Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Gen Dent ; 63(4): 28-32, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26147164

RESUMO

The aim of this study was to evaluate the microtensile bond strengths of a self-etching adhesive to dentin surfaces after treatment with 4 different hemostatic agents in the presence of saliva and blood. After testing, no significant differences were found between the mean bond strength of Clearfil SE (CSE) Bond resin adhesive to normal dentin and those of CSE to dentin treated with the hemostatic agents ViscoStat Clear, Astringedent, or Astringedent X (P > 0.05). However, the mean bond strength of CSE Bond to dentin treated with Ankaferd Blood Stopper (ABS) was significantly greater than those of the other groups (P < 0.05). Thus, while 3 of the tested hemostatic agents did not have significant effects on the bond strength of composite resin to dentin, ABS increased the bond strength of CSE Bond to dentin.


Assuntos
Sangue/metabolismo , Dentina/metabolismo , Hemostáticos/farmacologia , Saliva/metabolismo , Autocura de Resinas Dentárias , Análise do Estresse Dentário , Dentina/efeitos dos fármacos , Humanos , Cimentos de Resina/uso terapêutico , Autocura de Resinas Dentárias/métodos , Resistência à Tração
2.
Dent Mater ; 31(7): e141-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25979794

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the elution of Bis-GMA, TEGDMA, HEMA, and Bis-EMA monomers from six bulk fill composite resins over four different time periods, using HPLC. METHODS: Six different composite resin materials were used in the present study: Tetric Evo Ceram Bulk Fill (Ivoclar Vivadent, Amherst, NY), X-tra Fill (VOCO, Cuxhaven, Germany), Sonic Fill (Kerr, Orange, CA, USA), Filtek Bulk Fill (3M ESPE Dental Product, St. Paul, MN), SDR (Dentsply, Konstanz, Germany), EQUIA (GC America INC, Alsip, IL). The samples (4mm thickness, 5mm diameter) were prepared and polymerized for 20s with a light emitted diode unit. After fabrication, each sample was immediately immersed in 75wt% ethanol/water solution used as extraction fluid and stored in the amber colored bottles at room temperature. Ethanol/water samples were taken (0.5mL) at predefined time intervals:10m (T1), 1h (T2), 24h (T3) and 30 days (T4). These samples were analyzed by HPLC. The obtained data were analyzed with one-way ANOVA and Tukey HSD at significance level of p<0.05. RESULTS: Amount of eluted Bis-EMA and Bis-GMA from Tetric Evo Ceram Bulk Fill and amount of eluted TEGDMA and HEMA from X-tra Fill higher than others composites (p<0.05). SIGNIFICANCE: Residual monomers were eluted from bulk fill composite resins in all time periods and the amount of eluted monomers was increased with time.


Assuntos
Cromatografia Líquida de Alta Pressão , Resinas Compostas/química , Bis-Fenol A-Glicidil Metacrilato/química , Metacrilatos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Fatores de Tempo
3.
Dent Mater J ; 33(1): 92-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24492118

RESUMO

The purpose of this study was to investigate the dentin bond durability of a one-step, fluoride-containing, glass ionomer-based adhesive system, Reactmer Bond (RB), and that of a two-step, fluoride-containing, self-etch adhesive system, Clearfil Protect Bond (CPB). Enamel was removed from the occlusal surfaces of teeth, and flat dentin surfaces were entirely covered with a composite resin following the application of an adhesive material (n=10). After specimens were sectioned into rectangular sticks of 0.87 ± 0.03 mm(2), the sticks were randomly assigned into two accelerated aging time period groups: 1 week or 1 year. Microtensile bond strengths were determined. Bond strength of RB increased significantly after 1 year (1 week=27.80 ± 10.57 MPa versus 1 year=36.93 ± 14.38 MPa) (p<0.05). In contrast, there was no significant difference in bond strength between the two time periods for CPB (1 week=51.74 ± 17.8 MPa versus 1 year=56.03 ± 18.85 MPa) (p>0.05). Both fluoride-containing adhesives seemed to demonstrate reliable bonding performance after 1 year of accelerated aging in water.


Assuntos
Adesivos Dentinários/química , Cimentos de Ionômeros de Vidro/química , Resinas Compostas/química , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Teste de Materiais , Dente Molar , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
4.
Eur J Dent ; 7(1): 102-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23407765

RESUMO

OBJECTIVE: The objective of this study was to compare the conversion degree of six different composite materials (Filtek Z 250, Filtek P60, Spectrum TPH, Pertac II, Clearfil AP-X, and Clearfil Photo Posterior) using three different light sources (blue light-emitting diode [LED], plasma arc curing [PAC], and conventional halogen lamp [QTH]). METHODS: Composites were placed in a 2 mm thick and 5 mm diameter Teflon molds and light cured from the top using three methods: LED for 40 s, PAC for 10 s, and QTH for 40 s. A Fourier Transform Infrared Spectroscopy (FTIR) was used to evaluate the degree of conversion (DC) (n=5). The results were analyzed with two-way analysis of variance and Tukey HSD test. RESULTS: DC was significantly influenced by two variables, light source and composite (P<.05). QTH revealed significantly higher DC values than LED (P<.05). However, there were no significant differences between DC values of QTH and PAC or between DC values of LED and PAC (P>.05). The highest DC was observed in the Z 250 composite specimens following photopolymerization with QTH (70%). The lowest DC was observed in Clearfil Photo Posterior composite specimens following photo-polymerization with LED (43%). CONCLUSIONS: The DC was found to be changing according to both light sources and composite materials used. Conventional light halogen (QTH) from light sources and Filtek Z 250 and Filtek P 60 among composite materials showed the most DC performance.

5.
Acta Odontol Scand ; 71(3-4): 703-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23039068

RESUMO

OBJECTIVE: The aim of this study was to evaluate the effect of luting cement thicknesses on the push-out bond strength of the fiber posts. MATERIALS AND METHODS: Sixty human maxillary canine teeth were endodontically treated. Post spaces were prepared and root specimens randomly divided into three groups: Group 1: etch-and-rinse (Variolink II/Exite DSC), Group 2: self-etch (Panavia F2.0/ED primer) and Group 3: self-adhesive (Clearfil SA Cement). Then each group was divided into four sub-groups according to the cement thickness, as follows: Sub-group 1: 0.35 mm, Sub-group 2: 0.25 mm, Sub-group 3: 0.15 mm, and Sub-group 4: 0.05 mm. Three slices of 1 mm thickness were obtained from each root specimen (n = 15). Push-out tests were performed and data was analyzed with two-way ANOVA and Tukey tests. RESULTS: The etch-and-rinse system (Variolink II) had a significantly higher bond strength compared with the other systems (p < 0.05). The thickest cement group (0.35 mm) had a significantly lower bond strength compared with the 0.15 and 0.05 mm groups in the etch-and-rinse and self-adhesive groups (p < 0.05). In the self-etch group, the cement thicknesses did not significantly affect the bond strength (p > 0.05). CONCLUSIONS: The etch-and-rinse system offered better bonding to root dentine than the self-adhesive and self-etch systems. The increases in cement thickness significantly reduced the bond strength of fiber posts to root dentine for both the etch-and-rinse and self-adhesive systems.


Assuntos
Cimentos Dentários , Teste de Materiais , Análise de Variância , Dente Canino , Humanos
6.
Odontology ; 101(2): 204-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23011473

RESUMO

This study evaluated the influence of eugenol on the push-out bond strengths of fiber posts cemented with different types of resin luting agents. Seventy-two extracted maxillary single-rooted canine teeth were randomly divided into two groups of 36 teeth. Group 1, the control group, was filled with gutta-percha only (i.e., did not receive eugenol), whereas group 2 was filled with a eugenol-containing sealer. All root canals were filled and each group was divided into three subgroups. The posts in each subgroup were cemented with the following materials: subgroup 1 with a 2-step self-etching adhesive system (Clearfil Liner Bond 2V + Panavia F); subgroup 2 with a 1-step self-etching adhesive (Panavia F); and subgroup 3 with a self-adhesive (Clearfil SA Cement). Dislodgement resistance was measured using a universal testing machine. All data were subjected to ANOVA using a factorial design and Tukey test (α = 0.05). The use of the eugenol-containing sealer significantly reduced the push-out bond strength of the fiber post (P < 0.05). The push-out bond strength of Panavia F was significantly higher than those of the other groups filled with the eugenol-containing sealer (P < 0.05). The Panavia F group was less susceptible to the inhibiting effect of eugenol than were the other evaluated groups when the fiber post was cemented in the canals filled with the eugenol-containing sealer.


Assuntos
Colagem Dentária , Resinas Epóxi , Eugenol/química , Dente Canino , Endodontia , Humanos
7.
Int J Periodontics Restorative Dent ; 32(3): e87-94, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22408783

RESUMO

The purpose of this randomized clinical trial was to determine the clinical wear behavior of three nanofilled composites (Filtek Supreme XT [FS], Tetric EvoCeram [TEC], and Aelite Aesthetic [AA]) with two indirect composites (Estenia [E] and Tescera ATL [TATL]) on permanent molar teeth. Fifty-four patients whose treatment plans included moderate Class I and/or II restorations on molar teeth were selected for inclusion in this study. Wear was measured by use of gypsum replicas at baseline and 6 and 12 months using three-dimensional scanning and rapid-form software to elucidate the wear mechanisms. For statistical analyses, one-way analysis of variance and the Scheffe test were used. Statistical results revealed that wear behavior of TATL was significantly different from that of AA (P < .05). No significant differences were detected between AA and E (P > .05) or between TEC, FS, and TATL composite resins (P > .05). The results showed similar clinical performance between the five composite resins evaluated. Therefore, composite resins may be indicated for the restoration of posterior teeth. However, the composition of the composite resin did affect the wear behavior of the composite material.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Desgaste de Restauração Dentária/classificação , Restauração Dentária Permanente/classificação , Condicionamento Ácido do Dente/métodos , Adulto , Cárie Dentária/terapia , Forramento da Cavidade Dentária/métodos , Preparo da Cavidade Dentária/classificação , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Restaurações Intracoronárias/classificação , Masculino , Teste de Materiais , Metacrilatos/química , Dente Molar/patologia , Nanocompostos/química , Poliuretanos/química , Técnicas de Réplica , Cimentos de Resina/química , Propriedades de Superfície , Adulto Jovem
8.
Int J Dent ; 2010: 864935, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20613961

RESUMO

The aim of this study was to investigate the efficiency of different diagnostic methods in detection of residual dentinal caries in excavated cavities. Fifty extracted molar with deep dentinal carious lesions were excavated using a slow-speed handpiece. All cavities were assessed by laser fluorescence(LF) device, electronic caries monitor(ECM), and caries detector dye(CDD) by three independent observers blindly. The measurements were repeated after two weeks. Specimens containing dentin slices 150 mum in thickness were prepared for histological analyses. The existence and absence of carious dentin was determined using a lightmicroscope. The average intraobserver accuracy was 1.00 (perfect agreement) for CDD, 0.86 (excellent agreement) for ECM, and 0.50 (good agreement) for LF. The average interobserver accuracy values were 0.92 (excellent agreement), (0.36 marginal agreement) and 0.48 (good agreement), for CDD, ECM, and LF, respectively. The average specificity was 0.60 for CDD, 73% for ECM, and 0.50 for LF. The average sensitivity was 0.55 for CDD, 0.85 for LF, and 0.47 for ECM. The average accuracy values were 0.53, 0.51, and 0.81 for CDD, ECM, and LF, respectively. LF had the greatest sensitivity and accuracy values of any of the methods tested. As a conclusion, LF device is appeared to most reliable method in detection of remain caries in cavity. However, because of its technical sensitivity it may susceptible to variations in measurements. To pay attention to the rule of usage and repeated measurements can minimize such variations in clinical practice. It was concluded that LF is an improvement on the currently available aids for residual caries detection.

9.
Dent Mater J ; 28(5): 620-6, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19822994

RESUMO

The aim of this study was to assess the clinical performance of three direct composite resins and two indirect inlay systems in posterior teeth using the modified USPHS criteria. A total of 100 restorations were placed in the molars of 54 patients by one operator. All restorations were directly evaluated by two examiners at baseline, 6 months, and 12 months. Statistical analysis was conducted using McNemar chi-square test at a significance level of 5% (p<0.05). Recall rate was 100% at 6 and 12 months, and all the restorations evaluated (i.e., 100%) received Alpha rating for the criteria of retention and gingival adaptation. At 12 months for the surface texture criterion, 80% of Filtek Supreme XT received Alpha rating while it was 95% for Tetric EvoCeram and AELITE Aesthetic. For marginal discoloration, 85% of Tescera ATL and Filtek Supreme XT received Alpha rating while it was 95% for Tetric EvoCeram and AELITE Aesthetic. Further, none of the restorative systems received a Charlie rating for any of the criteria at all evaluation periods. In summary, all the restorations demonstrated clinically satisfactory performance with no significant differences detected among them.


Assuntos
Resinas Compostas/uso terapêutico , Cárie Dentária/terapia , Restauração Dentária Permanente/métodos , Dente Molar/patologia , Nanocompostos/uso terapêutico , Adulto , Cárie Dentária/patologia , Preparo da Cavidade Dentária/classificação , Preparo da Cavidade Dentária/métodos , Adaptação Marginal Dentária , Falha de Restauração Dentária , Restauração Dentária Permanente/classificação , Estética Dentária , Humanos , Restaurações Intracoronárias/métodos , Estudos Longitudinais , Adulto Jovem
10.
Oper Dent ; 33(5): 526-33, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18833859

RESUMO

AIM: This study compared the fracture resistance of endodontically-treated mandibular molars with mesio-occluso-distal (MOD) cavities restored using different restoration techniques. METHODOLOGY: Sixty sound extracted mandibular molars were randomly assigned to six groups (n=10). Group 1 did not receive any preparation. The teeth in Groups 2-6 received root canal treatment and a MOD cavity preparation. The teeth in Group 2 were kept unrestored. Group 3 was restored conventionally with amalgam. Group 4 was restored with a dentin bonding system (DBS, Clearfil SE Bond) and resin composite (CR) (Clearfil Photoposterior). Group 5 was restored with indirect hybrid ceramic inlay material (Estenia). In Group 6, polyethylene ribbon fiber (Ribbond) was inserted into cavities in a buccal-to-lingual direction and the teeth were then restored with DBS and CR. After finishing and polishing, the specimens, except for Group 2, were loaded to failure by a chewing simulation device (60,000 cycles x 50 N load, 1.3 Hz frequency) in an artificial environment at 37 degrees C. Each tooth was subjected to compressive loading perpendicular to the occlusal surface at a crosshead speed of 1 mm/minute. The mean loads necessary to fracture were recorded in Newtons and the results were statistically analyzed. RESULTS: The mean fracture values were as follows: Group 1: 2485.3 +/- 193.98a, Group 2: 533.9 +/- 59.4a, Group 3: 1705.8 +/- 135.7a, Group 4: 2033.3 +/- 137.6cd, Group 5: 2121.3 +/- 156.5d, Group 6: 1908.9 +/- 132.2cd. There were statistically significant differences between the groups annotated with different letters. Thus, Group 1 (intact teeth) had the greatest fracture resistance and Group 2 (non-restored teeth) the poorest. No statistically significant differences were found between Groups 3 (amalgam), 4 (resin composite) and 6 (polyethylene ribbon fiber reinforced composite) (p > 0.05). Group 5 (indirect hybrid ceramic inlay) had greater fracture resistance than Group 3 (p < 0.05). CONCLUSIONS: Within the limitations of this study, although all of the restoration groups were stronger than the prepared-only group, none of the restoration techniques tested was able to completely restore the fracture resistance lost from MOD cavity preparation. However, use of indirect hybrid inlay restorations in these teeth may be recommended, because this restoration technique indicated more favorable fracture failure modes than other restoration techniques used in this study and particularly greater fracture strength than amalgam restorations. The promising result of indirect hybrid inlay restorations may need to be confirmed by long-term clinical studies.


Assuntos
Materiais Dentários/química , Restauração Dentária Permanente/métodos , Dente Molar/patologia , Fraturas dos Dentes/fisiopatologia , Dente não Vital/terapia , Força de Mordida , Resinas Compostas/química , Amálgama Dentário/química , Preparo da Cavidade Dentária/classificação , Polimento Dentário , Porcelana Dentária/química , Restauração Dentária Permanente/classificação , Adesivos Dentinários/química , Humanos , Restaurações Intracoronárias , Teste de Materiais , Polietilenos/química , Cimentos de Resina/química , Tratamento do Canal Radicular , Estresse Mecânico , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA