenos de Protozoários/imunologia , Doença de Chagas/diagnóstico , Imunoensaio/métodos , Trypanosoma cruzi/imunologia , Antígenos de Protozoários/genética , Brasil , Doença de Chagas/imunologia , Doença de Chagas/parasitologia , Cromatografia de Afinidade/instrumentação , Cromatografia de Afinidade/métodos , Ensaio de Imunoadsorção Enzimática/instrumentação , Ensaio de Imunoadsorção Enzimática/métodos , Desenho de Equipamento , Humanos , Imunoensaio/instrumentação , Testes Imediatos , Estudo de Prova de Conceito , Proteínas de Protozoários/genética , Proteínas de Protozoários/imunologia , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/imunologia , Trypanosoma cruzi/genética
13.
Biosens Bioelectron ; 169: 112573, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32905944

RESUMO

In this work, a dual detection system based on an impedimetric immunosensor was developed for the first time for the simultaneous detection of anti-Trypanosoma cruzi and anti-Leishmania infantum antibodies in human and dog serum samples. The IBMP 8.1 and rLci1A/rLci2B recombinant antigens were immobilized over the surface of dual screen-printed carbon electrodes (W1 and W2) modified with poly (4-hydroxyphenylacetic acid). Under optimized conditions, the immunosensor recognized specific interactions for anti-T. cruzi antibodies up to a dilution of 1:10,240 and for anti-L. infantum up to 1:5120 in canine serum samples. Relative standard deviation (RSD) values of 2.8% for W1 and 3.6% for W2 were obtained for T. cruzi (W1) and L. infantum antigen (W2) samples in three different electrodes for 3 days (n = 9). The immunosensor was stored at 4 °C for 8 weeks, with activity retention of 70.2% in W1 and 78.2% in W2. The results using the recombinant proteins revealed that all antigens discriminated between negative and positive samples (p < 0.0001) in both dog and human groups, as well as no cross-reactivity could be detected among sera with other infections. With this approach, immunosensor-based diagnostic tests achieved 100% accuracy, suggesting that the antigens are eligible to enter Phase-II studies.


Assuntos
Técnicas Biossensoriais , Doenças do Cão , Leishmania infantum , Leishmaniose Visceral , Animais , Anticorpos Antiprotozoários , Antígenos de Protozoários , Cães , Imunoensaio , Leishmaniose Visceral/diagnóstico , Leishmaniose Visceral/veterinária , Sistemas Automatizados de Assistência Junto ao Leito
15.
J Clin Microbiol ; 57(8)2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31189586

RESUMO

Chimeric T. cruzi antigens have been proposed as a diagnostic tool for chronic Chagas disease (CD) in both settings where Chagas disease is endemic and those where it is not endemic. Antibody response varies in accordance to each T. cruzi strain, presenting challenges to the use of antigens lacking demonstrated cross-reactivity with Leishmania spp. Our group expressed four chimeric proteins (IBMP-8.1, IBMP-8.2, IBMP-8.3, and IBMP-8.4) and previously assessed their diagnostic performance to determine cross-reactivity with Leishmania spp. Here, we validated our findings using serum samples from different Brazilian geographic areas reporting endemic Chagas disease, endemic visceral or American cutaneous leishmaniasis (ACL), or both. Overall, 829 serum samples were evaluated using commercial and IBMP enzyme-linked immunosorbent assays. Due to the absence of a reference assay to diagnosis CD, latent class analysis (LCA) was performed through the use of a statistical model. The incidence of cross-reactivity for ACL-positive samples varied from 0.35% (IBMP-8.3) to 0.70% (IBMP-8.1 and IBMP-8.2). Regarding visceral leishmaniasis (VL)-positive samples, the IBMP-8.2 and IBMP-8.3 antigens cross-reacted with six (3.49%) and with only one sample (0.58%), respectively. No cross-reactivity with either ACL or VL was observed for the IBMP-8.4 antigen. Similarly, no cross-reactions were found when VL-positive samples were assayed with IBMP-8.1. The agreement among the results obtained using IBMP antigens ranged from 97.3% for IBMP-8.2 and 99% for IBMP-8.1 and IBMP-8.3 to 100% for IBMP-8.4, demonstrating almost perfect agreement with LCA. Accordingly, in light of the negligible cross-reactivity with both ACL and VL, we suggest the use of IBMP antigens in regions where T. cruzi and Leishmania spp. are coendemic.


Assuntos
Anticorpos Antiprotozoários/sangue , Antígenos de Protozoários/imunologia , Doença de Chagas/diagnóstico , Doença de Chagas/imunologia , Reações Cruzadas , Proteínas Recombinantes de Fusão/imunologia , Antígenos de Protozoários/genética , Doenças Endêmicas/estatística & dados numéricos , Ensaio de Imunoadsorção Enzimática , Humanos , Análise de Classes Latentes , Leishmaniose Cutânea/epidemiologia , Leishmaniose Visceral/epidemiologia , Proteínas Recombinantes de Fusão/genética , Sensibilidade e Especificidade , Trypanosoma cruzi/genética , Trypanosoma cruzi/imunologia
16.
PLoS Negl Trop Dis ; 13(6): e0007545, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31242195

RESUMO

BACKGROUND: Dogs are considered sentinels in areas of Trypanosoma cruzi transmission risk to humans. ELISA is generally the method of choice for diagnosing T. cruzi exposure in dogs, but its performance substantially depends on the antigenic matrix employed. In previous studies, our group has developed four chimeric antigens (IBMP-8.1, 8.2, 8.3, and 8.4) and evaluated their potential for diagnosing T. cruzi exposure in humans. For human sera, these chimeric antigens presented superior diagnostic performances as compared to commercial tests available in Brazil, Spain, and Argentina. Therefore, in this study we have evaluated the potential of these antigenic proteins for detection of anti-T. cruzi IgG antibodies in dog sera. METHODOLOGY/PRINCIPAL FINDINGS: The IBMP-ELISA assays were optimized by checkerboard titration. Subsequently, the diagnostic potential was validated through analysis of ROC curves and the performance of the tests was determined using double entry tables. Cross-reactivity was also evaluated for babesiosis, ehrlichiosis, dirofilariosis, anaplasmosis, and visceral leishmaniasis. Best performance was shown by IBMP-8.3 and IBMP-8.4, although all four antigens demonstrated a high diagnostic performance with 46 positive and 149 negative samples tested. IBMP-8.3 demonstrated 100% sensitivity, followed by IBMP-8.4 (96.7-100%), IBMP-8.2 (73.3-87.5%), and IBMP-8.1 (50-100%). The highest specificities were achieved with IBMP-8.2 (100%) and IBMP-8.4 (100%), followed by IBMP-8.3 (96.7-97.5%) and IBMP 8.1 (89.1-100%). CONCLUSIONS/SIGNIFICANCE: The use of chimeric antigenic matrices in immunoassays for anti-T. cruzi IgG antibody detection in sera of infected dogs was shown to be a promising tool for veterinary diagnosis and epidemiological studies. The chimeric antigens used in this work allowed also to overcome the common hurdles related to serodiagnosis of T. cruzi infection, especially regarding variation of efficiency parameters according to different strains and cross-reactivity with other infectious diseases.


Assuntos
Anticorpos Antiprotozoários/sangue , Doença de Chagas/veterinária , Doenças do Cão/diagnóstico , Proteínas Recombinantes de Fusão/imunologia , Testes Sorológicos/métodos , Trypanosoma cruzi/imunologia , Animais , Doença de Chagas/diagnóstico , Cães , Imunoglobulina G/sangue , Curva ROC , Sensibilidade e Especificidade
17.
PLoS One ; 14(4): e0215623, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30998741

RESUMO

BACKGROUND: Laboratory diagnosis of chronic Chagas disease is a troubling factor due to lack of reference tests. The WHO suggests the use of two distinct commercial serological tests in parallel. The performance of commercial immunoassays might fluctuate depending on the antigenic matrices and the local strains of T. cruzi in different geographical settings. The use of antigenic matrices based on chimeric proteins can solve these limitations. Here, we evaluated the diagnostic performance of two chimeric T. cruzi antigens (IBMP-8.1 and -8.4) to diagnose chronic Chagas disease in individuals from endemic South American countries. METHODOLOGY/PRINCIPAL FINDINGS: IBMP-8.1 and IBMP-8.4 chimeric antigens were expressed as soluble proteins in E. coli and purified using chromatography methods. Reactivity of IBMP-8.1 and IBMP-8.4 was assessed using an in-house ELISA with sera from 122 non-infected and 215 T. cruzi-infected individuals from Argentina, Bolivia, and Paraguay. Cut-off values were based on ROC curves and performance parameters were determined using a dichotomous approach. Area under the curve values were > 99.7% for both IBMP-8.1 and IBMP-8.4 antigens. IgG levels in T. cruzi-positive and negative samples were higher for IBMP-8.4 than IBMP-8.1. Both IBMP-8.1 and -8.4 were 100% specific, while IBMP-8.4 were 100% sensitive compared to IBMP-8.1 (95.3%). Admitting RI values of 1.0 ± 0.10 as the inconclusive interval, 6.2% of the samples tested using IBMP-8.1 and 2.1% using IBMP-8.4 fell inside the grey zone. Based on accuracy and diagnostic odds ratio values, IBMP-8.4 presented the best performance. Differences in sensitivity and IgG levels among the samples from Argentina, Bolivia, and Paraguay were not significant. CONCLUSIONS/SIGNIFICANCE: Our findings showed a notable performance of IBMP-8.1 and -8.4 chimeric antigens in diagnosing chronic Chagas disease in individuals from endemic South American countries, confirming our hypothesis that these antigens could be used in geographical areas where distinct T. cruzi DTUs occur.


Assuntos
Anticorpos Antiprotozoários/sangue , Antígenos de Protozoários/química , Doença de Chagas/sangue , Imunoglobulina G/sangue , Trypanosoma cruzi , Doença de Chagas/epidemiologia , Doença Crônica , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Proteínas Recombinantes de Fusão/química , América do Sul/epidemiologia
18.
BMC Infect Dis ; 19(1): 251, 2019 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-30871504

RESUMO

BACKGROUND: Chronic Chagas Disease (CD) diagnosis is based on serological methods employing crude, semipurified or recombinant antigens, which may result in low sensitivity or cross-reactivity. To reduce these restrictions, we developed a strategy involving use of molecules containing repetitive fragments of Trypanosoma cruzi conserved proteins. Diagnostic performance of IBMP-8.1 and IBMP-8.4 chimeric antigens (Molecular Biology Institute of Paraná - IBMP in Portuguese acronym) was assessed to diagnose T. cruzi-infected and non-infected immigrants living in Barcelona (Spain), a non-endemic setting for Chagas disease. METHODS: Reactivity of IBMP-8.1 and IBMP-8.4 was assessed using an in-house automated ELISA with 347 positive and 331 negative individuals to Chagas disease. Antigenic cross-reactivity was measured with sera samples from pregnant women with Toxoplasma gondii (n = 98) and Zika virus (n = 75) antibodies. RESULTS: The area under the curve values was 1 and 0.99 for the IBMP-8.1 and IBMP-8.4 proteins, respectively, demonstrating excellent diagnostic accuracy. The reactivity index was higher for IBMP-8.1 than IBMP-8.4 in positive samples and no significant difference in reactivity index was observed in negative samples. Sensitivity ranged from 99.4% for IBMP-8.1 to 99.1% for IBMP-8.4 and was not statistically different. Specificity for IBMP-8.1 reached 100 and 99.7% for IBMP-8.4, both nearly 100% accurate. No antigenic cross-reactivity was observed and reactivity index was similar to that for negative Chagas disease individuals. CONCLUSIONS: Our results showed an outstanding performance of IBMP-8.1 and IBMP-8.4 chimeric antigens by ELISA and suggest both chimeric antigens could also be used for Chagas disease diagnosis in immigrants living in non-endemic settings.


Assuntos
Doença de Chagas/imunologia , Trypanosoma cruzi/imunologia , Adulto , Anticorpos Antiprotozoários/imunologia , Antígenos de Protozoários/genética , Antígenos de Protozoários/imunologia , Doença de Chagas/diagnóstico , Doença de Chagas/parasitologia , Reações Cruzadas , Emigrantes e Imigrantes/estatística & dados numéricos , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Gravidez , Sensibilidade e Especificidade , Espanha , Toxoplasma/genética , Toxoplasma/imunologia , Trypanosoma cruzi/genética
19.
PLoS Negl Trop Dis ; 12(10): e0006871, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30365504

RESUMO

BACKGROUND: Canine Visceral leishmaniasis (CVL) is a serious public health problem, thus for its control, the Ministry of Health in Brazil recommends the rapid diagnosis and euthanasia of seropositive dogs in endemic areas. Therefore, our group had previously selected six recombinant proteins (rLci1, rLci2, rLci4, rLci5, rLci8, and rLci12) due to their high potential for CVL diagnostic testing. The present study aims to produce an immunodiagnostic test using the aforementioned antigens, to improve the performance of the diagnosis of CVL recommended by Brazilian Ministry of Health. METHODOLOGY/PRINCIPAL FINDINGS: To evaluate the recombinant proteins in the serological assays, positive and negative samples were selected based on parasitological test (culture) and molecular test (qPCR) of splenic aspirate. Initially, we selected 135 dog serum samples, 73 positives (symptomatic and asymptomatic) and 62 negatives to screen recombinant proteins on ELISA platform. Then, for rLci5 ELISA validation, 361 serum samples collected in a cross-sectional study were selected, being 183 positives (symptomatic and asymptomatic) and 178 negatives. In the screening of the recombinant proteins, rLci5 was the only protein to present a performance statistically higher than the performance presented by EIE-LVC test, presenting 96% (IC 95%; 85-99%) vs. 83% (IC 95%; 69-92%) of sensitivity for symptomatic dogs, 71% (IC 95%; 49-97%) vs. 54% (IC 95%; 33-74%) for asymptomatic dogs and 94% (IC 95%; 83-99%) vs, 88% (IC 95%; 76-95% of specificity. Thus, the rLci5 protein was selected to compose a final ELISA test. Validation of rLci5 ELISA showed 87% (IC 81-91%) of sensitivity, 94% (IC 95%; 90-97%) of specificity and 90% accuracy. Testing the EIE-LVC with the same validation panel, we observed a lower performance when compared to ELISA rLci5 (sensitivity of 67% (IC 95%; 59-74%), specificity of 87% (IC 95%; 81-92%), and accuracy of 77%). Finally, the performance of current CVL diagnostic protocol recommended by Brazilian Ministry of Health, using DPP-LVC as screening test and EIE-LVC as confirmatory test, was compared with a modified protocol, replacing EIE-LVC by rLci5 ELISA. The current protocol presented a sensitivity of 59% (IC 95%; 52-66%), specificity of 98% (IC 95%; 95-99%) and accuracy of 80% (IC 95%; 76-84%), while the modified protocol presented a sensitivity of 71% (IC 95%; 63-77%), specificity of 99% (IC 95%; 97-100%) and accuracy of 86% (IC 95%; 83-89%). CONCLUSION: Thus, we concluded that rLci5 ELISA is a promising test to replace EIE-LVC test and increase the diagnostic performance of CVL in Brazil.


Assuntos
Antígenos de Protozoários/imunologia , Doenças do Cão/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Flagelos/imunologia , Leishmania/imunologia , Leishmaniose Visceral/veterinária , Testes Sorológicos/métodos , Animais , Brasil , Estudos Transversais , Cães , Leishmaniose Visceral/diagnóstico , Proteínas Recombinantes/imunologia , Sensibilidade e Especificidade
20.
Am J Trop Med Hyg ; 99(5): 1174-1179, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30226130

RESUMO

The existence of an imperfect reference standard presents complications when evaluating the unbiased performance of novel diagnostic techniques. This is especially true in the absence of a gold standard, as is the case in chronic Chagas disease (CD) diagnosis. To circumvent this constraint, we elected to use latent class analysis (LCA). Previously, our group demonstrated the high performance of four Trypanosoma cruzi-chimeric proteins (Molecular Biology Institute of Paraná [IBMP]-8.1, -8.2, -8.3, and -8.4) for CD diagnosis using several distinct immunoassays. Although commercial tests had previously been established as a reference standard, the diagnostic performance of these chimeric antigens could present bias because these tests fail to produce 100% accurate results. Thus, we used LCA to assess the performance of these IBMP chimeric antigens in chronic CD diagnosis. Using the LCA model as a gold standard, sensitivity and specificity values ranged from 93.5% to 99.4% and 99.6% to 100%, respectively. The accuracy values were 96.2% for IBMP-8.2, approximately 98% for IBMP-8.1 and IBMP-8.3, and nearly 100% for IBMP-8.4. For IBMP-8.1 and IBMP-8.2, higher positive predictive values were associated with increases in hypothetical prevalence. Similarly, higher hypothetical prevalence resulted in lower negative predictive values for IBMP-8.1, IBMP-8.2, and IBMP-8.3. In addition, samples with serodiscordant results from commercial serological tests were analyzed using LCA. Molecular Biology Institute of Paraná -8.1 demonstrated potential for use in confirmatory testing with regard to samples with inconsistent results. Moreover, our findings further confirmed the remarkable performance of the IBMP-8.4 antigen to diagnose chronic CD in both endemic and non-endemic areas.


Assuntos
Antígenos de Protozoários/imunologia , Doença de Chagas/diagnóstico , Análise de Classes Latentes , Testes Sorológicos/normas , Trypanosoma cruzi/imunologia , Antígenos de Protozoários/genética , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Proteínas de Protozoários/genética , Proteínas de Protozoários/imunologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Testes Sorológicos/métodos , Trypanosoma cruzi/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...