Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hong Kong Med J ; 25(1): 38-47, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30713149

RESUMO

Dry eye disease is one of the most common ophthalmic complaints; it results from the activity of various pathways and is considered a multifactorial disease. An important factor that contributes to the onset of dry eye disease is meibomian gland dysfunction. Meibomian gland dysfunction causes a disruption in the tear film lipid layer which affects the rate of tear evaporation. This evaporation leads to tear hyperosmolarity, eventually triggering the onset of dry eye disease. Dry eye disease and meibomian gland dysfunction are strongly associated with each other, such that many of their risk factors, signs, and symptoms overlap. This review aimed to provide an update on the association between dry eye disease and meibomian gland dysfunction. A stepwise approach for diagnosis and management is summarised.


Assuntos
Síndromes do Olho Seco/etiologia , Doenças Palpebrais/etiologia , Glândulas Tarsais/patologia , Diagnóstico por Imagem/instrumentação , Síndromes do Olho Seco/diagnóstico por imagem , Síndromes do Olho Seco/terapia , Doenças Palpebrais/diagnóstico por imagem , Doenças Palpebrais/terapia , Corantes Fluorescentes/administração & dosagem , Humanos , Glândulas Tarsais/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Lâmpada de Fenda , Coloração e Rotulagem , Lágrimas/fisiologia
3.
Med Phys ; 42(8): 4863-71, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26233213

RESUMO

PURPOSE: Functional image guided intensity-modulated radiation therapy has the potential to improve cancer treatment quality by basing treatment parameters such as heterogeneous dose distributions information derived from imaging. However, such heterogeneous dose distributions are subject to imaging uncertainty. In this paper, the authors develop a robust optimization model to design plans that are desensitized to imaging uncertainty. METHODS: Starting from the pretreatment fluorodeoxyglucose-positron emission tomography scans, the authors use the raw voxel standard uptake values (SUVs) as input into a series of intermediate functions to transform the SUV into a desired dose. The calculated desired doses were used as an input into a robust optimization model to generate beamlet intensities. For each voxel, the authors assume that the true SUV cannot be observed but instead resides in an interval centered on the nominal (i.e., observed) SUV. Then the authors evaluated the nominal and robust solutions through a simulation study. The simulation considered the effect of the true SUV being different from the nominal SUV on the quality of the treatment plan. Treatment plans were compared on the metrics of objective function value and tumor control probability (TCP). RESULTS: Computational results demonstrate the potential for improvements in tumor control probability and deviation from the desired dose distribution compared to a nonrobust model while maintaining acceptable tissue dose. CONCLUSIONS: Robust optimization can help design treatment plans that are more stable in the presence of image value uncertainties.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Simulação por Computador , Conjuntos de Dados como Assunto , Fluordesoxiglucose F18 , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Movimento (Física) , Imagem Multimodal/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/fisiopatologia , Neoplasias/radioterapia , Probabilidade , Doses de Radiação , Compostos Radiofarmacêuticos , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos , Incerteza
4.
Eye (Lond) ; 29(8): 1069-75, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26021865

RESUMO

PURPOSE: To describe a hybrid procedure for orbital venous malformation in the endovascular operating room (EVOR). METHODS: Five consecutive patients with venous malformation in the periocular and orbital region were included. All patients received a one-stage direct puncture venogram, image-guided glue injection, and surgical resection in the EVOR equipped with a biplane digital subtraction angiography system (BDSAS). RESULTS: The mean age at the time of operation was 37.4 years (range, 22-69 years). The mean operative time was 193 min (range, 138-324 min). No intraoperative complications were noted. The mean follow-up duration was 18.8 months (range, 10-24 months). Three patients had complete removal of the vascular lesions. At the latest follow-up, no recurrence of symptoms related to the lesions was noted. All patients had an uneventful recovery and satisfactory outcome. CONCLUSIONS: The hybrid procedure of orbital venous malformation in the EVOR is a novel application in ophthalmology. It is a safe and well-controlled procedure with real-time high-quality BDSAS surveillance to facilitate surgical resection. Its success requires collaboration between the interventional radiologist, the surgeon, and the ophthalmologist.


Assuntos
Órbita/irrigação sanguínea , Malformações Vasculares/cirurgia , Adulto , Idoso , Doenças da Túnica Conjuntiva/etiologia , Doenças da Túnica Conjuntiva/cirurgia , Doenças Palpebrais/etiologia , Doenças Palpebrais/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Procedimentos Cirúrgicos Oftalmológicos/métodos , Órbita/cirurgia , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...