Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
2.
Respir Med Res ; 84: 101025, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37734232

RESUMO

BACKGROUND: Automated detection of sleep apnea (SA) by pacemaker (PM) has been proposed and exhibited good agreement with polysomnography to detect severe SA. We aimed to evaluate the usefulness of SA monitoring algorithm in elderly patients with diastolic dysfunction. METHODS: Consecutive patients referred to the Caen University Hospital for PM implantation between May 2016 and December 2018 presenting isolated diastolic dysfunction were eligible for the study. The respiratory disturbance index (RDI) measured by the PM, and the mean monthly RDI (RDIm), were compared to the apnea hypopnea index (AHI) assessed with portable monitor for severe SA diagnosis. RESULTS: During the study period, 68 patients were recruited, aged of 80.4 ± 8.2 years. 63 patients underwent polygraphy with a portable monitor: 57 presented SA (83.8%), including 16 with severe SA (23.5%). Eight were treated with continuous positive airway pressure (CPAP). We found the RDI cutoff value of 22 events/h to predict severe SA, with 71.4% sensitivity and 65.2%, specificity. The RDIm cutoff value to detect severe SA was 19 events/h, with a sensitivity of 60% and a specificity of 66%. There was a significant reduction in RDI (p = 0.041), RDIm (p = 0.039) and AHI (p = 0.002) after CPAP. Supraventricular arrhythmias were frequent in all patients, regardless of SA severity, considering either episodes occurrence or total burden. CONCLUSION: In a population of elderly patients with PM and diastolic dysfunction, the SA monitoring algorithm was able to detect severe SA, with good diagnostic performance values, but also to provide follow-up data for the patients treated with CPAP.


Assuntos
Marca-Passo Artificial , Síndromes da Apneia do Sono , Idoso , Humanos , Sono , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia , Polissonografia , Algoritmos
3.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37558371

RESUMO

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Estudos de Coortes , Resultado do Tratamento , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia
4.
Front Cardiovasc Med ; 10: 1169037, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37476572

RESUMO

Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created. Objective: We aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry. Methods: A total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included. Results: In all, 13,891 radiofrequency (RF) applications of ≥3 s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 ± 19â€…Ω vs. 153.0 ± 13 Ω, p < 0.0001 for baseline LI; 22.1 ± 9â€…Ω vs. 14.4 ± 5 Ω, p < 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was >21â€…Ω at anterior sites and >18â€…Ω at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r = 0.14, 95% CI: 0.13-0.16, p < 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (-0.22, -0.23 to -0.20, p < 0.0001 for CF; -0.27, -0.29 to -0.26, p < 0.0001 for LI drop). Conclusion: An LI drop >21â€…Ω at anterior sites and >18â€…Ω at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT. Clinical trial registration: http://clinicaltrials.gov/, identifier: NCT03793998.

5.
Eur Heart J Acute Cardiovasc Care ; 12(9): 571-581, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37319361

RESUMO

AIMS: Heart transplantation (HT) can be proposed as a therapeutic strategy for patients with severe refractory electrical storm (ES). Data in the literature are scarce and based on case reports. We aimed at determining the characteristics and survival of patients transplanted for refractory ES. METHODS AND RESULTS: Patients registered on HT waiting list during the following days after ES and eventually transplanted, from 2010 to 2021, were retrospectively included in 11 French centres. The primary endpoint was in-hospital mortality. Forty-five patients were included [82% men; 55.0 (47.8-59.3) years old; 42.2% and 26.7% non-ischaemic dilated or ischaemic cardiomyopathies, respectively]. Among them, 42 (93.3%) received amiodarone, 29 received (64.4%) beta blockers, 19 (42.2%) required deep sedation, 22 had (48.9%) mechanical circulatory support, and 9 (20.0%) had radiofrequency catheter ablation. Twenty-two patients (62%) were in cardiogenic shock. Inscription on wait list and transplantation occurred 3.0 (1.0-5.0) days and 9.0 (4.0-14.0) days after ES onset, respectively. After transplantation, 20 patients (44.4%) needed immediate haemodynamic support by extracorporeal membrane oxygenation (ECMO). In-hospital mortality rate was 28.9%. Predictors of in-hospital mortality were serum creatinine/urea levels, need for immediate post-operative ECMO support, post-operative complications, and surgical re-interventions. One-year survival was 68.9%. CONCLUSION: Electrical storm is a rare indication of HT but may be lifesaving in those patients presenting intractable arrhythmias despite usual care. Most patients can be safely discharged from hospital, although post-operative mortality remains substantial in this context of emergency transplantation. Larger studies are warranted to precisely determine those patients at higher risk of in-hospital mortality.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Arritmias Cardíacas/etiologia , Choque Cardiogênico/etiologia , Oxigenação por Membrana Extracorpórea/métodos
7.
Arch Cardiovasc Dis ; 116(5): 265-271, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37179224

RESUMO

BACKGROUND: Conduction system pacing (CSP) is an emerging and promising approach for physiological ventricular pacing. While data from randomized controlled trials are scarce, use of His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP) has increased in France. AIM: To perform a national snapshot survey for cardiac electrophysiologists to evaluate adoption of CSP in France. METHODS: An online survey, distributed to every senior cardiac electrophysiologist in France, was conducted in November 2022. RESULTS: A total of 120 electrophysiologists completed the survey. Eighty-three (69%) respondents reported experience in undertaking CSP procedures and 27 (23%) were planning to start performing CSP in the coming 2 years. The implantation techniques and criteria used for successful implantation differed significantly among operators. The most frequent indications for HBP and LBBAP were high-degree atrioventricular block with left ventricular ejection fraction (LVEF) < 40% (24 and 82%, respectively) or with LVEF ≥ 40% (27 and 74%, respectively), and after failure of a coronary sinus left ventricular lead (27 and 71%, respectively). The limitations respondents most frequently perceived when performing HBP were bad sensing/pacing parameters (45%), increased procedure duration (41%) and risk of lead dislodgement (30%). The most frequently perceived limitations to performing LBBAP were absence of guidelines or consensus (31%), lack of medical training (23%) and increased procedure duration (23%). CONCLUSIONS: Our national survey-based study supports wide adoption of CSP in France. CSP is currently used as a second-line approach for both antibradycardia and resynchronization indications, with important variations regarding implantation techniques and criteria for measuring success.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Humanos , Volume Sistólico , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Função Ventricular Esquerda , Terapia de Ressincronização Cardíaca/efeitos adversos , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 34(4): 833-840, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36786515

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. METHODS: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. RESULTS: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged -56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. CONCLUSION: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Átrios do Coração , Fluoroscopia
9.
Circ Arrhythm Electrophysiol ; 16(3): e011354, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802906

RESUMO

BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do Tratamento
10.
Front Cardiovasc Med ; 9: 998883, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36386348

RESUMO

Background: Myocardial inflammation has been consistently associated with genetic arrhythmogenic cardiomyopathy (ACM) and it has been hypothesized that episodes mimicking acute myocarditis (AM) could represent early inflammatory phases of the disease. Objective: We evaluated the temporal association between recurrent acute myocarditis (RAM) episodes and the later diagnosis of a genetic ACM. Materials and methods: Between January 2012 and December 2021, patients with RAM and no previous cardiomyopathy were included (Recurrent Acute Myocarditis Registry, NCT04589156). A follow-up visit including clinical evaluation, resting and stress electrocardiogram, cardiac magnetic resonance imaging, and genetic testing was carried out. Endpoints of the study was the incidence of both ACM diagnosis criteria and ACM genetic mutation at the end of follow-up. Results: Twenty-one patients with RAM were included and follow-up was completed in 19/21 patients (90%). At the end of follow-up, 3.3 ± 2.9 years after the last AM episode, 14/21 (67%) patients with an ACM phenotype (biventricular: 10/14, 71%; left ventricular: 4/14, 29%) underwent genetic testing. A pathogenic or likely pathogenic mutation was found in 8/14 patients (57%), 5/8 in the Desmoplakin gene, 2/8 in the Plakophillin-2 gene, and 1/8 in the Titin gene. Family history of cardiomyopathy or early sudden cardiac death had a positive predictive value of 88% for the presence of an underlying genetic mutation in patients with RAM. Conclusion: RAM is a rare entity associated with the latter diagnosis of an ACM genetic mutation in more than a third of the cases. In those patients, RAM episodes represent early inflammatory phases of the disease. Including RAM episodes in ACM diagnosis criteria might allow early diagnosis and potential therapeutic interventions.

11.
Eur Heart J ; 43(47): 4887-4896, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36303402

RESUMO

AIMS: Sudden cardiac arrest remains a major complication of acute myocardial infarction (AMI) and is frequently related to ventricular fibrillation (VF). Incidence and impact of VF among patients hospitalized for AMI were evaluated. METHODS AND RESULTS: Data from the FAST-MI programme consisting of 5 French nationwide prospective cohort studies between 1995 and 2015 were analysed, totally including 14 423 patients with AMI (66 ± 14 years, 72% males, 59% ST-elevation myocardial infarction). Overall, proportion of patients presenting in-hospital VF decreased from 3.9% in 1995 to 1.8% in 2015 (P < 0.001). One-year mortality decreased from 60.7% to 24.6% (P < 0.001). However, compared with patients who did not develop VF, the over-risk of 1-year mortality associated with VF was stable over time [hazard ratio (HR) 6.78, 95% confidence interval (CI) 5.03-9.14 in 1995 and HR 6.64, 95% CI 4.20-10.49 in 2015, P = 0.52]. This increased mortality in the VF group was mainly related to fatal events occurring prior to hospital discharge, representing 86.2% of 1-year mortality, despite the very low rate of implantable cardioverter defibrillator in the VF group (2.6%). CONCLUSION: This study demonstrates that in-hospital VF incidence and mortality in the setting of AMI have significantly decreased over the past 20 years. Nevertheless, VF remained steadily associated with approximately a 10-fold increased relative risk of in-hospital mortality, without an impact on post-discharge mortality. Beyond long-term cardiac defibrillation strategy, these results emphasize the need to identify in-hospital interventions to further reduce mortality in VF patients. STUDY REGISTRATION: ClinicalTrials.gov Identifier: NCT00673036, NCT01237418, NCT02566200.


Assuntos
Infarto do Miocárdio , Fibrilação Ventricular , Masculino , Humanos , Feminino , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Estudos Prospectivos , Assistência ao Convalescente , Alta do Paciente , Infarto do Miocárdio/complicações , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/terapia , Fatores de Risco
13.
J Cardiovasc Electrophysiol ; 32(2): 545-546, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33058383

RESUMO

The IntellaMap OrionTM (Boston Scientific) is a 64-electrode basket catheter allowing for ultrahigh-density mapping of complex cardiac arrhythmias. We report the case of a basket catheter vascular entrapment, requiring surgical removal.


Assuntos
Flutter Atrial , Ablação por Cateter , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Eletrodos , Desenho de Equipamento , Humanos
14.
Eur Heart J Cardiovasc Pharmacother ; 7(4): 312-320, 2021 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-32353110

RESUMO

AIMS: The explosion of novel anticancer therapies has meant emergence of cardiotoxicity signals including atrial fibrillation (AF). Reliable data concerning the liability of anticancer drugs in inducing AF are scarce. Using the World Health Organization individual case safety report database, VigiBase®, we aimed to determine the association between anticancer drugs and AF. METHODS AND RESULTS: A disproportionality analysis evaluating the multivariable-adjusted reporting odds ratios for AF with their 99.97% confidence intervals was performed for 176 U.S. Food and Drug Administration (FDA)- or European Medicines Agency (EMA)-labelled anticancer drugs in VigiBase®, followed by a descriptive analysis of AF cases for the anticancer drugs identified in VigiBase®. ClinicalTrial registration number: NCT03530215. A total of 11 757 AF cases associated with at least one anticancer drug were identified in VigiBase® of which 95.8% were deemed serious. Nineteen anticancer drugs were significantly associated with AF of which 14 (74%) are used in haematologic malignancies and 9 (45%) represented new AF associations not previously confirmed in literature including immunomodulating agents (lenalidomide, pomalidomide), several kinase inhibitors (nilotinib, ponatinib, midostaurin), antimetabolites (azacytidine, clofarabine), docetaxel (taxane), and obinutuzumab, an anti-CD20 monoclonal antibody. CONCLUSION: Although cancer malignancy itself may generate AF, we identified 19 anticancer drugs significantly associated with a significant increase in AF over-reporting. This pharmacovigilance study provides evidence that anticancer drugs themselves could represent independent risk factors for AF development. Dedicated prospective clinical trials are now required to confirm these 19 associations. This list of suspected anticancer drugs should be known by physicians when confronted to AF in cancer patients, particularly in case of haematologic malignancies.


Assuntos
Antineoplásicos , Fibrilação Atrial , Sistemas de Notificação de Reações Adversas a Medicamentos , Antineoplásicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Humanos , Farmacovigilância , Estudos Prospectivos , Estados Unidos , Organização Mundial da Saúde
16.
Europace ; 22(11): 1628-1634, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32830226

RESUMO

AIMS: No data exist concerning the clinical performances of the subcutaneous implantable cardioverter-defibrillator (S-ICD) atrial fibrillation (AF) detection algorithm. We aimed to study the performances and implications of the latter in a 'real-world' setting. METHODS AND RESULTS: Between July 2017 and August 2019, 155 consecutive S-ICD recipients were included. Endpoint of the study was the incidence of de novo or recurrent AF using a combined on-site and remote-monitoring follow-up approach. After a mean follow-up of 13 ± 8 months, 2531 AF alerts were generated for 55 patients. A blinded analysis of the 1950 subcutaneous electrocardiograms available was performed. Among them 47% were true AF, 23% were premature atrial contractions or non-sustained AF, 29% were premature ventricular contractions or non-sustained ventricular tachycardia, and 1% were misdetection. Fourteen percent (21/155) patients had at least one correct diagnosis of AF by the S-ICD algorithm. One patient presented symptomatic paroxysmal AF not diagnosed by the S-ICD algorithm (false negative patient). Patient-based sensitivity, specificity, positive, and negative predictive values were respectively 95%, 74%, 38%, and 99%. Among patients with at least one correct diagnosis of AF, 38% (8/21) had subsequent clinical implications (anticoagulation initiation or rhythm control therapies). CONCLUSION: The S-ICD AF detection algorithm yields a high sensitivity for AF diagnosis. Low specificity and positive predictive value contribute to a high remote monitoring-notification workload and underline the necessity of a manual analysis. Atrial fibrillation diagnosis by the S-ICD AF detection algorithm might lead to significant therapeutic adjustments.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Eletrocardiografia , Humanos , Valor Preditivo dos Testes
17.
J Cardiovasc Magn Reson ; 22(1): 48, 2020 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-32580786

RESUMO

BACKGROUND: The left ventricular ejection fraction (LVEF) is the key selection criterion for an implanted cardioverter defibrillator (ICD) in primary prevention of sudden cardiac death. LVEF is usually assessed by two-dimensional echocardiography, but cardiovascular magnetic resonance (CMR) imaging is increasingly used. The aim of our study was to evaluate whether LVEF assessment using CMR imaging (CMR-LVEF) or two-dimensional echocardiography (2D echo-LVEF) may predict differently the occurrence of clinical outcomes. METHODS: In this retrospective study, we reviewed patients referred for primary prevention ICD implantation to Caen University Hospital from 2005 to 2014. We included 173 patients with either ischemic (n = 120) or dilated cardiomyopathy (n = 53) and who had undergone pre-ICD CMR imaging. The primary composite end point was the time to death from any cause or first appropriate device therapy. RESULTS: The mean CMR-LVEF was significantly lower than the mean 2D echo-LVEF (24% ± 6 vs 28% ± 6, respectively; p < 0.001). CMR-LVEF was a better independent predictive factor for the occurrence of the primary composite endpoint with a cut-off value of 22% (Hazard Ratio [HR] = 2.22; 95% CI [1.34-3.69]; p = 0.002) than 2D echo-LVEF with a cut-off value of 26% (HR = 1.61; 95% CI [0.99-2.61]; p = 0.056). Combination of the presence of scar with CMR-LVEF< 22% improved the predictive value for the occurrence of the primary outcome (HR = 2.58; 95% CI [1.54-4.30]; p < 0.001). The overall survival was higher among patients with CMR-LVEF≥22% than among patients with CMR-LVEF< 22% (p = 0.026), whereas 2D echo-LVEF was not associated with death. CONCLUSIONS: CMR-LVEF is better associated with clinical outcomes than 2D echo-LVEF in primary prevention using an ICD. Scar identification further improved the outcome prediction. The combination of CMR imaging and echocardiography should be encouraged in addition to other risk markers to better select patients.


Assuntos
Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Ecocardiografia , Cardioversão Elétrica/instrumentação , Imagem Cinética por Ressonância Magnética , Prevenção Primária/instrumentação , Volume Sistólico , Função Ventricular Esquerda , Idoso , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
18.
Europace ; 22(4): 649-656, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32097452

RESUMO

AIMS: Limited data exist concerning fragmented QRS complexes (fQRSs) on the surface electrocardiogram (ECG) of apparently healthy athletes. We aimed to study the prevalence and significance of fQRS in lead V1 (fQRSV1), representing right ventricular (RV) activation, regarding training-induced RV morphological remodelling. METHODS AND RESULTS: Between January 2017 and August 2019, 434 consecutive non-sedentary subjects underwent preparticipation cardiovascular screening, including a 12-lead ECG. Three hundred and ninety-three apparently healthy subjects were included, 119 of them were athletes (defined as performing ≥8 h/week for the last 6 months) and 274 were non-athletes. All athletes underwent two-dimensional transthoracic echocardiography. Fragmented QRS complex in lead V1 pattern was defined as a narrow (<120 ms) and quadriphasic QRS complex in lead V1. Fragmented QRS complex in lead V1 was more frequent in athletes compared with non-athletes (22% vs. 5.1%, P < 0.001) and was independently associated with the athlete status [adjusted odds ratio (aOR) = 4.693, 95% confidence interval (95% CI) 2.299-9.583; P < 0.001], the endurance category (aOR = 2.522, 95% CI 1.176-5.408; P = 0.017), and age (aOR = 0.962, 95% CI 0.934-0.989; P = 0.007) in multivariate analysis. In the subgroup of athletes, fQRSV1 was independently associated with mean RV outflow tract diameter (aOR = 1.458, 95% CI 1.105-1.923; P = 0.008) and age (aOR = 0.941, 95% CI 0.894-0.989; P = 0.017) in multivariate analysis. CONCLUSION: Fragmented QRS complex in lead V1 is a newly described, frequent, ECG pattern in young and apparently healthy athletes and is associated with training-induced RV remodelling.


Assuntos
Atletas , Eletrocardiografia , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Prevalência
19.
Heart Rhythm ; 17(4): 592-599, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31707161

RESUMO

BACKGROUND: Same-day home discharge after common atrial flutter catheter ablation (CAFCA) is a feasible, safe, and cost-effective practice, but there are currently no data for patients treated with direct oral anticoagulants (DOAs). OBJECTIVE: We evaluated the safety, efficacy, and feasibility of ambulatory CAFCA in patients treated with DOAs compared with those treated with vitamin K antagonists (VKAs). METHODS: Patients scheduled for isolated and elective ambulatory CAFCA in our tertiary university center between 2009 and 2019 were included. Propensity score for anticoagulant type was calculated from age, sex, body mass index, HAS-BLED and CHA2DS2-VASc scores, chronic kidney disease, associated antiplatelet treatment, procedure duration, and number of femoral venipunctures. RESULTS: Propensity score matching yielded 820 patients (mean age 67 ± 11 years). Catheter ablation was performed under uninterrupted VKA (n = 410; international normalized ratio 2.5 ± 0.6) or uninterrupted DOA (n = 410). The procedural success rate was 91%, and the effective same-day discharge rate was 93%. The occurrence of the primary end point, defined as any early and clinically significant bleeding (Bleeding Academic Research Consortium classification ≥ 2) at 1 week, was similar between patients treated with DOAs and those treated with VKAs (2.9% vs 3.7%; P = .70). Female sex, high HAS-BLED score, and prolonged procedure duration were independently associated with the primary end point. CONCLUSION: Uninterrupted DOA regimens are safe for patients undergoing ambulatory CAFCA in a high-volume center with a dedicated ambulatory unit and standardized procedural and postoperative management.


Assuntos
Procedimentos Cirúrgicos Ambulatórios/métodos , Anticoagulantes/administração & dosagem , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Pontuação de Propensão , Acidente Vascular Cerebral/prevenção & controle , Administração Oral , Idoso , Flutter Atrial/complicações , Flutter Atrial/tratamento farmacológico , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
20.
BMC Geriatr ; 19(1): 325, 2019 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-31752707

RESUMO

BACKGROUND: Cardiac resynchronization therapy has been shown to benefit selected patients with heart failure and reduced ejection fraction. Older patients have been underrepresented in randomized trials. This study was conducted to determine whether predictive factors for cardiac resynchronization therapy outcomes differ in patients older and younger than 75 years of age. METHODS: Consecutive patients who received a cardiac resynchronization device cardiac resynchronization therapy between 2013 and 2016 in our center were retrospectively included in this cohort study. The primary endpoint was cardiac resynchronization therapy effectiveness, which was defined as survival for one year with both no heart failure hospitalization and improvement by one or more NYHA class. The secondary endpoints were mortality, complications, and device therapies. RESULTS: Among the 243 patients included, 102 were ≥ 75 years old. Cardiac resynchronization therapy effectiveness was observed in 70 patients (50%) < 75 years old and in 48 patients (47%) ≥75 years old (p = 0.69). NYHA class ≥III (OR = 6.02; CI95% [1.33-18.77], p = 0.002) was a predictive factor for cardiac resynchronization therapy effectiveness only in the ≥75-year-old group, while atrial fibrillation was independently negatively associated with the primary endpoint in the < 75-year-old group (OR = 0.28; CI95% [0.13-0.62], p = 0.001). The one-year mortality rate was 14%, with no difference between age groups. Rescue cardiac resynchronization therapy and atrial fibrillation were independent predictive factors for mortality in both age groups. Eighty-two complications occurred in 45 patients (19%), with no difference between groups. Defibrillator use and QRS duration were independent predictive factors for complications in both age groups. There was no difference between groups considering device therapies. CONCLUSION: At one year, cardiac resynchronization therapy response is not compromised by patient age. In older patients, highly symptomatic individuals with NYHA class ≥III have better outcomes after cardiac resynchronization therapy.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Fibrilação Atrial/terapia , Desfibriladores Implantáveis , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Seleção de Pacientes , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...