Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Dairy Sci ; 106(12): 8885-8896, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37641362

RESUMO

The objective of this study was to describe the cleaning practices currently used for preweaning calves on dairy farms in Quebec, Canada. In addition, contamination of feeding equipment for preweaning calves was described using ATP (expressed as relative light units, RLU), visual assessment, and bacteriological analysis. A questionnaire was administered on 50 commercial dairy farms in Quebec, Canada, regarding the self-reported cleaning protocol used for feeding equipment of preweaning calves. During the visit, a visual score was given to the feeding equipment available at the farm. Afterward, ATP luminometry measurements were obtained using Hygiene UltraSnap and MicroSnap swabs (Hygiene, Camarillo, CA), and the liquid rinsing technique for buckets, nipples, bottles, esophageal tube feeders (ET), the tube of automatic milk feeders (AMF), water samples, and milk replacer. An additional direct swabbing technique was performed on buckets and nipples. The fluid retrieved from the liquid rinsing technique was also used to determine the total bacterial count (TBC) and total coliform count. Based on the bacteriological analysis, optimal RLU cutoff values to determine contamination were obtained. The median (interquartile range) luminometer measurements using the UltraSnap and direct technique for buckets and nipples were 2,082 (348-7,410) and 3,462 (462-7,518) RLU, respectively; and, using the liquid technique for bottles, ET, AMF, water, and milk replacer were 43 (4-974), 15 (4-121), 301 (137-1,323), 190 (71-358), and 94 (38-218) RLU, respectively. Overall, for all equipment and both techniques used, higher RLU values were seen in UltraSnap samples compared with MicroSnap samples. Additionally, for buckets and nipples, higher RLU values were obtained for the direct swabbing method compared with the liquid sampling method for both swabs used. No differences in the level of contamination were seen between the different feeding equipment used within a farm. Overall, a higher correlation with bacteriological results was noticed for ATP luminometry compared with the visual score, with a high correlation for nipples and bottles using the UltraSnap and liquid technique. Based on the classification of "contaminated" (TBC ≥100,000 cfu/mL) or "not contaminated" (TBC <100,000 cfu/mL), optimal ATP luminometer cutoff values for buckets, nipples, bottles, AMF, water, and milk replacer were 798, 388, 469, 282, 1,432, and 93 RLU, respectively. No clear association was found between ATP measurements and the self-reported cleaning protocol. This study gave new insights into the current cleaning procedures and contamination of feeding equipment for preweaning calves on dairy farms in Quebec. In addition, ATP luminometry cutoff values could help benchmark farms regarding cleaning practices and provide customized advice, improving the overall hygiene management, and thus the health, of preweaning calves on dairy farms.


Assuntos
Trifosfato de Adenosina , Indústria de Laticínios , Animais , Bovinos , Indústria de Laticínios/métodos , Fazendas , Higiene , Leite/microbiologia , Quebeque , Água , Desmame
2.
J Dairy Sci ; 106(9): 6263-6274, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37500439

RESUMO

The objective of this cross-sectional study was to standardize a reliable and repeatable swabbing technique using ATP luminometry (light emission proportional to the amount of ATP with result provided in relative light units [RLU]) to describe the cleanliness of various feeding equipment used for preweaning calves in dairy farms. A total of 7 Québec commercial dairy herds were selected conveniently. Following visual hygiene scoring, the cleanliness of every available piece of feeding equipment was assessed using direct surface swabbing for buckets and nipples with Hygiena UltraSnap swabs. A liquid rinsing technique was used for esophageal feeders, bottles, and automatic milk feeders (AMF) with UltraSnap, AquaSnap, and MicroSnap swabs. To validate direct swabbing technique of buckets, a stage within and between operators was realized, as well as a conventional bacterial culture. A total of 519 swab samples were obtained from 201 pieces of equipment. The median (interquartile range) contamination in RLU for a bottle, esophageal feeder, AMF, bucket and nipple was 2 (1;6), 2 (0;12), 52 (19;269), 886 (128;7,230) and 899 (142;6,928), respectively. The direct swabbing technique, which consists in swabbing directly the surface of an equipment, showed excellent correlation for intrarater reliability (intraclass correlation (ICC) = 0.93; 95% CI: 0.88-0.96). The interoperator (2 sessions with 3 different operators) reliability also showed high correlation (ICC = 0.88; 95% CI: 0.78-0.94 for the first session, and ICC = 0.89; 95% CI: 0.79-0.95 for the second session). Luminometer values were positively associated with the visual score of esophageal feeders, AMF and buckets. A positive correlation between bacterial culture and direct swabbing of buckets was also found for the UltraSnap (rs = 0.653; 95% CI: 0.283-0.873; P = 0.0003) and MicroSnap (rs = 0.569, 95% CI: 0.309-0.765; P = 0.002). This study describes a standardized and practical on-farm swabbing technique for assessing the hygienic status of feeding equipment by luminometry, which can be integrated in the investigation of preweaning dairy calves problems.


Assuntos
Indústria de Laticínios , Leite , Animais , Bovinos , Estudos Transversais , Reprodutibilidade dos Testes , Indústria de Laticínios/métodos , Leite/microbiologia , Padrões de Referência , Trifosfato de Adenosina , Desmame
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...