Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Crystallogr ; 55(Pt 2): 271-283, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35497654

RESUMO

A description and the performance of the very small angle neutron scattering diffractometer at the National Institute of Standards and Technology are presented. The measurement range of the instrument extends over three decades of momentum transfer q from 2 × 10-4 to 0.7 Å-1. The entire scattering angle range from 8 × 10-5 to π/6 rad (30°) can be measured simultaneously using three separate detector carriages on rails holding nine 2D detector arrays. Versatile choices of collimation options and neutron wavelength selection allow the q resolution and beam intensity to be optimized for the needs of the experiment. High q resolution is achieved using multiple converging-beam collimation with circular pinholes combined with refractive lenses and prisms. Relaxed vertical resolution with much higher beam intensity can be achieved with narrow slit collimation and a broad wavelength range chosen by truncating the moderator source distribution below 4 Šwith a Be crystalline filter and above 8 Šwith a supermirror deflector. Polarized beam measurements with full polarization analysis are also provided by a high-performance supermirror polarizer and spin flipper, capable of producing flipping ratios of over 100, along with a high-efficiency 3He polarization analyzer.

2.
J Appl Crystallogr ; 54(Pt 2): 461-472, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33953652

RESUMO

Measurements, calculations and design ideas to mitigate background caused by extraneous scattering in small-angle neutron scattering (SANS) instruments are presented. Scattering includes processes such as incoherent scattering, inelastic scattering and Bragg diffraction. Three primary sources of this type of background are investigated: the beam stop located in front of the detector, the inside lining of the detector vessel and the environment surrounding the sample. SANS measurements were made where materials with different albedos were placed in all three locations. Additional measurements of the angle-dependent scattering over the angular range of 0.7π-0.95π rad were completed on 16 different shielding materials at five wavelengths. The data were extrapolated to cover scattering angles from π/2 to π rad in order to estimate the materials' albedos. Modifications to existing SANS instruments and sample environments to mitigate extraneous scattering from surfaces are discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...