Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Indian Heart J ; 72(3): 145-150, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32768012

RESUMO

An echocardiographic investigation is one of the key modalities of diagnosis in cardiology. There has been a rising presence of cardiological comorbidities in patients positive for COVID-19. Hence, it is becoming extremely essential to look into the correct safety precautions, healthcare professionals must take while conducting an echo investigation. The decision matrix formulated for conducting an echocardiographic evaluation is based on presence or absence of cardiological comorbidity vis-à-vis positive, suspected or negative for COVID-19. The safety measures have been constructed keeping in mind the current safety precautions by WHO, CDC and MoHFW, India.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Infecções por Coronavirus/prevenção & controle , Infecção Hospitalar/prevenção & controle , Ecocardiografia/métodos , Pandemias/prevenção & controle , Segurança do Paciente , Pneumonia Viral/prevenção & controle , COVID-19 , Cardiologia , Doenças Cardiovasculares/epidemiologia , Infecções por Coronavirus/epidemiologia , Feminino , Humanos , Índia , Controle de Infecções/métodos , Masculino , Pandemias/estatística & dados numéricos , Pneumonia Viral/epidemiologia , Guias de Prática Clínica como Assunto , Síndrome Respiratória Aguda Grave/epidemiologia , Síndrome Respiratória Aguda Grave/prevenção & controle , Sociedades Médicas
2.
Talanta ; 40(10): 1499-503, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18965811

RESUMO

A method for selective extraction of Mn(II) with dithizone and potassium thiocyanate has been described. The method involves formation of a Mn(II)-thiocyanate-dithizone complex in a hexamine medium containing potassium thiocyanate (2.8M), dithizone (5.5-6.5 x 10(-5)M) and hydroxylamine hydrochloride (0.25%) at pH approximately 6 followed by extraction of the complex on polyurethane foam using batch squeezing mode within 1 hr. The sorbed Mn-thiocyanate-dithizone complex is eluted with acetone and made alkaline with 0.5 ml of a stabilizer solution (19 ml 2M NH(3) solution + 1 ml 5% hydroxylamine hydrochloride). The absorbance of the solution is measured at 506 nm. The adverse effect due to Pb may be obviated by separating the Pb as the sulphate during decomposition of sample and that due to iron may be removed before extraction of Mn by any suitable method. The other interfering elements (Cd, Zn, Ni, Co, Cu, etc.) are masked with KCN (6 x 10(-3)M optimum) solution. The method obeys Beer's Law from 0.1 to 2.0 mug Mn/ml. The method has been applied to various silicates, carbonates and glasses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...