Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 48(1): 35-41, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37531641

RESUMO

AIMS: The aims of the study are to evaluate the performance of dual-energy computed tomography (DECT) imaging in the detection of noncalcified gallstones (GSs) and to assess its performance relative to transabdominal ultrasound (US) in identifying cholelithiasis. METHOD: This study is a retrospective review of radiology records and images to find all patients who had both US and DECT scans within a 6-month period and were found to have GSs. Patients who did not have GSs on US served as the control group. The CT scans were reviewed by 4 radiologists who did not have access to the US results when assessing the presence or absence of GSs on the DECT scans. In case of any discrepancies among the radiologists, the majority opinion was considered. If there was a split opinion, a fifth reviewer was consulted. The data were analyzed to calculate sensitivity, specificity, positive and negative predictive values, as well as overall accuracy and to evaluate interreader variability. The absolute Hounsfield unit (HU) differences of the GSs and bile were compared between polychromatic (PC), virtual noncontrast (VNC), and virtual monochromatic (VMC) images. RESULTS: Considering at least 3-reader agreement, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were found to be 92%, 96%, 96%, 92%, and 94%, respectively. Individual reader sensitivity varied between 87% and 92%. There was good interobserver agreement with a Fleiss' kappa of 0.76. Quantification of the whole data set showed that no significant difference was observed in the HU values for the stones between the PC images and the VNC images. A significant increase was observed on the 50-keV VMC images compared with the PC and VNC images. In the study group, 17% stones were visualized only on the VNC or/and 50-keV VMC images, and not on the PC images. On quantitative analysis of these cases, there was a significant increase of HU in the VNC images as compared with PC images and a significant decrease of HU in the 50-keV VMC images as compared with PC images. CONCLUSIONS: Low-keV images increase stone-bile contrast. Evaluation of cholelithiasis using VNC and 50-keV VMC images demonstrated a 14% increase in sensitivity relative to conventional CT.


Assuntos
Cálculos Biliares , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Cálculos Biliares/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Valor Preditivo dos Testes , Ultrassonografia , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
2.
Eur Stroke J ; 5(2): 169-173, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32637650

RESUMO

INTRODUCTION: About one-fourth of ischaemic strokes are classified as embolic strokes of undetermined source. Lambl's excrescences are commonly seen on cardiac valves, and data are limited on whether they may be a source of embolization. We examined the relationship between Lambl's excrescences and embolic stroke of undetermined source. PATIENTS AND METHODS: We performed a case-control study of patients in the Cornell AcutE Stroke Academic Registry. Stroke aetiologies were adjudicated using the Trial of Org 10172 in Acute Stroke Treatment and embolic stroke of undetermined source criteria. We included patients with acute ischaemic stroke between 2011 and 2016 who underwent transthoracic or transoesophageal echocardiography within six months of hospitalisation. Cases were embolic stroke of undetermined source patients and controls were patients with an identified, non-cardioembolic stroke aetiology (i.e. small- or large-vessel strokes). Multiple logistic regression was used to evaluate the association between Lambl's excrescences and embolic stroke of undetermined source after adjustment for demographics, comorbidities and mode of echocardiography. RESULTS: A total of 923 patients met the criteria for this analysis, including 530 with embolic stroke of undetermined source and 393 with small- or large-vessel strokes. Lambl's excrescences were identified in 47 (8.9%) patients with embolic stroke of undetermined source and 11 (2.8%) patients with small- or large-artery strokes, but the majority (54/58) of Lambl's excrescences were visualised on transoesophageal echocardiogram and embolic stroke of undetermined source patients were more likely to undergo transoesophageal echocardiogram. After adjustment for demographics, comorbidities and mode of echocardiography, we found no association between the presence of Lambl's excrescences and embolic stroke of undetermined source (odds ratio 0.9; 95% confidence interval 0.4-2.3). CONCLUSION: We found no association between Lambl's excrescences and embolic stroke of undetermined source. These results do not support the hypothesis that Lambl's excrescences are an occult cause of embolic stroke of undetermined source.

3.
Stroke ; 50(8): 2072-2079, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31272325

RESUMO

Background and Purpose- The clinical utility of positron emission tomography (PET) imaging in evaluating carotid artery plaque vulnerability remains unclear. Two tracers of recent interest for carotid plaque imaging are 18F-fluorodeoxyglucose (18F-FDG) and 18F-sodium fluoride (18F-NaF). We performed a systematic review and meta-analysis evaluating the association between carotid artery 18F-FDG or 18F-NaF uptake and recent or future cerebral ischemic events. Methods- A systematic review of Ovid MEDLINE, Ovid EMBASE, and the Cochrane library was conducted from inception to December 2017 for articles evaluating PET tracer uptake in recently symptomatic versus asymptomatic carotid arteries, and articles evaluating carotid uptake in relation to future ischemic events. Cerebral ischemic events were defined as ipsilateral strokes, transient ischemic attacks, or amaurosis fugax. We quantitatively pooled studies by a random-effects model when 3 or more studies were amenable for analysis. We assessed the standardized mean difference between tracer uptake in the symptomatic versus asymptomatic carotid artery using Cohen's d metric. Results- After screening 4144 unique articles, 13 prospective cohort studies assessing carotid artery 18F-FDG uptake in patients with recent cerebral ischemia were eligible for review. Eleven cohorts of 290 subjects scanned with 18F-FDG were eligible for meta-analysis. We found that carotid arteries ipsilateral to recent ischemic events had significantly higher 18F-FDG uptake than asymptomatic arteries (Cohen's d =0.492; CI=0.130-0.855; P=0.008) as well as significant heterogeneity (Cochran's Q =31.5; P=0.0005; I2=68.3%). Meta-regression was not performed due to the limited number of studies in the analysis. Only 2 studies investigating 18F-NaF PET imaging, and another 2 articles investigating ischemic event recurrence were found. Conclusions- Recent ipsilateral cerebral ischemia may be associated with increased carotid 18F-FDG uptake on PET imaging regardless of degree of carotid stenosis, although significant heterogeneity was found, and these results should be interpreted with caution. Emerging evidence suggests a similar association may be present with 18F-NaF plaque uptake. More studies are warranted to provide definitive conclusions on the utility of 18F-FDG or 18F-NaF in carotid plaque evaluation before investigating carotid PET as a diagnostic tool for cerebral ischemic events.


Assuntos
Isquemia Encefálica/etiologia , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Neuroimagem/métodos , Placa Aterosclerótica/diagnóstico por imagem , Humanos , Placa Aterosclerótica/complicações , Tomografia por Emissão de Pósitrons/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA